{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T00:06:44Z","timestamp":1792800404236,"version":"4.5.0"},"reference-count":47,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,2,28]],"date-time":"2025-02-28T00:00:00Z","timestamp":1740700800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,2,28]],"date-time":"2025-02-28T00:00:00Z","timestamp":1740700800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Misr International University","id":[{"id":"https:\/\/ror.org\/030vg1t69","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Primary retention and progressive loss of retention of various attachment systems are critical elements in appropriate attachment selection; nevertheless, research on attachment retention reveals a broad spectrum of retention values for the same attachment system and between various systems. Accordingly, the aim of this study was to compare the retention of two different types of attachments (Ti Si snaps and locators) in two-implant-retained mandibular overdentures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A completely edentulous mandibular educational cast was scanned. An STL file including the implant beds and mucosal space was designed. Two implant analogs were incorporated into each model in the canine area bilaterally, and conventional overdentures were fabricated over two types of implant attachments, the Ti Si snap attachments and the locator attachments, with the use of Retention sil in both groups at the fitting surface of the overdenture. Each group contained five 3D-printed edentulous mandibular models. Retention was measured by using a universal testing machine after the models were subjected to cyclic loading. This measurement was carried out at the time of insertion, after 75,000 cycles (simulating 6 months of clinical use) and 150,000 cycles (simulating 12 months of clinical use). The means and standard deviations of the recorded readings were collected, tabulated, and statistically analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Student\u2019s t test revealed significant differences between the two groups. The Ti Si attachment group presented the highest retention rate at the time of insertion and after 6 months. However, there was no significant difference between the groups after 12 months. Both groups presented statistically significant changes in the mean retention value over time, as demonstrated by two-way ANOVA (time of insertion\u2009&gt;\u2009six months\u2009&gt;\u2009twelve months). Tukey\u2019s post hoc test revealed a nonsignificant difference between six months and twelve months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Within the limitations of this study, the following conclusions can be drawn:<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-025-05625-y","type":"journal-article","created":{"date-parts":[[2025,2,28]],"date-time":"2025-02-28T01:50:52Z","timestamp":1740707452000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Retention of Ti Si snap versus locator attachments with retention sil in two-implant retained mandibular overdentures: an in vitro study"],"prefix":"10.1186","volume":"25","author":[{"given":"Dina","family":"Mourad","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nesrin A.","family":"El-mahrouky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed A. Abd","family":"El-Dayem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasser M.","family":"Shawky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,2,28]]},"reference":[{"issue":"3","key":"5625_CR1","first-page":"344","volume":"58","author":"U Soboleva","year":"2022","unstructured":"Soboleva U, Rogovska I. Edentulous patient satisfaction with conventional complete dentures. Med (B Aires). 