{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T15:28:55Z","timestamp":1793892535699,"version":"4.8.0"},"reference-count":52,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T00:00:00Z","timestamp":1741305600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T00:00:00Z","timestamp":1741305600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009827","name":"Alexandria University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100009827","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Interim restorations are essential for preserving structural integrity and function until the definitive restoration is placed. Their mechanical properties and marginal fit are crucial for clinical performance and are influenced by the fabrication technique and material used.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aim<\/jats:title>\n                    <jats:p>The aim of this in vitro study was to investigate the marginal fit and fracture resistance of manually fabricated, computer-aided design and computer-aided manufacturing (CAD\/CAM) milled, and CAD\/CAM three-dimensionally (3D) printed 3-unit interim fixed dental prostheses (FDPs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      Sixty-four 3-unit interim FDPs were fabricated on epoxy resin models using different fabrication techniques: manual fabrication with poly methyl methacrylate (PMMA) (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200916), manual fabrication with Bis-acrylic composite resin (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200916), CAD\/CAM milling (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200916), and CAD\/CAM 3D-printing with a digital light processing (DLP) printer (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200916). The vertical marginal fit of the interim FDPs was evaluated using a stereomicroscope. Following cementation, the specimens were subjected to cyclic loading and then tested for fracture resistance using a universal testing machine. Data were analyzed using one-way ANOVA, and Tukey\u2019s post hoc test was performed to identify statistical differences between the means of independent group pairs.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The smallest marginal gap (31.77\u2009\u00b1\u20099.0\u00a0\u03bcm) was observed in the milling group, followed by the 3D-printing group, with no significant difference between the two (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.98). Both groups demonstrated significantly smaller marginal gaps compared to the manual fabrication groups (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). In terms of fracture resistance, the 3D-printing group showed the highest values (1244.46\u2009\u00b1\u2009290.04\u00a0N), followed by the milling group, with no significant difference between them (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.32). Both groups exhibited significantly higher fracture resistance than the manual fabrication groups (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>CAD\/CAM 3D-printed and milled interim FDPs demonstrated superior marginal fit and fracture resistance, making them more suitable than conventional techniques, particularly for multi-unit restorations or long-term applications.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-025-05679-y","type":"journal-article","created":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T05:58:51Z","timestamp":1741327131000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Evaluation of the marginal fit and fracture resistance of interim restorations fabricated using different techniques: an in vitro study"],"prefix":"10.1186","volume":"25","author":[{"given":"Mostafa","family":"Elashkar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yehia","family":"Aboushady","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Merna","family":"Ihab","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed T.","family":"El Halawani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,7]]},"reference":[{"key":"5679_CR1","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1016\/j.cden.2003.12.007","volume":"48","author":"DG