{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T13:21:26Z","timestamp":1768483286721,"version":"3.49.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,3]],"date-time":"2025-04-03T00:00:00Z","timestamp":1743638400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,3]],"date-time":"2025-04-03T00:00:00Z","timestamp":1743638400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"the Nature Science Foundation of Zhejiang Province","award":["No. TGY24H140010"],"award-info":[{"award-number":["No. TGY24H140010"]}]},{"name":"the University-Industry Cooperation and Collaborative Education Project of the Ministry of Education in 2024","award":["No. 240900627102436"],"award-info":[{"award-number":["No. 240900627102436"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>The chief aim of this study was to confirm the accuracy and repeatability of digital indirect bonding (IDB) by simulating customized clinical orthodontic procedures with personalized typodonts from the perspective of orthodontic outcomes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Five personalized typodonts were produced with 3D-printing technology to mimic straight-wire orthodontic procedures. The digital IDB was employed to position the customized brackets. After treatment, the PAR index, the ABO-OGS index and the occlusal contact area were analyzed. The matching degree between the target position and the posttreatment position on typodonts was assessed with Geomagic Control X.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The mean arch discrepancy between the personalized typodonts and the initial intraoral scan model was 0.15\u00a0mm\u2009\u00b1\u20090.01\u00a0mm in the maxilla and 0.20\u00a0mm\u2009\u00b1\u20090.01\u00a0mm in the mandible. Following customized orthodontic therapy, the PAR Index decreased from 29 to 1, the ABO-OGS Index was 13.8\u2009\u00b1\u20090.84, and the occlusal contact area increased 4.04mm<jats:sup>2<\/jats:sup>\u2009\u00b1\u20091.14mm<jats:sup>2<\/jats:sup>, with the bilateral occlusal contact area becoming equally distributed. The mean arch discrepancy between the target position and the actual posttreatment positions was 0.15\u00a0mm\u2009\u00b1\u20090.01\u00a0mm in the maxilla and 0.16\u00a0mm\u2009\u00b1\u20090.01\u00a0mm in the mandible.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Digital IDB is conducive to locating the brackets in the target position to precisely achieve the ideal therapeutic outcome of customized orthodontic systems on the personalized typodont. The customized bracket design and the digital IDB can lead orthodontics in a more accurate, visual, and predictable direction.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s12903-025-05777-x","type":"journal-article","created":{"date-parts":[[2025,4,4]],"date-time":"2025-04-04T09:14:07Z","timestamp":1743758047000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Accuracy of digital indirect bonding technology for customized orthodontic brackets based on personalized typodonts"],"prefix":"10.1186","volume":"25","author":[{"given":"Yuqian","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Linyi","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Menghan","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yiyang","family":"Du","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuyang","family":"Gan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Biyao","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianying","family":"Feng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,4,3]]},"reference":[{"issue":"1","key":"5777_CR1","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1016\/j.jds.2020.05.022","volume":"16","author":"SB Khanagar","year":"2021","unstructured":"Khanagar SB, Al-Ehaideb A, Vishwanathaiah S, et al. Scope and performance of artificial intelligence technology in orthodontic diagnosis, treatment planning, and clinical decision-making - A systematic review. J Dent Sci. 2021;16(1):482\u201392.","journal-title":"J Dent Sci"},{"issue":"6","key":"5777_CR2","doi-asserted-by":"crossref","first-page":"e21spe6","DOI":"10.1590\/2177-6709.26.6.e21spe6","volume":"26","author":"TMA Cunha","year":"2021","unstructured":"Cunha TMA, Barbosa IS, Palma KK. Orthodontic digital workflow: devices and clinical applications. Dent Press J Orthod. 