{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T02:16:42Z","timestamp":1780625802249,"version":"3.54.1"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,6,2]],"date-time":"2021-06-02T00:00:00Z","timestamp":1622592000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,6,2]],"date-time":"2021-06-02T00:00:00Z","timestamp":1622592000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Medizinische Hochschule Hannover (MHH)"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Two-part abutments are typically made up of a base composed of titanium and a ceramic build-up. The long-term outcomes are affected by the mechanical durability. The purpose of the present investigation was to evaluate and compare the retention force of two-part abutment systems with titanium or titanium nitride bases\u2014as fixed with zirconia components and with various surface treatments.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A total of 60 two-part abutments were investigated\u2014with a titanium base (n\u2009=\u200930) or titanium nitride coated bases (n\u2009=\u200930) and bonded with zirconia ceramic build-ups. The bonding surfaces were treated with aluminium oxide blasting, with an average particle size of 110\u00a0\u00b5m. The titanium bases were then pretreated with Alloy Primer or Clearfil Ceramic Primer. The ceramic build-ups were only treated with Clearfil Ceramic Primer. For twenty test specimens, no chemical pretreatment was performed. Test specimens were classified into six groups in accordance with the pretreatment (A\u2013F; n\u2009=\u200910). A resin-based luting agent was employed to attach the two parts. Specimens were then subjected to artificial thermal aging (10<jats:sup>4<\/jats:sup> cycles with 5\u00a0\u00b0C\/55\u00a0\u00b0C). The retention force between the two parts was then investigated with a pull-off test. The findings were analyzed by ANOVA statistics. Fracture patterns were examined by electron microscopy.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>In the absence of primer<jats:italic>,<\/jats:italic> titanium nitride coated bases gave significantly greater retention forces than other samples (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05). Chemical preconditioning with silane coupling agents did not effect on the retention force of coated bases.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The results of the current study suggested that modifying metal surfaces by coating the base with titanium nitride not only has esthetic and biological advantages, but also enhances the mechanical properties of the adhesive bond of two-part abutments.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12903-021-01636-7","type":"journal-article","created":{"date-parts":[[2021,6,2]],"date-time":"2021-06-02T20:04:38Z","timestamp":1622664278000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["In vitro evaluation of the influence of titanium nitride coating on the retention force between components of two-part abutments"],"prefix":"10.1186","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0326-4402","authenticated-orcid":false,"given":"Nadine","family":"Freifrau von Maltzahn","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Holstermann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meike","family":"Stiesch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Kohorst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,6,2]]},"reference":[{"key":"1636_CR1","doi-asserted-by":"publisher","first-page":"370","DOI":"10.11607\/ijp.3501","volume":"26","author":"A Hamilton","year":"2013","unstructured":"Hamilton A, Judge RB, Palamara JE, Evans C. Evaluation of the fit of CAD\/CAM abutments. Int J Prosthodont. 2013;26:370\u201380.","journal-title":"Int J Prosthodont"},{"key":"1636_CR2","first-page":"E141","volume":"14","author":"MA Fuster-Torres","year":"2009","unstructured":"Fuster-Torres MA, Albalat-Estela S, Alcaniz-Raya M, Penarrocha-Diago M. CAD \/ CAM dental systems in implant dentistry: update. Med Oral Patol Oral Cir Bucal. 