{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T14:57:26Z","timestamp":1787065046993,"version":"build-2736575974"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,11,8]],"date-time":"2023-11-08T00:00:00Z","timestamp":1699401600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,11,8]],"date-time":"2023-11-08T00:00:00Z","timestamp":1699401600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100007446","name":"King Khalid University","doi-asserted-by":"crossref","award":["RGP2\/452\/44"],"award-info":[{"award-number":["RGP2\/452\/44"]}],"id":[{"id":"10.13039\/501100007446","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>This study aimed to determine the relative positioning accuracy of multiple implants utilizing four distinct types of splinting materials.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      The purpose of this in-vitro study was to compare the precision of four splinting materials in an open tray impression technique in multiple implant situations. Based on the material used for splinting, four groups were made (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200940)- Group A: Conventional Method, Group B: Prefabricated Pattern Resin Framework, Group C: Prefabricated Metal Framework, Group D: Light Cured Pattern Resin, these groups were compared with the master model. A heat-cured clear acrylic resin and a master model were constructed. A pilot milling machine drill was used to drill four parallel holes in the anterior and premolar regions, which were later labeled as A, B, C, and D positions from right to left. Then, sequential drilling was carried out, and four 3.75\u2011mm diameter and 13-mm long ADIN implant analogs with internal hex were placed in the acrylic model using a surveyor for proper orientation. The impression posts were then manually screwed to the implant analogs using an open tray, and they were secured to the implants using 10\u00a0mm flat head guide pins with a 15\u00a0N.cm torque. 10 Open tray polyether impressions were made, and casts were poured. Each splinting method\u2019s distortion values were measured using a coordinate measuring machine capable of recordings in the X-, Y-, and Z-axes. Comparison of mean distances for X1, X2, and X3 was made using the Kruskal-Wallis test, and Pairwise comparison was done using Post Hoc Tukey\u2019s Test.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The differences between the groups were significant when assessing the distances X1, X2, and X3 (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05). The comparison of deviations between the groups revealed a statistically significant difference (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05) for the deviation distance X3 but not for the deviation distances X1 and X2. For distance Y1, the difference between the groups was statistically significant (p0.05), but it was not significant for distances Y2 and Y3. A statistically significant difference was seen in the comparison between the groups (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05) for the deviation distances Y1, Y2, and Y3. The results were statistically significant for the distance Z1 comparisons, namely, control vs. Group A (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.012), control vs. Group B (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.049), control vs. Group C (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.048), and control vs. Group D (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.021), and for distance Z3 comparison for control vs. Group A (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.033). The results were statistically insignificant for the distance Z2 comparisons (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&gt;\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>All splinting materials produced master casts with measurements in close proximity to the reference model. However, prefabricated pattern resin bars splinting showed the highest accuracy among the studied techniques. The most recent splinting techniques using prefabricated metal framework and light-cure pattern resin showed similar accuracy.