{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T02:02:57Z","timestamp":1788141777105,"version":"build-2803163510"},"reference-count":54,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,29]],"date-time":"2025-04-29T00:00:00Z","timestamp":1745884800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,4,29]],"date-time":"2025-04-29T00:00:00Z","timestamp":1745884800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Ege University Scientific Research Projects Coordination Unit","award":["22767"],"award-info":[{"award-number":["22767"]}]},{"name":"Ege University Scientific Research Projects Coordination Unit","award":["22767"],"award-info":[{"award-number":["22767"]}]},{"name":"Ege University Scientific Research Projects Coordination Unit","award":["22767"],"award-info":[{"award-number":["22767"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"DOI":"10.1186\/s12903-025-05855-0","type":"journal-article","created":{"date-parts":[[2025,4,29]],"date-time":"2025-04-29T21:45:07Z","timestamp":1745963107000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Evaluation of trabecular bone microstructure and cortical morphology using cone-beam and micro-CT images: impact of tube voltage setting"],"prefix":"10.1186","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8353-5347","authenticated-orcid":false,"given":"O\u011fuzhan","family":"Baydar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erinc","family":"Onem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Mert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B Guniz","family":"Baksi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,4,29]]},"reference":[{"issue":"4","key":"5855_CR1","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1563\/aaid-joi-D-19-00028","volume":"46","author":"OJ de El\u00edo","year":"2020","unstructured":"de El\u00edo OJ, del Canto DA, del Canto DM, Orea CJ, del Canto PM, Calvo JS. Alveolar Bone Density and Width Affect Primary Implant Stability. Journal of Oral Implantology. 2020;46(4):389\u201395. https:\/\/doi.org\/10.1563\/aaid-joi-D-19-00028.","journal-title":"Journal of Oral Implantology"},{"issue":"2","key":"5855_CR2","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1111\/J.1600-0501.2004.00969.X","volume":"15","author":"MI Fanuscu","year":"2004","unstructured":"Fanuscu MI, Chang TL. Three-dimensional morphometric analysis of human cadaver bone: microstructural data from maxilla and mandible. Clin Oral Implants Res. 2004;15(2):213\u20138. https:\/\/doi.org\/10.1111\/J.1600-0501.2004.00969.X.","journal-title":"Clin Oral Implants Res"},{"issue":"6","key":"5855_CR3","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1097\/ID.0B013E3181BB840D","volume":"18","author":"S Sakka","year":"2009","unstructured":"Sakka S, Coulthard P. Bone quality: a reality for the process of osseointegration. Implant Dent. 2009;18(6):480\u20135. https:\/\/doi.org\/10.1097\/ID.0B013E3181BB840D.","journal-title":"Implant Dent"},{"key":"5855_CR4","doi-asserted-by":"publisher","unstructured":"Peev S, Yotsova R, Parushev . Histomorphometric Analysis of Osseointegrated Intraosseous Dental Implants Using Undecalcified Specimens: A Scoping Review. Biomimetics. 2024;9(11):672. https:\/\/doi.org\/10.3390\/biomimetics9110672","DOI":"10.3390\/biomimetics9110672"},{"issue":"3","key":"5855_CR5","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/J.OOOO.2018.11.014","volume":"127","author":"K Kulah","year":"2019","unstructured":"Kulah K, Gulsahi A, Kamburo\u011flu K, et al. Evaluation of maxillary trabecular microstructure as an indicator of implant stability by using 2 cone beam computed tomography systems and micro-computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol. 2019;127(3):247\u201356. https:\/\/doi.org\/10.1016\/J.OOOO.2018.11.014.