2021;26(6):e21spe6.","journal-title":"Dent Press J Orthod"},{"issue":"1","key":"5777_CR3","first-page":"96","volume":"31","author":"F Liu","year":"2022","unstructured":"Liu F, Liu L, Wang YH. Evaluation of the effect of insignia system in customized orthodontic treatment. Shanghai Kou Qiang Yi Xue. 2022;31(1):96\u20139.","journal-title":"Shanghai Kou Qiang Yi Xue"},{"issue":"11","key":"5777_CR4","doi-asserted-by":"crossref","first-page":"1058","DOI":"10.1016\/j.dental.2023.09.011","volume":"39","author":"A Schw\u00e4rzler","year":"2023","unstructured":"Schw\u00e4rzler A, Nemec M, Lettner S, Rank C, Schedle A, Jonke E. 3D printed indirect bonding trays: transfer accuracy of hard versus soft resin material in a prospective, randomized, single-blinded clinical study. Dent Mater. 2023;39(11):1058\u201365.","journal-title":"Dent Mater"},{"issue":"2","key":"5777_CR5","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1093\/ejo\/cjaa045","volume":"43","author":"I Czolgosz","year":"2021","unstructured":"Czolgosz I, Cattaneo PM, Cornelis MA. Computer-aided indirect bonding versus traditional direct bonding of orthodontic brackets: bonding time, immediate bonding failures, and cost-minimization. A randomized controlled trial. Eur J Orthod. 2021;43(2):144\u201351.","journal-title":"Eur J Orthod"},{"issue":"1","key":"5777_CR6","doi-asserted-by":"crossref","first-page":"92","DOI":"10.2319\/030919-176.1","volume":"90","author":"MEA Duarte","year":"2020","unstructured":"Duarte MEA, Gribel BF, Spitz A, Artese F, Miguel JAM. Reproducibility of digital indirect bonding technique using Three-dimensional (3d) models and 3d-printed transfer trays. Angle Orthod. 2020;90(1):92\u20139.","journal-title":"Angle Orthod"},{"issue":"1","key":"5777_CR7","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1111\/jerd.12702","volume":"33","author":"D Grauer","year":"2021","unstructured":"Grauer D. Quality in orthodontics: the role of customized appliances. J Esthet Restor Dent. 2021;33(1):253\u20138.","journal-title":"J Esthet Restor Dent"},{"issue":"2","key":"5777_CR8","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/j.ajodo.2021.02.026","volume":"162","author":"XT Wang","year":"2022","unstructured":"Wang XT, Xia LG, Li JY, et al. Accuracy of dental arch form in customized fixed labial orthodontic appliances. Am J Orthod Dentofac Orthop. 2022;162(2):173\u201381.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"1","key":"5777_CR9","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00056-015-0001-5","volume":"77","author":"R M\u00fcller-Hartwich","year":"2016","unstructured":"M\u00fcller-Hartwich R, Jost-Brinkmann PG, Schubert K. Precision of implementing virtual setups for orthodontic treatment using CAD\/CAM-fabricated custom archwires. J Orofac Orthop. 2016;77(1):1\u20138.","journal-title":"J Orofac Orthop"},{"issue":"3","key":"5777_CR10","doi-asserted-by":"crossref","first-page":"372","DOI":"10.2319\/073021-596.1","volume":"92","author":"PC Bachour","year":"2022","unstructured":"Bachour PC, Klabunde R, Gr\u00fcnheid T. Transfer accuracy of 3D-printed trays for indirect bonding of orthodontic brackets: A clinical study. Angle Orthod. 2022;92(3):372\u20139.","journal-title":"Angle Orthod"},{"issue":"1","key":"5777_CR11","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1186\/s40510-022-00426-3","volume":"23","author":"R Aboujaoude","year":"2022","unstructured":"Aboujaoude R, Kmeid R, Gebrael C, Amm E. Comparison of the accuracy of bracket positioning between direct and digital indirect bonding techniques in the maxillary arch: a three-dimensional study. Prog Orthod. 