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-023-03583-x","type":"journal-article","created":{"date-parts":[[2023,11,8]],"date-time":"2023-11-08T17:01:42Z","timestamp":1699462902000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Comparative evaluation of open tray impression technique: investigating the precision of four splinting materials in multiple implants"],"prefix":"10.1186","volume":"23","author":[{"given":"Priyanka","family":"Patil","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V. N.V","family":"Madhav","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdulkhaliq Ali F.","family":"Alshadidi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ravinder S.","family":"Saini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lujain Ibrahim N.","family":"Aldosari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Artak","family":"Heboyan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seyed Ali","family":"Mosaddad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saeed Awod","family":"Bin Hassan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saurabh","family":"Chaturvedi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,11,8]]},"reference":[{"key":"3583_CR1","doi-asserted-by":"publisher","unstructured":"Sartoretto SC, Shibli JA, Javid K, Cotrim K, Canabarro A, Louro RS, Lowenstein A, Mour\u00e3o CF, Moraschini V. Comparing the Long-Term Success Rates of Tooth Preservation and Dental Implants: a critical review. J Funct Biomater.\u00a02023;14(3):142. https:\/\/doi.org\/10.3390\/jfb14030142.","DOI":"10.3390\/jfb14030142"},{"issue":"4","key":"3583_CR2","doi-asserted-by":"publisher","first-page":"128","DOI":"10.4047\/jap.2010.2.4.128","volume":"2","author":"SH Jo","year":"2010","unstructured":"Jo SH, Kim KI, Seo JM, Song KY, Park JM, Ahn SG. Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study. J Adv Prosthodont. 2010;2(4):128\u201333.","journal-title":"J Adv Prosthodont"},{"issue":"4","key":"3583_CR3","first-page":"123","volume":"108","author":"DY Ng","year":"2012","unstructured":"Ng DY, Wong AY, Liston PN. Multidisciplinary approach to implants: a review. N Z Dent J. 2012;108(4):123\u20138.","journal-title":"N Z Dent J"},{"issue":"5s","key":"3583_CR4","first-page":"e1","volume":"117","author":"The Glossary of Prosthodontic Terms","year":"2017","unstructured":"The Glossary of Prosthodontic Terms. Ninth Edition. J Prosthet Dent. 2017;117(5s):e1\u2013e105.","journal-title":"J Prosthet Dent"},{"issue":"2","key":"3583_CR5","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1097\/00008505-200104000-00003","volume":"10","author":"S Sahin","year":"2001","unstructured":"Sahin S, Cehreli MC. The significance of passive framework fit in implant prosthodontics: current status. Implant Dent. 2001;10(2):85\u201392.","journal-title":"Implant Dent"},{"issue":"2","key":"3583_CR6","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1586\/erd.09.74","volume":"7","author":"CN Elias","year":"2010","unstructured":"Elias CN, Meirelles L. Improving osseointegration of dental implants. Expert Rev Med Devices. 2010;7(2):241\u201356.","journal-title":"Expert Rev Med Devices"},{"issue":"2","key":"3583_CR7","doi-asserted-by":"publisher","first-page":"808","DOI":"10.1016\/j.jds.2023.01.012","volume":"18","author":"H Arikan","year":"2023","unstructured":"Arikan H, Muhtarogullari M, Uzel SM, Guncu MB, Aktas G, Marshall LS, et al. Accuracy of digital impressions for implant-supported complete-arch prosthesis when using an auxiliary geometry device. J Dent Sci. 2023;18(2):808\u201313.","journal-title":"J Dent Sci"},{"issue":"1","key":"3583_CR8","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1007\/s13191-013-0343-x","volume":"14","author":"MM Buzayan","year":"2014","unstructured":"Buzayan MM, Yunus NB. Passive Fit in Screw retained multi-unit Implant Prosthesis understanding and achieving: a review of the literature. J Indian Prosthodont Soc. 2014;14(1):16\u201323.","journal-title":"J Indian Prosthodont Soc"},{"issue":"1","key":"3583_CR9","doi-asserted-by":"publisher","first-page":"29","DOI":"10.4103\/0974-6781.190384","volume":"6","author":"RY Shankar","year":"2016","unstructured":"Shankar RY, Sahoo S, Krishna MH, Kumar PS, Kumar TS, Narula S. Accuracy of implant impressions using various impression techniques and impression materials. J Dent Implant. 2016;6(1):29\u201336.","journal-title":"J Dent Implant"},{"issue":"3","key":"3583_CR10","doi-asserted-by":"publisher","first-page":"239","DOI":"10.4103\/jips.jips_27_18","volume":"18","author":"TM Joseph","year":"2018","unstructured":"Joseph TM, Ravichandran R, Lylajam S, Viswabharan P, Janardhanan K, Rajeev S. Evaluation of positional accuracy in multiple implants using four different splinting materials: an in vitro study. J Indian Prosthodont Soc. 2018;18(3):239\u201347.","journal-title":"J Indian Prosthodont Soc"},{"issue":"6","key":"3583_CR11","first-page":"1153","volume":"25","author":"MA Del Acqua","year":"2010","unstructured":"Del Acqua MA, Chavez AM, Castanharo SM, Compagnoni MA, Mollo Fde A Jr. The effect of splint material rigidity in implant impression techniques. Int J Oral Maxillofac Implants. 