{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T14:19:52Z","timestamp":1780582792388,"version":"3.54.1"},"reference-count":69,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,10,4]],"date-time":"2024-10-04T00:00:00Z","timestamp":1728000000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,10,4]],"date-time":"2024-10-04T00:00:00Z","timestamp":1728000000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100012533","name":"Minia University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100012533","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>To assess marginal bone loss and soft tissue health around two-implant mandibular overdenture retained with milled versus selective laser-melted cobalt chromium (Co-Cr) bars.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Method<\/jats:title>\n                <jats:p>This research was set to be a parallel, triple-blinded, randomised controlled trial. Twenty completely edentulous patients received new conventional complete dentures according to conventional techniques. Two implants were placed at mandibular canine areas bilaterally, and patients were randomly allocated into two equal groups: the milled Co-Cr bar group and the selective laser melted (SLM) Co-Cr bar group. Marginal bone loss (MBL), modified plaque index (mPI), modified gingival index (mGI), and probing depth (PD) were evaluated at 0-month (baseline), 6-month, and 12-month follow-up visits. Repeated measures ANOVA test and Bonferroni\u2019s post-hoc test were used for parametric data as PD, while for non-parametric data as MBL, mGI, and mPI, Mann-Whitney U test and Friedman\u2019s test were used. A P-value\u2009\u2264\u20090.05 was set as the statistical level of significance. The study protocol was approved by the Faculty Research Ethics Committee at Minia University (636 4\/10\/2022). Registration for the clinical trial was made retrospectively on clinicaltrials.gov with ID NCT06401200 at 04\/30\/2024.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The follow-up period (one year) was completed without a dropout. Regarding MBL, no statistically significant difference was found between the two groups throughout the study. However, the milled group showed significantly increased MBL from 0- to 6-month follow up period. In both groups, mPI increased significantly from 0- to 6-months post-loading. On the other hand, no statistically significant difference between the two groups was found regarding mPI and mGI throughout the study follow-up periods. The PD was significantly lower in the milled compared to the SLM group at the 6- and 12-month follow up period.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Two-implant mandibular overdenture retained with milled or SLM Co-Cr bar can provide an acceptable treatment option for completely edentulous patients regarding marginal bone loss and soft tissue outcomes.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12903-024-04883-6","type":"journal-article","created":{"date-parts":[[2024,10,4]],"date-time":"2024-10-04T15:02:09Z","timestamp":1728054129000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Marginal bone loss and soft tissue health around two-implant mandibular overdenture retained with milled versus selective laser melted cobalt chromium bar: a randomized clinical trial"],"prefix":"10.1186","volume":"24","author":[{"given":"Iman Adel","family":"El-Asfahani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reem","family":"Abd El-Moatty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gehan Fekry","family":"Mohamed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hussein Abdelhady","family":"Hussein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,10,4]]},"reference":[{"key":"4883_CR1","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1111\/adj.12116","volume":"58","author":"J Dudley","year":"2013","unstructured":"Dudley J. Maxillary implant overdentures: current controversies. Aust Dent J. 2013;58:420\u20133.","journal-title":"Aust Dent J"},{"issue":"3","key":"4883_CR2","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1111\/joor.12241","volume":"42","author":"GC Boven","year":"2015","unstructured":"Boven GC, Raghoebar GM, Vissink A, Meijer HJ. Improving masticatory performance, bite force, nutritional state and patient\u2019s satisfaction with implant overdentures: a systematic review of the literature. J Rehabil. 