{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T10:51:45Z","timestamp":1788778305246,"version":"build-2803163510"},"reference-count":56,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,15]],"date-time":"2025-03-15T00:00:00Z","timestamp":1741996800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,15]],"date-time":"2025-03-15T00:00:00Z","timestamp":1741996800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100024743","name":"Suez Canal University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100024743","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Zirconia crowns are the most common aesthetic option for full coverage in pediatric dentistry. Bioflx crowns have been recently introduced, offering a unique combination of aesthetics, flexibility, and durability.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Aim<\/jats:title>\n            <jats:p>The objective of this study was to evaluate and compare the wear of the crowns and opposing enamel. Additionally, to assess the color stability of Bioflx pediatric crowns following thermodynamic aging compared to zirconia crowns.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Forty acrylic resin dies were fabricated based on specific criteria and equally divided into two groups: zirconia crowns and Bioflx crowns. Thermodynamic cycling was conducted to simulate oral conditions over six months. Wear resistance was quantitatively assessed utilizing a Universal Serial Bus (USB) digital microscope with an integrated camera. Color stability was measured using a spectrophotometer before and after thermal aging and following immersion in various solutions (water, milk chocolate, orange juice, and cola). Data were collected, tabulated, and statistically analyzed using the Shapiro\u2013Wilk test and paired sample t-tests. The level of statistical significance was set at a <jats:italic>p<\/jats:italic>-value of 0.05.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>A statistically significant difference was observed between zirconia and Bioflx crowns regarding volume loss and average roughness height [\u00b5m] of the opposing enamel (<jats:italic>P<\/jats:italic>\u2009=\u20090.021 and 0.001, respectively). Furthermore, there were significant differences in volume loss (\u00b5m<jats:sup>3<\/jats:sup>) and average roughness height (\u00b5m) between the zirconia and Bioflx crowns (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001). In contrast, the results of color change revealed non-significant differences between zirconia and Bioflx crowns (<jats:italic>P<\/jats:italic>\u2009=\u20090.470) before and after thermocycling aging, as well as following immersion in different solutions.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Zirconia crowns cause more wear on opposing natural teeth than Bioflx crowns. Bioflx crowns show a higher average wear rate than zirconia. There are no significant differences between the two crown\u2019s materials in terms of color change after aging and immersion in various solutions.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s12903-025-05672-5","type":"journal-article","created":{"date-parts":[[2025,3,15]],"date-time":"2025-03-15T14:36:11Z","timestamp":1742049371000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Wear resistance and color stability of innovate esthetical Bioflx crowns compared to zirconia pediatric crowns"],"prefix":"10.1186","volume":"25","author":[{"given":"Noha El-Sayed Fathi","family":"Abdou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eman Mohamed","family":"Mohamady","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tarek Mohamed Nabil Mohamed Kamel","family":"Mahmoud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asmaa Ali Emam","family":"Abo-Elsoud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,15]]},"reference":[{"key":"5672_CR1","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1186\/s12903-023-03254-x","volume":"23","author":"E Delikan","year":"2023","unstructured":"Delikan E, \u00c7aliskan S, \u00c7al\u0131\u015fkan A, \u00d6zdemir C. Does repeated autoclave sterilization cause changes in the color and fragility of fiberglass reinforced resin crowns? BMC Oral Health. 