{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T16:30:59Z","timestamp":1794328259221,"version":"4.9.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T00:00:00Z","timestamp":1683072000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T00:00:00Z","timestamp":1683072000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Korea Medical Device Development Fund grant funded by the Korea government","award":["KMDF_PR_20200901_0040"],"award-info":[{"award-number":["KMDF_PR_20200901_0040"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Computer-aided design\/manufacturing (CAD\/CAM) technology was developed to improve surgical accuracy and minimize errors in surgical planning and orthognathic surgery. However, its accurate implementation during surgery remains a challenge. Hence, we compared the accuracy and stability of conventional orthognathic surgery and the novel modalities, such as virtual simulation and three-dimensional (3D) titanium-printed customized surgical osteotomy guides and plates.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>This prospective study included 12 patients who were willing to undergo orthognathic surgery. The study group consisted of patients who underwent orthognathic two-jaw surgery using 3D-printed patient-specific plates processed by selective laser melting and an osteotomy guide; orthognathic surgery was also performed by the surgeon directly bending the ready-made plate in the control group. Based on the preoperative computed tomography images and intraoral 3D scan data, a 3D virtual surgery plan was implemented in the virtual simulation module, and the surgical guide and bone fixation plate were fabricated. The accuracy and stability were evaluated by comparing the results of the preoperative virtual simulation (T0) to those at 7\u00a0days (T1) and 6\u00a0months (T2) post-surgery.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Result<\/jats:title>\n                <jats:p>The accuracy (\u0394T1\u2012T0) and stability (\u0394T2\u2012T1) measurements, using 11 anatomical references, both demonstrated more accurate results in the study group. The mean difference of accuracy for the study group (0.485\u2009\u00b1\u20090.280\u00a0mm) was significantly lower than in the control group (1.213\u2009\u00b1\u20090.716\u00a0mm) (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01). The mean operation time (6.83\u2009\u00b1\u20090.72\u00a0h) in the control group was longer than in the study group (5.76\u2009\u00b1\u20090.43\u00a0h) (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>This prospective clinical study demonstrated the accuracy, stability, and effectiveness of using virtual preoperative simulation and patient-customized osteotomy guides and plates for orthognathic surgery.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12903-023-03000-3","type":"journal-article","created":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T11:01:52Z","timestamp":1683111712000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":40,"title":["Effectiveness of individualized 3D titanium-printed Orthognathic osteotomy guides and custom plates"],"prefix":"10.1186","volume":"23","author":[{"given":"Se-hyang","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung-Min","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jung-Hyun","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sook","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin-Woo","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,5,3]]},"reference":[{"issue":"1","key":"3000_CR1","doi-asserted-by":"publisher","first-page":"ZC10","DOI":"10.7860\/JCDR\/2017\/22455.9133","volume":"11","author":"PR Venkategowda","year":"2017","unstructured":"Venkategowda PR, Prakash AT, Roy ET, Shetty KS, Thakkar S, Maurya R. Stability of vertical, horizontal and angular parameters following superior repositioning of maxilla by Le Fort I osteotomy: a cephalometric study. J Clin Diagn Res. 2017;11(1):ZC10\u20134. https:\/\/doi.org\/10.7860\/JCDR\/2017\/22455.9133.","journal-title":"J Clin Diagn Res"},{"issue":"9","key":"3000_CR2","doi-asserted-by":"publisher","first-page":"926","DOI":"10.1016\/j.ijom.2011.04.001","volume":"40","author":"C Murphy","year":"2011","unstructured":"Murphy C, Kearns G, Sleeman D, Cronin M, Allen PF. The clinical relevance of orthognathic surgery on quality of life. Int J Oral Maxillofac Surg. 2011;40(9):926\u201330. https:\/\/doi.org\/10.1016\/j.ijom.2011.04.001.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"11","key":"3000_CR3","doi-asserted-by":"publisher","first-page":"1103","DOI":"10.1016\/j.ijom.2010.07.004","volume":"39","author":"JC Barbenel","year":"2010","unstructured":"Barbenel JC, Paul PE, Khambay BS, Walker FS, Moos KF, Ayoub AF. Errors in orthognathic surgery planning: the effect of inaccurate study model orientation. Int J Oral Maxillofac Surg. 2010;39(11):1103\u20138. https:\/\/doi.org\/10.1016\/j.ijom.2010.07.004.