{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T00:00:51Z","timestamp":1791158451097,"version":"4.1.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,11,22]],"date-time":"2024-11-22T00:00:00Z","timestamp":1732233600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,11,22]],"date-time":"2024-11-22T00:00:00Z","timestamp":1732233600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009827","name":"Alexandria University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100009827","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Designing the occlusal surface of a prosthesis to ensure optimal eccentric occlusion is challenging without precisely replicating the patient\u2019s mandibular movements. During the CAD-CAM prosthesis delivery process, clinicians often need to make adjustments to the prosthesis to avoid occlusal interferences that may occur during lateral excursions. Recently, there have been developments in the field of mandibular motion tracking using optical devices. These approaches seek to incorporate an individual\u2019s functional movement into the research field of occlusal morphology.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aim<\/jats:title>\n                    <jats:p>This study aimed to assess the accuracy of digitally replicating mandibular movements to identify and correct occlusal interferences in monolithic CAD-CAM zirconia crowns.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>An intraoral scanner (IOS) was used to capture complete arch maxillary and mandibular teeth and record buccal and lateral interocclusal records of maxillary first premolar abutment teeth of thirteen participants. For each patient, two monolithic zirconia crowns were fabricated following the standard digital workflow. The crowns were categorized based on the virtual method used for adjusting occlusal interferences into two groups: Group I, where occlusal interferences in CAD-CAM zirconia crowns were adjusted using buccal interocclusal records, and Group II, where adjustments were made using both buccal and lateral interocclusal records. After crown fabrication following the manufacturer\u2019s instructions, occlusion was analyzed using an electronic pressure analyzer. The mean, standard deviation and median values of the recorded data were measured. Paired t test and Wilcoxon Sign Rank test were executed for analyzing differences between groups (p value\u2009\u2264\u20090.05).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Group I recorded higher maximum pressure at lateral mandibular movement with mean\u2009\u00b1\u2009standard deviation value of 26.00\u2009\u00b1\u20094.95% than Group II with 20.62\u2009\u00b1\u20093.38%. Regarding pressure recorded at maximum intercuspation (MI) Group I showed higher results; 8.08\u2009\u00b1\u20091.50% compared to Group II with 7.23\u2009\u00b1\u20091.59% mean\u2009\u00b1\u2009standard deviation value. The average value of crown volume for Group I was (160.36\u2009\u00b1\u200915.94) mm\n                      <jats:sup>3<\/jats:sup>\n                      , while for Group II was (157.63\u2009\u00b1\u200914.45) mm\n                      <jats:sup>3<\/jats:sup>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The digital functionally generated path technique allows for identifying occlusal interferences and modifying CAD-CAM zirconia crown designs.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-024-05202-9","type":"journal-article","created":{"date-parts":[[2024,11,22]],"date-time":"2024-11-22T05:24:22Z","timestamp":1732253062000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Reliability of the digital functionally generated path technique for assessing occlusal interferences and adjusting CAD-CAM zirconia crowns: an in vivo study"],"prefix":"10.1186","volume":"24","author":[{"given":"Sherine Anwar","family":"Saad","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yousreya Atteya","family":"Shalaby","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir Shoukry","family":"Azer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,11,22]]},"reference":[{"key":"5202_CR1","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1111\/jopr.13268","volume":"30","author":"AD Fiore","year":"2021","unstructured":"Fiore AD, Monaco C, Brunello G, Granata S, Stellini E, Yilmaz B. Automatic Digital Design of the Occlusal anatomy of monolithic Zirconia crowns compared to Dental technicians\u2019 Digital Waxing: a controlled clinical trial. J Prosthodont. 2021;30:104\u201310.","journal-title":"J Prosthodont"},{"key":"5202_CR2","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1111\/j.1365-2842.2007.01820.x","volume":"35","author":"JC T\u00fcrp","year":"2008","unstructured":"T\u00fcrp JC, Greene CS, Strub JR. Dental occlusion: a critical reflection on past, present and future concepts. J Oral Rehabil. 