2015;42(3):220\u201333. https:\/\/doi.org\/10.1111\/joor.12241.","journal-title":"J Rehabil"},{"issue":"2","key":"4883_CR3","doi-asserted-by":"publisher","first-page":"56","DOI":"10.23805\/JO.2021.13.02.2","volume":"13","author":"HN Asli","year":"2021","unstructured":"Asli HN, Hemmati YB, Ghaffari ME, Falahchai M. Satisfaction of patients with mandibular implant-supported overdentures using a generalized estimating equation model: a prospective study. J Osseointegration. 2021;13(2):56\u201362. https:\/\/doi.org\/10.23805\/JO.2021.13.02.2.","journal-title":"J Osseointegration"},{"issue":"4","key":"4883_CR4","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1111\/cid.12772","volume":"21","author":"MH Bakker","year":"2019","unstructured":"Bakker MH, Vissink A, Meijer HJ, Raghoebar GM, Visser A. Mandibular implant-supported overdentures in (frail) elderly: a prospective study with 20\u2010year follow\u2010up. Clin Implant Dent Relat Res. 2019;21(4):586\u201392. https:\/\/doi.org\/10.1111\/cid.12772.","journal-title":"Clin Implant Dent Relat Res"},{"key":"4883_CR5","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1038\/sj.bdj.2009.728","volume":"207","author":"J Thomason","year":"2009","unstructured":"Thomason J, Feine J, Exley C, et al. Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients - the York Consensus Statement. Br Dent J. 2009;207:185\u20136. https:\/\/doi.org\/10.1038\/sj.bdj.2009.728.","journal-title":"Br Dent J"},{"key":"4883_CR6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.9734\/BJMMR\/2016\/22015","volume":"12","author":"D Veleski","year":"2016","unstructured":"Veleski D, Shahpaska BP, Stevkovska DV. Application of different types of magnet retention systems in the prosthetic practice. Br J Med Med Res. 2016;12:1\u20137. https:\/\/doi.org\/10.9734\/BJMMR\/2016\/22015.","journal-title":"Br J Med Med Res"},{"key":"4883_CR7","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1007\/s11517-007-0173-2","volume":"45","author":"MC Cehreli","year":"2007","unstructured":"Cehreli MC, Akkocaoglu M, Comert A, et al. Bone strains around apically free versus grafted implants in the posterior maxilla of human cadavers. Med Bio Eng Comput. 2007;45:395\u2013402. https:\/\/doi.org\/10.1007\/s11517-007-0173-2.","journal-title":"Med Bio Eng Comput"},{"key":"4883_CR8","doi-asserted-by":"publisher","first-page":"640","DOI":"10.1034\/j.1600-0501.2001.120613.x","volume":"12","author":"SM Heckmann","year":"2008","unstructured":"Heckmann SM, Winter W, Meyer M, Weber HP, Wichmann MG. Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: a methodical study using five types of attachment. Clin Oral ImplantsRes. 2008;12:640\u20137. https:\/\/doi.org\/10.1034\/j.1600-0501.2001.120613.x.","journal-title":"Clin Oral ImplantsRes"},{"key":"4883_CR9","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1111\/j.1532-849X.2005.00005.x","volume":"14","author":"MP Gulizio","year":"2005","unstructured":"Gulizio MP, Agar JR, Kelly JR, Taylor TD. Effect of implant angulation upon retention of overdenture attachments. J Prosthodont. 2005;14:3\u201311. https:\/\/doi.org\/10.1111\/j.1532-849X.2005.00005.x.","journal-title":"J Prosthodont"},{"key":"4883_CR10","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1046\/j.1365-2842.1999.00369.x","volume":"26","author":"I Naert","year":"1999","unstructured":"Naert I, Gizani S, Vuylsteke M, Van Steenberghe D. A 5-year prospective randomized clinical trial on the influence of splinted and un splinted oral implants retaining a mandibular overdenture: prosthetic aspects and patient satisfaction. J Oral Rehabil. 1999;26:195\u2013202. https:\/\/doi.org\/10.1046\/j.1365-2842.1999.00369.x.","journal-title":"J Oral Rehabil"},{"issue":"19","key":"4883_CR11","doi-asserted-by":"publisher","first-page":"3248","DOI":"10.3390\/polym13193248","volume":"13","author":"B Mirchandani","year":"2021","unstructured":"Mirchandani B, Zhou T, Heboyan A, Yodmongkol S, Buranawat B. Biomechanical aspects of various attachments for implant overdentures: a review. Polymers. 