{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T17:38:41Z","timestamp":1779903521944,"version":"3.53.1"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,7,5]],"date-time":"2023-07-05T00:00:00Z","timestamp":1688515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,7,5]],"date-time":"2023-07-05T00:00:00Z","timestamp":1688515200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The aim of this study is to evaluate the stresses on the supporting bone, implants, and framework materials under masticatory forces in mandibular overdenture prostheses modeled with different framework materials and different implant types, using the Finite Element Analysis (FEA).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>For the finite element modeling, two identical mandibular jaw models were created; one with two standard (diameter:4.1\u00a0mm\/12\u00a0mm length) and the other with two mini-implants (diameter:2.4\u00a0mm\/12\u00a0mm length) were placed in the canine teeth area. The polymethylmethacrylate (PMMA) denture was modeled upon them, supported by Cobalt Chromium alloy (CoCr), Poly-ether ether ketone (PEEK), and Zantex materials with framework. No framework was added as a control model; only PMMA overdenture prosthesis was modeled.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Regardless of the framework materials of the overdenture prostheses, the stress values \u200b\u200bon mini-implants in all models yielded approximately two times higher results comparing to standard implants. More stress transmission was observed in the supporting bone and implants in the control prostheses and overdenture prostheses supported with respectively PEEK, Zantex, CoCr alloy frameworks, respectively. In the framework materials, more stress occurred on CoCr, Zantex and PEEK in that order.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In the light of this study, the use of mini-implants as an alternative to standard implants is not promising in terms of distribution and transmission of chewing stresses. As a framework material, standard rigid metal alloys were found to be more advantageous than polymer materials in terms of stress distribution.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-023-03080-1","type":"journal-article","created":{"date-parts":[[2023,7,5]],"date-time":"2023-07-05T11:03:01Z","timestamp":1688554981000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Biomechanical comparison of different framework materials in mandibular overdenture prosthesis supported with implants of different sizes: a finite element analysis"],"prefix":"10.1186","volume":"23","author":[{"given":"Elifnur","family":"G\u00fczelce S","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,7,5]]},"reference":[{"key":"3080_CR1","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1080\/10255842.2017.1302432","volume":"20","author":"K Solberg","year":"2017","unstructured":"Solberg K, Heinemann F, Pellikaan P, Keilig L, Stark H, Bourauel C, et al. Finite element analysis of different loading conditions for implant-supported overdentures supported by conventional or mini implants. Comput Methods Biomech Engin. 2017;20:770\u201382.","journal-title":"Comput Methods Biomech Engin"},{"key":"3080_CR2","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.prosdent.2020.09.015","volume":"125","author":"PG Patil","year":"2021","unstructured":"Patil PG, Seow LL, Uddanwadikar R, Ukey PD. Biomechanical behavior of mandibular overdenture retained by two standard implants or 2 mini implants: A 3-dimensional finite element analysis. J Prosthet Dent. 2021;125:138.","journal-title":"J Prosthet Dent"},{"key":"3080_CR3","first-page":"601","volume":"17","author":"JS Feine","year":"2002","unstructured":"Feine JS, Carlsson GE, Awad GA, Chehade A, Duncan WJ, Gizani S, et al. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Int J Oral Maxillofac Implants. 2002;17:601\u20132.","journal-title":"Int J Oral Maxillofac Implants."},{"key":"3080_CR4","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1080\/10255842.2015.1067687","volume":"19","author":"SH Chang","year":"2016","unstructured":"Chang SH, Huang SR, Huang SF, Lin CL. Mechanical response comparison in an implant overdenture retained by ball attachments on conventional regular and mini dental implants: a finite element analysis. Comput Methods Biomech Biomed Engin. 