2023;23:533.","journal-title":"BMC Oral Health"},{"key":"5672_CR2","doi-asserted-by":"publisher","first-page":"191","DOI":"10.2174\/1874210601004010191","volume":"4","author":"L Giacomelli","year":"2010","unstructured":"Giacomelli L, et al. Surface roughness of commercial composites after different polishing protocols: an analysis with atomic force microscopy. Open Dent J. 2010;4:191\u20134.","journal-title":"Open Dent J"},{"key":"5672_CR3","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1016\/j.adaj.2017.08.048","volume":"149","author":"J-H Lee","year":"2018","unstructured":"Lee J-H. Guided tooth preparation for a pediatric zirconia crown. J Am Dent Assoc. 2018;149:202-208.e2.","journal-title":"J Am Dent Assoc"},{"key":"5672_CR4","doi-asserted-by":"publisher","first-page":"1940","DOI":"10.37358\/RC.17.8.5796","volume":"68","author":"C Bica","year":"2017","unstructured":"Bica C, et al. Applicability of zirconia-prefabricated crowns in children with primary dentition. Rev Chim. 2017;68:1940\u20133.","journal-title":"Rev Chim"},{"key":"5672_CR5","doi-asserted-by":"publisher","first-page":"37","DOI":"10.4103\/JISPPD.JISPPD_484_23","volume":"42","author":"AS Patil","year":"2024","unstructured":"Patil AS, Jain M, Choubey S, Patil M, Chunawala Y. Comparative evaluation of clinical success of Stainless Steel and Bioflx crowns in primary molar \u2013 A 12 month split mouth prospective randomized clinical trial. J Indian Soc Pedodont Prev Dent. 2024;42:37\u201345.","journal-title":"J Indian Soc Pedodont Prev Dent"},{"key":"5672_CR6","first-page":"e52997","volume":"16","author":"OS Almajed","year":"2024","unstructured":"Almajed OS. Shaping smiles: A narrative review of crown advancements in pediatric dentistry. Cureus. 2024;16:e52997.","journal-title":"Cureus"},{"key":"5672_CR7","doi-asserted-by":"publisher","first-page":"80","DOI":"10.20473\/j.djmkg.v57.i2.p80-86","volume":"57","author":"S Deolikar","year":"2024","unstructured":"Deolikar S, Rathi N, Mehta V. Comparative evaluation of stress generation in primary teeth restored with zirconia and BioFlx crowns: A finite element analysis. Dent J. 2024;57:80\u20136.","journal-title":"Dent J"},{"key":"5672_CR8","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1016\/S0022-3913(97)70043-X","volume":"78","author":"BG Smith","year":"1997","unstructured":"Smith BG, Bartlett DW, Robb ND. The prevalence, etiology and management of tooth wear in the United Kingdom. J Prosthet Dent. 1997;78:367\u201372.","journal-title":"J Prosthet Dent"},{"key":"5672_CR9","first-page":"141","volume":"24","author":"LH Mair","year":"1996","unstructured":"Mair LH, Stolarski TA, Vowles RW, Lloyd CH. Wear: mechanisms, manifestations and measurement. Report of a workshop J Dent. 1996;24:141\u20138.","journal-title":"Report of a workshop J Dent"},{"key":"5672_CR10","doi-asserted-by":"publisher","first-page":"1735","DOI":"10.1177\/00220345990780111101","volume":"78","author":"D Bani","year":"1999","unstructured":"Bani D, Bani T, Bergamini M. Morphologic and biochemical changes of the masseter muscles induced by occlusal wear: studies in a rat model. J Dent Res. 1999;78:1735\u201344.","journal-title":"J Dent Res"},{"key":"5672_CR11","doi-asserted-by":"publisher","first-page":"233","DOI":"10.4103\/0970-4388.186740","volume":"34","author":"H Adusumilli","year":"2016","unstructured":"Adusumilli H, et al. Color stability of esthetic restorative materials used in pediatric dentistry: An in vitro study. J Indian Soc Pedod Prev Dent. 2016;34:233\u20137.","journal-title":"J Indian Soc Pedod Prev Dent"},{"key":"5672_CR12","doi-asserted-by":"publisher","first-page":"175","DOI":"10.3758\/BF03193146","volume":"39","author":"F Faul","year":"2007","unstructured":"Faul F, Erdfelder E, Lang A-G, Buchner A. G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39:175\u201391.","journal-title":"Behav Res Methods"},{"key":"5672_CR13","doi-asserted-by":"crossref","unstructured":"el habashy, laila m & Aboushelib, O. A. Fatigue and 3-D wear resistance of Fiberglass versus Stainless steel crowns for restoration of primary teeth. Egypt Dent