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"issue":"7","key":"5855_CR6","doi-asserted-by":"publisher","first-page":"1468","DOI":"10.1002\/JBMR.141","volume":"25","author":"ML Bouxsein","year":"2010","unstructured":"Bouxsein ML, Boyd SK, Christiansen BA, Guldberg RE, Jepsen KJ, M\u00fcller R. Guidelines for assessment of bone microstructure in rodents using micro-computed tomography. J Bone Miner Res. 2010;25(7):1468\u201386. https:\/\/doi.org\/10.1002\/JBMR.141.","journal-title":"J Bone Miner Res"},{"issue":"8","key":"5855_CR7","doi-asserted-by":"publisher","first-page":"2179","DOI":"10.1007\/S11999-010-1766-X","volume":"469","author":"AJ Burghardt","year":"2011","unstructured":"Burghardt AJ, Link TM, Majumdar S. High-resolution computed tomography for clinical imaging of bone microarchitecture. Clin Orthop Relat Res. 2011;469(8):2179\u201393. https:\/\/doi.org\/10.1007\/S11999-010-1766-X.","journal-title":"Clin Orthop Relat Res"},{"key":"5855_CR8","doi-asserted-by":"publisher","unstructured":"Ritman EL. Current Status of Developments and Applications of Micro-CT. 2011;13:531\u2013552. https:\/\/doi.org\/10.1146\/annurev-bioeng-071910-124717","DOI":"10.1146\/annurev-bioeng-071910-124717"},{"key":"5855_CR9","doi-asserted-by":"publisher","unstructured":"Lyu HZ, Lee JH. Correlation between two-dimensional micro-CT and histomorphometry for assessment of the implant osseointegration in rabbit tibia model. Biomater Res. 2021;25(1). https:\/\/doi.org\/10.1186\/s40824-021-00213-x","DOI":"10.1186\/s40824-021-00213-x"},{"issue":"Suppl 1","key":"5855_CR10","first-page":"77","volume":"11","author":"R Jacobs","year":"2018","unstructured":"Jacobs R, Vranckx M, Vanderstuyft T, Quirynen M, Salmon B. CBCT vs other imaging modalities to assess peri-implant bone and diagnose complications: a systematic review. Eur J Oral Implantol. 2018;11(Suppl 1):77\u201392.","journal-title":"Eur J Oral Implantol"},{"issue":"23","key":"5855_CR11","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abc367","volume":"65","author":"I Guha","year":"2020","unstructured":"Guha I, Klintstr\u00f6m B, Klintstr\u00f6m E, et al. A comparative study of trabecular bone micro-structural measurements using different CT modalities. Phys Med Biol. 2020;65(23): 235029. https:\/\/doi.org\/10.1088\/1361-6560\/abc367.","journal-title":"Phys Med Biol"},{"issue":"1","key":"5855_CR12","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1186\/s12903-021-01595-z","volume":"21","author":"N Ibrahim","year":"2021","unstructured":"Ibrahim N, Parsa A, Hassan B, et al. Comparison of anterior and posterior trabecular bone microstructure of human mandible using cone-beam CT and micro CT. BMC Oral Health. 2021;21(1):249. https:\/\/doi.org\/10.1186\/s12903-021-01595-z.","journal-title":"BMC Oral Health"},{"issue":"1","key":"5855_CR13","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1111\/CLR.12315","volume":"26","author":"A Parsa","year":"2015","unstructured":"Parsa A, Ibrahim N, Hassan B, van der Stelt P, Wismeijer D. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT. Clin Oral Implants Res. 2015;26(1):e1\u20137. https:\/\/doi.org\/10.1111\/CLR.12315.","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"5855_CR14","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1186\/s12880-019-0313-9","volume":"19","author":"RT He","year":"2019","unstructured":"He RT, Tu MG, Huang HL, Tsai MT, Wu J, Hsu JT. Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography. BMC Med Imaging. 2019;19(1):10. https:\/\/doi.org\/10.1186\/s12880-019-0313-9.","journal-title":"BMC Med Imaging"},{"issue":"2","key":"5855_CR15","doi-asserted-by":"publisher","first-page":"20130329","DOI":"10.1259\/dmfr.20130329","volume":"43","author":"N Ibrahim","year":"2014","unstructured":"Ibrahim N, Parsa A, Hassan B, van der Stelt P, Aartman IHA, Nambiar P. Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study. Dentomaxillofacial Radiology. 2014;43(2):20130329. https:\/\/doi.org\/10.1259\/dmfr.20130329.","journal-title":"Dentomaxillofacial Radiology"},{"issue":"2","key":"5855_CR16","doi-asserted-by":"publisher","first-page":"171","DOI":"10.5624\/isd.20220025","volume":"52","author":"MA Tayman","year":"2022","unstructured":"Tayman MA, Kamburo\u011flu K, Ocak M, \u00d6zen D. Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study. Imaging Sci Dent. 2022;52(2):171. https:\/\/doi.org\/10.5624\/isd.20220025.","journal-title":"Imaging Sci Dent"},{"issue":"6","key":"5855_CR17","doi-asserted-by":"publisher","first-page":"368","DOI":"10.3390\/diagnostics10060368","volume":"10","author":"MT Tsai","year":"2020","unstructured":"Tsai MT, He RT, Huang HL, Tu MG, Hsu JT. Effect of Scanning Resolution on the Prediction of Trabecular Bone Microarchitectures Using Dental Cone Beam Computed Tomography. Diagnostics. 2020;10(6):368. https:\/\/doi.org\/10.3390\/diagnostics10060368.","journal-title":"Diagnostics"},{"issue":"8","key":"5855_CR18","doi-asserted-by":"publisher","first-page":"20150078","DOI":"10.1259\/dmfr.20150078","volume":"44","author":"R Pauwels","year":"2015","unstructured":"Pauwels R, Faruangsaeng T, Charoenkarn T, Ngonphloy N, Panmekiate S. Effect of exposure parameters and voxel size on bone structure analysis in CBCT. Dentomaxillofacial Radiology. 2015;44(8):20150078. https:\/\/doi.org\/10.1259\/dmfr.20150078.","journal-title":"Dentomaxillofacial Radiology"},{"issue":"4","key":"5855_CR19","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0154367","volume":"11","author":"PY Hsu","year":"2016","unstructured":"Hsu PY, Tsai MT, Wang SP, Chen YJ, Wu J, Hsu JT. Cortical Bone Morphological and Trabecular Bone Microarchitectural Changes in the Mandible and Femoral Neck of Ovariectomized Rats. PLoS ONE. 2016;11(4): e0154367. https:\/\/doi.org\/10.1371\/journal.pone.0154367.","journal-title":"PLoS ONE"},{"issue":"5","key":"5855_CR20","doi-asserted-by":"publisher","first-page":"20140322","DOI":"10.1259\/dmfr.20140322","volume":"44","author":"S Panmekiate","year":"2015","unstructured":"Panmekiate S, Ngonphloy N, Charoenkarn T, Faruangsaeng T, Pauwels R. Comparison of mandibular bone microarchitecture between micro-CT and CBCT images. Dentomaxillofacial Radiology. 2015;44(5):20140322. https:\/\/doi.org\/10.1259\/dmfr.20140322.","journal-title":"Dentomaxillofacial Radiology"},{"issue":"6","key":"5855_CR21","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1016\/j.bone.2010.08.023","volume":"47","author":"M Doube","year":"2010","unstructured":"Doube M, K\u0142osowski MM, Arganda-Carreras I, et al. BoneJ: Free and extensible bone image analysis in ImageJ. Bone. 2010;47(6):1076\u20139. https:\/\/doi.org\/10.1016\/j.bone.2010.08.023.","journal-title":"Bone"},{"issue":"10","key":"5855_CR22","doi-asserted-by":"publisher","first-page":"472","DOI":"10.3390\/md22100472","volume":"22","author":"J Saetang","year":"2024","unstructured":"Saetang J, Issuriya A, Suyapoh W, Sornying P, Nilsuwan K, Benjakul S. Bio-Calcium from Skipjack Tuna Frame Attenuates Bone Loss in Ovariectomy-Induced Osteoporosis Rats. Mar Drugs. 2024;22(10):472. https:\/\/doi.org\/10.3390\/md22100472.","journal-title":"Mar Drugs"},{"issue":"2","key":"5855_CR23","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. J Chiropr Med. 2016;15(2):155\u201363. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012.","journal-title":"J Chiropr Med"},{"issue":"3","key":"5855_CR24","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1148\/RADIOL.2273020420","volume":"227","author":"N Boutry","year":"2003","unstructured":"Boutry N, Cortet B, Dubois P, Marchandise X, Cotten A. Trabecular bone structure of the calcaneus: preliminary in vivo MR imaging assessment in men with osteoporosis. Radiology. 