{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T23:52:20Z","timestamp":1779321140752,"version":"3.51.4"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,9,13]],"date-time":"2024-09-13T00:00:00Z","timestamp":1726185600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,9,13]],"date-time":"2024-09-13T00:00:00Z","timestamp":1726185600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009827","name":"Alexandria University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100009827","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Partial coverage concepts have met the main goal of conservative dentistry. Vonlays, which combine features of veneers and onlays, are a recent alternative to full coverage designs and overlay partial coverage restorations. This in vitro study was conducted to compare the fracture resistance of the newly introduced pressable zirconia-reinforced lithium silicate with pressable lithium disilicate ceramic and to determine the optimal preparation design for partial coverage on upper premolars.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Fifty-two duplicated epoxy resin dies were prepared following vonlay and overlay preparation guidelines. For each preparation (<jats:italic>n<\/jats:italic>\u2009=\u200926), the specimens were divided into two subgroups to be restored with lithium disilicate (IPS e.max Press) or zirconia-reinforced lithium silicate (Vita Ambria) (<jats:italic>n<\/jats:italic>\u2009=\u200913 each). Ceramic vonlays and overlays were bonded using dual cure resin cement, subjected to thermomechanical fatigue, and the load to fracture was tested by using a universal testing machine. The specimens were fractographically analyzed via scanning electron microscopy (SEM). The normality of the fracture resistance data was checked using the Shapiro\u2012Wilk test and Q\u2012Q plots, and two-way ANOVA was used to assess the effect of the type of preparation and ceramic material on the fracture resistance.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The group of overlays restored with zirconia-reinforced lithium silicate showed the highest mean fracture load (1218.69\u00a0N), while the group of vonlays restored with lithium disilicate had the lowest mean fracture resistance (967.15\u00a0N). The effect of preparation design and material type on fracture resistance was significant for both factors, <jats:italic>p<\/jats:italic>\u2009=\u20090.003 and <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.0001, respectively. Different features of the fracture surfaces, such as arrest lines, hackles, and directions of crack propagation, were observed.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Zirconia-reinforced lithium silicate exhibited greater resistance to fracture compared to lithium disilicate, making it a potential substitute for partial coverage restorations. Additionally, the overlay showed superior fracture resistance when compared to the vonlay preparation design.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12903-024-04809-2","type":"journal-article","created":{"date-parts":[[2024,9,13]],"date-time":"2024-09-13T08:02:37Z","timestamp":1726214557000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Fracture resistance and fractographic analysis of pressable glass-ceramics with different partial coverage designs for maxillary premolars"],"prefix":"10.1186","volume":"24","author":[{"given":"Abdelaziz M.","family":"Abdelaal","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hany A.","family":"Kehela","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmed A.","family":"Holiel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,9,13]]},"reference":[{"issue":"1","key":"4809_CR1","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1186\/s12903-023-02808-3","volume":"23","author":"L Singer","year":"2023","unstructured":"Singer L, Fouda A, Bourauel C. Biomimetic approaches and materials in restorative and regenerative dentistry: review article. BMC Oral Health. 