J\u00a02021;67:1835-1841.","DOI":"10.21608\/edj.2021.66162.1539"},{"key":"5672_CR14","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.sdentj.2017.07.006","volume":"29","author":"MZ Al Shobber","year":"2017","unstructured":"Al Shobber MZ, Alkhadra TA. Fracture resistance of different primary anterior esthetic crowns. Saudi Dent J. 2017;29:179\u201384.","journal-title":"Saudi Dent J"},{"key":"5672_CR15","first-page":"20218","volume":"25","author":"NR Salman","year":"2021","unstructured":"Salman NR, Khattab NM, Gomaa YF, Elheeny AA. Assessment of the external marginal adaptation of prefabricated zirconia crowns for restoring primary molars using a stereomicroscope. Ann Rom Soc Cell Biol. 2021;25:20218\u201326.","journal-title":"Ann Rom Soc Cell Biol"},{"key":"5672_CR16","doi-asserted-by":"publisher","first-page":"313","DOI":"10.4103\/njcp.njcp_358_18","volume":"22","author":"A Bolaca","year":"2019","unstructured":"Bolaca A, Erdogan Y. In Vitro evaluation of the wear of primary tooth enamel against different ceramic and composite resin materials. Niger J Clin Pract. 2019;22:313\u20139.","journal-title":"Niger J Clin Pract"},{"key":"5672_CR17","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/j.jmbbm.2013.09.013","volume":"29","author":"AL Morresi","year":"2014","unstructured":"Morresi AL, et al. Thermal cycling for restorative materials: does a standardized protocol exist in laboratory testing? A literature review. J Mech Behav Biomed Mater. 2014;29:295\u2013308.","journal-title":"J Mech Behav Biomed Mater"},{"key":"5672_CR18","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1111\/jopr.12376","volume":"25","author":"N Nawafleh","year":"2016","unstructured":"Nawafleh N, Hatamleh M, Elshiyab S, Mack F. Lithium disilicate restorations fatigue testing parameters: A systematic review. J Prosthodont. 2016;25:116\u201326.","journal-title":"J Prosthodont"},{"key":"5672_CR19","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1186\/s12903-022-02628-x","volume":"22","author":"OI El Shahawy","year":"2022","unstructured":"El Shahawy OI, Azab MM. Fracture resistance of prefabricated versus custom-made zirconia crowns after thermo-mechanical aging: an in-vitro study. BMC Oral Health. 2022;22:587.","journal-title":"BMC Oral Health"},{"key":"5672_CR20","first-page":"698","volume":"1","author":"OB Abouelatta","year":"2010","unstructured":"Abouelatta OB. 3D surface roughness measurement using a light sectioning vision system. WCE 2010 - World Congress on Engineering. 2010;1:698\u2013703.","journal-title":"WCE 2010 - World Congress on Engineering"},{"key":"5672_CR21","doi-asserted-by":"publisher","first-page":"43","DOI":"10.22271\/oral.2023.v9.i2a.1712","volume":"9","author":"MA Ali","year":"2023","unstructured":"Ali MA, Nabil O, Elnaggar GAE. Surface roughness and translucency of glazed versus polished cubic ultra-translucent multi-layered zirconia: An in-vitro study. Int J Appl Dent Sci. 2023;9:43\u201353.","journal-title":"Int J Appl Dent Sci"},{"key":"5672_CR22","doi-asserted-by":"publisher","first-page":"1153","DOI":"10.21608\/edj.2016.95433","volume":"62","author":"A Elkady","year":"2016","unstructured":"Elkady A, Gad E. Surface roughness of root canal dentin following mechanical preparation using different endodontic file systems. Egypt Dent J. 2016;62:1153\u201360.","journal-title":"Egypt Dent J"},{"key":"5672_CR23","doi-asserted-by":"publisher","first-page":"189","DOI":"10.2174\/1874210601206010189","volume":"6","author":"L Giacomelli","year":"2012","unstructured":"Giacomelli L. Erratum - surface roughness of commercial composites after different polishing protocols: an analysis with atomic force microscopy. Open Dent J. 2012;6:189\u2013189.","journal-title":"Open Dent J"},{"key":"5672_CR24","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s10856-006-0675-8","volume":"18","author":"A Kakaboura","year":"2007","unstructured":"Kakaboura A, Fragouli M, Rahiotis C, Silikas N. Evaluation of surface characteristics of dental composites using profilometry, scanning electron, atomic force microscopy and gloss-meter. J Mater Sci Mater Med. 2007;18:155\u201363.","journal-title":"J Mater Sci Mater Med"},{"key":"5672_CR25","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1590\/2176-9451.19.4.114-121.oar","volume":"19","author":"CB de Oliveira","year":"2014","unstructured":"de Oliveira CB, Martins Maia LG, Santos-Pinto A, Gandini J\u00fanior LG. In vitro study of color stability of polycrystalline and monocrystalline ceramic brackets. Dental Press J Orthod. 