2022;58(3):344.","journal-title":"Med (B Aires)"},{"issue":"5","key":"5625_CR2","doi-asserted-by":"publisher","first-page":"1933","DOI":"10.3390\/ma15051933","volume":"15","author":"R Wakam","year":"2022","unstructured":"Wakam R, Benoit A, Mawussi KB, Gorin C. Evaluation of retention, wear, and maintenance of attachment systems for single- or two-implant-retained mandibular overdentures: a systematic review. Materials. 2022;15(5):1933.","journal-title":"Materials"},{"issue":"3","key":"5625_CR3","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1038\/sj.bdj.4800703a","volume":"189","author":"J McCord","year":"2000","unstructured":"McCord J, Grant A. Identification of complete denture problems: a summary. Br Dent J. 2000;189(3):128\u201334.","journal-title":"Br Dent J"},{"issue":"2","key":"5625_CR4","doi-asserted-by":"publisher","first-page":"244","DOI":"10.3889\/oamjms.2017.047","volume":"5","author":"MI El-Anwar","year":"2017","unstructured":"El-Anwar MI, El-Taftazany EA, Hamed HA, Abd ElHay MA. Influence of number of implants and attachment type on stress distribution in mandibular implant-retained overdentures: finite element analysis. Open Access Maced J Med Sci. 2017;5(2):244\u20139.","journal-title":"Open Access Maced J Med Sci"},{"issue":"1","key":"5625_CR5","doi-asserted-by":"publisher","first-page":"742","DOI":"10.1186\/s12913-022-08136-6","volume":"22","author":"M Nand","year":"2022","unstructured":"Nand M, Mohammadnezhad M. Challenges faced by edentulous patients (EDPs) during complete denture prostheses (CDP) service delivery in Fiji - a qualitative study. BMC Health Serv Res. 2022;22(1):742.","journal-title":"BMC Health Serv Res"},{"issue":"2","key":"5625_CR6","doi-asserted-by":"publisher","first-page":"1893","DOI":"10.21608\/edj.2018.78449","volume":"64","author":"H Khorshid","year":"2018","unstructured":"Khorshid H. A comparison between two different types of attachments in implant retained mandibular overdentures (a stress analysis study). Egypt Dent J. 2018;64(2):1893\u2013902.","journal-title":"Egypt Dent J"},{"issue":"10","key":"5625_CR7","doi-asserted-by":"publisher","first-page":"1221","DOI":"10.5005\/jp-journals-10024-2408","volume":"19","author":"SM Hakimaneh","year":"2018","unstructured":"Hakimaneh SM, Shidfar S, Teimoori H, Shayegh SS, Zavaree MA, Khodadad F, et al. Effects of excessive implant angulation on retention of two types of overdenture attachments during cyclic loading. J Contemp Dent Pract. 2018;19(10):1221\u20137.","journal-title":"J Contemp Dent Pract"},{"issue":"2","key":"5625_CR8","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1111\/jopr.13516","volume":"32","author":"MS Abdelaziz","year":"2023","unstructured":"Abdelaziz MS, Fawzy AM, Ghali RM, Nassar HI. Retention of different attachment systems for digitally designed mandibular implant overdenture. J Prosthodont. 2023;32(2):162\u20139.","journal-title":"J Prosthodont"},{"key":"5625_CR9","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1016\/j.mjafi.2015.02.005","volume":"71","author":"K Satyendra","year":"2015","unstructured":"Satyendra K, Kumar D, Legha VS, Arun Kumar KV. Specially designed tooth supported mandibular overdenture with enhanced retention. Med J Armed Forces India. 2015;71:546\u20138.","journal-title":"Med J Armed Forces India"},{"issue":"1","key":"5625_CR10","first-page":"2","volume":"3","author":"D Laurito","year":"2012","unstructured":"Laurito D, Lamazza L, Spink MJ, De Biase A. Tissue-supported dental implant prosthesis (overdenture): the search for the ideal protocol. A literature review. Ann Stomatol (Roma). 2012;3(1):2\u201310.","journal-title":"Ann Stomatol (Roma)"},{"issue":"5","key":"5625_CR11","doi-asserted-by":"publisher","first-page":"1079","DOI":"10.11607\/jomi.6023","volume":"33","author":"JW Choi","year":"2018","unstructured":"Choi JW, Yun BH, Jeong CM, Huh JB. Retentive properties of two stud attachments with polyetherketoneketone or nylon insert in mandibular implant overdentures. Int J Oral Maxillofac Implants. 