2010;25(6):1153\u20138.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"2","key":"3583_CR12","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1111\/j.1708-8208.2009.00241.x","volume":"14","author":"N Rashidan","year":"2012","unstructured":"Rashidan N, Alikhasi M, Samadizadeh S, Beyabanaki E, Kharazifard MJ. Accuracy of implant impressions with different impression coping types and shapes. Clin Implant Dent Relat Res. 2012;14(2):218\u201325.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"1","key":"3583_CR13","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/0022-3913(78)90155-5","volume":"40","author":"PC Moon","year":"1978","unstructured":"Moon PC, Eshleman JR, Douglas HB, Garrett SG. Comparison of accuracy of soldering indices for fixed prostheses. J Prosthet Dent. 1978;40(1):35\u20138.","journal-title":"J Prosthet Dent"},{"key":"3583_CR14","doi-asserted-by":"publisher","first-page":"2555","DOI":"10.2147\/IJN.S246764","volume":"15","author":"IX Yin","year":"2020","unstructured":"Yin IX, Zhang J, Zhao IS, Mei ML, Li Q, Chu CH. The Antibacterial mechanism of silver nanoparticles and its application in Dentistry. Int J Nanomedicine. 2020;15:2555\u201362.","journal-title":"Int J Nanomedicine"},{"issue":"4","key":"3583_CR15","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1016\/j.prosdent.2018.04.006","volume":"120","author":"FR Homsy","year":"2018","unstructured":"Homsy FR, \u00d6zcan M, Khoury M, Majzoub ZAK. Comparison of fit accuracy of pressed lithium disilicate inlays fabricated from wax or resin patterns with conventional and CAD-CAM technologies. J Prosthet Dent. 2018;120(4):530\u20136.","journal-title":"J Prosthet Dent"},{"issue":"3","key":"3583_CR16","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1097\/ID.0b013e3182920dc5","volume":"22","author":"F Mart\u00ednez-Rus","year":"2013","unstructured":"Mart\u00ednez-Rus F, Garc\u00eda C, Santamar\u00eda A, \u00d6zcan M, Prad\u00edes G. Accuracy of definitive casts using 4 implant-level impression techniques in a scenario of multi-implant system with different implant angulations and subgingival alignment levels. Implant Dent. 2013;22(3):268\u201376.","journal-title":"Implant Dent"},{"issue":"4","key":"3583_CR17","first-page":"517","volume":"19","author":"K Ak\u00e7a","year":"2004","unstructured":"Ak\u00e7a K, Cehreli MC. Accuracy of 2 impression techniques for ITI implants. Int J Oral Maxillofac Implants. 2004;19(4):517\u201323.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"3","key":"3583_CR18","doi-asserted-by":"publisher","first-page":"40","DOI":"10.9790\/0853-13354045","volume":"13","author":"A Pandey","year":"2014","unstructured":"Pandey A, Mehtra A. Comparative study of dimensional stability and accuracy of various elastomaric materials. IOSR J Dent Med Sci. 2014;13(3):40\u20135.","journal-title":"IOSR J Dent Med Sci"},{"issue":"5","key":"3583_CR19","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1016\/0022-3913(93)90160-P","volume":"69","author":"JA Inturregui","year":"1993","unstructured":"Inturregui JA, Aquilino SA, Ryther JS, Lund PS. Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent. 1993;69(5):503\u20139.","journal-title":"J Prosthet Dent"},{"issue":"3","key":"3583_CR20","first-page":"371","volume":"12","author":"T Ma","year":"1997","unstructured":"Ma T, Nicholls JI, Rubenstein JE. Tolerance measurements of various implant components. Int J Oral Maxillofac Implants. 1997;12(3):371\u20135.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"1","key":"3583_CR21","first-page":"39","volume":"23","author":"HJ Wenz","year":"2008","unstructured":"Wenz HJ, Hertrampf K. Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection. Int J Oral Maxillofac Implants. 2008;23(1):39\u201347.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"2","key":"3583_CR22","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1097\/ID.0b013e3180587b3f","volume":"16","author":"LM Cabral","year":"2007","unstructured":"Cabral LM, Guedes CG. Comparative analysis of 4 impression techniques for implants. Implant Dent. 2007;16(2):187\u201394.","journal-title":"Implant Dent"},{"issue":"2","key":"3583_CR23","first-page":"192","volume":"19","author":"MM Naconecy","year":"2004","unstructured":"Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A. Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. Int J Oral Maxillofac Implants. 2004;19(2):192\u20138.