Gratton","year":"2004","unstructured":"Gratton DG, Aquilino SA. Interim restorations. Dent Clin North Am. 2004;48:487\u201397.","journal-title":"Dent Clin North Am"},{"key":"5679_CR2","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1016\/S0022-3913(03)00259-2","volume":"90","author":"DR Burns","year":"2003","unstructured":"Burns DR, Beck DA, Nelson SK. A review of selected dental literature on contemporary provisional fixed prosthodontic treatment: report of the committee on research in fixed prosthodontics of the academy of fixed prosthodontics. J Prosthet Dent. 2003;90:474\u201397.","journal-title":"J Prosthet Dent"},{"key":"5679_CR3","first-page":"97","volume":"17","author":"EJ Givens","year":"2008","unstructured":"Givens EJ, Neiva G, Yaman P, Dennison JB. Marginal adaptation and color stability of four provisional materials. J Prosthet Dent. 2008;17:97\u2013101.","journal-title":"J Prosthet Dent"},{"key":"5679_CR4","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1016\/j.prosdent.2014.12.023","volume":"114","author":"L Pe\u00f1ate","year":"2015","unstructured":"Pe\u00f1ate L, Basilio J, Roig M, Mercad\u00e9 M. Comparative study of interim materials for direct fixed dental prostheses and their fabrication with CAD\/CAM technique. J Prosthet Dent. 2015;114:248\u201353.","journal-title":"J Prosthet Dent"},{"key":"5679_CR5","doi-asserted-by":"publisher","first-page":"218","DOI":"10.4047\/jap.2020.12.4.218","volume":"12","author":"T Reeponmaha","year":"2020","unstructured":"Reeponmaha T, Angwaravong O, Angwarawong T. Comparison of fracture strength after thermo-mechanical aging between provisional crowns made with CAD\/CAM and conventional method. J Adv Prosthodont. 2020;12:218\u201324.","journal-title":"J Adv Prosthodont"},{"issue":"4","key":"5679_CR6","doi-asserted-by":"publisher","first-page":"325","DOI":"10.3390\/prosthesis2040030","volume":"2","author":"KM Suralik","year":"2020","unstructured":"Suralik KM, Sun J, Chen CY, Lee SJ. Effect of fabrication method on fracture strength of provisional implant-supported fixed dental prostheses. Prosthesis. 2020;2(4):325\u201332.","journal-title":"Prosthesis"},{"key":"5679_CR7","doi-asserted-by":"crossref","unstructured":"Henderson JY, Korioth TVP, Tantbirojn D, Versluis A. Failure load of milled, 3D-printed, and conventional chairside-dispensed interim 3-unit fixed dental prostheses. J Prosthet Dent. 2022;127:275. e1-275.e7.","DOI":"10.1016\/j.prosdent.2021.11.005"},{"key":"5679_CR8","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1016\/j.prosdent.2015.03.007","volume":"114","author":"MM Rayyan","year":"2015","unstructured":"Rayyan MM, Aboushelib M, Sayed NM, Ibrahim A, Jimbo R. Comparison of interim restorations fabricated by CAD\/CAM with those fabricated manually. J Prosthet Dent. 2015;114:414\u20139.","journal-title":"J Prosthet Dent"},{"key":"5679_CR9","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.dental.2010.11.012","volume":"27","author":"V Alt","year":"2011","unstructured":"Alt V, Hannig M, W\u00f6stmann B, Balkenhol M. Fracture strength of temporary fixed partial dentures: CAD\/CAM versus directly fabricated restorations. Dent Mater. 2011;27:339\u201347.","journal-title":"Dent Mater"},{"key":"5679_CR10","doi-asserted-by":"publisher","first-page":"27","DOI":"10.4047\/jap.2015.7.1.27","volume":"7","author":"I Karaokutan","year":"2015","unstructured":"Karaokutan I, Sayin G, Kara O. In vitro study of fracture strength of provisional crown materials. J Adv Prosthodont. 