2016;19:911\u201321.","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"3080_CR5","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1186\/s40729-017-0092-4","volume":"3","author":"G Sivaramakrishnan","year":"2017","unstructured":"Sivaramakrishnan G, Sridharan K. Comparison of patient satisfaction with mini-implant versus standard diameter implant overdentures: a systematic review and meta-analysis of randomized controlled trials. Int J Implant Dent. 2017;3:29.","journal-title":"Int J Implant Dent"},{"key":"3080_CR6","first-page":"865","volume":"121","author":"G Berger","year":"2019","unstructured":"Berger G, de Pereira LF O, Souza EM. A 3D finite element analysis of glass fiber reinforcement designs on the stress of an implant-supported overdenture. J Prosthet Dent 2019;121:\u2013. 2019;121:865.","journal-title":"J Prosthet Dent. 2019;121:\u2013"},{"key":"3080_CR7","first-page":"43","volume":"9","author":"GV Anehosur","year":"2019","unstructured":"Anehosur GV, Medappa P, Venkitakrishnan VV, Gupta M, Meshramkar RP, Pillai LK, et al. Stress Distribution Analysis at the Bone-Implant Interface Using Four Different Superstructure Materials in an Implant-retained Mandibular Overdenture: A Photoelastic Study. Int J Prosthodont Restor Dent. 2019;9:43\u20136.","journal-title":"Int J Prosthodont Restor Dent"},{"key":"3080_CR8","doi-asserted-by":"publisher","first-page":"22","DOI":"10.4047\/jap.2017.9.1.22","volume":"9","author":"SM Im","year":"2017","unstructured":"Im SM, Huh YH, Cho LR, Park CJ. Comparison of the fracture resistances of glass fiber mesh- and metal meshreinforced maxillary complete denture under dynamic fatigue loading. J Adv Prosthodont. 2017;9:22\u201330.","journal-title":"J Adv Prosthodont"},{"key":"3080_CR9","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1080\/23337931.2018.1457445","volume":"4","author":"PK Vallittu","year":"2018","unstructured":"Vallittu PK. An overview of development and status of fiber-reinforced composites as dental and medical biomaterials. Acta Biomater Odontol Scand. 2018;4:44\u201355.","journal-title":"Acta Biomater Odontol Scand"},{"key":"3080_CR10","doi-asserted-by":"publisher","first-page":"13975","DOI":"10.1038\/s41598-019-50363-1","volume":"9","author":"X Chen","year":"2019","unstructured":"Chen X, Mao B, Zhu Z, Yu J, Lu Y, Zhang Q, et al. A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEK. Sci Rep. 2019;9:13975.","journal-title":"Sci Rep"},{"key":"3080_CR11","doi-asserted-by":"publisher","first-page":"e59111226183","DOI":"10.33448\/rsd-v11i2.26183","volume":"11","author":"ABG Franco","year":"2022","unstructured":"Franco ABG, de Carvalho GAP, Franco AG, Napimoga JTC, Napimoga MH, da Silveira Bueno CE, et al. The biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element Method. Res Soc Dev. 2022;11:e59111226183\u2013e59111226183.","journal-title":"Res Soc Dev"},{"key":"3080_CR12","doi-asserted-by":"publisher","first-page":"e2711729626","DOI":"10.33448\/rsd-v11i7.29626","volume":"11","author":"B Neta","year":"2022","unstructured":"Neta B, Franco AG, de Carvalho GAP. Flexural strength of milled polymer bars, with and without glass fiber reinforcement. Res Soc Dev. 2022;11:e2711729626\u2013e2711729626.","journal-title":"Res Soc Dev"},{"key":"3080_CR13","first-page":"113","volume":"27","author":"E Alexakou","year":"2019","unstructured":"Alexakou E, Damanaki M, Zoidis P, Bakiri E, Mouzis N, Smidt G, et al. PEEK high performance polymers: a review of properties and clinical applications in prosthodontics and restorative dentistry. Eur J Prosthodont Restor Dent. 2019;27:113\u201321.","journal-title":"Eur J Prosthodont Restor Dent"},{"key":"3080_CR14","first-page":"19","volume":"19","author":"G Skirbutis","year":"2017","unstructured":"Skirbutis G, Dzingut\u0117 A, Masili\u016bnait\u0117 V, \u0160ulcait\u0117 G, \u017dilinskas J. A review of PEEK polymer\u2019s properties and its use in prosthodontics. Stomatologija. 2017;19:19\u201323.","journal-title":"Stomatologija"},{"key":"3080_CR15","unstructured":"17.Zantexdental.com.Biofunctionalmaterials.Florida.2022. https:\/\/assets.websitefiles.com\/5f0dca856b8e936001d15d6c\/61dc862d49a8ebc7b39f7ca1_Zantex-Brochure-BFM.pdf."