2008;35:446\u201353.","journal-title":"J Oral Rehabil"},{"key":"5202_CR3","doi-asserted-by":"publisher","first-page":"1745","DOI":"10.1007\/s00784-018-2606-8","volume":"23","author":"S Berrendero","year":"2019","unstructured":"Berrendero S, Salido MP, Ferreiroa A, Valverde A, Prad\u00edes G. Comparative study of all-ceramic crowns obtained from conventional and digital impressions: clinical findings. Clin Oral Investig. 2019;23:1745\u201351.","journal-title":"Clin Oral Investig"},{"key":"5202_CR4","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1111\/jerd.12527","volume":"32","author":"S Koulivand","year":"2020","unstructured":"Koulivand S, Ghodsi S, Siadat H, Alikhasi M. A clinical comparison of digital and conventional impression techniques regarding finish line locations and impression time. J Esthet Restor Dent. 2020;32:236\u201343.","journal-title":"J Esthet Restor Dent"},{"key":"5202_CR5","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1016\/j.jmbbm.2011.03.014","volume":"4","author":"T Sornsuwan","year":"2011","unstructured":"Sornsuwan T, Swain MV. Influence of occlusal geometry on ceramic crown fracture; role of cusp angle and fissure radius. J Mech Behav Biomed Mater. 2011;4:1057\u201366.","journal-title":"J Mech Behav Biomed Mater"},{"key":"5202_CR6","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1007\/s00784-016-1849-5","volume":"21","author":"S Kist","year":"2017","unstructured":"Kist S, Kollmuss M, Jung J, Schubert S, Hickel R, Huth KC. Comparison of ozone gas and sodium hypochlorite\/chlorhexidine two-visit disinfection protocols in treating apical periodontitis: a randomized controlled clinical trial. Clin Oral Investig. 2017;21:995\u20131005.","journal-title":"Clin Oral Investig"},{"key":"5202_CR7","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1111\/j.1600-0722.2005.00224.x","volume":"113","author":"A Mehl","year":"2005","unstructured":"Mehl A, Blanz V, Hickel R. Biogeneric tooth: a new mathematical representation for tooth morphology in lower first molars. Eur J Oral Sci. 2005;113:333\u201340.","journal-title":"Eur J Oral Sci"},{"key":"5202_CR8","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1016\/j.prosdent.2015.08.028","volume":"115","author":"T El Kerdani","year":"2016","unstructured":"El Kerdani T, Nimmo A. Integrating conventional and CAD\/CAM digital techniques for establishing canine protected articulation: a clinical report. J Prosthet Dent. 2016;115:515\u20139.","journal-title":"J Prosthet Dent"},{"key":"5202_CR9","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1016\/j.prosdent.2014.10.003","volume":"113","author":"A Zandinejad","year":"2015","unstructured":"Zandinejad A, Metz M, Stevens P, Lin WS, Morton D. Virtually designed and CAD\/CAM-fabricated lithium disilicate prostheses for an esthetic maxillary rehabilitation: a senior dental student clinical report. J Prosthet Dent. 2015;113:282\u20138.","journal-title":"J Prosthet Dent"},{"key":"5202_CR10","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/j.prosdent.2020.05.011","volume":"126","author":"M Valenti","year":"2021","unstructured":"Valenti M, Schmitz JH. A reverse digital workflow by using an interim restoration scan and patient-specific motion with an intraoral scanner. J Prosthet Dent. 2021;126:19\u201323.","journal-title":"J Prosthet Dent"},{"key":"5202_CR11","doi-asserted-by":"crossref","unstructured":"Carrilho Baltazar Vaz IM, Pimentel Coelho Lino Carracho JF. Marginal fit of zirconia copings fabricated after conventional impression making and digital scanning: An in vitro study. J Prosthet Dent. 2020;124:223.e1-223.e6.","DOI":"10.1016\/j.prosdent.2020.02.011"},{"key":"5202_CR12","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1016\/j.prosdent.2020.01.035","volume":"125","author":"M Tabesh","year":"2021","unstructured":"Tabesh M, Nejatidanesh F, Savabi G, Davoudi A, Savabi O, Mirmohammadi H. Marginal adaptation of zirconia complete-coverage fixed dental restorations made from digital scans or conventional impressions: a systematic review and meta-analysis. J Prosthet Dent. 2021;125:603\u201310.","journal-title":"J Prosthet Dent"},{"key":"5202_CR13","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/j.prosdent.2019.08.006","volume":"125","author":"CW Cheng","year":"2021","unstructured":"Cheng CW, Ye SY, Chien CH, Chen CJ, Papaspyridakos P, Ko CC. Randomized clinical trial of a conventional and a digital workflow for the fabrication of interim crowns: an evaluation of treatment efficiency, fit, and the effect of clinician experience. J Prosthet Dent. 2021;125:73\u201381.","journal-title":"J Prosthet Dent"},{"key":"5202_CR14","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1111\/jopr.12410","volume":"25","author":"B Gjelvold","year":"2016","unstructured":"Gjelvold B, Chrcanovic BR, Korduner EK, Collin-Bagewitz I, Kisch J. Intraoral digital impression technique compared to conventional impression technique. A randomized clinical trial. J Prosthodont. 