2018;33(5):1079\u201388.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"2","key":"5625_CR12","doi-asserted-by":"publisher","first-page":"6","DOI":"10.21608\/asdj.2022.160486.1139","volume":"26","author":"A Badr","year":"2022","unstructured":"Badr A. Effect of using two different mini dental implant attachments on marginal bone height and prosthetic maintenance in implant retained mandibular overdenture. Ain Shams Dent J. 2022;26(2):6\u201314.","journal-title":"Ain Shams Dent J"},{"issue":"1","key":"5625_CR13","doi-asserted-by":"publisher","first-page":"15","DOI":"10.21608\/asdj.2023.200385.1172","volume":"29","author":"S Mohammed","year":"2023","unstructured":"Mohammed S. Effect of two different digitally constructed bar materials on the supporting structures of implant-retained mandibular overdenture (in vitro study). Ain Shams Dent J. 2023;29(1):15\u201322.","journal-title":"Ain Shams Dent J"},{"issue":"1","key":"5625_CR14","doi-asserted-by":"publisher","first-page":"683","DOI":"10.21608\/edj.2021.80516.1675","volume":"68","author":"N Abdel Nabi","year":"2022","unstructured":"Abdel Nabi N, Ragheb Nourhan. Evaluation of bone height changes in three implants retained mandibular overdenture using three different attachment design. A randomized clinical trial. Egypt Dent J. 2022;68(1):683\u201396.","journal-title":"Egypt Dent J"},{"issue":"1","key":"5625_CR15","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1186\/s12903-022-02262-7","volume":"22","author":"HI Nassar","year":"2022","unstructured":"Nassar HI, Abdelaziz MS. Retention of bar clip attachment for mandibular implant overdenture. BMC Oral Health. 2022;22(1):227.","journal-title":"BMC Oral Health"},{"key":"5625_CR16","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1007\/s00784-014-1307-1","volume":"19","author":"R Schweyen","year":"2015","unstructured":"Schweyen R, Beuer F, Arnold C, Hey J. Retentive characteristics of avinylpolysiloxane overdenture attachment system. Clin Oral Investig. 2015;19:947\u201353.","journal-title":"Clin Oral Investig"},{"key":"5625_CR17","first-page":"1425","volume":"23","author":"R Schweyen","year":"2019","unstructured":"Schweyen R, Arnold C, Setz JM, Hey J. Retentive characteristics of individual and prefabricated polyvinylsiloxane overdenture attachments: alternative treatment options for geriatric patients. ClinOral Investig. 2019;23:1425\u201334.","journal-title":"ClinOral Investig"},{"issue":"D","key":"5625_CR18","doi-asserted-by":"publisher","first-page":"47","DOI":"10.3889\/oamjms.2021.5829","volume":"9","author":"RTK Elbeheiry","year":"2021","unstructured":"Elbeheiry RTK, Mohamed GF, Badr AMI. Evaluation of Maximum Biting Force in two different attachment systems (Bollard vs. Ball and Socket) retaining Mandibular overdenture: a Split-mouth design. Open Access Maced J Med Sci. 2021;9(D):47\u201353.","journal-title":"Open Access Maced J Med Sci"},{"issue":"2","key":"5625_CR19","doi-asserted-by":"publisher","first-page":"73","DOI":"10.21608\/mjmr.2022.249403","volume":"33","author":"M Faried","year":"2022","unstructured":"Faried M, Mohamed G. A comparison between implant retained mandibular overdenture using Bullard abutments versus ball and socket abutments (clinical assessment). Minia J Med Res. 2022;33(2):73\u20139.","journal-title":"Minia J Med Res"},{"issue":"6","key":"5625_CR20","doi-asserted-by":"publisher","first-page":"895","DOI":"10.21608\/mjcu.2022.253195","volume":"90","author":"A El Sharkawy","year":"2022","unstructured":"El Sharkawy A, Ezz Eldin A. Evaluation of strains around distally inclined implants retaining mandibular overdenture with ti si snap attachment. Med J Cairo Univ. 2022;90(6):895\u2013905.","journal-title":"Med J Cairo Univ"},{"issue":"4","key":"5625_CR21","doi-asserted-by":"publisher","first-page":"22","DOI":"10.21608\/adjalexu.2023.273770","volume":"47","author":"G Enan","year":"2023","unstructured":"Enan