2021;13(19):3248. https:\/\/doi.org\/10.3390\/polym13193248.","journal-title":"Polymers"},{"key":"4883_CR12","doi-asserted-by":"crossref","unstructured":"Wataha JC. Biocompatibility of dental casting alloys: a review. J Prosthet Dent, 83, 2, pp. 223\u2013 234, 2000. https:\/\/www.mdpi.com\/2073-4360\/13\/19\/3248","DOI":"10.1016\/S0022-3913(00)80016-5"},{"key":"4883_CR13","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1515\/afe-2016-0110","volume":"16","author":"D Myszka","year":"2016","unstructured":"Myszka D, Skrodzki M. Comparison of Dental Prostheses cast and sintered by SLM from Co-cr-mo-w Alloy. Arch Foundry Eng. 2016;16:201\u20137. ISSN (1897\u20133310).","journal-title":"Arch Foundry Eng"},{"key":"4883_CR14","doi-asserted-by":"publisher","unstructured":"Goo CL, Tan KB. Fabricating CAD\/CAM implant-retained mandibular bar overdentures: a clinical and technical overview. Case Rep Dentistry. 2017;2017. https:\/\/doi.org\/10.1155\/2017\/9373818","DOI":"10.1155\/2017\/9373818"},{"key":"4883_CR15","unstructured":"Anusavice KJ, Shen C, Rawls HR, editors. Phillips\u2019 science of dental materials. Elsevier Health Sciences; 27 Sep,2012."},{"key":"4883_CR16","doi-asserted-by":"crossref","unstructured":"Reclaru L, Ardelean LC. Current Alternatives for Processing CoCr Dental Alloys Lucien; Elsevier Inc.: Cambridge, MA, USA, 2018; Volume 1\u20133, ISBN 9780128051443.","DOI":"10.1016\/B978-0-12-801238-3.11100-6"},{"key":"4883_CR17","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/s41205-021-00098-5","volume":"7","author":"AE Alexander","year":"2021","unstructured":"Alexander AE, Wake N, Chepelev L, et al. A guideline for 3D printing terminology in biomedical research utilizing ISO\/ASTM standards. 3D Print Med. 2021;7:8. https:\/\/doi.org\/10.1186\/s41205-021-00098-5.","journal-title":"3D Print Med"},{"issue":"16","key":"4883_CR18","doi-asserted-by":"publisher","first-page":"3524","DOI":"10.3390\/ma13163524","volume":"13","author":"B Konieczny","year":"2020","unstructured":"Konieczny B, Szczesio-Wlodarczyk A, Sokolowski J, Bociong K. Challenges of Co\u2013Cr alloy additive manufacturing methods in dentistry\u2014the current state of knowledge (systematic review). Materials. 2020;13(16):3524. https:\/\/doi.org\/10.3390\/ma13163524.","journal-title":"Materials"},{"key":"4883_CR19","doi-asserted-by":"publisher","unstructured":"Kassapidou M, Hjalmarsson L, Johansson CB et al. Cobalt-chromium alloys fabricated with four different techniques: Ion release, toxicity of released elements and surface roughness. Dent Mater, 36, 11, pp. e352\u2013 e363, 2020. https:\/\/doi.org\/10.1016\/j.dental.2020.08.012","DOI":"10.1016\/j.dental.2020.08.012"},{"issue":"1","key":"4883_CR20","doi-asserted-by":"publisher","first-page":"1962514","DOI":"10.1155\/2018\/1962514","volume":"2018","author":"HN Mai","year":"2018","unstructured":"Mai HN, Kwon TY, Hong MH, Lee DH. Comparative study of the fit accuracy of full-Arch Bar frameworks fabricated with different presintered cobalt\u2010chromium alloys. Biomed Res Int. 2018;2018(1):1962514. https:\/\/doi.org\/10.1155\/2018\/1962514.","journal-title":"Biomed Res Int"},{"issue":"1","key":"4883_CR21","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.prosdent.2018.10.034","volume":"122","author":"S Ta\u015f\u0131n","year":"2019","unstructured":"Ta\u015f\u0131n S, Turp I, Bozda\u011f E, S\u00fcnb\u00fclo\u011flu E, \u00dc\u015f\u00fcmez A. Evaluation of strain distribution on an edentulous mandible generated by cobalt-chromium metal alloy fixed complete dentures fabricated with different techniques: an in vitro study. J Prosthet Dent. 2019;122(1):47\u201353. https:\/\/doi.org\/10.1016\/j.prosdent.2018.10.034.","journal-title":"J Prosthet Dent"},{"key":"4883_CR22","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1007\/s40496-017-0152-0","volume":"4","author":"M Revilla-Le\u00f3n","year":"2017","unstructured":"Revilla-Le\u00f3n M, \u00d6zcan M. Additive Manufacturing technologies used for 3D Metal Printing in Dentistry. Curr Oral Health Rep. 2017;4:201\u20138. https:\/\/doi.org\/10.1007\/s40496-017-0152-0.","journal-title":"Curr Oral Health Rep"},{"issue":"6","key":"4883_CR23","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1016\/j.prosdent.2016.03.024","volume":"116","author":"J-K Park","year":"2016","unstructured":"Park J-K, Kim H-Y, Kim W-C, Kim J-H. Evaluation of the fit of metal ceramic restorations fabricated with a presintered soft alloy. J Prosthet Dent. 2016;116(6):909\u201315. https:\/\/doi.org\/10.1016\/j.prosdent.2016.03.024.","journal-title":"J