2014;19:114\u201321.","journal-title":"Dental Press J Orthod"},{"key":"5672_CR26","doi-asserted-by":"publisher","first-page":"147","DOI":"10.17796\/jcpd.34.2.953q255621436788","volume":"34","author":"ES Tunc","year":"2009","unstructured":"Tunc ES, Bayrak S, Guler AU, Tuloglu N. The effects of children\u2019s drinks on the color stability of various restorative materials. J Clin Pediatr Dent. 2009;34:147\u201350.","journal-title":"J Clin Pediatr Dent"},{"key":"5672_CR27","unstructured":"https:\/\/nusmile.com\/pages\/bioflx."},{"key":"5672_CR28","doi-asserted-by":"publisher","first-page":"43","DOI":"10.22271\/oral.2023.v9.i2a.1712","volume":"9","author":"MA Ali","year":"2023","unstructured":"Ali MA, Nabil O, Elnaggar GAE. Surface roughness and translucency of glazed versus polished cubic ultra-translucent multi-layered zirconia: An in-vitro study. Int J Appl Dent Sci. 2023;9:43\u201353.","journal-title":"Int J Appl Dent Sci"},{"key":"5672_CR29","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1016\/S0109-5641(86)80016-1","volume":"2","author":"R DeLong","year":"1986","unstructured":"DeLong R, Douglas WH, Sakaguchi RL, Pintado MR. The wear of dental porcelain in an artificial mouth. Dent Mater. 1986;2:214\u20139.","journal-title":"Dent Mater"},{"key":"5672_CR30","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.dental.2007.06.016","volume":"24","author":"SD Heintze","year":"2008","unstructured":"Heintze SD, Cavalleri A, Forjanic M, Zellweger G, Rousson V. Wear of ceramic and antagonist\u2014A systematic evaluation of influencing factors in vitro. Dent Mater. 2008;24:433\u201349.","journal-title":"Dent Mater"},{"key":"5672_CR31","doi-asserted-by":"publisher","first-page":"713","DOI":"10.1177\/00220345990780021201","volume":"78","author":"I Krejci","year":"1999","unstructured":"Krejci I, Albert P, Lutz F. The influence of antagonist standardization on wear. J Dent Res. 1999;78:713\u20139.","journal-title":"J Dent Res"},{"key":"5672_CR32","doi-asserted-by":"publisher","first-page":"43","DOI":"10.4047\/jap.2016.8.1.43","volume":"8","author":"JW Choi","year":"2016","unstructured":"Choi JW, et al. Wear of primary teeth caused by opposed allceramic or stainless steel crowns. J Adv Prosthodont. 2016;8:43\u201352.","journal-title":"J Adv Prosthodont"},{"key":"5672_CR33","doi-asserted-by":"publisher","first-page":"2599","DOI":"10.1016\/j.jeurceramsoc.2012.03.021","volume":"32","author":"L Wang","year":"2012","unstructured":"Wang L, et al. Friction and wear behaviors of dental ceramics against natural tooth enamel. J Eur Ceram Soc. 2012;32:2599\u2013606.","journal-title":"J Eur Ceram Soc"},{"key":"5672_CR34","first-page":"80","volume":"15","author":"GMM Aly","year":"2016","unstructured":"Aly GMM, Ahmed DM, Saad NM. Quantitative and qualitative assessment of the wear of primary enamel against three types of full coronal coverage. Oral Health Dent Manag. 2016;15:80\u20136.","journal-title":"Oral Health Dent Manag"},{"key":"5672_CR35","doi-asserted-by":"publisher","first-page":"15","DOI":"10.5005\/jp-journals-10005-2134","volume":"15","author":"R Agrawal","year":"2022","unstructured":"Agrawal R, Khanduja R, Singhal M, Gupta S, Kaushik M. Clinical Evaluation of Stainless Steel Crown versus Zirconia Crown in Primary Molars: An In Vivo Study. Int J Clin Pediatr Dent. 2022;15:15\u20139.","journal-title":"Int J Clin Pediatr Dent"},{"key":"5672_CR36","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1016\/j.jdent.2007.07.008","volume":"35","author":"basic properties and clinical applications","year":"2007","unstructured":"basic properties and clinical applications. Manicone, P. F., Rossi Iommetti, P. & Raffaelli, L. An overview of zirconia ceramics. J Dent. 2007;35:819\u201326.","journal-title":"J