2016;25:282\u20137.","journal-title":"J Prosthodont"},{"key":"5202_CR15","doi-asserted-by":"crossref","unstructured":"Bozhkova T. Capabilities of the T-Scan 10 Novus System in the diagnosis of occlusion. J Pharm Res Int. 2022;34:7\u201319.","DOI":"10.9734\/jpri\/2022\/v34i18A35774"},{"key":"5202_CR16","first-page":"130","volume":"29","author":"S Qadeer","year":"2021","unstructured":"Qadeer S, \u00d6zcan M, Edelhoff D, Vanpelt H. Accuracy, reliability and clinical implications of Static compared to quantifiable Occlusal indicators. Eur J Prosthodont Restor Dent. 2021;29:130\u201341.","journal-title":"Eur J Prosthodont Restor Dent"},{"key":"5202_CR17","doi-asserted-by":"publisher","first-page":"4663","DOI":"10.1007\/s00784-022-04542-6","volume":"26","author":"C Fraile","year":"2022","unstructured":"Fraile C, Ferreiroa A, Romeo Rubio M, Alonso R, Prad\u00edes Ramiro G. Clinical study comparing the accuracy of interocclusal records, digitally obtained by three different devices. Clin Oral Investig. 2022;26:4663\u20138.","journal-title":"Clin Oral Investig"},{"key":"5202_CR18","doi-asserted-by":"publisher","first-page":"1163874","DOI":"10.1155\/2021\/1163874","volume":"2021","author":"T Bozhkova","year":"2021","unstructured":"Bozhkova T, Musurlieva N, Slavchev D. Comparative study qualitative and quantitative techniques in the study of occlusion. Biomed Res Int. 2021;2021:1163874.","journal-title":"Biomed Res Int"},{"key":"5202_CR19","first-page":"1","volume":"2","author":"B Sutter","year":"2019","unstructured":"Sutter B. Digital occlusion analyzers: a product review of T-Scan 10 and OccluSense. Adv Dent Tech. 2019;2:1\u201331.","journal-title":"Adv Dent Tech"},{"key":"5202_CR20","doi-asserted-by":"publisher","first-page":"9140","DOI":"10.3390\/app10249140","volume":"10","author":"YC Lee","year":"2020","unstructured":"Lee YC, Lee C, Shim JS, Park JM, Shin Y, Kim JE, et al. Comparison between occlusal errors of single posterior crowns adjusted using patient specific motion or conventional methods. Appl Sci. 2020;10:9140.","journal-title":"Appl Sci"},{"key":"5202_CR21","unstructured":"Rosner B. Fundamentals of biostatistics. Nelson Education. 2015."},{"key":"5202_CR22","unstructured":"Anusavice KJ. Phillips\u2019 Science of Dental materials (Anusavice Phillip\u2019s Science of Dental materials). Volume 12. Elsevier Saunders; 2021."},{"key":"5202_CR23","unstructured":"Shillingburg HT. Fundamental of fixed prosthodontics 4th Edition. Quintessence publishing co, Inc; 2012."},{"key":"5202_CR24","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1111\/jopr.13170","volume":"29","author":"WM Ahmed","year":"2020","unstructured":"Ahmed WM, Troczynski T, Stojkova BJ, McCullagh AP, Wyatt CC, Carvalho RM. Dimensional changes of yttria-stabilized zirconia under different preparation designs and sintering protocols. J Prosthodont. 2020;29:699\u2013706.","journal-title":"J Prosthodont"},{"key":"5202_CR25","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1016\/j.prosdent.2015.12.004","volume":"115","author":"GK Koch","year":"2016","unstructured":"Koch GK, Gallucci GO, Lee SJ. Accuracy in the digital workflow: from data acquisition to the digitally milled cast. J Prosthet Dent. 2016;115:749\u201354.","journal-title":"J Prosthet Dent"},{"key":"5202_CR26","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1007\/s00784-021-04068-3","volume":"26","author":"IHG de Carvalho","year":"2022","unstructured":"de Carvalho IHG, da Silva NR, Vila-Nova TEL, de Fatima Dantas L, Ver\u00edssimo AH, de Melo RM, et al. Effect of finishing\/polishing techniques and aging on topography, C. Albicans adherence, and flexural strength of ultra-translucent zirconia: an in situ study. Clin Oral Investig. 2022;26:889\u2013900.","journal-title":"Clin Oral Investig"},{"key":"5202_CR27","doi-asserted-by":"publisher","first-page":"984","DOI":"10.1016\/j.jdent.2008.08.005","volume":"36","author":"T Watamoto","year":"2008","unstructured":"Watamoto T, Egusa H, Mizumori T, Yashiro K, Takada K, Yatani H. Restoration of occlusal and proximal contacts by a single molar crown improves the smoothness of the masticatory movement. J Dent. 2008;36:984\u201392.","journal-title":"J Dent"},{"key":"5202_CR28","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1016\/j.cad.2008.10.006","volume":"41","author":"JJ Fang","year":"2009","unstructured":"Fang JJ, Kuo TH. Tracked motion-based dental occlusion surface estimation for crown restoration. Comput Aided Des. 2009;41:315\u201323.","journal-title":"Comput Aided Des"},{"key":"5202_CR29","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1111\/jopr.13252","volume":"30","author":"Y Altarakemah","year":"2021","unstructured":"Altarakemah Y, Akbar J, Akthar S, Qudeimat MA, Omar R. Evaluation of a technique for reducing Chairside Occlusal Adjustment of crowns. J Prosthodont. 