2023;23(1):105.","journal-title":"BMC Oral Health"},{"issue":"6","key":"4809_CR2","doi-asserted-by":"publisher","first-page":"624","DOI":"10.2341\/19-251-L","volume":"45","author":"I Thainimit","year":"2020","unstructured":"Thainimit I, Totiam P, Wayakanon K. Fracture resistance of remaining buccal cusps in Maxillary Premolar Ceramic Onlay restorations. Oper Dent. 2020;45(6):624\u201331.","journal-title":"Oper Dent"},{"issue":"6","key":"4809_CR3","first-page":"543","volume":"23","author":"P Magne","year":"2003","unstructured":"Magne P, Belser UC. Porcelain versus composite inlays\/onlays: effects of mechanical loads on stress distribution, adhesion, and crown flexure. Int J Periodontics Restor Dent. 2003;23(6):543\u201355.","journal-title":"Int J Periodontics Restor Dent"},{"issue":"9","key":"4809_CR4","first-page":"729","volume":"40","author":"P Magne","year":"2009","unstructured":"Magne P, Knezevic A. Influence of overlay restorative materials and load cusps on the fatigue resistance of endodontically treated molars. Quintessence Int (Berlin Germany: 1985). 2009;40(9):729\u201337.","journal-title":"Quintessence Int (Berlin Germany: 1985)"},{"issue":"2","key":"4809_CR5","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/S0022-3913(07)60042-0","volume":"98","author":"B Dejak","year":"2007","unstructured":"Dejak B, Mlotkowski A, Romanowicz M. Strength estimation of different designs of ceramic inlays and onlays in molars based on the Tsai-Wu failure criterion. J Prosthet Dent. 2007;98(2):89\u2013100.","journal-title":"J Prosthet Dent"},{"issue":"1","key":"4809_CR6","first-page":"70","volume":"25","author":"US Beier","year":"2012","unstructured":"Beier US, Kapferer I, Dumfahrt H. Clinical long-term evaluation and failure characteristics of 1,335 all-ceramic restorations. Int J Prosthodont. 2012;25(1):70\u20138.","journal-title":"Int J Prosthodont"},{"issue":"2","key":"4809_CR7","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/S0300-5712(96)00008-5","volume":"25","author":"J Valderhaug","year":"1997","unstructured":"Valderhaug J, Jokstad A, Ambjornsen E, Norheim PW. Assessment of the periapical and clinical status of crowned teeth over 25 years. J Dent. 1997;25(2):97\u2013105.","journal-title":"J Dent"},{"issue":"4","key":"4809_CR8","first-page":"282","volume":"36","author":"EA McLaren","year":"2015","unstructured":"McLaren EA, Figueira J, Goldstein RE. Vonlays: a conservative esthetic alternative to full-coverage crowns. Compend Contin Educ Dent. 2015;36(4):282.","journal-title":"Compend Contin Educ Dent"},{"issue":"3","key":"4809_CR9","doi-asserted-by":"publisher","first-page":"734","DOI":"10.22271\/oral.2020.v6.i3k.1029","volume":"6","author":"M Elsayed","year":"2020","unstructured":"Elsayed M, Sherif R, El-khodary N. Fracture resistance of Vita suprinity versus IPS e.max CAD vonlays restoring premolars (an in vitro study). Int J Appl Dent Sci. 2020;6(3):734\u201341.","journal-title":"Int J Appl Dent Sci"},{"issue":"4","key":"4809_CR10","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1016\/S0022-3913(13)60374-1","volume":"110","author":"PC Guess","year":"2013","unstructured":"Guess PC, Schultheis S, Wolkewitz M, Zhang Y, Strub JR. Influence of preparation design and ceramic thicknesses on fracture resistance and failure modes of premolar partial coverage restorations. J Prosthet Dent. 2013;110(4):264\u201373.","journal-title":"J Prosthet Dent"},{"issue":"1","key":"4809_CR11","doi-asserted-by":"publisher","first-page":"16599","DOI":"10.1038\/s41598-022-21167-7","volume":"12","author":"W Channarong","year":"2022","unstructured":"Channarong