{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T02:28:20Z","timestamp":1788402500920,"version":"build-2803163510"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,11]],"date-time":"2025-04-11T00:00:00Z","timestamp":1744329600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,11]],"date-time":"2025-04-11T00:00:00Z","timestamp":1744329600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009827","name":"Alexandria University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100009827","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>With the advent of clear aligner therapy and their increasing popularity across the orthodontic field, many software packages have been introduced that implement the concept of virtual setups and consequently, the fabrication of in-house aligners. The objective of the present study was to evaluate and compare the differences in the resultant tooth movements when the same tooth movement values of virtual setups are implemented into four different software packages for clear aligner treatment, in patients with various degrees of dental crowding.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Forty-four stereolithography (STL) files of adult Invisalign<jats:sup>\u00ae<\/jats:sup>-treated patients were included in this in silico study and were divided according to the amount of existent dental crowding into 2 groups; Moderate (2.5\u20135\u00a0mm), and Severe (&gt;\u20095\u00a0mm). Initial STL files were imported into the other three tested software programs (Ortho Analyzer<jats:sup>\u00ae<\/jats:sup>, Maestro 3D Ortho Studio<jats:sup>\u00ae<\/jats:sup>\n              <jats:sup>,<\/jats:sup> Blue Sky Plan<jats:sup>\u00ae<\/jats:sup>), and the teeth were moved to replicate those performed in the virtual setup from ClinCheck<jats:sup>\u00ae<\/jats:sup> Pro. The final outcome was then exported from the four software packages, with ClinCheck<jats:sup>\u00ae<\/jats:sup> Pro STL files used as references, whereas those from the remaining software considered targets. Superimpositions were performed afterwards using Medit Link software between reference and target STL files to calculate the overall deviation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Statistically significant deviation values were recorded between ClinCheck-Ortho Analyzer, and those recorded with both ClinCheck-Maestro and ClinCheck-Blue Sky in the moderate crowding group for the upper and lower models (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05). However, the differences in ClinCheck-Maestro and ClinCheck-Blue Sky deviation values were not statistically significant (<jats:italic>p<\/jats:italic>\u2009&gt;\u20090.05). In the severe crowding group, statistically significant variances were documented among the investigated software programs, in contrast to the benchmark (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05). As per the reported outcomes, the highest deviation was attributed to ClinCheck-Ortho Analyzer, followed by ClinCheck-Blue Sky and ClinCheck-Maestro (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>With the same tooth movement values provided, the four examined programs produced diverse final virtual tooth setups, with greater variance in cases of severe dental crowding. This deviation arises since every software operates using a distinct algorithm, with a different segmentation method and rotation center for the moving teeth.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s12903-025-05841-6","type":"journal-article","created":{"date-parts":[[2025,4,11]],"date-time":"2025-04-11T16:55:38Z","timestamp":1744390538000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Comparison of three-dimensional tooth movements in virtual setups using different software packages for clear aligner therapy"],"prefix":"10.1186","volume":"25","author":[{"given":"Farah Y.","family":"Eid","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Waddah","family":"Sabouni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abbas","family":"Zaher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mostafa A.","family":"Tageldin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dina","family":"Elfouly","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,4,11]]},"reference":[{"key":"5841_CR1","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/0096-6347(46)90053-1","volume":"32","author":"HD Kesling","year":"1946","unstructured":"Kesling HD. Coordinating the predetermined pattern and tooth positioner with conventional treatment. Am J Orthod Oral Surg. 1946;32:285\u201393.","journal-title":"Am J Orthod Oral Surg"},{"key":"5841_CR2","first-page":"0","volume":"5","author":"S Logozzo","year":"2011","unstructured":"Logozzo S, Franceschini G, Kilpela A, Governi L, Caponi M, Blois L. A comparative analysis of intraoral 3D digital scanners for restorative dentistry. Internet J Med Technol. 