2003;227(3):708\u201317. https:\/\/doi.org\/10.1148\/RADIOL.2273020420.","journal-title":"Radiology"},{"issue":"3","key":"5855_CR25","doi-asserted-by":"publisher","first-page":"791","DOI":"10.30621\/jbachs.1037333","volume":"6","author":"E Bilgili","year":"2022","unstructured":"Bilgili E. Influence of Voxel Size on Evaluation of Trabecular Bone Microstructure on Human Mandibles: A CBCT study. Journal of Basic and Clinical Health Sciences. 2022;6(3):791\u20137. https:\/\/doi.org\/10.30621\/jbachs.1037333.","journal-title":"Journal of Basic and Clinical Health Sciences"},{"issue":"2","key":"5855_CR26","doi-asserted-by":"publisher","first-page":"2972","DOI":"10.36922\/arnm.2972","volume":"2","author":"J Anthony Rabba","year":"2024","unstructured":"Anthony Rabba J, Irinam Efenji G, Omachoko Uloko F, et al. Investigation of the optimal tube voltage kV exposure parameters for general X-ray of dental cone-beam computed tomography: A cephalometric view. Advances in Radiotherapy & Nuclear Medicine. 2024;2(2):2972. https:\/\/doi.org\/10.36922\/arnm.2972.","journal-title":"Advances in Radiotherapy & Nuclear Medicine"},{"key":"5855_CR27","doi-asserted-by":"publisher","unstructured":"Pauwels R, Silkosessak O, Jacobs R, Bogaerts R, Bosmans H, Panmekiate S. A pragmatic approach to determine the optimal kVp in cone beam CT: balancing contrast-to-noise ratio and radiation dose. Dentomaxillofacial Radiology. 2014;43. https:\/\/doi.org\/10.1259\/dmfr.20140059","DOI":"10.1259\/dmfr.20140059"},{"key":"5855_CR28","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.ejmp.2021.07.007","volume":"88","author":"T Kaasalainen","year":"2021","unstructured":"Kaasalainen T, Ekholm M, Siiskonen T, Kortesniemi M. Dental cone beam CT: An updated review. Physica Med. 2021;88:193\u2013217. https:\/\/doi.org\/10.1016\/j.ejmp.2021.07.007.","journal-title":"Physica Med"},{"issue":"1","key":"5855_CR29","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s12917-016-0921-3","volume":"13","author":"A Szabelska","year":"2016","unstructured":"Szabelska A, Tatara MR, Krupski W. Morphological, densitometric and mechanical properties of mandible in 5-month-old Polish Merino sheep. BMC Vet Res. 2016;13(1):12. https:\/\/doi.org\/10.1186\/s12917-016-0921-3.","journal-title":"BMC Vet Res"},{"issue":"4","key":"5855_CR30","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1007\/s00198-010-1289-z","volume":"22","author":"E Veigel","year":"2011","unstructured":"Veigel E, Moore RJ, Zarrinkalam MR, et al. Osteopenia in the maxillofacial area: a study in sheep. Osteoporos Int. 2011;22(4):1115\u201321. https:\/\/doi.org\/10.1007\/s00198-010-1289-z.","journal-title":"Osteoporos Int"},{"issue":"2","key":"5855_CR31","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1007\/s11914-018-0431-2","volume":"16","author":"IR Dias","year":"2018","unstructured":"Dias IR, Camassa JA, Bordelo JA, et al. Preclinical and Translational Studies in Small Ruminants (Sheep and Goat) as Models for Osteoporosis Research. Curr Osteoporos Rep. 2018;16(2):182\u201397. https:\/\/doi.org\/10.1007\/s11914-018-0431-2.","journal-title":"Curr Osteoporos Rep"},{"key":"5855_CR32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.22203\/eCM.v013a01","volume":"13","author":"A Pearce","year":"2007","unstructured":"Pearce A, Richards R, Milz S, Schneider E, Pearce S. Animal models for implant biomaterial research in bone: A review. Eur Cell Mater. 