W, Lohawiboonkij N, Jaleyasuthumkul P, Ketpan K, Duangrattanaprathip N, Wayakanon K. Fracture resistance of bonded ceramic overlay restorations prepared in various designs. Sci Rep. 2022;12(1):16599.","journal-title":"Sci Rep"},{"key":"4809_CR12","doi-asserted-by":"publisher","first-page":"103346","DOI":"10.1016\/j.jdent.2020.103346","volume":"97","author":"X Huang","year":"2020","unstructured":"Huang X, Zou L, Yao R, Wu S, Li Y. Effect of preparation design on the fracture behavior of ceramic occlusal veneers in maxillary premolars. J Dent. 2020;97:103346.","journal-title":"J Dent"},{"issue":"9","key":"4809_CR13","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1038\/s41415-022-4242-6","volume":"232","author":"R Giordano Ii","year":"2022","unstructured":"Giordano Ii R. Ceramics overview. Br Dent J. 2022;232(9):658\u201363.","journal-title":"Br Dent J"},{"key":"4809_CR14","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/j.jmbbm.2017.06.013","volume":"74","author":"M Al-Akhali","year":"2017","unstructured":"Al-Akhali M, Chaar MS, Elsayed A, Samran A, Kern M. Fracture resistance of ceramic and polymer-based occlusal veneer restorations. J Mech Behav Biomed Mater. 2017;74:245\u201350.","journal-title":"J Mech Behav Biomed Mater"},{"key":"4809_CR15","first-page":"682","volume":"31","author":"E McLaren","year":"2010","unstructured":"McLaren E, Giordano R. Ceramics overview: classification by microstructure and processing methods. Compend Contin Educ Dent. 2010;31:682\u20134.","journal-title":"Compend Contin Educ Dent"},{"issue":"7","key":"4809_CR16","doi-asserted-by":"publisher","first-page":"908","DOI":"10.1016\/j.dental.2016.03.013","volume":"32","author":"SE Elsaka","year":"2016","unstructured":"Elsaka SE, Elnaghy AM. Mechanical properties of zirconia reinforced lithium silicate glass-ceramic. Dent Mater. 2016;32(7):908\u201314.","journal-title":"Dent Mater"},{"issue":"11","key":"4809_CR17","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.1016\/j.dental.2015.08.154","volume":"31","author":"V Preis","year":"2015","unstructured":"Preis V, Behr M, Hahnel S, Rosentritt M. Influence of cementation on in vitro performance, marginal adaptation and fracture resistance of CAD\/CAM-fabricated ZLS molar crowns. Dent Mater. 2015;31(11):1363\u20139.","journal-title":"Dent Mater"},{"issue":"1","key":"4809_CR18","doi-asserted-by":"publisher","first-page":"e259","DOI":"10.1111\/jopr.12684","volume":"28","author":"TA Hamza","year":"2019","unstructured":"Hamza TA, Sherif RM. Fracture resistance of monolithic Glass-ceramics Versus Bilayered Zirconia-based restorations. J Prosthodont. 2019;28(1):e259\u201364.","journal-title":"J Prosthodont"},{"issue":"16","key":"4809_CR19","doi-asserted-by":"publisher","first-page":"2528","DOI":"10.3390\/ma12162528","volume":"12","author":"O Ghajghouj","year":"2019","unstructured":"Ghajghouj O, Tasar-Faruk S. Evaluation of Fracture Resistance and Microleakage of endocrowns with different Intracoronal depths and restorative materials luted with various Resin cements. Mater (Basel). 2019;12(16):2528.","journal-title":"Mater (Basel)"},{"issue":"6","key":"4809_CR20","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1016\/j.dental.2017.03.004","volume":"33","author":"SS Scherrer","year":"2017","unstructured":"Scherrer SS, Lohbauer U, Della Bona A, Vichi A, Tholey MJ, Kelly JR, van Noort R, Cesar PF. ADM guidance-Ceramics: guidance to the use of fractography in failure analysis of brittle materials. Dent Mater. 2017;33(6):599\u2013620.","journal-title":"Dent Mater"},{"issue":"11","key":"4809_CR21","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1016\/j.dental.2017.09.006","volume":"33","author":"JR Kelly","year":"2017","unstructured":"Kelly JR, Cesar PF, Scherrer SS, Della Bona A, van Noort R, Tholey M, Vichi A, Lohbauer U. ADM guidance-ceramics: fatigue principles and testing. Dent Mater. 