Prosthet Dent"},{"issue":"3","key":"4883_CR24","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.prosdent.2016.03.013","volume":"116","author":"H Kocaagao.glu","year":"2016","unstructured":"Kocaagao.glu H, \u02d9I H, K\u0131l\u0131nc\u00b8 H, Albayrak, Kara M. In vitro evaluation of marginal, axial, and occlusal discrepancies in metal ceramic restorations produced with new technologies. J Prosthet Dent. 2016;116(3):368\u201374. https:\/\/doi.org\/10.1016\/j.prosdent.2016.03.013.","journal-title":"J Prosthet Dent"},{"key":"4883_CR25","doi-asserted-by":"publisher","first-page":"200","DOI":"10.4103\/1735-3327.284726","volume":"17","author":"K Gholamrezaei","year":"2020","unstructured":"Gholamrezaei K, Vafaee F, Afkari BF, Firouz F, Seif M. Fit of cobalt-chromium copings fabricated by the selective laser melting technology and casting method: a comparative evaluation using a profilometer. Dent Res J. 2020;17:200\u20137. http:\/\/www.ncbi.nlm.nih.gov\/pmc\/journals\/1480.","journal-title":"Dent Res J"},{"issue":"6","key":"4883_CR26","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1111\/cid.12685","volume":"20","author":"J Abduo","year":"2018","unstructured":"Abduo J, Curtis M, Budhwar V, Palamara J. Influence of novel implant selective laser melting framework design on mechanical durability of acrylic veneer. Clin Implant Dent Relat Res. 2018;20(6):969\u201375. https:\/\/doi.org\/10.1111\/cid.12685.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"2","key":"4883_CR27","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1111\/cid.12970","volume":"23","author":"P Coli","year":"2021","unstructured":"Coli P, Jemt T. On marginal bone level changes around dental implants. Clin Implant Dent Relat Res. 2021;23(2):159\u201369. https:\/\/doi.org\/10.1111\/cid.12970.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"Suppl 20","key":"4883_CR28","doi-asserted-by":"publisher","first-page":"S278","DOI":"10.1111\/jcpe.12956","volume":"45","author":"S .Renvert","year":"2018","unstructured":".Renvert S, Persson GR, Pirih FQ, Camargo PM. Peri-implant health, peri-implant mucositis, and peri-implantitis: case definitions and diagnostic considerations. J Clin Periodontol. 2018;45(Suppl 20):S278\u201385. https:\/\/doi.org\/10.1111\/jcpe.12956.","journal-title":"J Clin Periodontol"},{"issue":"2","key":"4883_CR29","doi-asserted-by":"publisher","first-page":"1695","DOI":"10.21608\/edj.2022.119259.1968","volume":"68","author":"A Safaa","year":"2022","unstructured":"Safaa A, Mahanna F, Hegazy S. Comparison of peri-implant soft tissue changes and Retention of Zirconium Oxide Bar versus Metallic Bar retaining Mandibular Poly-Ether-Ether-Ketone (PEEK) overdenture. Egypt Dent J. 2022;68(2):1695\u2013705. https:\/\/doi.org\/10.21608\/edj.2022.119259.1968.","journal-title":"Egypt Dent J"},{"issue":"12","key":"4883_CR30","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.1111\/clr.13668","volume":"31","author":"M Srinivasan","year":"2020","unstructured":"Srinivasan M, Schimmel M, Buser R, Maniewicz S, Herrmann FR, M\u00fcller F. Mandibular two-implant overdentures with CAD\u2010CAM milled bars with distal extensions or retentive anchors: a randomized controlled trial. Clin Oral Implants Res. 2020;31(12):1207\u201322. https:\/\/doi.org\/10.1111\/clr.13668.","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"4883_CR31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40729-022-00439-x","volume":"8","author":"M Betth\u00e4user","year":"2022","unstructured":"Betth\u00e4user M, Schilter R, Enkling N, Suter VG, Abou-Ayash S, Schimmel M. Clinical outcomes of different implant types in mandibular bar-retained overdentures: a retrospective analysis with up to 20 years\u2019 follow-up. Int J Implant Dentistry. 