2007;13:1\u201310. https:\/\/doi.org\/10.22203\/eCM.v013a01.","journal-title":"Eur Cell Mater"},{"issue":"1","key":"5855_CR33","doi-asserted-by":"publisher","first-page":"7277","DOI":"10.1038\/s41598-018-25597-0","volume":"8","author":"PJ Watson","year":"2018","unstructured":"Watson PJ, Fitton LC, Meloro C, Fagan MJ, Gr\u00f6ning F. Mechanical adaptation of trabecular bone morphology in the mammalian mandible. Sci Rep. 2018;8(1):7277. https:\/\/doi.org\/10.1038\/s41598-018-25597-0.","journal-title":"Sci Rep"},{"issue":"5","key":"5855_CR34","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1002\/jor.1100170506","volume":"17","author":"FC den Boer","year":"1999","unstructured":"den Boer FC, Patka P, Bakker FC, et al. New segmental long bone defect model in sheep: Quantitative analysis of healing with dual energy X-ray absorptiometry. J Orthop Res. 1999;17(5):654\u201360. https:\/\/doi.org\/10.1002\/jor.1100170506.","journal-title":"J Orthop Res"},{"issue":"1","key":"5855_CR35","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1186\/s12891-020-03362-7","volume":"21","author":"D Cabrera","year":"2020","unstructured":"Cabrera D, Kruger M, Wolber FM, Roy NC, Fraser K. Effects of short- and long-term glucocorticoid-induced osteoporosis on plasma metabolome and lipidome of ovariectomized sheep. BMC Musculoskelet Disord. 2020;21(1):349. https:\/\/doi.org\/10.1186\/s12891-020-03362-7.","journal-title":"BMC Musculoskelet Disord"},{"key":"5855_CR36","doi-asserted-by":"publisher","unstructured":"Coelho CA, Bordelo JP, Camassa JA, et al. Evaluation of hematology, general serum biochemistry, bone turnover markers and bone marrow cytology in a glucocorticoid treated ovariectomized sheep model for osteoporosis research. An Acad Bras Cienc. 2020;92(4). https:\/\/doi.org\/10.1590\/0001-3765202020200435","DOI":"10.1590\/0001-3765202020200435"},{"issue":"10","key":"5855_CR37","doi-asserted-by":"publisher","first-page":"1640","DOI":"10.1359\/JBMR.040705","volume":"19","author":"JH Waarsing","year":"2004","unstructured":"Waarsing JH, Day JS, Weinans H. An Improved Segmentation Method for In Vivo \u03bcCT Imaging. J Bone Miner Res. 2004;19(10):1640\u201350. https:\/\/doi.org\/10.1359\/JBMR.040705.","journal-title":"J Bone Miner Res"},{"key":"5855_CR38","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.bone.2017.11.021","volume":"107","author":"AH Alomari","year":"2018","unstructured":"Alomari AH, Wille ML, Langton CM. Bone volume fraction and structural parameters for estimation of mechanical stiffness and failure load of human cancellous bone samples; in-vitro comparison of ultrasound transit time spectroscopy and X-ray \u03bcCT. Bone. 2018;107:145\u201353. https:\/\/doi.org\/10.1016\/j.bone.2017.11.021.","journal-title":"Bone"},{"issue":"9","key":"5855_CR39","doi-asserted-by":"publisher","first-page":"103","DOI":"10.21474\/IJAR01\/7650","volume":"6","author":"K Tabarany","year":"2018","unstructured":"Tabarany K, Aboulfotouh M, Ashmawy M. Validity of cone beam computed tomography voxel density values: a review. Int J Adv Res (Indore). 2018;6(9):103\u201321. https:\/\/doi.org\/10.21474\/IJAR01\/7650.","journal-title":"Int J Adv Res (Indore)"},{"issue":"8","key":"5855_CR40","doi-asserted-by":"publisher","first-page":"941","DOI":"10.1111\/clr.12163","volume":"25","author":"N Ibrahim","year":"2014","unstructured":"Ibrahim N, Parsa A, Hassan B, van der Stelt P, Aartman IHA, Wismeijer D. Accuracy of trabecular bone microstructural measurement at planned dental implant sites using cone-beam <scp>CT<\/scp> datasets. Clin Oral Implants Res. 2014;25(8):941\u20135. https:\/\/doi.org\/10.1111\/clr.12163.","journal-title":"Clin Oral Implants Res"},{"issue":"8","key":"5855_CR41","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1111\/J.1600-0501.2011.02243.X","volume":"23","author":"RC de Oliveira","year":"2012","unstructured":"de Oliveira RC, Leles CR, Lindh C, Ribeiro-Rotta RF. Bone tissue microarchitectural