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"3","key":"3000_CR4","doi-asserted-by":"publisher","first-page":"e229","DOI":"10.1097\/SCS.0b013e3182869b00","volume":"24","author":"W Zhang","year":"2013","unstructured":"Zhang W, Li B, Gui H, Zhang L, Wang X, Shen G. Reconstruction of complex mandibular defect with computer-aided navigation and orthognathic surgery. J Craniofac Surg. 2013;24(3):e229\u201333. https:\/\/doi.org\/10.1097\/SCS.0b013e3182869b00.","journal-title":"J Craniofac Surg"},{"issue":"1","key":"3000_CR5","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s12903-019-0711-y","volume":"19","author":"JW Kim","year":"2019","unstructured":"Kim JW, Kim JC, Jeong CG, et al. The accuracy and stability of the maxillary position after orthognathic surgery using a novel computer-aided surgical simulation system. BMC Oral Health. 2019;19(1):18. https:\/\/doi.org\/10.1186\/s12903-019-0711-y. Published 2019 Jan 15.","journal-title":"BMC Oral Health"},{"issue":"1","key":"3000_CR6","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1186\/s40902-020-00272-5","volume":"42","author":"JH Park","year":"2020","unstructured":"Park JH, Odkhuu M, Cho S, Li J, Park BY, Kim JW. 3D-printed titanium implant with pre-mounted dental implants for mandible reconstruction: a case report. Maxillofac Plast Reconstr Surg. 2020;42(1):28. https:\/\/doi.org\/10.1186\/s40902-020-00272-5. Published 2020 Aug 14.","journal-title":"Maxillofac Plast Reconstr Surg"},{"issue":"11","key":"3000_CR7","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.3390\/jpm11111087","volume":"11","author":"M Kim","year":"2021","unstructured":"Kim M, Li J, Kim S, et al. Individualized 3D-printed bone-anchored maxillary protraction device for growth modification in skeletal class III malocclusion. J Pers Med. 2021;11(11):1087. https:\/\/doi.org\/10.3390\/jpm11111087. Published 2021 Oct 26.","journal-title":"J Pers Med"},{"issue":"3","key":"3000_CR8","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.bjoms.2013.12.010","volume":"52","author":"G De Riu","year":"2014","unstructured":"De Riu G, Meloni SM, Baj A, Corda A, Soma D, Tullio A. Computer-assisted orthognathic surgery for correction of facial asymmetry: results of a randomised controlled clinical trial. Br J Oral Maxillofac Surg. 2014;52(3):251\u20137. https:\/\/doi.org\/10.1016\/j.bjoms.2013.12.010.","journal-title":"Br J Oral Maxillofac Surg"},{"issue":"1","key":"3000_CR9","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1053\/joms.2002.29069","volume":"60","author":"G Bettega","year":"2002","unstructured":"Bettega G, Cinquin P, Lebeau J, Rapha\u00ebl B. Computer-assisted orthognathic surgery: clinical evaluation of a mandibular condyle repositioning system. J Oral Maxillofac Surg. 2002;60(1):27\u201335. https:\/\/doi.org\/10.1053\/joms.2002.29069.","journal-title":"J Oral Maxillofac Surg"},{"issue":"2S Suppl 1","key":"3000_CR10","doi-asserted-by":"publisher","first-page":"S70","DOI":"10.1097\/SAP.0000000000002622","volume":"86","author":"CT Ho","year":"2021","unstructured":"Ho CT, Denadai R, Lin HH, Lo LJ. Three-dimensional computer-assisted orthognathic surgery: traditional hybrid versus full digital planning models. Ann Plast Surg. 2021;86(2S Suppl 1):S70\u20137. https:\/\/doi.org\/10.1097\/SAP.0000000000002622.","journal-title":"Ann Plast Surg"},{"issue":"4","key":"3000_CR11","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1016\/j.jfma.2015.01.017","volume":"114","author":"HH Lin","year":"2015","unstructured":"Lin HH, Lo LJ. Three-dimensional computer-assisted surgical simulation and intraoperative navigation in orthognathic surgery: a literature review. J Formos Med Assoc. 2015;114(4):300\u20137. https:\/\/doi.org\/10.1016\/j.jfma.2015.01.017.","journal-title":"J Formos Med Assoc"},{"key":"3000_CR12","unstructured":"Cheng-Ting Ho, Hsiu-Hsia Lin, Lun-Jou Lo. Division of Orthodontics, Department of Dentistry, the Craniofacial Research Center, and the Department of Plastic and Reconstructive Surgery, Chang Gung Memorial Hospital. https:\/\/pubmed.ncbi.nlm.nih.gov\/31033828\/."},{"key":"3000_CR13","unstructured":"Turki Almutairi, Kurt Naudi, Neil Nairn, Xiangyang Ju, John Whitters, Ashraf Ayoub. https:\/\/pubmed.ncbi.nlm.nih.gov\/29572134\/."},{"issue":"2","key":"3000_CR14","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1016\/j.ijom.2021.04.002","volume":"51","author":"J Harding","year":"2022","unstructured":"Harding J, Hartsfield JK Jr, Mian AS, et al. Accuracy of mandibular proximal segment position using virtual surgical planning and custom osteosynthesis plates. Int J Oral Maxillofac Surg. 2022;51(2):219\u201325. https:\/\/doi.org\/10.1016\/j.ijom.2021.04.002.