Dent"},{"key":"5672_CR37","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.1016\/j.prosdent.2014.05.006","volume":"112","author":"J Sripetchdanond","year":"2014","unstructured":"Sripetchdanond J, Leevailoj C. Wear of human enamel opposing monolithic zirconia, glass ceramic, and composite resin: an in vitro study. J Prosthet Dent. 2014;112:1141\u201350.","journal-title":"J Prosthet Dent"},{"key":"5672_CR38","first-page":"52","volume":"45","author":"JK-C Peng","year":"2023","unstructured":"Peng JK-C, Chen J-W, Savignano R, Goodacre B. Wear resistance comparison of prefabricated primary crowns using a Novel 3D computed tomography method. Pediatr Dent. 2023;45:52\u20139.","journal-title":"Pediatr Dent"},{"key":"5672_CR39","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12903-021-01452-z","volume":"21","author":"Z Tang","year":"2021","unstructured":"Tang Z, Zhao X, Wang H. Quantitative analysis on the wear of monolithic zirconia crowns on antagonist teeth. BMC Oral Health. 2021;21:1\u201311.","journal-title":"BMC Oral Health"},{"key":"5672_CR40","first-page":"519","volume":"38","author":"D Johnson-Harris","year":"2016","unstructured":"Johnson-Harris D, Chiquet B, Flaitz C, Badger G, Frey G. Wear of primary tooth enamel by ceramic materials. Pediatr Dent. 2016;38:519\u201322.","journal-title":"Pediatr Dent"},{"key":"5672_CR41","doi-asserted-by":"publisher","first-page":"61","DOI":"10.4103\/aihb.aihb_43_22","volume":"13","author":"R Bhatt","year":"2023","unstructured":"Bhatt R, Shah D, Patel M, Khurana S. Clinical evaluation and parental and child satisfaction with restoration of primary teeth using zirconia and stainless steel crowns: A randomised clinical study. Adv Human Biol. 2023;13:61\u20137.","journal-title":"Adv Human Biol"},{"key":"5672_CR42","unstructured":"https:\/\/instituteofdigitaldentistry.com\/cad-cam\/glazing-vs-polishing-dental-ceramics-which-is-best\/."},{"key":"5672_CR43","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/S0022-3913(13)60005-0","volume":"109","author":"S Janyavula","year":"2013","unstructured":"Janyavula S, et al. The wear of polished and glazed zirconia against enamel. J Prosthet Dent. 2013;109:22\u20139.","journal-title":"J Prosthet Dent"},{"key":"5672_CR44","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.jmbbm.2013.12.018","volume":"32","author":"ACL Faria","year":"2014","unstructured":"Faria ACL, de Oliveira AA, Gomes \u00c9A, Rodrigues RCS, Ribeiro RF. Wear resistance of a pressable low-fusing ceramic opposed by dental alloys. J Mech Behav Biomed Mater. 2014;32:46\u201351.","journal-title":"J Mech Behav Biomed Mater"},{"key":"5672_CR45","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1007\/s00784-018-2473-3","volume":"23","author":"M Matzinger","year":"2019","unstructured":"Matzinger M, Hahnel S, Preis V, Rosentritt M. Polishing effects and wear performance of chairside CAD\/CAM materials. Clin Oral Investig. 2019;23:725\u201337.","journal-title":"Clin Oral Investig"},{"key":"5672_CR46","doi-asserted-by":"publisher","first-page":"147","DOI":"10.17796\/jcpd.34.2.953q255621436788","volume":"34","author":"ES Tunc","year":"2009","unstructured":"Tunc ES, Bayrak S, Guler AU, Tuloglu N. The effects of children\u2019s drinks on the color stability of various restorative materials. J Clin Pediatr Dent. 2009;34:147\u201350.","journal-title":"J Clin Pediatr Dent"},{"key":"5672_CR47","doi-asserted-by":"crossref","unstructured":"Allam GG, Abd El Aziz AM, El Korashy DI, Al Sakaf MH, Khalifa MZ. Effect of Different Beverages on Colour Stability, Surface Roughness and Surface Hardness of Beauticoat Tooth Surface Coating Material. Biomed J Sci Tech Res. 2019;21:16280-16285.","DOI":"10.26717\/BJSTR.2019.21.003679"},{"key":"5672_CR48","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1111\/jerd.12149","volume":"27","author":"RD Paravina","year":"2015","unstructured":"Paravina RD, et al. Color difference thresholds in dentistry. J Esthet Restor Dent. 2015;27:S1\u20139.","journal-title":"J Esthet Restor Dent"},{"key":"5672_CR49","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1016\/j.jdent.2013.11.017","volume":"42","author":"G Khashayar","year":"2014","unstructured":"Khashayar G, et al. Perceptibility and acceptability thresholds for colour differences in dentistry. J Dent. 2014;42:637\u201344.","journal-title":"J Dent"},{"key":"5672_CR50","first-page":"284","volume":"11","author":"S \u015ei\u015fmano\u011flu","year":"2021","unstructured":"\u015ei\u015fmano\u011flu S, G\u00fcrcan AT. Evaluation of stain susceptibility of different CAD\/CAM blocks after immersion in coffee. D\u00fczce \u00dcniversitesi Sa\u011fl\u0131k Bilimleri Enstit\u00fcs\u00fc Dergisi. 