2021;30:183\u20138.","journal-title":"J Prosthodont"},{"key":"5202_CR30","first-page":"S78","volume":"92","author":"S Buduru","year":"2019","unstructured":"Buduru S, Mesaros A, Talmaceanu D, Baru O, Ghiurca R, Cosgarea R. Occlusion in the digital era: a report on 3 cases. Med Pharm Rep. 2019;92:S78\u201384.","journal-title":"Med Pharm Rep"},{"key":"5202_CR31","first-page":"10","volume":"6","author":"D Wan","year":"2023","unstructured":"Wan D, Fahd I. Comparison between digital and conventional occlusal indicators. EDJ. 2023;6:10\u20139.","journal-title":"EDJ"},{"key":"5202_CR32","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1016\/j.prosdent.2016.07.034","volume":"117","author":"JH Park","year":"2017","unstructured":"Park JH, Kim JE, Shim JS. Digital workflow for a dental prosthesis that considers lateral mandibular relation. J Prosthet Dent. 2017;117:340\u20134.","journal-title":"J Prosthet Dent"},{"key":"5202_CR33","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1016\/j.prosdent.2021.06.048","volume":"129","author":"L Li","year":"2023","unstructured":"Li L, Chen H, Li W, Wang Y, Sun Y. Design of wear facets of mandibular first molar crowns by using patient-specific motion with an intraoral scanner: a clinical study. J Prosthet Dent. 2023;129:710\u20137.","journal-title":"J Prosthet Dent"},{"key":"5202_CR34","doi-asserted-by":"crossref","unstructured":"Attia M, Wahsh M, Fahmy NZ, Aboelfadl A, Zohdy M. Accuracy of digital occlusal records versus conventional mechanical methods. Int J Health Sci. 2022;6:3820\u201339.","DOI":"10.53730\/ijhs.v6nS7.12602"},{"key":"5202_CR35","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1038\/s41598-017-00408-0","volume":"7","author":"PT Lin","year":"2017","unstructured":"Lin PT, Jiao Y, Zhao SJ, Wang F, Li L, Yu F, et al. Occlusion and disocclusion time changes in single unit crowns designed by functional generated path technique: a randomised clinical trial. Sci Rep. 2017;7:388.","journal-title":"Sci Rep"},{"key":"5202_CR36","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1111\/jopr.13286","volume":"30","author":"TH Farook","year":"2021","unstructured":"Farook TH, Barman A, Abdullah JY, Jamayet N, Bin. Optimization of prosthodontic computer-aided designed models: a virtual evaluation of mesh quality reduction using open source software. J Prosthodont. 2021;30:420\u20139.","journal-title":"J Prosthodont"},{"key":"5202_CR37","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/j.msec.2016.02.049","volume":"63","author":"GK Pereira","year":"2016","unstructured":"Pereira GK, Silvestri T, Camargo R, Rippe MP, Amaral M, Kleverlaan CJ, et al. Mechanical behavior of a Y-TZP ceramic for monolithic restorations: effect of grinding and low-temperature aging. Mater Sci Eng C Mater Biol Appl. 2016;63:70\u20137.","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"key":"5202_CR38","doi-asserted-by":"crossref","unstructured":"Jauregi M, Amezua X, Iturrate M, Solaberrieta E. Improving the precision of recordings acquired with digital occlusal analyzers: a dental technique. J Prosthet Dent. 2024;132:37\u201341.","DOI":"10.1016\/j.prosdent.2023.08.001"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-024-05202-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-024-05202-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-024-05202-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,22]],"date-time":"2024-11-22T06:04:03Z","timestamp":1732255443000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-024-05202-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,22]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["5202"],"URL":"https:\/\/doi.org\/10.1186\/s12903-024-05202-9","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,22]]},"assertion":[{"value":"10 February 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 November 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 November 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the Research Ethics Committee of the Faculty of Dentistry at Alexandria University in Egypt. Informed consent was obtained from all subjects involved in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1425"}}