2015;7:27\u201331.","journal-title":"J Adv Prosthodont"},{"key":"5679_CR11","doi-asserted-by":"publisher","first-page":"772","DOI":"10.4012\/dmj.2020-232","volume":"40","author":"M Benli","year":"2021","unstructured":"Benli M, Eker-G\u00fcm\u00fc\u015f B, Kahraman Y, Huck O, \u00d6zcan M. Can polylactic acid be a CAD\/CAM material for provisional crown restorations in terms of fit and fracture strength? Dent Mater J. 2021;40:772\u201380.","journal-title":"Dent Mater J"},{"key":"5679_CR12","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1590\/1678-775720150451","volume":"24","author":"AO Abdullah","year":"2016","unstructured":"Abdullah AO, Tsitrou EA, Pollington S. Comparative in vitro evaluation of CAD\/CAM vs conventional provisional crowns. J Appl Oral Sci. 2016;24:258\u201363.","journal-title":"J Appl Oral Sci"},{"issue":"24","key":"5679_CR13","doi-asserted-by":"publisher","first-page":"7791","DOI":"10.3390\/ma14247791","volume":"14","author":"C Abad-Coronel","year":"2021","unstructured":"Abad-Coronel C, Carrera E, Mena C\u00f3rdova N, Fajardo JI, Aliaga P. Comparative analysis of fracture resistance between CAD\/CAM materials for interim fixed prosthesis. Materials. 2021;14(24):7791.","journal-title":"Materials"},{"issue":"3","key":"5679_CR14","doi-asserted-by":"publisher","first-page":"740","DOI":"10.3390\/s21030740","volume":"21","author":"J Wu","year":"2021","unstructured":"Wu J, Xie H, Sadr A, Chung KH. Evaluation of internal fit and marginal adaptation of provisional crowns fabricated with three different techniques. Sens (Basel). 2021;21(3):740.","journal-title":"Sens (Basel)"},{"key":"5679_CR15","doi-asserted-by":"publisher","first-page":"3970","DOI":"10.3390\/ma13183970","volume":"13","author":"SM Park","year":"2020","unstructured":"Park SM, Park JM, Kim SK, Heo SJ, Koak JY. Flexural strength of 3d-printing resin materials for provisional fixed dental prostheses. Materials. 2020;13:3970.","journal-title":"Materials"},{"key":"5679_CR16","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1007\/s00784-019-02952-7","volume":"24","author":"M Reymus","year":"2020","unstructured":"Reymus M, Fabritius R, Ke\u00dfler A, Hickel R, Edelhoff D, Stawarczyk B. Fracture load of 3D-printed fixed dental prostheses compared with milled and conventionally fabricated ones: the impact of resin material, build direction, post-curing, and artificial aging-an in vitro study. Clin Oral Investig. 2020;24:701\u201310.","journal-title":"Clin Oral Investig"},{"issue":"2","key":"5679_CR17","doi-asserted-by":"publisher","first-page":"259","DOI":"10.3390\/ma14020259","volume":"14","author":"J Nold","year":"2021","unstructured":"Nold J, Wesemann C, Rieg L, Binder L, Witkowski S, Spies BC, et al. Does printing orientation matter? In-Vitro fracture strength of Temporary fixed Dental prostheses after a 1-Year Simulation in the Artificial Mouth. Materials. 2021;14(2):259.","journal-title":"Materials"},{"key":"5679_CR18","doi-asserted-by":"publisher","first-page":"82","DOI":"10.5005\/jp-journals-10019-1313","volume":"11","author":"R Kumar","year":"2021","unstructured":"Kumar R, Suganna M, Ahmed R, Rajan MK. An in vitro evaluation of 3D-printed provisional restoration marginal adaptation on diverse finish lines. IJOPRD. 2021;11:82\u20137.","journal-title":"IJOPRD"},{"key":"5679_CR19","doi-asserted-by":"publisher","first-page":"A1","DOI":"10.1016\/j.matpr.2022.12.149","volume":"62","author":"A Thakare","year":"2022","unstructured":"Thakare A, Ramesh S, Patil V, Meenakshi S, Ramu R, Byakodi R. Comparative evaluation of internal and marginal fit of interim crowns fabricated by CAD\/CAM milling and two different 3D printing systems - an in vitro study. Mater Today Proc. 2022;62:A1\u20139.","journal-title":"Mater Today Proc"},{"key":"5679_CR20","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1016\/j.jpor.2017.09.002","volume":"62","author":"N Alharbi","year":"2018","unstructured":"Alharbi N, Alharbi S, Cuijpers VMJI, Osman RB, Wismeijer D. Three-dimensional evaluation of marginal and internal fit of 3D-printed interim restorations fabricated on different finish line designs. J Prosthodont Res. 2018;62:218\u201326.","journal-title":"J Prosthodont Res"},{"key":"5679_CR21","doi-asserted-by":"publisher","first-page":"1404","DOI":"10.1002\/cre2.637","volume":"8","author":"M Falahchai","year":"2022","unstructured":"Falahchai M, Rahimabadi S, Khabazkar G, Babaee Hemmati Y, Neshandar Asli H. Marginal and internal fit and fracture resistance of three-unit provisional restorations fabricated by additive, subtractive, and conventional methods. Clin Exp Dent Res. 2022;8:1404\u201312.","journal-title":"Clin Exp Dent