2011;5:0.","journal-title":"Internet J Med Technol"},{"key":"5841_CR3","first-page":"337","volume":"48","author":"ND Kravitz","year":"2014","unstructured":"Kravitz ND, Groth C, Jones PE, Graham JW, Redmond WR. Intraoral digital scanners. J Clin Orthod. 2014;48:337\u201347.","journal-title":"J Clin Orthod"},{"key":"5841_CR4","doi-asserted-by":"crossref","unstructured":"Ojima K, Kau CH. A perspective in accelerated orthodontics with aligner treatment. Semin Orthod. 2017; 76\u201382.","DOI":"10.1053\/j.sodo.2016.10.002"},{"key":"5841_CR5","doi-asserted-by":"publisher","first-page":"140","DOI":"10.4041\/kjod.2019.49.3.140","volume":"49","author":"L Galan-Lopez","year":"2019","unstructured":"Galan-Lopez L, Barcia-Gonzalez J, Plasencia E. A systematic review of the accuracy and efficiency of dental movements with Invisalign\u00ae. Korean J Orthod. 2019;49:140\u20139.","journal-title":"Korean J Orthod"},{"key":"5841_CR6","first-page":"203","volume":"34","author":"RL Boyd","year":"2000","unstructured":"Boyd RL, Miller RJ, Vlaskalic V. The invisalign system in adult orthodontics: mild crowding and space closure cases. J Clin Orthod. 2000;34:203\u201312.","journal-title":"J Clin Orthod"},{"key":"5841_CR7","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1186\/1472-6831-14-68","volume":"14","author":"M Simon","year":"2014","unstructured":"Simon M, Keilig L, Schwarze J, Jung BA, Bourauel C. Treatment outcome and efficacy of an aligner technique\u2013regarding incisor torque, premolar derotation and molar distalization. BMC Oral Health. 2014;14:68.","journal-title":"BMC Oral Health"},{"key":"5841_CR8","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.ajodo.2007.05.018","volume":"135","author":"ND Kravitz","year":"2009","unstructured":"Kravitz ND, Kusnoto B, BeGole E, Obrez A, Agran B. How well does invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with invisalign. Am J Orthod Dentofac Orthop. 2009;135:27\u201335.","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"5841_CR9","doi-asserted-by":"publisher","first-page":"1724","DOI":"10.14219\/jada.archive.2005.0117","volume":"136","author":"MO Lagrav\u00e8re","year":"2005","unstructured":"Lagrav\u00e8re MO, Flores-Mir C. The treatment effects of invisalign orthodontic aligners: a systematic review. J Am Dent Assoc. 2005;136:1724\u20139.","journal-title":"J Am Dent Assoc"},{"key":"5841_CR10","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1016\/j.ajodo.2005.06.002","volume":"128","author":"G Djeu","year":"2005","unstructured":"Djeu G, Shelton C, Maganzini A. Outcome assessment of invisalign and traditional orthodontic treatment compared with the American board of orthodontics objective grading system. Am J Orthod Dentofac Orthop. 2005;128:292\u20138.","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"5841_CR11","doi-asserted-by":"crossref","unstructured":"Dhingra A, Palomo JM, Stefanovic N, Eliliwi M, Elshebiny T. Comparing 3D tooth movement when implementing the same virtual setup on different software packages. J Clin Med. 2022;11.","DOI":"10.3390\/jcm11185351"},{"key":"5841_CR12","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.sjdr.2016.05.004","volume":"8","author":"SAA Bukhari","year":"2017","unstructured":"Bukhari SAA, Reddy KA, Reddy MR, Shah SH. Evaluation of virtual models (3Shape ortho System) in assessing accuracy and duration of model analyses based on the severity of crowding. Saudi J Dent Res. 2017;8:11\u20138.","journal-title":"Saudi J Dent Res"},{"key":"5841_CR13","unstructured":"Petrie A, Sabin C. Medical Statistics at a Glance. 3rd edition. John Wiley & Sons; West Sussex, UK; 2009."},{"key":"5841_CR14","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15:155\u201363.","journal-title":"J Chiropr Med"},{"key":"5841_CR15","first-page":"50","volume":"12","author":"M Eliliwi","year":"2023","unstructured":"Eliliwi M, ElShebiny T, De Menezes LM, Stefanovic N, Palomo JM. Comparing virtual setup software programs for clear aligner treatment. J World Fed Orthod. 2023;12:50\u20135.","journal-title":"J World Fed Orthod"},{"key":"5841_CR16","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1093\/ejo\/cjz075","volume":"42","author":"S Stucki","year":"2020","unstructured":"Stucki S, Gkantidis N. Assessment of techniques used for superimposition of maxillary and mandibular 3D surface models to evaluate tooth movement: a systematic review. Eur J Orthod. 2020;42:559\u201370.","journal-title":"Eur J Orthod"},{"key":"5841_CR17","doi-asserted-by":"publisher","first-page":"e0118810","DOI":"10.1371\/journal.pone.0118810","volume":"10","author":"N Gkantidis","year":"2015","unstructured":"Gkantidis N, Schauseil M, Pazera P, Zorkun B, Katsaros C, Ludwig B. Evaluation of 3-dimensional superimposition techniques on various skeletal structures of the head using surface models. PLoS ONE. 2015;10:e0118810.","journal-title":"PLoS ONE"},{"key":"5841_CR18","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1093\/ejo\/cjm061","volume":"29","author":"K Hayashi","year":"2007","unstructured":"Hayashi K, Uechi J, Lee SP, Mizoguchi I. Three-dimensional analysis of orthodontic tooth movement based on XYZ and finite helical axis systems. Eur J Orthod. 