2009;14:E141\u20135.","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"1636_CR3","doi-asserted-by":"publisher","first-page":"1133","DOI":"10.1111\/clr.12928","volume":"28","author":"A Ioannidis","year":"2017","unstructured":"Ioannidis A, Cathomen E, Jung RE, Fehmer V, Husler J, Thoma DS. Discoloration of the mucosa caused by different restorative materials - a spectrophotometric in vitro study. Clin Oral Implants Res. 2017;28:1133\u20138.","journal-title":"Clin Oral Implants Res"},{"key":"1636_CR4","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1111\/j.1600-0501.2007.01391.x","volume":"18","author":"SE Park","year":"2007","unstructured":"Park SE, Da Silva JD, Weber HP, Ishikawa-Nagai S. Optical phenomenon of peri-implant soft tissue. Part I. Spectrophotometric assessment of natural tooth gingiva and peri-implant mucosa. Clin Oral Implants Res. 2007;18:569\u201374.","journal-title":"Clin Oral Implants Res."},{"key":"1636_CR5","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1002\/jbm.b.31147","volume":"88","author":"M Hisbergues","year":"2009","unstructured":"Hisbergues M, Vendeville S, Vendeville P. Zirconia: Established facts and perspectives for a biomaterial in dental implantology. J Biomed Mater Res B Appl Biomater. 2009;88:519\u201329.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"1636_CR6","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1016\/j.jdent.2007.07.008","volume":"35","author":"PF Manicone","year":"2007","unstructured":"Manicone PF, Rossi Iommetti P, Raffaelli L. An overview of zirconia ceramics: basic properties and clinical applications. J Dent. 2007;35:819\u201326.","journal-title":"J Dent"},{"key":"1636_CR7","first-page":"299","volume":"23","author":"K Nakamura","year":"2010","unstructured":"Nakamura K, Kanno T, Milleding P, Ortengren U. Zirconia as a dental implant abutment material: a systematic review. Int J Prosthodont. 2010;23:299\u2013309.","journal-title":"Int J Prosthodont"},{"key":"1636_CR8","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1111\/j.1708-8240.2003.tb00278.x","volume":"15","author":"U Brodbeck","year":"2003","unstructured":"Brodbeck U. The ZiReal Post: A new ceramic implant abutment. J Esthet Restor Dent. 2003;15:10\u201323 (discussion 4).","journal-title":"J Esthet Restor Dent."},{"key":"1636_CR9","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.jmbbm.2016.05.011","volume":"62","author":"R Coray","year":"2016","unstructured":"Coray R, Zeltner M, Ozcan M. Fracture strength of implant abutments after fatigue testing: a systematic review and a meta-analysis. J Mech Behav Biomed Mater. 2016;62:333\u201346.","journal-title":"J Mech Behav Biomed Mater"},{"key":"1636_CR10","doi-asserted-by":"publisher","first-page":"546","DOI":"10.11607\/jomi.3942","volume":"30","author":"P Gehrke","year":"2015","unstructured":"Gehrke P, Johannson D, Fischer C, Stawarczyk B, Beuer F. In vitro fatigue and fracture resistance of one- and two-piece CAD\/CAM zirconia implant abutments. Int J Oral Maxillofac Implants. 2015;30:546\u201354.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"1636_CR11","first-page":"928","volume":"22","author":"WN Garine","year":"2007","unstructured":"Garine WN, Funkenbusch PD, Ercoli C, Wodenscheck J, Murphy WC. Measurement of the rotational misfit and implant-abutment gap of all-ceramic abutments. Int J Oral Maxillofac Implants. 2007;22:928\u201338.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"1636_CR12","first-page":"1029","volume":"23","author":"RB Kerstein","year":"2008","unstructured":"Kerstein RB, Radke J. A comparison of fabrication precision and mechanical reliability of 2 zirconia implant abutments. Int J Oral Maxillofac Implants. 2008;23:1029\u201336.