Res"},{"issue":"5","key":"5679_CR22","first-page":"566","volume":"24","author":"T Angwarawong","year":"2020","unstructured":"Angwarawong T, Reeponmaha T, Angwaravong O. Influence of thermomechanical aging on marginal gap of CAD-CAM and conventional interim restorations. J Prosthet Dent. 2020;24(5):566.e1-566.e6.","journal-title":"J Prosthet Dent"},{"key":"5679_CR23","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1016\/j.prosdent.2016.03.012","volume":"116","author":"JY Park","year":"2016","unstructured":"Park JY, Jeong il Do, Lee JJ, Bae SY, Kim JH, Kim WC. In vitro assessment of the marginal and internal fits of interim implant restorations fabricated with different methods. J Prosthet Dent. 2016;116:536\u201342.","journal-title":"J Prosthet Dent"},{"key":"5679_CR24","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1111\/jopr.13524","volume":"32","author":"J Legaz","year":"2023","unstructured":"Legaz J, Sailer I, Mojon P, Lee H, Karasan D. Mechanical properties of additively manufactured and milled interim 3-unit fixed dental prostheses. J Prosthodont. 2023;32:234\u201343.","journal-title":"J Prosthodont"},{"key":"5679_CR25","doi-asserted-by":"publisher","first-page":"175","DOI":"10.3758\/BF03193146","volume":"39","author":"F Faul","year":"2007","unstructured":"Faul F, Erdfelder E, Lang AG, Buchner A. G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39:175\u201391.","journal-title":"Behav Res Methods"},{"issue":"8","key":"5679_CR26","first-page":"953","volume":"100","author":"I Krejci","year":"1990","unstructured":"Krejci I, Reich T, Lutz F, Albertoni M. [An in vitro test procedure for evaluating dental restoration systems. 1. A computer-controlled mastication simulator]. Schweiz Monatsschr Zahnmed. 1990;100(8):953\u201360.","journal-title":"Schweiz Monatsschr Zahnmed"},{"key":"5679_CR27","unstructured":"IBM Corp. Released 2021. IBM SPSS statistics for Windows, Version 28.0. Armonk, NY: IBM Corp."},{"key":"5679_CR28","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1038\/sj.bdj.4802708","volume":"131","author":"JW McLean","year":"1971","unstructured":"McLean JW, Von F. The estimation of cement film thickness by an in vivo technique. Br Dent J. 1971;131:107\u201311.","journal-title":"Br Dent J"},{"key":"5679_CR29","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1111\/jopr.12006","volume":"22","author":"NA Nawafleh","year":"2013","unstructured":"Nawafleh NA, Mack F, Evans J, Mackay J, Hatamleh MM. Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: a literature review. J Prosthodont. 2013;22:419\u201328.","journal-title":"J Prosthodont"},{"key":"5679_CR30","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1016\/0022-3913(89)90170-4","volume":"62","author":"JR Holmes","year":"1989","unstructured":"Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent. 1989;62:405\u20138.","journal-title":"J Prosthet Dent"},{"key":"5679_CR31","doi-asserted-by":"publisher","first-page":"957","DOI":"10.4012\/dmj.2017-315","volume":"37","author":"AO Abdullah","year":"2018","unstructured":"Abdullah AO, Pollington S, Liu Y. Comparison between direct chairside and digitally fabricated temporary crowns. Dent Mater J. 2018;37:957\u201363.","journal-title":"Dent Mater J"},{"key":"5679_CR32","doi-asserted-by":"publisher","first-page":"119","DOI":"10.5005\/jp-journals-10019-1326","volume":"11","author":"LB Kanchan","year":"2021","unstructured":"Kanchan LB, Majage B, Hoskhande A, George M. Effect of thermal cycling on the marginal fit of provisional restorations fabricated using three different materials: an in vitro study. IJOPRD. 