2022;23(1):31.","journal-title":"Prog Orthod"},{"key":"5777_CR12","first-page":"1","volume":"2024","author":"D Al-Ubaydi ASh, Al-Groosh","year":"2024","unstructured":"Al-Ubaydi ASh, Al-Groosh D. Do the various indirect bonding techniques provide the same accuracy for orthodontic bracket placement?? (Randomized clinical Trial). Int J Dent. 2024;2024:1\u201317.","journal-title":"Int J Dent"},{"issue":"1","key":"5777_CR13","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1186\/s12903-022-02526-2","volume":"22","author":"XL Liu","year":"2022","unstructured":"Liu XL, Cheng YX, Qin W, et al. Effects of upper-molar distalization using clear aligners in combination with class II elastics: a three-dimensional finite element analysis. BMC Oral Health. 2022;22(1):546.","journal-title":"BMC Oral Health"},{"issue":"9","key":"5777_CR14","doi-asserted-by":"crossref","first-page":"3824","DOI":"10.3390\/app11093824","volume":"11","author":"IA Sioustis","year":"2021","unstructured":"Sioustis IA, Axinte M, Prelipceanu M, et al. Finite element analysis of mandibular anterior teeth with healthy, but reduced periodontium. Appl Sci. 2021;11(9):3824.","journal-title":"Appl Sci"},{"issue":"Suppl 1","key":"5777_CR15","doi-asserted-by":"crossref","first-page":"S143","DOI":"10.4103\/jpbs.jpbs_712_21","volume":"14","author":"AA Kumar","year":"2022","unstructured":"Kumar AA, Sekar S, Kumar SS, Divakar G, Vijayarangam K, Arulselvi S. Computation and collation of torque expression in 0.018 inch and 0.022 inch preadjusted bracket slots on passive insertion of Full-Size Archwire: A finite element study. J Pharm Bioallied Sci. 2022;14(Suppl 1):S143\u20137.","journal-title":"J Pharm Bioallied Sci"},{"issue":"3","key":"5777_CR16","doi-asserted-by":"crossref","first-page":"31","DOI":"10.3390\/dj9030031","volume":"9","author":"TM Elshazly","year":"2021","unstructured":"Elshazly TM, Keilig L, Alkabani Y, et al. Primary evaluation of shape recovery of orthodontic aligners fabricated from shape memory polymer (A typodont Study). Dent J. 2021;9(3):31.","journal-title":"Dent J"},{"key":"5777_CR17","doi-asserted-by":"crossref","first-page":"794536","DOI":"10.3389\/fmats.2021.794536","volume":"8","author":"TM Elshazly","year":"2022","unstructured":"Elshazly TM, Keilig L, Alkabani Y, et al. Potential application of 4D technology in fabrication of orthodontic aligners. Front Mater. 2022;8:794536.","journal-title":"Front Mater"},{"issue":"2","key":"5777_CR18","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1111\/ocr.12611","volume":"26","author":"A Kang","year":"2023","unstructured":"Kang A, Firth FA, Antoun J, Mei L, Ali A, Farella M. Three-dimensional digital assessment of typodont activations. Orthod Craniofac Res. 2023;26(2):285\u201396.","journal-title":"Orthod Craniofac Res"},{"issue":"1","key":"5777_CR19","doi-asserted-by":"crossref","first-page":"26","DOI":"10.4041\/kjod.2020.50.1.26","volume":"50","author":"BQ Hung","year":"2020","unstructured":"Hung BQ, Hong M, Yu W, Kyung HM. Comparison of inclination and vertical changes between single-wire and double-wire Retraction techniques in lingual orthodontics. Korean J Orthod. 2020;50(1):26.","journal-title":"Korean J Orthod"},{"issue":"3","key":"5777_CR20","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1093\/ejo\/21.3.213","volume":"21","author":"PM Clifford","year":"1999","unstructured":"Clifford PM, Orr JF, Burden DJ. The effects of increasing the reverse curve of Spee in a lower archwire examined using a dynamic photo-elastic gelatine model. Eur J Orthod. 1999;21(3):213\u201322.","journal-title":"Eur J Orthod"},{"issue":"3","key":"5777_CR21","doi-asserted-by":"crossref","first-page":"158","DOI":"10.4041\/kjod.2017.47.3.158","volume":"47","author":"JY Kim","year":"2017","unstructured":"Kim JY, Yu WJ, Koteswaracc PNK, Kyung HM. Effects of bracket slot size during en-masse Retraction of the six maxillary anterior teeth using an induction-heating typodont simulation system. Korean J Orthod. 