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"1636_CR13","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1111\/cid.12060","volume":"16","author":"P Gehrke","year":"2014","unstructured":"Gehrke P, Alius J, Fischer C, Erdelt KJ, Beuer F. Retentive strength of two-piece CAD\/CAM zirconia implant abutments. Clin Implant Dent Relat Res. 2014;16:920\u20135.","journal-title":"Clin Implant Dent Relat Res"},{"key":"1636_CR14","first-page":"921","volume":"22","author":"A Ebert","year":"2007","unstructured":"Ebert A, Hedderich J, Kern M. Retention of zirconia ceramic copings bonded to titanium abutments. Int J Oral Maxillofac Implants. 2007;22:921\u20137.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"1636_CR15","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1111\/j.1532-849X.2012.00847.x","volume":"21","author":"TV Carnaggio","year":"2012","unstructured":"Carnaggio TV, Conrad R, Engelmeier RL, Gerngross P, Paravina R, Perezous L, et al. Retention of CAD\/CAM all-ceramic crowns on prefabricated implant abutments: an in vitro comparative study of luting agents and abutment surface area. J Prosthodont. 2012;21:523\u20138.","journal-title":"J Prosthodont"},{"issue":"Suppl A100","key":"1636_CR16","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1111\/j.1600-0501.2011.02358.x","volume":"24","author":"F Nejatidanesh","year":"2013","unstructured":"Nejatidanesh F, Savabi O, Shahtoosi M. Retention of implant-supported zirconium oxide ceramic restorations using different luting agents. Clin Oral Implants Res. 2013;24(Suppl A100):20\u20134.","journal-title":"Clin Oral Implants Res."},{"key":"1636_CR17","doi-asserted-by":"publisher","first-page":"1134","DOI":"10.1111\/cid.12418","volume":"18","author":"M Ferrari","year":"2016","unstructured":"Ferrari M, Tricarico MG, Cagidiaco MC, Vichi A, Gherlone EF, Zarone F, et al. 3-Year randomized controlled prospective clinical trial on different CAD-CAM implant abutments. Clin Implant Dent Relat Res. 2016;18:1134\u201341.","journal-title":"Clin Implant Dent Relat Res"},{"key":"1636_CR18","doi-asserted-by":"publisher","first-page":"393","DOI":"10.11607\/jomi.4794","volume":"32","author":"M Ferrari","year":"2017","unstructured":"Ferrari M, Carrabba M, Vichi A, Goracci C, Cagidiaco MC. Influence of abutment color and mucosal thickness on soft tissue color. Int J Oral Maxillofac Implants. 2017;32:393\u20139.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"1636_CR19","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1002\/jbm.10307","volume":"63","author":"KH Chung","year":"2002","unstructured":"Chung KH, Duh JG, Shin D, Cagna DR, Cronin RJ Jr. Characteristics and porcelain bond strength of (Ti, Al)N coating on dental alloys. J Biomed Mater Res. 2002;63:516\u201321.","journal-title":"J Biomed Mater Res"},{"key":"1636_CR20","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1111\/cid.12352","volume":"18","author":"NF von Maltzahn","year":"2016","unstructured":"von Maltzahn NF, Holstermann J, Kohorst P. Retention forces between titanium and zirconia components of two-part implant abutments with different techniques of surface modification. Clin Implant Dent Relat Res. 2016;18:735\u201344.","journal-title":"Clin Implant Dent Relat Res"},{"key":"1636_CR21","doi-asserted-by":"publisher","first-page":"4547","DOI":"10.1016\/j.actbio.2010.07.025","volume":"6","author":"L Borchers","year":"2010","unstructured":"Borchers L, Stiesch M, Bach FW, Buhl JC, Hubsch C, Kellner T, et al. Influence of hydrothermal and mechanical conditions on the strength of zirconia. Acta Biomater. 2010;6:4547\u201352.","journal-title":"Acta Biomater"},{"key":"1636_CR22","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1111\/clr.13495","volume":"30","author":"NF von Maltzahn","year":"2019","unstructured":"von Maltzahn NF, Bernard S, Kohorst P. Two-part implant abutments with titanium and ceramic components: surface modification affects retention forces-An in-vitro study. Clin Oral Implants Res. 2019;30:903\u20139.","journal-title":"Clin Oral Implants Res."