G, Abdelhakim A, Elsharkawy A, Adly M. Evaluation of retention and release period in labially inclined implant retained mandibular overdentures with titanum-silicone snap attachments (comparative in vitro study). Alexandria Dent J. 2023;47(4):22\u201322.","journal-title":"Alexandria Dent J"},{"key":"5625_CR22","doi-asserted-by":"publisher","first-page":"910","DOI":"10.1016\/j.triboint.2005.07.016","volume":"38","author":"N Myshkin","year":"2005","unstructured":"Myshkin N, Petrokovets M, Kovalev A. Tribology of polymers: adhesion, friction, wear, and mass-transfer. Tribol Int. 2005;38:910\u201321. [CrossRef].","journal-title":"Tribol Int"},{"key":"5625_CR23","doi-asserted-by":"publisher","first-page":"159","DOI":"10.4103\/0972-4052.176520","volume":"16","author":"T Shastry","year":"2016","unstructured":"Shastry T, Anupama N, Shetty S, Nalinakshamma M. An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures. J Indian Prosthodont Soc. 2016;16:159. [CrossRef] [PubMed].","journal-title":"J Indian Prosthodont Soc"},{"key":"5625_CR24","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1111\/j.1708-8208.2009.00154.x","volume":"12","author":"WK Kleis","year":"2010","unstructured":"Kleis WK, K\u00e4mmerer PW, Hartmann S, Al-Nawas B., W. A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report. Clin Implant Dent Relat Res. 2010;12:209\u201318. [CrossRef].","journal-title":"Clin Implant Dent Relat Res"},{"key":"5625_CR25","doi-asserted-by":"publisher","first-page":"1079","DOI":"10.11607\/jomi.6023","volume":"33","author":"JW Choi","year":"2018","unstructured":"Choi JW, Yun BH, Jeong CM, Huh JB. Retentive properties of two stud attachments with polyetherketoneketone or Nylon Insert in Mandibular Implant overdentures. Int J Oral Maxillofac Implants. 2018;33:1079\u201388. [CrossRef].","journal-title":"Int J Oral Maxillofac Implants"},{"key":"5625_CR26","doi-asserted-by":"crossref","unstructured":"Ernst CP, Canbek K, Euler T, Willershausen B. In vivo validation of the historical in vitro thermocycling temperature range for dental materials testing. Clin Oral Investig. 2004;8(3).","DOI":"10.1007\/s00784-004-0267-2"},{"issue":"4","key":"5625_CR27","doi-asserted-by":"publisher","first-page":"380","DOI":"10.4103\/0972-4052.191284","volume":"16","author":"K Reda","year":"2016","unstructured":"Reda K, El-Torky I, EL-Gendy M. In vitro retention force measurement for three different attachment systems for implant-retained overdenture. J Indian Prosthodontic Soc. 2016;16(4):380.","journal-title":"J Indian Prosthodontic Soc"},{"issue":"4","key":"5625_CR28","doi-asserted-by":"publisher","first-page":"3475","DOI":"10.21608\/edj.2022.144047.2145","volume":"68","author":"A Alam-Eldein","year":"2022","unstructured":"Alam-Eldein A. Evaluation of denture Adhesive versus single Implant on Complete Denture Retention and patient satisfaction. Egypt Dent J. 2022;68(4):3475\u201386.","journal-title":"Egypt Dent J"},{"key":"5625_CR29","unstructured":"Mohamed Rana, Cheta N, Alkady D, Borg H. Retention and wear evaluation of rigid telescopic and Nova Loc attachments for two Implant-supported Mandibular overdentures (an in vitro study). Br J Med Health Res. 2022;8(03)."},{"issue":"4","key":"5625_CR30","doi-asserted-by":"publisher","first-page":"100072","DOI":"10.1016\/j.dentre.2023.100072","volume":"3","author":"I Tsolianos","year":"2023","unstructured":"Tsolianos I, Haidich AB, Goulis DG, Kotsiomiti E. The effect of mandibular implant overdentures on masticatory performance: a systematic review and meta-analysis. Dentistry Rev. 2023;3(4):100072.","journal-title":"Dentistry Rev"},{"issue":"3","key":"5625_CR31","first-page":"110","volume":"46","author":"E Ebiary Mohamed","year":"2021","unstructured":"Ebiary Mohamed E, Lubna, Abdelhakim A. Comparative study of bar, positioner and ball attachment in solitary versus splinted implant assisted mandibular overdenture (in vitro study). Alexandria Dent J. 2021;46(3):110\u20136.","journal-title":"Alexandria Dent J"},{"issue":"1","key":"5625_CR32","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1186\/s12903-024-04256-z","volume":"24","author":"M Zarbah","year":"2024","unstructured":"Zarbah M, Aldowah O, Alqahtani NM, Alqahtani SA, Alamri M, Alshahrani R, et al. Dimensional stability of 3D-printed edentulous and fully dentate hollowed maxillary models over periods of time. BMC Oral Health. 