2017;47(3):158.","journal-title":"Korean J Orthod"},{"key":"5777_CR22","unstructured":"Kuang BY. The Practical and New Method for the Fusion of 3D CBCT Reconstructive Model and Laser-Scanner STL Dental Model[D]. Shandong University, 2017."},{"issue":"1","key":"5777_CR23","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1186\/s12903-024-04088-x","volume":"24","author":"XR Han","year":"2024","unstructured":"Han XR, Wei DH, Jiang X, Di P, Yi C, Lin Y. Digital registration versus cone-beam computed tomography for evaluating implant position: a prospective cohort study. BMC Oral Health. 2024;24(1):304.","journal-title":"BMC Oral Health"},{"key":"5777_CR24","unstructured":"Patano A, Inchingolo AD, Malcangi G, et al. Direct and indirect bonding techniques in orthodontics: a systematic review. Eur Rev Med Pharmacol Sci. 2023;27(17):8039\u201354."},{"issue":"Suppl 2","key":"5777_CR25","doi-asserted-by":"crossref","first-page":"S1188","DOI":"10.4103\/jpbs.jpbs_167_23","volume":"15","author":"KKK Fafat","year":"2023","unstructured":"Fafat KKK, Jain D, Pandit SK, Kharbanda R, Trivedy P, Gupta E. Computer-aided indirect bonding versus traditional direct bonding of orthodontic brackets: bonding time, immediate bonding failures, and cost-minimization. A randomized controlled trial. J Pharm Bioallied Sci. 2023;15(Suppl 2):S1188\u201391.","journal-title":"J Pharm Bioallied Sci"},{"issue":"4","key":"5777_CR26","doi-asserted-by":"crossref","first-page":"986","DOI":"10.3390\/ma13040986","volume":"13","author":"A Nawrocka","year":"2020","unstructured":"Nawrocka A, Lukomska-Szymanska M. The indirect bonding technique in Orthodontics\u2014A narrative literature review. Materials. 2020;13(4):986.","journal-title":"Materials"},{"issue":"1","key":"5777_CR27","doi-asserted-by":"crossref","first-page":"23","DOI":"10.3390\/biomimetics7010023","volume":"7","author":"I Francisco","year":"2022","unstructured":"Francisco I, Ribeiro MP, Marques F, et al. Application of Three-Dimensional digital technology in orthodontics: the state of the Art. Biomimetics. 2022;7(1):23.","journal-title":"Biomimetics"},{"issue":"1","key":"5777_CR28","doi-asserted-by":"crossref","first-page":"67","DOI":"10.2319\/013120-70.1","volume":"91","author":"Y Niu","year":"2021","unstructured":"Niu Y, Zeng Y, Zhang Z, Xu W, Xiao L. Comparison of the transfer accuracy of two digital indirect bonding trays for labial bracket bonding. Angle Orthod. 2021;91(1):67\u201373.","journal-title":"Angle Orthod"},{"issue":"6","key":"5777_CR29","doi-asserted-by":"crossref","first-page":"728","DOI":"10.2319\/122021-925.1","volume":"92","author":"EC Hofmann","year":"2022","unstructured":"Hofmann EC, S\u00fcpple J, Von Glasenapp J, Jost-Brinkmann PG, Koch PJ. Indirect bonding: an in-vitro comparison of a polyjet printed versus a conventional silicone transfer tray. Angle Orthod. 2022;92(6):728\u201337.","journal-title":"Angle Orthod"},{"issue":"1","key":"5777_CR30","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/j.ajodo.2005.10.005","volume":"129","author":"F Ciuffolo","year":"2006","unstructured":"Ciuffolo F, Epifania E, Duranti G, et al. Rapid prototyping: A new method of Preparing trays for indirect bonding. Am J Orthod Dentofac Orthop. 2006;129(1):75\u20137.","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"5777_CR31","doi-asserted-by":"crossref","unstructured":"Amornvit P, Rokaya D, Sanohkan S. Comparison of Accuracy of Current Ten Intraoral Scanners. Grassia V, ed. BioMed Res Int. 2021;2021(1):2673040.","DOI":"10.1155\/2021\/2673040"},{"issue":"5","key":"5777_CR32","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1093\/ejo\/cjm037","volume":"29","author":"D Armstrong","year":"2007","unstructured":"Armstrong D, Shen G, Petocz P, Darendeliler MA. A comparison of accuracy in bracket positioning between two techniques\u2013localizing the centre of the clinical crown and measuring the distance from the incisal edge. Eur J Orthod. 