2021;11:284\u20139.","journal-title":"D\u00fczce \u00dcniversitesi Sa\u011fl\u0131k Bilimleri Enstit\u00fcs\u00fc Dergisi"},{"key":"5672_CR51","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/j.jdent.2004.10.018","volume":"33","author":"R Bagheri","year":"2005","unstructured":"Bagheri R, Burrow MF, Tyas M. Influence of food-simulating solutions and surface finish on susceptibility to staining of aesthetic restorative materials. J Dent. 2005;33:389\u201398.","journal-title":"J Dent"},{"key":"5672_CR52","doi-asserted-by":"publisher","first-page":"120","DOI":"10.17796\/1053-4628-41.2.120","volume":"41","author":"AN Habib","year":"2017","unstructured":"Habib AN, Abdelmoniem SA, Mahmoud SA. Effect of children\u2019s drinks on color stability of different dental composites: An in vitro Study. J Clin Pediatr Dent. 2017;41:120\u20135.","journal-title":"J Clin Pediatr Dent"},{"key":"5672_CR53","first-page":"334","volume":"40","author":"PK Taran","year":"2018","unstructured":"Taran PK, Kaya MS. A comparison of periodontal health in primary molars restored with prefabricated stainless steel and zirconia crowns. Pediatr Dent. 2018;40:334\u20139.","journal-title":"Pediatr Dent"},{"key":"5672_CR54","doi-asserted-by":"publisher","first-page":"53","DOI":"10.4103\/jisppd.jisppd_508_20","volume":"39","author":"SKD Padmanabh","year":"2021","unstructured":"Padmanabh SKD, Patel V. The effect of sterilization and disinfection on the physical-mechanical properties of preformed crowns. J Indian Soc Pedodont Prev Dent. 2021;39:53\u201360.","journal-title":"J Indian Soc Pedodont Prev Dent"},{"key":"5672_CR55","doi-asserted-by":"publisher","first-page":"2838","DOI":"10.3390\/ijerph19052838","volume":"19","author":"SD Alzanbaqi","year":"2022","unstructured":"Alzanbaqi SD, et al. Zirconia crowns for primary teeth: a systematic review and meta-analyses. Int J Environ Res Public Health. 2022;19:2838.","journal-title":"Int J Environ Res Public Health"},{"key":"5672_CR56","doi-asserted-by":"publisher","first-page":"3280","DOI":"10.3390\/ma12203280","volume":"12","author":"V Diener","year":"2019","unstructured":"Diener V, Polychronis G, Erb J, Zinelis S, Eliades T. Surface, microstructural, and mechanical characterization of prefabricated pediatric zirconia crowns. Materials. 2019;12:3280.","journal-title":"Materials"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05672-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-05672-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05672-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,16]],"date-time":"2025-03-16T04:03:33Z","timestamp":1742097813000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-05672-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,15]]},"references-count":56,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5672"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-05672-5","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,15]]},"assertion":[{"value":"4 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The Faculty of Dentistry's Research Ethics Committee (REC) at Suez Canal University authorized all procedures involved in this study, under approval number 754\/2023. This approval is in accordance with the World Medical Association\u2019s Helsinki Declaration (Version 2008). Furthermore, informed consent forms were signed by the parents or legal guardians of all children visiting the Department of Pediatric Dentistry at Suez Canal University for extractions, granting permission for the use of their extracted teeth in the research.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"It is not acceptable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"393"}}