characteristics at dental implant sites. Part 1: identification of clinical-related parameters. Clin Oral Implants Res. 2012;23(8):981\u20136. https:\/\/doi.org\/10.1111\/J.1600-0501.2011.02243.X.","journal-title":"Clin Oral Implants Res"},{"issue":"2","key":"5855_CR42","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1007\/S00330-009-1571-7","volume":"20","author":"AS Issever","year":"2010","unstructured":"Issever AS, Link TM, Kentenich M, et al. Assessment of trabecular bone structure using MDCT: comparison of 64- and 320-slice CT using HR-pQCT as the reference standard. Eur Radiol. 2010;20(2):458\u201368. https:\/\/doi.org\/10.1007\/S00330-009-1571-7.","journal-title":"Eur Radiol"},{"issue":"8","key":"5855_CR43","doi-asserted-by":"publisher","first-page":"20130145","DOI":"10.1259\/dmfr.20130145","volume":"42","author":"J Van Dessel","year":"2013","unstructured":"Van Dessel J, Huang Y, Depypere M, Rubira-Bullen I, Maes F, Jacobs R. A comparative evaluation of cone beam CT and micro-CT on trabecular bone structures in the human mandible. Dentomaxillofacial Radiology. 2013;42(8):20130145. https:\/\/doi.org\/10.1259\/dmfr.20130145.","journal-title":"Dentomaxillofacial Radiology"},{"issue":"3","key":"5855_CR44","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1016\/j.ejrad.2009.04.074","volume":"71","author":"JE Adams","year":"2009","unstructured":"Adams JE. Quantitative computed tomography. Eur J Radiol. 2009;71(3):415\u201324. https:\/\/doi.org\/10.1016\/j.ejrad.2009.04.074.","journal-title":"Eur J Radiol"},{"issue":"1","key":"5855_CR45","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1186\/1475-925X-12-115","volume":"12","author":"JT Ho","year":"2013","unstructured":"Ho JT, Wu J, Huang HL, Chen MY, Fuh LJ, Hsu JT. Trabecular bone structural parameters evaluated using dental cone-beam computed tomography: cellular synthetic bones. Biomed Eng Online. 2013;12(1):115. https:\/\/doi.org\/10.1186\/1475-925X-12-115.","journal-title":"Biomed Eng Online"},{"issue":"3","key":"5855_CR46","doi-asserted-by":"publisher","first-page":"227","DOI":"10.2334\/josnusd.54.227","volume":"54","author":"B Bechara","year":"2012","unstructured":"Bechara B, McMahan CA, Moore WS, Noujeim M, Geha H, Teixeira FB. Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines. J Oral Sci. 2012;54(3):227\u201332. https:\/\/doi.org\/10.2334\/josnusd.54.227.","journal-title":"J Oral Sci."},{"issue":"5","key":"5855_CR47","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1259\/DMFR\/30642039","volume":"40","author":"R Schulze","year":"2011","unstructured":"Schulze R, Heil U, Gro\u00df D, et al. Artefacts in CBCT: a review. Dentomaxillofac Radiol. 2011;40(5):265\u201373. https:\/\/doi.org\/10.1259\/DMFR\/30642039.","journal-title":"Dentomaxillofac Radiol"},{"issue":"9","key":"5855_CR48","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1016\/j.joen.2014.04.014","volume":"40","author":"D Maret","year":"2014","unstructured":"Maret D, Peters OA, Galibourg A, et al. Comparison of the Accuracy of 3-dimensional Cone-beam Computed Tomography and Micro-Computed Tomography Reconstructions by Using Different Voxel Sizes. J Endod. 2014;40(9):1321\u20136. https:\/\/doi.org\/10.1016\/j.joen.2014.04.014.","journal-title":"J Endod"},{"issue":"8","key":"5855_CR49","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1259\/dmfr\/81804525","volume":"41","author":"D Maret","year":"2012","unstructured":"Maret D, Telmon N, Peters OA, et al. Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT. Dentomaxillofacial Radiology. 