},{"key":"3080_CR16","doi-asserted-by":"publisher","first-page":"e51811629608","DOI":"10.33448\/rsd-v11i6.29608","volume":"11","author":"TGN Fonseca","year":"2022","unstructured":"Fonseca TGN, Franco AG, de Carvalho GAP. Influence of different surface treatments on the shear strength between acrylic resin and two materials: Polyether Ether Ketone (PEEK) \/ ZANTEXR. Res Soc Dev. 2022;11:e51811629608\u2013e51811629608.","journal-title":"Res Soc Dev"},{"key":"3080_CR17","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1016\/j.prosdent.2017.07.016","volume":"119","author":"CF Amaral","year":"2018","unstructured":"Amaral CF, Gomes RS, Garcia RCR, Cury AADB. Stress distribution of single-implant\u2013retained overdenture reinforced with a framework: a finite element analysis study. J Prosthet Dent. 2018;119:791\u20136.","journal-title":"J Prosthet Dent"},{"key":"3080_CR18","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1016\/j.prosdent.2017.12.012","volume":"120","author":"MX Pisani","year":"2018","unstructured":"Pisani MX, Presotto AGC, Mesquita MF, Bar\u00e3o VAR, Kemmoku DT, Cury AADB, et al. Biomechanical behavior of 2-implant- and single-implant-retained mandibular overdentures with conventional or mini implants. J Prosthet Dent. 2018;120:421\u201330.","journal-title":"J Prosthet Dent"},{"key":"3080_CR19","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1016\/j.prosdent.2016.01.031","volume":"116","author":"IAD Radi","year":"2016","unstructured":"Radi IAD, Elmahrouky E. Effect of two different soft liners and thicknesses mediating stress transfer for immediately loaded 2-implant supported mandibular overdentures: A finite element analysis study. J Prosthet Dent. 2016;116:356\u201361.","journal-title":"J Prosthet Dent"},{"key":"3080_CR20","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/j.jdent.2016.11.009","volume":"57","author":"CA Lemos","year":"2017","unstructured":"Lemos CA, Verri FR, Souza Batista VE, J\u00fanior JFS, Mello CC, Pellizzer EP, et al. Complete overdentures retained by mini implants: A systematic review. J Dent. 2017;57:4\u201313.","journal-title":"J Dent"},{"key":"3080_CR21","doi-asserted-by":"publisher","first-page":"1376","DOI":"10.1177\/0022034515601959","volume":"94","author":"RF De Souza","year":"2015","unstructured":"De Souza RF, Ribeiro AB, Della Vecchia MP, Costa L, Cunha TR, Reis AC, et al. Mini vs. standard implants for mandibular overdentures: a randomized trial. J Dent Res. 2015;94:1376\u201384.","journal-title":"J Dent Res."},{"key":"3080_CR22","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1111\/clr.12822","volume":"28","author":"N Enkling","year":"2016","unstructured":"Enkling N, Saftig M, Worni A, Mericske-Stern R, Schimmel M, et al. Schimmel Chewing efficiency, bite force and oral health-related quality of life with narrow diameter implants \u2013 a prospective clinical study: results after one year. Clin Oral Implants Res. 2016;28:476\u201382.","journal-title":"Clin Oral Implants Res"},{"key":"3080_CR23","doi-asserted-by":"publisher","first-page":"1170","DOI":"10.11607\/jomi.3222","volume":"29","author":"E Preoteasa","year":"2014","unstructured":"Preoteasa E, Imre M, Preoteasa CT. A 3-year follow-up study of overdentures retained by mini\u2013dental implants. Int J Oral Maxillofac Implants. 2014;29:1170\u20136.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"3080_CR24","first-page":"105","volume":"8","author":"HW Wiskott","year":"1995","unstructured":"Wiskott HW, Nicholls JI, Belser UC. Belser Stress fatigue: basic principles and prosthodontic implications. Int J Prosthodont. 1995;8:105\u201316.","journal-title":"Int J Prosthodont"},{"key":"3080_CR25","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1016\/S0022-3913(10)60026-1","volume":"103","author":"T Gonda","year":"2010","unstructured":"Gonda T, Maeda Y, Walton JN, MacEntee MI. Fracture incidence in mandibular overdentures retained by one or two implants. J Prosthet Dent. 2010;103:178\u201381.","journal-title":"J Prosthet Dent"},{"key":"3080_CR26","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/S0022-3913(00)70006-0","volume":"83","author":"AH Rodrigues","year":"2000","unstructured":"Rodrigues AH. Metal reinforcement for implant-supported mandibular overdentures. J Prosthet Dent. 2000;83:511\u20133.","journal-title":"J Prosthet Dent"},{"key":"3080_CR27","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1016\/S0022-3913(11)60134-0","volume":"106","author":"RN Rached","year":"2011","unstructured":"Rached RN, De Souza EM, Dyer SR, Ferracane JL. Dynamic and static strength of an implant-supported overdenture model reinforced with metal and nonmetal strengtheners. J Prosthet Dent. 2011;106:297\u2013304.","journal-title":"J Prosthet Dent"},{"key":"3080_CR28","doi-asserted-by":"publisher","first-page":"340","DOI":"10.11607\/ijp.3421","volume":"26","author":"T Gonda","year":"2013","unstructured":"Gonda T, Dong J, Maeda Y. Stress analysis of an overdenture using the finite element method. Int J Prosthodont. 