2024;24(1):495.","journal-title":"BMC Oral Health"},{"issue":"6","key":"5625_CR33","first-page":"6358","volume":"12","author":"S Zaky","year":"2023","unstructured":"Zaky S. Effect of two different all-on-four concept framework materials on stress-induced in the supporting structures of implants: an in vitro comparative study. Eur Chem Bull. 2023;12(6):6358\u201366.","journal-title":"Eur Chem Bull"},{"issue":"1","key":"5625_CR34","doi-asserted-by":"publisher","first-page":"445","DOI":"10.21608\/edj.2019.72720","volume":"65","author":"M Nabhan","year":"2019","unstructured":"Nabhan M. Effect of different fixed detachable implant supported prosthesis materials on the stresses induced on the supporting structures. Egypt Dent J. 2019;65(1):445\u201352.","journal-title":"Egypt Dent J"},{"issue":"1","key":"5625_CR35","first-page":"101","volume":"4","author":"RC Patil","year":"2018","unstructured":"Patil RC, Cune MS, Lobo TM, Patil RC. Bone dimension assessment for placement of implants in the interforaminal region of the mandible: a cone beam computed tomography study. \u223c 101\u2009\u223c\u2009International. J Appl Dent Sci. 2018;4(1):101\u20135.","journal-title":"J Appl Dent Sci"},{"issue":"6","key":"5625_CR36","doi-asserted-by":"publisher","first-page":"938","DOI":"10.4012\/dmj.2016-181","volume":"35","author":"E Ma","year":"2016","unstructured":"Ma E, Aa E, Khirallah As. The effect of implant diameter on strain around implants retaining a mandibular overdenture with locator attachments: an in vitro study study. Dent Mater J. 2016;35(6):938\u201345.","journal-title":"Dent Mater J"},{"issue":"2","key":"5625_CR37","first-page":"15","volume":"11","author":"S Alzahrani","year":"2023","unstructured":"Alzahrani S, Alshamrani AS. Comparison of different techniques of copying dentures. Int J Dent Sci Res. 2023;11(2):15\u201320.","journal-title":"Int J Dent Sci Res"},{"issue":"3","key":"5625_CR38","doi-asserted-by":"publisher","first-page":"311","DOI":"10.11607\/ijp.6882","volume":"35","author":"E Y\u0131lmaz","year":"2022","unstructured":"Y\u0131lmaz E, Gencel B, Geckili O, Sakar O. Comparison of the retention of conventional and polyvinyl siloxane matrix materials with different patrices for implant-retained overdentures: an in vitro study. Int J Prosthodont. 2022;35(3):311\u20138.","journal-title":"Int J Prosthodont"},{"issue":"2","key":"5625_CR39","doi-asserted-by":"publisher","first-page":"1501","DOI":"10.21608\/edj.2023.196818.2465","volume":"69","author":"S Aboutar","year":"2023","unstructured":"Aboutar S, Elkerdawy M, fayyad ahmed. Effect of cross arch stabilization on the retention of a unilateral distal extension partial denture using a resilient extracoronal attachment: (in vitro study). Egypt Dent J. 2023;69(2):1501\u201315.","journal-title":"Egypt Dent J"},{"issue":"1","key":"5625_CR40","doi-asserted-by":"publisher","first-page":"377","DOI":"10.21608\/edj.2023.235049.2712","volume":"70","author":"M Hassan","year":"2024","unstructured":"Hassan M, Elsarrif H. A comparative study of different cad\/cam materials reinforcing implant retained overdenture base material (an in vitro study). Egypt Dent J. 2024;70(1):377\u201385.","journal-title":"Egypt Dent J"},{"issue":"1","key":"5625_CR41","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.jobcr.2022.11.001","volume":"13","author":"N Gupta","year":"2023","unstructured":"Gupta