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"2","key":"3000_CR15","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1111\/ocr.12363","volume":"23","author":"RH Tonin","year":"2020","unstructured":"Tonin RH, Iwaki Filho L, Yamashita AL, et al. Accuracy of 3D virtual surgical planning for maxillary positioning and orientation in orthognathic surgery. Orthod Craniofac Res. 2020;23(2):229\u201336. https:\/\/doi.org\/10.1111\/ocr.12363.","journal-title":"Orthod Craniofac Res"},{"issue":"2","key":"3000_CR16","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1016\/j.joms.2006.10.005","volume":"65","author":"JJ Xia","year":"2007","unstructured":"Xia JJ, Gateno J, Teichgraeber JF, et al. Accuracy of the computer-aided surgical simulation (CASS) system in the treatment of patients with complex craniomaxillofacial deformity: a pilot study. J Oral Maxillofac Surg. 2007;65(2):248\u201354. https:\/\/doi.org\/10.1016\/j.joms.2006.10.005.","journal-title":"J Oral Maxillofac Surg"},{"issue":"6","key":"3000_CR17","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/0266-4356(93)90187-2","volume":"31","author":"DC Bryan","year":"1993","unstructured":"Bryan DC, Hunt NP. Surgical accuracy in orthognathic surgery. Br J Oral Maxillofac Surg. 1993;31(6):343\u201350. https:\/\/doi.org\/10.1016\/0266-4356(93)90187-2.","journal-title":"Br J Oral Maxillofac Surg"},{"issue":"6","key":"3000_CR18","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1016\/j.ijom.2017.11.007","volume":"47","author":"FS Salmen","year":"2018","unstructured":"Salmen FS, de Oliveira TFM, Gabrielli MAC, Pereira Filho VA, Real Gabrielli MF. Sequencing of bimaxillary surgery in the correction of vertical maxillary excess: retrospective study. Int J Oral Maxillofac Surg. 2018;47(6):708\u201314. https:\/\/doi.org\/10.1016\/j.ijom.2017.11.007.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"6","key":"3000_CR19","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1016\/0278-2391(92)90434-2","volume":"50","author":"E Ellis 3rd","year":"1992","unstructured":"Ellis E 3rd, Tharanon W, Gambrell K. Accuracy of face-bow transfer: effect on surgical prediction and postsurgical result. J Oral Maxillofac Surg. 1992;50(6):562\u20137. https:\/\/doi.org\/10.1016\/0278-2391(92)90434-2.","journal-title":"J Oral Maxillofac Surg"},{"key":"3000_CR20","first-page":"1619","volume":"60","author":"JO Bailey","year":"1981","unstructured":"Bailey JO, Nowlin TP. Accuracy of the Frankfort plane transfer to the Hanau articulator. J Dent Res. 1981;60:1619 DUKE ST, ALEXANDRIA, VA 22314: AMER ASSOC DENTAL RESEARCH.","journal-title":"J Dent Res."},{"issue":"4","key":"3000_CR21","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1016\/j.bjoms.2009.06.018","volume":"48","author":"J Rustemeyer","year":"2010","unstructured":"Rustemeyer J, Groddeck A, Zwerger S, Bremerich A. The accuracy of two-dimensional planning for routine orthognathic surgery. Br J Oral Maxillofac Surg. 2010;48(4):271\u20135. https:\/\/doi.org\/10.1016\/j.bjoms.2009.06.018.","journal-title":"Br J Oral Maxillofac Surg"},{"issue":"5","key":"3000_CR22","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1054\/jcms.2000.0156","volume":"28","author":"G Santler","year":"2000","unstructured":"Santler G. 3-D COSMOS: a new 3-D model based computerised operation simulation and navigation system. J Craniomaxillofac Surg. 2000;28(5):287\u201393. https:\/\/doi.org\/10.1054\/jcms.2000.0156.","journal-title":"J Craniomaxillofac Surg"},{"key":"3000_CR23","doi-asserted-by":"crossref","unstructured":"Karolewska K, Ligaj B. Comparison analysis of titanium alloy Ti6Al4V produced by metallurgical and 3D printing method.\u00a0 AIP Conference Proceedings. 2019;2077. No. 1. AIP Publishing LLC","DOI":"10.1063\/1.5091886"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-023-03000-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-023-03000-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-023-03000-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T11:04:17Z","timestamp":1683111857000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-023-03000-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,3]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["3000"],"URL":"https:\/\/doi.org\/10.1186\/s12903-023-03000-3","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,3]]},"assertion":[{"value":"4 November 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 April 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 May 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was conducted according to the guidelines of the Declaration of Helsinki and approved by the Institutional Review Board (of the Ethics Committee) of Ewha Womans University Mok-Dong Hospital (EUMC 2019\u201306-14). Informed consent was obtained from all subjects and\/or their legal guardian(s).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"255"}}