2007;29:589\u201395.","journal-title":"Eur J Orthod"},{"key":"5841_CR19","doi-asserted-by":"publisher","first-page":"5838","DOI":"10.1038\/s41598-017-06013-5","volume":"7","author":"G Vasilakos","year":"2017","unstructured":"Vasilakos G, Schilling R, Halazonetis D, Gkantidis N. Assessment of different techniques for 3D superimposition of serial digital maxillary dental casts on palatal structures. Sci Rep. 2017;7:5838.","journal-title":"Sci Rep"},{"key":"5841_CR20","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1093\/ejo\/cjx008","volume":"39","author":"S Talaat","year":"2017","unstructured":"Talaat S, Kaboudan A, Bourauel C, Ragy N, Kula K, Ghoneima A. Validity and reliability of three-dimensional palatal superimposition of digital dental models. Eur J Orthod. 2017;39:365\u201370.","journal-title":"Eur J Orthod"},{"key":"5841_CR21","doi-asserted-by":"publisher","first-page":"103933","DOI":"10.1016\/j.jdent.2021.103933","volume":"118","author":"B Yilmaz","year":"2022","unstructured":"Yilmaz B, Marques VR, Donmez MB, Cuellar AR, Lu WE, Abou-Ayash S, et al. Influence of 3D analysis software on measured deviations of CAD-CAM resin crowns from virtual design file: an in-vitro study. J Dent. 2022;118:103933.","journal-title":"J Dent"},{"key":"5841_CR22","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1186\/s12903-024-04522-0","volume":"24","author":"H Gamil","year":"2024","unstructured":"Gamil H, Marzouk E, Zaher A. Virtual bracket removal: a comparative assessment of different software packages. BMC Oral Health. 2024;24:770.","journal-title":"BMC Oral Health"},{"key":"5841_CR23","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1016\/j.prosdent.2023.06.028","volume":"132","author":"D Dede","year":"2024","unstructured":"Dede D, \u00c7akmak G, Donmez MB, K\u00fc\u00e7\u00fckekenci AS, Lu WE, Ni AA, et al. Effect of analysis software program on measured deviations in complete arch, implant-supported framework scans. J Prosthet Dent. 2024;132:211\u20138.","journal-title":"J Prosthet Dent"},{"key":"5841_CR24","doi-asserted-by":"publisher","first-page":"1333","DOI":"10.21608\/edj.2023.186146.2401","volume":"69","author":"S Sultan","year":"2023","unstructured":"Sultan S. Effect of three-dimensional target and reference data alignment method in an open digital dental communication application on the external surface trueness of CAD-CAM provisional crowns. Egypt Dent J. 2023;69:1333\u201341.","journal-title":"Egypt Dent J"},{"key":"5841_CR25","doi-asserted-by":"publisher","first-page":"101071","DOI":"10.1016\/j.gmod.2020.101071","volume":"109","author":"J Zhang","year":"2020","unstructured":"Zhang J, Li C, Song Q, Gao L, Lai Y-K. Automatic 3D tooth segmentation using convolutional neural networks in harmonic parameter space. Graph Models. 2020;109:101071.","journal-title":"Graph Models"},{"key":"5841_CR26","unstructured":"He X, Wang H, Hu H, Yang J, Feng Y, Wang G et al. Unsupervised pre-training improves tooth segmentation in 3-Dimensional intraoral mesh scans. Paper presented at: International Conference on Medical Imaging with Deep Learning; 2022 Jul 6\u20138; Z\u00fcrich, Switzerland."}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05841-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-05841-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05841-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,11]],"date-time":"2025-04-11T16:55:41Z","timestamp":1744390541000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-05841-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,11]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5841"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-05841-6","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,11]]},"assertion":[{"value":"13 September 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All the research procedures were performed in accordance with the relevant guidelines and regulations, as stated in the Declaration of Helsinki. The study was approved by the Institutional Review Board of the Faculty of Dentistry, Alexandria University, Alexandria, Egypt (IORG:0008839). Manuscript Ethics Committee number 0823\u2009\u2212\u200912\/2023. Oral assents and written informed consents were obtained from the patients and\/or their legal guardians, for the use of their records in the present study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not Applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"W.S. is a key opinion leader and a speaker for Invisalign (Align Technology Inc., Santa Clara, CA). The remaining authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"549"}}