2021;11:119\u201324.","journal-title":"IJOPRD"},{"key":"5679_CR33","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1016\/j.prosdent.2016.10.030","volume":"118","author":"HN Mai","year":"2017","unstructured":"Mai HN, Lee KB, Lee DH. Fit of interim crowns fabricated using photopolymer-jetting 3D printing. J Prosthet Dent. 2017;118:208\u201315.","journal-title":"J Prosthet Dent"},{"key":"5679_CR34","doi-asserted-by":"publisher","first-page":"8964","DOI":"10.3390\/app11198964","volume":"11","author":"N Aldahian","year":"2021","unstructured":"Aldahian N, Khan R, Mustafa M, Vohra F, Alrahlah A. Influence of conventional, CAD-CAM, and 3D printing fabrication techniques on the marginal integrity and surface roughness and wear of interim crowns. Appl Sci. 2021;11:8964.","journal-title":"Appl Sci"},{"key":"5679_CR35","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1016\/S0109-5641(03)00101-5","volume":"20","author":"SH Kim","year":"2004","unstructured":"Kim SH, Watts DC. Polymerization shrinkage-strain kinetics of temporary crown and bridge materials. Dent Mater. 2004;20:88\u201395.","journal-title":"Dent Mater"},{"key":"5679_CR36","doi-asserted-by":"crossref","unstructured":"Kim J, Lee DH. Influence of the postcuring process on dimensional accuracy and seating of 3D-printed polymeric fixed prostheses. Biomed Res Int. 2020;2020:2150182.","DOI":"10.1155\/2020\/2150182"},{"key":"5679_CR37","doi-asserted-by":"publisher","first-page":"503","DOI":"10.11607\/ijp.4835","volume":"29","author":"N Alharbi","year":"2016","unstructured":"Alharbi N, Osman R, Wismeijer D. Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology. Int J Prosthodont. 2016;29:503\u201310.","journal-title":"Int J Prosthodont"},{"key":"5679_CR38","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/j.prosdent.2020.04.028","volume":"126","author":"BY Yu","year":"2021","unstructured":"Yu BY, Son KB, Da, Lee KB. Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing. J Prosthet Dent. 2021;126:231\u20137.","journal-title":"J Prosthet Dent"},{"key":"5679_CR39","doi-asserted-by":"publisher","first-page":"182","DOI":"10.11607\/ijp.5117","volume":"30","author":"R Osman","year":"2017","unstructured":"Osman R, Alharbi N, Wismeijer D. Build angle: does it influence the accuracy of 3D-printed dental restorations using digital light-processing technology? Int J Prosthodont. 2017;30:182\u20138.","journal-title":"Int J Prosthodont"},{"key":"5679_CR40","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12903-024-03851-4","volume":"24","author":"E Farag","year":"2024","unstructured":"Farag E, Sabet A, Ebeid K, El Sergany O. Build angle effect on 3D-printed dental crowns marginal fit using digital light-processing and stereo-lithography technology: an in vitro study. BMC Oral Health. 2024;24:1\u20136.","journal-title":"BMC Oral Health"},{"key":"5679_CR41","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1016\/j.dental.2017.10.003","volume":"34","author":"A Tahayeri","year":"2018","unstructured":"Tahayeri A, Morgan MC, Fugolin AP, Bompolaki D, Athirasala A, Pfeifer CS, et al. 3D printed versus conventionally cured provisional crown and bridge dental materials. Dent Mater. 2018;34:192\u2013200.","journal-title":"Dent Mater"},{"key":"5679_CR42","doi-asserted-by":"publisher","first-page":"250","DOI":"10.4047\/jap.2022.14.4.250","volume":"14","author":"MS Yang","year":"2022","unstructured":"Yang MS, Kim SK, Heo SJ, Koak JY, Park JM. Investigation of the marginal fit of a 3D-printed three-unit resin prosthesis with different build orientations and layer thicknesses. J Adv Prosthodont. 2022;14:250\u201361.","journal-title":"J Adv Prosthodont"},{"key":"5679_CR43","doi-asserted-by":"crossref","unstructured":"Park GS, Kim SK, Heo SJ, Koak JY, Seo DG. Effects of printing parameters on the fit of implant-supported 3D printing resin prosthetics. Materials. 2019;12.","DOI":"10.3390\/ma12162533"},{"key":"5679_CR44","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1111\/jopr.13454","volume":"31","author":"D Karasan","year":"2022","unstructured":"Karasan D, Legaz J, Boitelle P, Mojon P, Fehmer V, Sailer I. Accuracy of additively manufactured and milled interim 3-unit fixed dental prostheses. J Prosthodont. 2022;31:58\u201369.","journal-title":"J Prosthodont"},{"key":"5679_CR45","doi-asserted-by":"publisher","first-page":"e324","DOI":"10.1016\/j.dental.2018.09.011","volume":"34","author":"A Unkovskiy","year":"2018","unstructured":"Unkovskiy A, Bui PHB, Schille C, Geis-Gerstorfer J, Huettig F, Spintzyk S. Objects build orientation, positioning, and curing influence dimensional accuracy and flexural properties of stereolithographically printed resin. Dent Mater. 