2022;8(1):1\u20139. https:\/\/doi.org\/10.1186\/s40729-022-00439-x.","journal-title":"Int J Implant Dentistry"},{"issue":"4","key":"4883_CR32","doi-asserted-by":"publisher","first-page":"122","DOI":"10.21608\/asdj.2022.110989.1098","volume":"24","author":"NM Abdelkader","year":"2021","unstructured":"Abdelkader NM, Talaat IA, Nawar NH, Tarek H. The effect of two different bar materials constructed with CAD\/CAM technology on implant retained mandibular overdentures: radiographic evaluation. Ain Shams Dent J. 2021;24(4):122\u20139. https:\/\/doi.org\/10.21608\/asdj.2022.110989.1098.","journal-title":"Ain Shams Dent J"},{"issue":"4","key":"4883_CR33","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1111\/j.1600-0501.2011.02169.x","volume":"23","author":"G Krennmair","year":"2012","unstructured":"Krennmair G, S\u00fct\u00f6 D, Seemann R, Piehslinger E. Removable four implant-supported mandibular overdentures rigidly retained with telescopic crowns or milled bars: a 3\u2010year prospective study. Clin Oral Implants Res. 2012;23(4):481\u20138. https:\/\/doi.org\/10.1111\/j.1600-0501.2011.02169.x.","journal-title":"Clin Oral Implants Res"},{"issue":"2","key":"4883_CR34","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/S0022-3913(10)60107-2","volume":"104","author":"S Ahuja","year":"2010","unstructured":"Ahuja S, Cagna DR. Defining available restorative space for implant overdentures. J Prosthet Dent. 2010;104(2):133\u20136. https:\/\/doi.org\/10.1016\/S0022-3913(10)60107-2.","journal-title":"J Prosthet Dent"},{"key":"4883_CR35","doi-asserted-by":"publisher","first-page":"2309","DOI":"10.1007\/s00784-017-2331-8","volume":"22","author":"L Eberhard","year":"2018","unstructured":"Eberhard L, Oh K, Eiffler C, Rammelsberg P, Kappel S, Schindler HJ, Giannakopoulos NN. Adaptation to new complete dentures\u2014is the neuromuscular system outcome-oriented or effort-oriented. Clin Oral Invest. 2018;22:2309\u201317. https:\/\/doi.org\/10.1007\/s00784-017-2331-8.","journal-title":"Clin Oral Invest"},{"key":"4883_CR36","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1111\/jopr.12406","volume":"26","author":"G Sannino","year":"2017","unstructured":"Sannino G, Bollero P, Barlattani A, Gherlone E. A retrospective 2-Year clinical study of Immediate Prosthetic Rehabilitation of Edentulous Jaws with four implants and prefabricated bars. J Prosthodont. 2017;26:387\u201394. https:\/\/doi.org\/10.1111\/jopr.12406.","journal-title":"J Prosthodont"},{"key":"4883_CR37","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1111\/j.1600-0501.2011.02395.x","volume":"24","author":"MA Elsyad","year":"2013","unstructured":"Elsyad MA, El-Waseef FA, Al\u2010Mahdy YF, Fouad MM. A comparison of mandibular denture base deformation with different impression techniques for implant overdentures. Clin Oral Implants Res. 2013;24:127\u201333. https:\/\/doi.org\/10.1111\/j.1600-0501.2011.02395.x.","journal-title":"Clin Oral Implants Res"},{"key":"4883_CR38","doi-asserted-by":"publisher","first-page":"e188","DOI":"10.1111\/j.1708-8208.2011.00425.x","volume":"14","author":"C Ercoli","year":"2012","unstructured":"Ercoli C, Geminiani A, Feng C, Lee H. The influence of verification jig on framework fit for non-segmented fixed implant\u2009\u2013\u2009supported complete denture. Clin Implant Dent Relat Res. 2012;14:e188\u201395. https:\/\/doi.org\/10.1111\/j.1708-8208.2011.00425.x. no. s1.","journal-title":"Clin Implant Dent Relat Res"},{"key":"4883_CR39","doi-asserted-by":"publisher","unstructured":"Mahanna FF, Elsyad MA, Mourad SI, Abozaed HW. Satisfaction and oral health-related quality of life of different attachments used for Implant-retained overdentures in subjects with resorbed mandibles: a crossover trial. Int J Oral Maxillofacial Implants. 2020;35(2). https:\/\/doi.org\/10.11607\/jomi.7869.","DOI":"10.11607\/jomi.7869"},{"key":"4883_CR40","doi-asserted-by":"crossref","unstructured":"Tabata LF, Assun\u00e7\u00e3o WG, Bar\u00e3o VAR, Alves Gomes E, Aparecida Delben J, De Capello EA, Rocha EP. Comparison of single-standing or connected implants on stress distribution in bone of mandibular overdentures: A two-dimensional finite element analysis. J. Craniofac. Surg. 2010, 21, 696\u2013702. https:\/\/doi.org\/10.1097\/SCS.0b013e3181d7f202.","DOI":"10.1097\/SCS.0b013e3181d7f202"},{"key":"4883_CR41","doi-asserted-by":"crossref","unstructured":"Satheesh Kumar P, Satheesh KKS, John J, Patil G, Patel R. Force Transfer and Stress Distribution in an Implant-Supported Overdenture Retained with a Hader Bar Attachment: A Finite Element Analysis. ISRN Dent. 2013, 2013, 369147.","DOI":"10.1155\/2013\/369147"},{"key":"4883_CR42","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1186\/s12903-024-03915-5","volume":"24","author":"N Omeish","year":"2024","unstructured":"Omeish N, Bessou L, Carra MC, et al. Effect of bar designs on peri implant tissues health in implant-supported removable prostheses: a systematic review. BMC Oral Health. 