2013;26:340\u20132.","journal-title":"Int J Prosthodont"},{"key":"3080_CR29","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.msec.2017.02.034","volume":"75","author":"RS Gomes","year":"2017","unstructured":"Gomes RS, Bergamo ETP, Bordin D, Cury AADB. The substitution of the implant and abutment for their analogs in mechanical studies: In vitro and in silico analysis. Mater Sci Eng C. 2017;75:50\u20134.","journal-title":"Mater Sci Eng C"},{"key":"3080_CR30","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1590\/0103-6440201300258","volume":"26","author":"LB Durand","year":"2015","unstructured":"Durand LB, Guimar\u00e3es JB, Monteiro Junior S, Baratieri LN. Effect of ceramic thickness and composite bases on stress distribution of inlays - A finite element analysis. Braz Dent J. 2015;26:146\u201351.","journal-title":"Braz Dent J"},{"key":"3080_CR31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4103\/1735-3327.310031","volume":"18","author":"K Kelkar","year":"2021","unstructured":"Kelkar K, Bhat V, Hegde C. Finite element analysis of the effect of framework materials at the bone\u2013implant interface in the all-on-four implant system. Dent Res J. 2021;18:1\u20137.","journal-title":"Dent Res J"},{"key":"3080_CR32","doi-asserted-by":"publisher","first-page":"446","DOI":"10.4103\/jispcd.JISPCD_183_18","volume":"8","author":"OAL Jaros","year":"2018","unstructured":"Jaros OAL, De Carvalho GAP, Franco ABG, Kreve S, Lopes PAB, Dias SC, et al. Biomechanical behavior of an implant system using polyether ether ketone bar: Finite element analysis. J Int Soc Prev Community Dent. 2018;8:446\u201350.","journal-title":"J Int Soc Prev Community Dent"},{"key":"3080_CR33","doi-asserted-by":"publisher","first-page":"107","DOI":"10.11607\/jomi.7255","volume":"34","author":"D Sirandoni","year":"2006","unstructured":"Sirandoni D, Leal E, Weber B, Noritomi PY, Fuentes R, Borie E. Effect of different framework materials in implant-supported fixed mandibular prostheses: a finite element analysis. Int J Oral Maxillofac Implants. 2006;34:107\u201314.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"3080_CR34","doi-asserted-by":"publisher","first-page":"1817","DOI":"10.21608\/edj.2020.33441.1160","volume":"66","author":"SA Kortam","year":"2020","unstructured":"Kortam SA. Metal versus Poly ether-ether ketone (PEEK) framework reinforcements for maxillary palateless ball retained implant overdentures. One year clinical and radiographic outcomes. Egypt Dent J. 2020;66:1817\u201328.","journal-title":"Egypt Dent J."},{"issue":"8","key":"3080_CR35","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1111\/jopr.12747","volume":"27","author":"P Zoidis","year":"2018","unstructured":"Zoidis P. Polyetheretherketone overlay prosthesis over high noble ball attachments to overcome base metal sensitivity: a clinical report. J Prosthodont. 2018;27(8):688\u201393.","journal-title":"J Prosthodont"},{"key":"3080_CR36","doi-asserted-by":"publisher","first-page":"581","DOI":"10.11607\/ijp.5369","volume":"30","author":"K Lee","year":"2017","unstructured":"Lee K, Shin S, Lee S, Kim JH, Lee JY. Comparative evaluation of a four-implant-supported polyetherketoneketone framework prosthesis: a three-dimensional finite element analysis based on cone beam computed tomography and computer-aided design. Int J Prosthodont. 2017;30:581\u20135.","journal-title":"Int J Prosthodont"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-023-03080-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-023-03080-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-023-03080-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,5]],"date-time":"2023-07-05T11:04:16Z","timestamp":1688555056000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-023-03080-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,5]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["3080"],"URL":"https:\/\/doi.org\/10.1186\/s12903-023-03080-1","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2604708\/v1","asserted-by":"object"}]},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,5]]},"assertion":[{"value":"19 February 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 May 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 July 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study has been approved by from the Hamidiye Scientific Research Ethics Committee of University of Health Sciences (no:22\/447). We confirm that all methods are performed in accordance with relevant guidelines and regulations. Ethics Committee of University of Health Sciences Hamidiye Scientific Research Ethics waived the need for informed consent as all the work is done in computer environment.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"450"}}