},{"key":"1636_CR23","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1111\/j.1600-0722.2007.00429.x","volume":"115","author":"P Kohorst","year":"2007","unstructured":"Kohorst P, Herzog TJ, Borchers L, Stiesch-Scholz M. Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks. Eur J Oral Sci. 2007;115:161\u20136.","journal-title":"Eur J Oral Sci"},{"key":"1636_CR24","doi-asserted-by":"publisher","first-page":"451","DOI":"10.11607\/ijp.5817","volume":"31","author":"NF von Maltzahn","year":"2018","unstructured":"von Maltzahn NF, El Meniawy OI, Breitenbuecher N, Kohorst P, Stiesch M, Eisenburger M. Fracture strength of ceramic posterior occlusal veneers for functional rehabilitation of an abrasive dentition. Int J Prosthodont. 2018;31:451\u20132.","journal-title":"Int J Prosthodont"},{"key":"1636_CR25","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1563\/AAID-JOI-D-10-00151","volume":"39","author":"M Kurt","year":"2013","unstructured":"Kurt M, Kulunk T, Ural C, Kulunk S, Danisman S, Savas S. The effect of different surface treatments on cement-retained implant-supported restorations. J Oral Implantol. 2013;39:44\u201351.","journal-title":"J Oral Implantol"},{"key":"1636_CR26","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1016\/S0109-5641(98)00011-6","volume":"14","author":"M Kern","year":"1998","unstructured":"Kern M, Wegner SM. Bonding to zirconia ceramic: adhesion methods and their durability. Dent Mater. 1998;14:64\u201371.","journal-title":"Dent Mater"},{"key":"1636_CR27","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1016\/j.prosdent.2004.02.001","volume":"91","author":"MB Blatz","year":"2004","unstructured":"Blatz MB, Sadan A, Martin J, Lang B. In vitro evaluation of shear bond strengths of resin to densely-sintered high-purity zirconium-oxide ceramic after long-term storage and thermal cycling. J Prosthet Dent. 2004;91:356\u201362.","journal-title":"J Prosthet Dent"},{"key":"1636_CR28","first-page":"745","volume":"38","author":"MB Blatz","year":"2007","unstructured":"Blatz MB, Chiche G, Holst S, Sadan A. Influence of surface treatment and simulated aging on bond strengths of luting agents to zirconia. Quintessence Int. 2007;38:745\u201353.","journal-title":"Quintessence Int"},{"key":"1636_CR29","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1002\/jbm.b.30097","volume":"71","author":"Y Zhang","year":"2004","unstructured":"Zhang Y, Lawn BR, Rekow ED, Thompson VP. Effect of sandblasting on the long-term performance of dental ceramics. J Biomed Mater Res B Appl Biomater. 2004;71:381\u20136.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"1636_CR30","doi-asserted-by":"publisher","first-page":"2153","DOI":"10.1016\/j.biomaterials.2003.08.056","volume":"25","author":"M Guazzato","year":"2004","unstructured":"Guazzato M, Albakry M, Quach L, Swain MV. Influence of grinding, sandblasting, polishing and heat treatment on the flexural strength of a glass-infiltrated alumina-reinforced dental ceramic. Biomaterials. 2004;25:2153\u201360.","journal-title":"Biomaterials"},{"key":"1636_CR31","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1016\/j.dental.2004.07.021","volume":"21","author":"AK Murray","year":"2005","unstructured":"Murray AK, Attrill DC, Dickinson MR. The effects of XeCl laser etching of Ni-Cr alloy on bond strengths to composite resin: a comparison with sandblasting procedures. Dent Mater. 2005;21:538\u201344.","journal-title":"Dent Mater"},{"key":"1636_CR32","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1016\/S0142-9612(00)00002-8","volume":"21","author":"A Gaggl","year":"2000","unstructured":"Gaggl A, Schultes G, Muller WD, Karcher H. Scanning electron microscopical analysis of laser-treated titanium implant surfaces\u2013a comparative study. Biomaterials. 