2024;24:138. https:\/\/doi.org\/10.1186\/s12903-024-03915-5.","journal-title":"BMC Oral Health"},{"key":"4883_CR43","unstructured":"Abduo J, Bennani V, Waddell N, Lyons K, Swain M. Assessing the fit of implant fixed prostheses: a critical review. Int J Oral Maxillofacial Implants 2010, 25, 3, pp. 506\u201315. ISSN 0882\u20132786."},{"key":"4883_CR44","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1111\/cid.12436","volume":"19","author":"MA ELsyad","year":"2017","unstructured":"ELsyad MA, Hammouda NI. Expansion of mandibular knife-edge ridge and simultaneous implant placement to retain overdentures: one-year clinical and radiographic results of a prospective study. Clin Implant Dent Relat Res. 2017;19:167\u201379. https:\/\/doi.org\/10.1111\/cid.12436.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"11","key":"4883_CR45","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1111\/clr.13521","volume":"30","author":"JH Park","year":"2019","unstructured":"Park JH, Shin SW, Lee JY. Bar versus ball attachments for maxillary four-implant retained overdentures: a randomized controlled trial. Clin Oral Implants Res. 2019;30(11):1076\u201384. https:\/\/doi.org\/10.1111\/clr.13521.","journal-title":"Clin Oral Implants Res"},{"key":"4883_CR46","doi-asserted-by":"crossref","unstructured":"Kim DH, Park JB, Lee MS, Kwon YH, Herr Y. Interrelationship between periodontal parameters for the evaluation of clinically stable dental implants. J Korean Acad Periodontology. 1998.","DOI":"10.5051\/jkape.1998.28.1.1"},{"issue":"7","key":"4883_CR47","first-page":"0882","volume":"19","author":"GE Salvi","year":"2004","unstructured":"Salvi GE, Lang NP. Diagnostic parameters for monitoring peri-implant conditions. Int J Oral Maxillofacial Implants. 2004;19(7):0882\u20132786.","journal-title":"Int J Oral Maxillofacial Implants"},{"key":"4883_CR48","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1111\/joor.12368","volume":"43","author":"MA Elsyad","year":"2016","unstructured":"Elsyad MA, Mahanna FF, Elshahat MA, Elshoukouki AH. Locators versus magnetic attachment effect on peri-implant tissue health of immediate loaded two implants retaining a mandibular overdenture: a 1-year randomised trial. J Oral Rehabil. 2016;43:297\u2013305. https:\/\/doi.org\/10.1111\/joor.12368.","journal-title":"J Oral Rehabil"},{"issue":"4","key":"4883_CR49","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1016\/j.prosdent.2016.03.015","volume":"116","author":"A Pozzi","year":"2016","unstructured":"Pozzi A, Tallarico M, Moy PK. Four-implant overdenture fully supported by a CAD-CAM titanium bar: a single-cohort prospective 1-year preliminary study. J Prosthet Dent. 2016;116(4):516\u201323. https:\/\/doi.org\/10.1016\/j.prosdent.2016.03.015.","journal-title":"J Prosthet Dent"},{"issue":"7","key":"4883_CR50","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1111\/joor.12784","volume":"46","author":"M Toia","year":"2019","unstructured":"Toia M, Wennerberg A, Torrisi P, Farina V, Corr\u00e0 E, Cecchinato D. Patient satisfaction and clinical outcomes in implant-supported overdentures retained by milled bars: two-year follow-up. J Oral Rehabil. 2019;46(7):624\u201333. https:\/\/doi.org\/10.1111\/joor.12784.","journal-title":"J Oral Rehabil"},{"key":"4883_CR51","doi-asserted-by":"publisher","first-page":"e20230054","DOI":"10.3390\/dj6040071","volume":"31","author":"AP Chappuis-Chocano","year":"2023","unstructured":"Chappuis-Chocano AP, Venante HS, Costa RM, Pordeus MD, Marcillo-Toala OO, Santiago Junior JF, Porto VC. A systematic review and meta-analysis of the clinical performance of implant-supported overdentures retained by CAD-CAM bars. J Appl Oral Sci. 2023;31:e20230054. https:\/\/doi.org\/10.3390\/dj6040071.","journal-title":"J Appl Oral Sci"},{"key":"4883_CR52","unstructured":"Mallya S, Lam E. White and Pharoah\u2019s oral radiology: principles and interpretation. Elsevier Health Sciences; 2018 Sep 12."},{"issue":"2","key":"4883_CR53","doi-asserted-by":"publisher","first-page":"e657","DOI":"10.1111\/jopr.12676","volume":"28","author":"EA Abdel-Khalek","year":"2019","unstructured":"Abdel-Khalek EA. Fabrication of a simple acrylic template to standardize periapical radiographs for implants retaining mandibular bar overdentures. J Prosthodont. 