2007;29(5):430\u20136.","journal-title":"Eur J Orthod"},{"issue":"4","key":"5777_CR33","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1016\/j.ortho.2020.07.002","volume":"18","author":"M Mujagic","year":"2020","unstructured":"Mujagic M, Pandis N, Fleming PS, Katsaros C. The herbst appliance combined with a completely customized lingual appliance: A retrospective cohort study of clinical outcomes using the American board of orthodontics objective grading system. Int Orthod. 2020;18(4):732\u20138.","journal-title":"Int Orthod"},{"issue":"11","key":"5777_CR34","doi-asserted-by":"crossref","first-page":"3889","DOI":"10.1007\/s00784-020-03256-x","volume":"24","author":"T Pottier","year":"2020","unstructured":"Pottier T, Brient A, Turpin YL, et al. Accuracy evaluation of bracket repositioning by indirect bonding: hard acrylic CAD\/CAM versus soft one-layer silicone trays, an in vitro study. Clin Oral Investig. 2020;24(11):3889\u201397.","journal-title":"Clin Oral Investig"},{"issue":"3","key":"5777_CR35","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.ajodo.2023.09.010","volume":"165","author":"NV Anh","year":"2024","unstructured":"Anh NV, Duc NM, Tra NT, Ngoc VTN, Son TM. Lingual bracket transfer accuracy of double vacuum-formed indirect bonding tray using 3D-printed model: an in vivo study. Am J Orthod Dentofac Orthop. 2024;165(3):294\u2013302.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"2","key":"5777_CR36","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.ajodo.2019.03.022","volume":"157","author":"C Xue","year":"2020","unstructured":"Xue C, Xu H, Guo Y, et al. Accurate bracket placement using a computer-aided design and computer- aided manufacturing\u2013guided bonding device: an in vivo study. Am J Orthod Dentofac Orthop. 2020;157(2):269\u201377.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"1","key":"5777_CR37","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.ajodo.2021.04.025","volume":"162","author":"SH Yoo","year":"2022","unstructured":"Yoo SH, Choi SH, Kim KM, et al. Accuracy of 3-dimensional printed bracket transfer tray using an in-office indirect bonding system. Am J Orthod Dentofac Orthop. 2022;162(1):93\u2013102.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"1","key":"5777_CR38","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.ajodo.2021.08.023","volume":"163","author":"M Palone","year":"2023","unstructured":"Palone M, Koch PJ, Jost-Brinkmann PG, et al. Accuracy of indirect bracket placement with medium-soft, transparent, broad-coverage transfer trays fabricated using computer-aided design and manufacturing: an in-vivo study. Am J Orthod Dentofac Orthop. 2023;163(1):33\u201346.","journal-title":"Am J Orthod Dentofac Orthop"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05777-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-05777-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05777-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T02:22:16Z","timestamp":1744165336000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-05777-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,3]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5777"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-05777-x","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,3]]},"assertion":[{"value":"24 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The research was approved by the Medical Ethics Committee of the Hospital of Stomatology, Zhejiang Chinese Medical University, Hangzhou 310053, China; (File Number: ZCMUHSIEB-2023061304). Informed consent was obtained from the patient. All methods were performed in accordance with the relevant guidelines and regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"478"}}