2000;21:1067\u201373.","journal-title":"Biomaterials"},{"key":"1636_CR33","doi-asserted-by":"publisher","first-page":"629","DOI":"10.2334\/josnusd.51.629","volume":"51","author":"F Komine","year":"2009","unstructured":"Komine F, Kobayashi K, Saito A, Fushiki R, Koizumi H, Matsumura H. Shear bond strength between an indirect composite veneering material and zirconia ceramics after thermocycling. J Oral Sci. 2009;51:629\u201334.","journal-title":"J Oral Sci"},{"key":"1636_CR34","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1177\/0022034509340881","volume":"88","author":"M Kern","year":"2009","unstructured":"Kern M, Barloi A, Yang B. Surface conditioning influences zirconia ceramic bonding. J Dent Res. 2009;88:817\u201322.","journal-title":"J Dent Res"},{"key":"1636_CR35","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/j.jdent.2005.07.002","volume":"34","author":"K Tanaka","year":"2006","unstructured":"Tanaka K, Kimoto K, Sawada T, Toyoda M. Shear bond strength of veneering composite resin to titanium nitride coating alloy deposited by radiofrequency sputtering. J Dent. 2006;34:277\u201382.","journal-title":"J Dent"},{"key":"1636_CR36","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1016\/0022-3913(92)90239-7","volume":"67","author":"DS Palmer","year":"1992","unstructured":"Palmer DS, Barco MT, Billy EJ. Temperature extremes produced orally by hot and cold liquids. J Prosthet Dent. 1992;67:325\u20137.","journal-title":"J Prosthet Dent"},{"key":"1636_CR37","unstructured":"Pfeiffer P, Marx R. [Temperature loading of resin-bonded bridges and its effect on the composite strength of the adhesive bond]. Schweiz Monatsschr Zahnmed. 1989;99:782\u20136. Temperaturbelastung von Adhasivbrucken und ihre Auswirkung auf die Verbundfestigkeit der Klebeverbindung."},{"key":"1636_CR38","doi-asserted-by":"publisher","first-page":"208","DOI":"10.2341\/11-076-L","volume":"38","author":"GB Guarda","year":"2013","unstructured":"Guarda GB, Correr AB, Goncalves LS, Costa AR, Borges GA, Sinhoreti MA, et al. Effects of surface treatments, thermocycling, and cyclic loading on the bond strength of a resin cement bonded to a lithium disilicate glass ceramic. Oper Dent. 2013;38:208\u201317.","journal-title":"Oper Dent"},{"key":"1636_CR39","first-page":"393","volume":"59","author":"AM Mesquita","year":"2010","unstructured":"Mesquita AM, Ozcan M, Souza RO, Kojima AN, Nishioka RS, Kimpara ET, et al. Durability of feldspathic veneering ceramic on glass-infiltrated alumina ceramics after long-term thermocycling. Minerva Stomatol. 2010;59:393\u20139.","journal-title":"Minerva Stomatol"},{"key":"1636_CR40","first-page":"191","volume":"22","author":"PC Pereira","year":"2009","unstructured":"Pereira PC, Castilho AA, Souza RO, Passos SP, Takahashi FE, Bottino MA. A comparison of the film thickness of two adhesive luting agents and the effect of thermocycling on their microTBs to feldspathic ceramic. Acta Odontol Latinoam. 2009;22:191\u2013200.","journal-title":"Acta Odontol Latinoam"},{"key":"1636_CR41","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1177\/0022034514524228","volume":"93","author":"M Inokoshi","year":"2014","unstructured":"Inokoshi M, De Munck J, Minakuchi S, Van Meerbeek B. Meta-analysis of bonding effectiveness to zirconia ceramics. J Dent Res. 2014;93:329\u201334.","journal-title":"J Dent Res"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-021-01636-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-021-01636-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-021-01636-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,2]],"date-time":"2021-06-02T20:05:39Z","timestamp":1622664339000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-021-01636-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,2]]},"references-count":41,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["1636"],"URL":"https:\/\/doi.org\/10.1186\/s12903-021-01636-7","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,2]]},"assertion":[{"value":"18 June 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 June 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"285"}}