2012;41(8):649\u201355. https:\/\/doi.org\/10.1259\/dmfr\/81804525.","journal-title":"Dentomaxillofacial Radiology"},{"issue":"3","key":"5855_CR50","doi-asserted-by":"publisher","first-page":"152","DOI":"10.5051\/jpis.2016.46.3.152","volume":"46","author":"T Sugiura","year":"2016","unstructured":"Sugiura T, Yamamoto K, Horita S, Murakami K, Tsutsumi S, Kirita T. The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis. J Periodontal Implant Sci. 2016;46(3):152\u201365. https:\/\/doi.org\/10.5051\/jpis.2016.46.3.152.","journal-title":"J Periodontal Implant Sci"},{"issue":"8","key":"5855_CR51","doi-asserted-by":"publisher","first-page":"20180151","DOI":"10.1259\/dmfr.20180151","volume":"47","author":"DQ Freitas","year":"2018","unstructured":"Freitas DQ, Fontenele RC, Nascimento EHL, Vasconcelos TV, Noujeim M. Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts. Dentomaxillofacial Radiology. 2018;47(8):20180151. https:\/\/doi.org\/10.1259\/dmfr.20180151.","journal-title":"Dentomaxillofacial Radiology"},{"issue":"1","key":"5855_CR52","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1007\/s00330-016-4353-z","volume":"27","author":"R Pauwels","year":"2017","unstructured":"Pauwels R, Jacobs R, Bogaerts R, Bosmans H, Panmekiate S. Determination of size-specific exposure settings in dental cone-beam CT. Eur Radiol. 2017;27(1):279\u201385. https:\/\/doi.org\/10.1007\/s00330-016-4353-z.","journal-title":"Eur Radiol"},{"issue":"1","key":"5855_CR53","first-page":"95","volume":"10","author":"J Van Dessel","year":"2017","unstructured":"Van Dessel J, Nicolielo LFP, Huang Y, et al. Accuracy and reliability of different cone beam computed tomography (CBCT) devices for structural analysis of alveolar bone in comparison with multislice CT and micro-CT. Eur J Oral Implantol. 2017;10(1):95\u2013105.","journal-title":"Eur J Oral Implantol"},{"issue":"4","key":"5855_CR54","doi-asserted-by":"publisher","first-page":"187","DOI":"10.4103\/picr.PICR_123_17","volume":"8","author":"P Ranganathan","year":"2017","unstructured":"Ranganathan P, Pramesh C, Aggarwal R. Common pitfalls in statistical analysis: Measures of agreement. Perspect Clin Res. 2017;8(4):187. https:\/\/doi.org\/10.4103\/picr.PICR_123_17.","journal-title":"Perspect Clin Res"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05855-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-05855-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05855-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,30]],"date-time":"2025-04-30T10:04:05Z","timestamp":1746007445000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-05855-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,29]]},"references-count":54,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5855"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-05855-0","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,29]]},"assertion":[{"value":"20 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This in vitro study did not involve any experiments with live animals or human participants conducted by the authors. All methods were performed in compliance with institutional, national, and international guidelines, including Directive 2010\/63\/EU on the protection of animals used for scientific purposes. The study protocol was reviewed and approved by the University's Local Ethics Committee for Animal Experiments (protocol no: 2020\u2013034). The committee confirmed that the use of tissues from deceased animals, procured from local meat markets, does not raise ethical concerns and is exempt from requiring additional ethics approval. The fresh animal samples used in this study were obtained from ovine producers as meat products intended for human consumption. No animals were specifically sacrificed for the purposes of this research. Informed consent from owners was not applicable, as the samples were commercially sourced and not traceable to individual ownership.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"664"}}