2019;28(2):e657\u201360. https:\/\/doi.org\/10.1111\/jopr.12676.","journal-title":"J Prosthodont"},{"key":"4883_CR54","first-page":"19","volume":"8","author":"J Hartshorne","year":"2018","unstructured":"Hartshorne J. Essential guidelines for using cone beam computed tomography (CBCT) in implant dentistry. Part 2: clinical considerations. Int Dentistry Afr Ed. 2018;8:19.","journal-title":"Int Dentistry Afr Ed"},{"issue":"62B","key":"4883_CR55","doi-asserted-by":"publisher","first-page":"201","DOI":"10.9734\/jpri\/2021\/v33i62B35187","volume":"33","author":"S Chandak","year":"2021","unstructured":"Chandak S, Lohe V, Sune R, Mohod S, Meshram M. Role of imaging in Dental Implantology: a review. J Pharm Res Int. 2021;33(62B):201\u20136. https:\/\/doi.org\/10.9734\/jpri\/2021\/v33i62B35187.","journal-title":"J Pharm Res Int"},{"key":"4883_CR56","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1186\/s12903-021-01486-3","volume":"21","author":"W Liu","year":"2021","unstructured":"Liu W, Cai H, Zhang J, et al. Effects of immediate and delayed loading protocols on marginal bone loss around implants in unsplinted mandibular implant-retained overdentures: a systematic review and meta-analysis. BMC Oral Health. 2021;21:122. https:\/\/doi.org\/10.1186\/s12903-021-01486-3.","journal-title":"BMC Oral Health"},{"key":"4883_CR57","doi-asserted-by":"publisher","first-page":"195","DOI":"10.2147\/CCIDE.S208076","volume":"11","author":"J Zimmermann","year":"2019","unstructured":"Zimmermann J, Sommer M, Grize L, Stubinger S. Marginal bone loss 1 year after implantation: a systematic review for fixed and removable restorations. Clin Cosmet Invest Dentistry. 2019;11:195\u2013218. https:\/\/doi.org\/10.2147\/CCIDE.S208076.","journal-title":"Clin Cosmet Invest Dentistry"},{"issue":"5","key":"4883_CR58","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1111\/cid.13122","volume":"24","author":"P Galindo-Moreno","year":"2022","unstructured":"Galindo-Moreno P, Catena A, P\u00e9rez\u2010Say\u00e1ns M, Fern\u00e1ndez\u2010Barbero JE, O\u2019Valle F, Padial\u2010Molina M. Early marginal bone loss around dental implants to define success in implant dentistry: a retrospective study. Clin Implant Dent Relat Res. 2022;24(5):630\u201342. https:\/\/doi.org\/10.1111\/cid.13122.","journal-title":"Clin Implant Dent Relat Res"},{"key":"4883_CR59","doi-asserted-by":"publisher","unstructured":"Montanari M, Tallarico M, Vaccaro G, Ferrari E, Scrascia R, Ortensi L, Cicciu M, Meloni SM, Lumbau AI, Avrampou M, Martinolli M. Two years after loading performance of implant-supported overdenture with metal bar and low-profile attachments: A prospective case series multicenter clinical study. International Journal of Dentistry. 2020; 2020:1\u20138. https:\/\/doi.org\/10.1155\/2020\/8830722","DOI":"10.1155\/2020\/8830722"},{"issue":"4","key":"4883_CR60","doi-asserted-by":"publisher","first-page":"149","DOI":"10.21608\/mjd.2022.156078.1074","volume":"9","author":"NH Rashed","year":"2022","unstructured":"Rashed NH, El Shaheed NH, Ahmed WM, Hegazy SA. Soft metal versus laser Melting Metal Framework used for Mandibular all on four Implant supported fixed complete denture: a pilot study. Mansoura J Dentistry. 2022;9(4):149\u201355. https:\/\/doi.org\/10.21608\/mjd.2022.156078.1074.","journal-title":"Mansoura J Dentistry"},{"key":"4883_CR61","doi-asserted-by":"publisher","unstructured":"Zou D, Wu Y, Huang W, Zhang Z, Zhang Z. A 5-to 8-year retrospective study comparing the clinical results of implant-supported telescopic crown versus bar overdentures in patients with edentulous maxillae. Int J Oral Maxillofacial Implants. 2013;28(5). https:\/\/doi.org\/10.11607\/jomi.3100.","DOI":"10.11607\/jomi.3100"},{"key":"4883_CR62","doi-asserted-by":"crossref","unstructured":"Zhou H, Jiao Y, Ma CF, Wang C, Zhao SJ, Tian M, Tay FR, Chen JH. Clinical outcomes of implant-retained mandibular overdentures using the bar and magnetic attachment systems: an up to 5-year retrospective study. Annals Translational Med. 2020;8(21). https:\/\/doi.org\/10.21037%2Fatm-20-2531.","DOI":"10.21037\/atm-20-2531"},{"key":"4883_CR63","doi-asserted-by":"publisher","unstructured":"ELsyad MA, Denewar BA, Elsaih EA. Clinical and Radiographic Evaluation of Bar, Telescopic, and Locator attachments for Implant-stabilized overdentures in patients with Mandibular Atrophied ridges: a Randomized Controlled Clinical Trial. Int J Oral Maxillofacial Implants. 