2017;33(11):1192\u2013204.","journal-title":"Dent Mater"},{"issue":"1","key":"4809_CR22","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.prosdent.2023.04.013","volume":"130","author":"M Arshad","year":"2023","unstructured":"Arshad M, Hassantash S, Chinian S, Sadr A, Habibzadeh S. Fracture strength and three-dimensional marginal evaluation of biocompatible high-performance polymer versus pressed lithium disilicate crowns. J Prosthet Dent. 2023;130(1):132. e131-132 e139.","journal-title":"J Prosthet Dent"},{"key":"4809_CR23","unstructured":"Rosner B. Fundamentals of biostatistics Nelson Education 2015."},{"key":"4809_CR24","unstructured":"Faul F, Erdfelder E, Lang AG. A. B: G*Power for Windows (version 3197) (Computer software) Germany 2020."},{"issue":"7","key":"4809_CR25","doi-asserted-by":"publisher","first-page":"123","DOI":"10.3390\/dj10070123","volume":"10","author":"NA Gavounelis","year":"2022","unstructured":"Gavounelis NA, Gogola CC, Halazonetis DJ. The effect of scanning strategy on Intraoral scanner\u2019s accuracy. Dent J (Basel). 2022;10(7):123.","journal-title":"Dent J (Basel)"},{"issue":"4","key":"4809_CR26","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1016\/j.prosdent.2018.06.006","volume":"121","author":"A Goujat","year":"2019","unstructured":"Goujat A, Abouelleil H, Colon P, Jeannin C, Pradelle N, Seux D, Grosgogeat B. Marginal and internal fit of CAD-CAM inlay\/onlay restorations: a systematic review of in vitro studies. J Prosthet Dent. 2019;121(4):590\u2013e597593.","journal-title":"J Prosthet Dent"},{"issue":"11","key":"4809_CR27","doi-asserted-by":"publisher","first-page":"e281","DOI":"10.1016\/j.dental.2013.08.210","volume":"29","author":"S Posritong","year":"2013","unstructured":"Posritong S, Borges AL, Chu TM, Eckert GJ, Bottino MA, Bottino MC. The impact of hydrofluoric acid etching followed by unfilled resin on the biaxial strength of a glass-ceramic. Dent Mater. 2013;29(11):e281\u2013290.","journal-title":"Dent Mater"},{"issue":"2","key":"4809_CR28","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1111\/jopr.12376","volume":"25","author":"N Nawafleh","year":"2016","unstructured":"Nawafleh N, Hatamleh M, Elshiyab S, Mack F. Lithium disilicate restorations fatigue testing parameters: a systematic review. J Prosthodont. 2016;25(2):116\u201326.","journal-title":"J Prosthodont"},{"issue":"1","key":"4809_CR29","doi-asserted-by":"publisher","first-page":"E1","DOI":"10.2341\/17-262-L","volume":"44","author":"VA Mergulhao","year":"2019","unstructured":"Mergulhao VA, de Mendonca LS, de Albuquerque MS, Braz R. Fracture resistance of endodontically treated maxillary premolars restored with different methods. Oper Dent. 2019;44(1):E1\u201311.","journal-title":"Oper Dent"},{"issue":"5","key":"4809_CR30","doi-asserted-by":"publisher","first-page":"2975","DOI":"10.3390\/ma3052975","volume":"3","author":"MN Aboushelib","year":"2010","unstructured":"Aboushelib MN. Long term fatigue behavior of Zirconia Based Dental ceramics. Materials. 2010;3(5):2975\u201385.","journal-title":"Materials"},{"issue":"1","key":"4809_CR31","first-page":"20","volume":"30","author":"A Shams","year":"2022","unstructured":"Shams A, Sakrana AA, Abo El-Farag SA, Ozcan M. Assessment of Biomechanical Behavior of Endodontically treated Premolar Teeth restored with Novel Endocrown System. Eur J Prosthodont Restor Dent. 2022;30(1):20\u201335.","journal-title":"Eur J Prosthodont Restor Dent"},{"issue":"5","key":"4809_CR32","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/S0109-5641(99)00057-3","volume":"15","author":"FJ Burke","year":"1999","unstructured":"Burke FJ. Fracture resistance of teeth restored with dentin-bonded crowns constructed in a leucite-reinforced ceramic. Dent Mater. 