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"2","key":"3583_CR24","first-page":"112","volume":"12","author":"D Assif","year":"1992","unstructured":"Assif D, Fenton A, Zarb G, Schmitt A. Comparative accuracy of implant impression procedures. Int J Periodontics Restorative Dent. 1992;12(2):112\u201321.","journal-title":"Int J Periodontics Restorative Dent"},{"issue":"4","key":"3583_CR25","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1097\/01.id.0000144509.58901.f7","volume":"13","author":"WG Assuncao","year":"2004","unstructured":"Assuncao WG, Filho HG, Zaniquelli O. Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent. 2004;13(4):358\u201366.","journal-title":"Implant Dent"},{"issue":"2","key":"3583_CR26","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1067\/mpr.2003.15","volume":"89","author":"P Vigolo","year":"2003","unstructured":"Vigolo P, Majzoub Z, Cordioli G. Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent. 2003;89(2):186\u201392.","journal-title":"J Prosthet Dent"},{"issue":"2","key":"3583_CR27","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.prosdent.2006.06.004","volume":"96","author":"BM Chang","year":"2006","unstructured":"Chang BM, Wright RF. A solid bar splint for open-tray implant impression technique. J Prosthet Dent. 2006;96(2):143\u20134.","journal-title":"J Prosthet Dent"},{"issue":"2","key":"3583_CR28","first-page":"216","volume":"11","author":"D Assif","year":"1996","unstructured":"Assif D, Marshak B, Schmidt A. Accuracy of implant impression techniques. Int J Oral Maxillofac Implants. 1996;11(2):216\u201322.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"4","key":"3583_CR29","doi-asserted-by":"publisher","first-page":"177","DOI":"10.4047\/jap.2011.3.4.177","volume":"3","author":"SJ Lee","year":"2011","unstructured":"Lee SJ, Cho SB. Accuracy of five implant impression technique: effect of splinting materials and methods. J Adv Prosthodont. 2011;3(4):177\u201385.","journal-title":"J Adv Prosthodont"},{"issue":"5","key":"3583_CR30","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1016\/0022-3913(92)90192-D","volume":"68","author":"WW Chee","year":"1992","unstructured":"Chee WW, Donovan TE. Polyvinyl siloxane impression materials: a review of properties and techniques. J Prosthet Dent. 1992;68(5):728\u201332.","journal-title":"J Prosthet Dent"},{"issue":"4","key":"3583_CR31","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/S0022-3913(08)60208-5","volume":"100","author":"H Lee","year":"2008","unstructured":"Lee H, So JS, Hochstedler JL, Ercoli C. The accuracy of implant impressions: a systematic review. J Prosthet Dent. 2008;100(4):285\u201391.","journal-title":"J Prosthet Dent"},{"issue":"6","key":"3583_CR32","first-page":"1267","volume":"26","author":"P Papaspyridakos","year":"2011","unstructured":"Papaspyridakos P, Lal K, White GS, Weber HP, Gallucci GO. Effect of splinted and nonsplinted impression techniques on the accuracy of fit of fixed implant prostheses in edentulous patients: a comparative study. Int J Oral Maxillofac Implants. 2011;26(6):1267\u201372.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"2","key":"3583_CR33","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1111\/jerd.12274","volume":"29","author":"P Papaspyridakos","year":"2017","unstructured":"Papaspyridakos P, Kim YJ, Finkelman M, El-Rafie K, Weber HP. Digital evaluation of three splinting materials used to Fabricate Verification Jigs for full-Arch Implant prostheses: a comparative study. J Esthet Restor Dent. 2017;29(2):102\u20139.","journal-title":"J Esthet Restor Dent"},{"issue":"2","key":"3583_CR34","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.prosdent.2014.02.006","volume":"112","author":"SB Gibbs","year":"2014","unstructured":"Gibbs SB, Versluis A, Tantbirojn D, Ahuja S. Comparison of polymerization shrinkage of pattern resins. J Prosthet Dent. 2014;112(2):293\u20138.","journal-title":"J Prosthet Dent"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-023-03583-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-023-03583-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-023-03583-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,8]],"date-time":"2023-11-08T17:03:59Z","timestamp":1699463039000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-023-03583-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,8]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["3583"],"URL":"https:\/\/doi.org\/10.1186\/s12903-023-03583-x","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,8]]},"assertion":[{"value":"20 May 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 October 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 November 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"844"}}