N, Bansal R, Shukla NK. The effect of ball versus locator attachment system on the performance of implant supported overdenture: a systematic review. J Oral Biol Craniofac Res. 2023;13(1):44\u201355.","journal-title":"J Oral Biol Craniofac Res"},{"issue":"7","key":"5625_CR42","doi-asserted-by":"publisher","first-page":"953","DOI":"10.4317\/medoral.17312","volume":"16","author":"S Cakarer","year":"2011","unstructured":"Cakarer S, Can T, Yaltirik M, Keskin C. Complications associated with the ball, bar and locator attachments for implant-supported overdentures. Med Oral Patol Oral Cir Bucal. 2011;16(7):953\u20139.","journal-title":"Med Oral Patol Oral Cir Bucal"},{"issue":"3","key":"5625_CR43","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1111\/j.1708-8208.2009.00154.x","volume":"12","author":"WK Kleis","year":"2010","unstructured":"Kleis WK, K\u00e4mmerer PW, Hartmann S, Al-Nawas B, Wagner W. A comparison of three different attachment systems for mandibular two\u2010implant overdentures: one\u2010year report. Clin Implant Dent Relat Res. 2010;12(3):209\u201318.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"1","key":"5625_CR44","doi-asserted-by":"publisher","first-page":"181","DOI":"10.21608\/adjalexu.2022.116200.1247","volume":"48","author":"D Abou Warda","year":"2023","unstructured":"Abou Warda D, Sharkawy Ahlam, Abdel Hakim A, Alabbassy F. Evaluation of strain around labially inclined implants retaining mandibular overdentures with titanium-silicone attachments (comparative in vitro study). Alexandria Dent J. 2023;48(1):181\u20137.","journal-title":"Alexandria Dent J"},{"issue":"4","key":"5625_CR45","first-page":"71","volume":"4","author":"S Arora","year":"2017","unstructured":"Arora S, Mittal S. Comparative evaluation of alteration in retention force values of different attachment systems for implant overdenture over various time intervals: an in vitro study. Int J Innovative Res Adv Stud (IJIRAS). 2017;4(4):71\u20136.","journal-title":"Int J Innovative Res Adv Stud (IJIRAS)"},{"issue":"1","key":"5625_CR46","doi-asserted-by":"publisher","first-page":"65","DOI":"10.21608\/adjg.2020.42237.1294","volume":"8","author":"D Rostom","year":"2021","unstructured":"Rostom D, Sheta N. Evaluation of the retention of two different retention mechanisms (nylon caps and retention sil) in locators retained implant mandibular overdenture. A randomized clinical trial (rct). Al-Azhar Dent J Girls. 2021;8(1):65\u201370.","journal-title":"Al-Azhar Dent J Girls"},{"issue":"12","key":"5625_CR47","doi-asserted-by":"publisher","first-page":"3925","DOI":"10.3390\/molecules27123925","volume":"27","author":"A Chindarungruangrat","year":"2022","unstructured":"Chindarungruangrat A, Eiampongpaiboon T, Jirajariyavej B. Effect of various retentive element materials on retention of mandibular implant-retained overdentures. Molecules. 2022;27(12):3925\u201334.","journal-title":"Molecules"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05625-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-05625-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05625-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,28]],"date-time":"2025-02-28T02:31:35Z","timestamp":1740709895000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-05625-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,28]]},"references-count":47,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5625"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-05625-y","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,28]]},"assertion":[{"value":"15 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 February 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical committee exemption. As it is a non\u2013human subject.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Clinical trial number"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"318"}}