2018;33(5). https:\/\/doi.org\/10.11607\/jomi.6363.","DOI":"10.11607\/jomi.6363"},{"issue":"4","key":"4883_CR64","doi-asserted-by":"publisher","first-page":"313","DOI":"10.4047\/jap.2016.8.4.313","volume":"8","author":"YH Seo","year":"2016","unstructured":"Seo YH, Bae EB, Kim JW, Lee SH, Yun MJ, Jeong CM, Jeon YC, Huh JB. Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment. J Adv Prosthodont. 2016;8(4):313. https:\/\/doi.org\/10.4047%2Fjap.2016.8.4.313.","journal-title":"J Adv Prosthodont"},{"issue":"11","key":"4883_CR65","doi-asserted-by":"publisher","first-page":"1147","DOI":"10.1111\/clr.13997","volume":"33","author":"W Slot","year":"2022","unstructured":"Slot W, Raghoebar GM, Cune MS, Vissink A, Meijer HJ. Maxillary bar overdentures on four or six posterior implants: 10-year results from a randomized clinical trial. Clin Oral Implants Res. 2022;33(11):1147\u201356. https:\/\/doi.org\/10.1111\/clr.13997.","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"4883_CR66","doi-asserted-by":"publisher","first-page":"1","DOI":"10.5051\/jkape.1998.28.1.1","volume":"28","author":"DH Kim","year":"1998","unstructured":"Kim DH, Park JB, Lee MS, Kwon YH, Herr Y. Interrelationship between periodontal parameters for the evaluation of clinically stable dental implants. J Korean Acad Periodontology. 1998;28(1):1\u20136.","journal-title":"J Korean Acad Periodontology"},{"issue":"18","key":"4883_CR67","doi-asserted-by":"publisher","first-page":"8328","DOI":"10.3390\/app11188328","volume":"11","author":"AS Alqahtani","year":"2021","unstructured":"Alqahtani AS, AlFadda AM, Eldesouky M, Alnuwaiser MK, Al-Saleh S, Alresayes S, Alshahrani A, Vohra F, Abduljabbar T. Comparison of marginal integrity and surface roughness of selective laser melting, CAD-CAM and digital light processing manufactured co-cr alloy copings. Appl Sci. 2021;11(18):8328. https:\/\/doi.org\/10.3390\/app11188328.","journal-title":"Appl Sci"},{"issue":"3","key":"4883_CR68","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1016\/j.prosdent.2023.11.034","volume":"131","author":"IM Heiba","year":"2024","unstructured":"Heiba IM, Mohamed SL, Sabet ME. Accuracy and surface roughness of Co-cr partial denture frameworks with different digital fabrication methods. J Prosthet Dent. 2024;131(3):520\u2013e1. https:\/\/doi.org\/10.1016\/j.prosdent.2023.11.034.","journal-title":"J Prosthet Dent"},{"key":"4883_CR69","doi-asserted-by":"publisher","first-page":"1776","DOI":"10.3390\/ma4101776","volume":"4","author":"M Koike","year":"2011","unstructured":"Koike M, Greer P, Owen K, Lilly G, Murr LE, Gaytan SM, et al. Evaluation of titanium alloys fabricated using rapid prototyping technologies \u2014electron beam melting and laser beam melting. Materials. 2011;4:1776\u201392. https:\/\/doi.org\/10.3390\/ma4101776.","journal-title":"Materials"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-024-04883-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-024-04883-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-024-04883-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,4]],"date-time":"2024-10-04T15:02:47Z","timestamp":1728054167000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-024-04883-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,4]]},"references-count":69,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["4883"],"URL":"https:\/\/doi.org\/10.1186\/s12903-024-04883-6","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,4]]},"assertion":[{"value":"2 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 September 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 October 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Approved from the Research Ethics Committee Faculty of Dentistry Minia University Research Ethics Committee (no 636 4\/10\/2022). Registration of the clinical trial was made on clinicaltrials.gov ID (NCT06401200) at 04\/30\/2024.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from participants.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Not applicable. As there are no identifiable images of the participants. <b>Competing interests<\/b> The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1180"}}