2018;34:e324\u201333.","journal-title":"Dent Mater"},{"key":"5679_CR46","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1007\/s00784-011-0670-4","volume":"16","author":"B Stawarczyk","year":"2012","unstructured":"Stawarczyk B, Ender A, Trottmann A, \u00d6zcan M, Fischer J, H\u00e4mmerle CHF. Load-bearing capacity of CAD\/CAM milled polymeric three-unit fixed dental prostheses: effect of aging regimens. Clin Oral Investig. 2012;16:1669\u201377.","journal-title":"Clin Oral Investig"},{"issue":"2","key":"5679_CR47","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1007\/s00784-019-02952-7","volume":"24","author":"M Reymus","year":"2020","unstructured":"Reymus M, Fabritius R, Ke\u00dfler A, Hickel R, Edelhoff D, Stawarczyk B. Fracture load of 3D-printed fixed dental prostheses compared with milled and conventionally fabricated ones: the impact of resin material, build direction, post-curing, and artificial aging-an in vitro study. Clin Oral Investig. 2020;24(2):701\u201310.","journal-title":"Clin Oral Investig"},{"key":"5679_CR48","doi-asserted-by":"publisher","first-page":"5987","DOI":"10.1007\/s00784-021-03905-9","volume":"25","author":"J Mayer","year":"2021","unstructured":"Mayer J, Stawarczyk B, Vogt K, Hickel R, Edelhoff D, Reymus M. Influence of cleaning methods after 3D printing on two-body wear and fracture load of resin-based temporary crown and bridge material. Clin Oral Investig. 2021;25:5987\u201396.","journal-title":"Clin Oral Investig"},{"key":"5679_CR49","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1016\/j.jpor.2018.03.001","volume":"62","author":"K Debye","year":"2018","unstructured":"Debye K, Tuna T, Bishti S, Wolfart S. Influence of additional reinforcement of fixed long-term temporary restorations on fracture load. J Prosthodont Res. 2018;62:416\u201321.","journal-title":"J Prosthodont Res"},{"key":"5679_CR50","doi-asserted-by":"publisher","first-page":"104155","DOI":"10.1016\/j.jdent.2022.104155","volume":"124","author":"AA Diken Turksayar","year":"2022","unstructured":"Diken Turksayar AA, Donmez MB, Olcay EO, Demirel M, Demir E. Effect of printing orientation on the fracture strength of additively manufactured 3-unit interim fixed dental prostheses after aging. J Dent. 2022;124:104155.","journal-title":"J Dent"},{"key":"5679_CR51","unstructured":"Reymus M, L\u00fcmkemann N, Stawarczyk B. 3D-printed material for temporary restorations: impact of print layer thickness and post-curing method on degree of conversion. Int J Comput Dent. 2019;22(3):231\u20137."},{"key":"5679_CR52","doi-asserted-by":"publisher","first-page":"1352","DOI":"10.1016\/j.dental.2008.02.019","volume":"24","author":"SD Heintze","year":"2008","unstructured":"Heintze SD, Cavalleri A, Zellweger G, B\u00fcchler A, Zappini G. Fracture frequency of all-ceramic crowns during dynamic loading in a chewing simulator using different loading and luting protocols. Dent Mater. 2008;24:1352\u201361.","journal-title":"Dent Mater"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05679-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-05679-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05679-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T06:41:49Z","timestamp":1741329709000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-05679-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,7]]},"references-count":52,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5679"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-05679-y","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,7]]},"assertion":[{"value":"4 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Prior to the commencement of the study, the Research Ethics Committee, Faculty of Dentistry, Alexandria University approved the study (#0130-04\/2020). The methods were performed in accordance with the Declaration of Helsinki and the ethical guidelines adopted by the Research Ethics Committee of the Faculty of Dentistry, Alexandria University. No human participants were involved in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"354"}}