1999;15(5):359\u201362.","journal-title":"Dent Mater"},{"issue":"4","key":"4809_CR33","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1007\/s00784-011-0606-z","volume":"16","author":"MT Yucel","year":"2012","unstructured":"Yucel MT, Yondem I, Aykent F, Eraslan O. Influence of the supporting die structures on the fracture strength of all-ceramic materials. Clin Oral Investig. 2012;16(4):1105\u201310.","journal-title":"Clin Oral Investig"},{"issue":"1","key":"4809_CR34","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1111\/jerd.12864","volume":"34","author":"JH Phark","year":"2022","unstructured":"Phark JH, Duarte S Jr. Microstructural considerations for novel lithium disilicate glass ceramics: a review. J Esthetic Restor Dentistry: Official Publication Am Acad Esthetic Dentistry [et al]. 2022;34(1):92\u2013103.","journal-title":"J Esthetic Restor Dentistry: Official Publication Am Acad Esthetic Dentistry [et al]"},{"issue":"12","key":"4809_CR35","doi-asserted-by":"publisher","first-page":"1235","DOI":"10.1177\/0022034514553627","volume":"93","author":"I Denry","year":"2014","unstructured":"Denry I, Kelly JR. Emerging ceramic-based materials for dentistry. J Dent Res. 2014;93(12):1235\u201342.","journal-title":"J Dent Res"},{"issue":"2\u20133","key":"4809_CR36","doi-asserted-by":"publisher","first-page":"1571","DOI":"10.1016\/j.jeurceramsoc.2006.04.103","volume":"27","author":"E Apel","year":"2007","unstructured":"Apel E, van\u2019t Hoen C, Rheinberger V, H\u00f6land W. Influence of ZrO2 on the crystallization and properties of lithium disilicate glass-ceramics derived from a multi-component system. J Eur Ceram. 2007;27(2\u20133):1571\u20137.","journal-title":"J Eur Ceram"},{"issue":"3","key":"4809_CR37","doi-asserted-by":"publisher","first-page":"1590","DOI":"10.1016\/j.matdes.2010.09.008","volume":"32","author":"H Yang","year":"2011","unstructured":"Yang H, Wu S, Hu J, Wang Z, Wang R, He H. Influence of nano-ZrO2 additive on the bending strength and fracture toughness of fluoro-silicic mica glass\u2013ceramics. Mater Des. 2011;32(3):1590\u20133.","journal-title":"Mater Des"},{"issue":"6","key":"4809_CR38","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1111\/jerd.12570","volume":"32","author":"AT Kasem","year":"2020","unstructured":"Kasem AT, Sakrana AA, Ellayeh M, \u00d6zcan M. Evaluation of zirconia and zirconia-reinforced glass ceramic systems fabricated for minimal invasive preparations using a novel standardization method. J Esthetic Restor Dentistry. 2020;32(6):560\u20138.","journal-title":"J Esthetic Restor Dentistry"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-024-04809-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-024-04809-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-024-04809-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,13]],"date-time":"2024-09-13T08:03:29Z","timestamp":1726214609000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-024-04809-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,13]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["4809"],"URL":"https:\/\/doi.org\/10.1186\/s12903-024-04809-2","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,13]]},"assertion":[{"value":"26 May 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 August 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 September 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The protocol was approved by the Institutional Ethical Committee, Faculty of Dentistry, Alexandria University (IRB NO 0564\u2009\u2212\u200912\/2022) and registered under registration number IORG0008839. All participants provided written informed consent to use their teeth for research purposes.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1078"}}