{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T14:05:42Z","timestamp":1768485942730,"version":"3.49.0"},"reference-count":50,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,20]],"date-time":"2025-04-20T00:00:00Z","timestamp":1745107200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,4,20]],"date-time":"2025-04-20T00:00:00Z","timestamp":1745107200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"DOI":"10.1186\/s12903-025-05911-9","type":"journal-article","created":{"date-parts":[[2025,4,20]],"date-time":"2025-04-20T16:44:16Z","timestamp":1745167456000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Evaluation of the effect of etching with ytterbium fiber laser on the bond strength, color stability, and fracture analysis of lithium disilicate ceramics to bovine teeth: an in vitro study"],"prefix":"10.1186","volume":"25","author":[{"given":"G\u00f6knil","family":"Alkan Demeto\u011flu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Esra","family":"Talay \u00c7evl\u00efk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,4,20]]},"reference":[{"issue":"2","key":"5911_CR1","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.jpor.2016.01.003","volume":"60","author":"TF Alghazzawi","year":"2016","unstructured":"Alghazzawi TF. Advancements in CAD\/CAM technology: oOptions for practical implementation. J Prosthodontic Res. 2016;60(2):72\u201384.","journal-title":"J Prosthodontic Res"},{"key":"5911_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12903-019-0838-x","volume":"19","author":"F Zarone","year":"2019","unstructured":"Zarone F, Di Mauro MI, Ausiello P, Ruggiero G, Sorrentino R. Current status on lithium disilicate and zirconia: a narrative review. BMC Oral Health. 2019;19:1\u201314.","journal-title":"BMC Oral Health"},{"issue":"11","key":"5911_CR3","doi-asserted-by":"publisher","first-page":"1927","DOI":"10.1016\/j.dental.2024.09.004","volume":"40","author":"OE Pecho","year":"2024","unstructured":"Pecho OE, Alvarez-Lloret P, Ionescu AM, Cardona JC, Ghinea R, S\u00e1nchez-S\u00e1nchez P, et al. Influence of microstructure on optical properties of CAD-CAM lithium disilicate glass-ceramics. Dent Mater. 2024;40(11):1927\u201336.","journal-title":"Dent Mater"},{"key":"5911_CR4","doi-asserted-by":"publisher","first-page":"105373","DOI":"10.1016\/j.jmbbm.2022.105373","volume":"134","author":"GF Chiapinotto","year":"2022","unstructured":"Chiapinotto GF, da Rosa LS, Scotti N, Kleverlaan CJ, Valandro LF, Pereira GKR. Does adhesive Luting promote improved fatigue performance of lithium disilicate simplified crowns? J Mech Behav Biomed Mater. 2022;134:105373.","journal-title":"J Mech Behav Biomed Mater"},{"key":"5911_CR5","unstructured":"Saldanha da Rosa L, Serafini Dapieve K, Dalla-Nora F, Pivetta Rippe M, Felipe Valandro L, Sarkis-Onofre R et al. Does adhesive Luting reinforce the mechanical properties of dental ceramics used as restorative materials? A systematic review and Meta-Analysis. J Adhesive Dentistry. 2022;24(1)."},{"issue":"5","key":"5911_CR6","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1016\/j.dental.2003.05.004","volume":"20","author":"M Rosentritt","year":"2004","unstructured":"Rosentritt M, Behr M, Lang R, Handel G. Influence of cement type on the marginal adaptation of all-ceramic MOD inlays. Dent Mater. 2004;20(5):463\u20139.","journal-title":"Dent Mater"},{"key":"5911_CR7","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1590\/S1806-83242011000300012","volume":"25","author":"E Y\u00fcksel","year":"2011","unstructured":"Y\u00fcksel E, Zaimo\u011flu A. Influence of marginal fit and cement types on microleakage of all-ceramic crown systems. Brazilian Oral Res. 2011;25:261\u20136.","journal-title":"Brazilian Oral Res"},{"issue":"2","key":"5911_CR8","first-page":"97","volume":"67","author":"O El-Mowafy","year":"2001","unstructured":"El-Mowafy O. The use of resin cements in restorative dentistry to overcome retention problems. Journal-Canadian Dent Association. 2001;67(2):97\u2013102.","journal-title":"Journal-Canadian Dent Association"},{"key":"5911_CR9","doi-asserted-by":"publisher","first-page":"S20","DOI":"10.14219\/jada.archive.2011.0339","volume":"142","author":"MA Vargas","year":"2011","unstructured":"Vargas MA, Bergeron C, Diaz-Arnold A. Cementing all-ceramic restorations: recommendations for success. J Am Dent Association. 2011;142:20S\u2013 24S.","journal-title":"J Am Dent Association"},{"issue":"8","key":"5911_CR10","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1016\/j.dental.2003.05.010","volume":"20","author":"AA El Zohairy","year":"2004","unstructured":"El Zohairy AA, De Gee AJ, Hassan FM, Feilzer AJ. The effect of adhesives with various degrees of hydrophilicity on resin ceramic bond durability. Dent Mater. 2004;20(8):778\u201387.","journal-title":"Dent Mater"},{"issue":"4","key":"5911_CR11","doi-asserted-by":"publisher","first-page":"885","DOI":"10.1002\/jbm.b.33619","volume":"105","author":"C Prochnow","year":"2017","unstructured":"Prochnow C, Venturini AB, Grasel R, Bottino MC, Valandro LF. Effect of etching with distinct hydrofluoric acid concentrations on the flexural strength of a lithium disilicate-based glass ceramic. J Biomedical Mater Res Part B: Appl Biomaterials. 2017;105(4):885\u201391.","journal-title":"J Biomedical Mater Res Part B: Appl Biomaterials"},{"key":"5911_CR12","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1590\/0103-6440201601024","volume":"27","author":"D Sundfeld","year":"2016","unstructured":"Sundfeld D, Correr-Sobrinho L, Pini NIP, Costa AR, Sundfeld RH, Pfeifer CS, et al. The effect of hydrofluoric acid concentration and heat on the bonding to lithium disilicate glass ceramic. Braz Dent J. 2016;27:727\u201333.","journal-title":"Braz Dent J"},{"issue":"3","key":"5911_CR13","doi-asserted-by":"publisher","first-page":"618","DOI":"10.1016\/j.prosdent.2014.04.001","volume":"112","author":"S Turgut","year":"2014","unstructured":"Turgut S, Ba\u011f\u0131\u015f B, Korkmaz FM, Tamam E. Do surface treatments affect the optical properties of ceramic veneers? J Prosthet Dent. 2014;112(3):618\u201324.","journal-title":"J Prosthet Dent"},{"issue":"9","key":"5911_CR14","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1016\/j.dental.2023.07.004","volume":"39","author":"H Al-Johani","year":"2023","unstructured":"Al-Johani H, Haider J, Silikas N, Satterthwaite J. Effect of surface treatments on optical, topographical and mechanical properties of CAD\/CAM reinforced lithium silicate glass ceramics. Dent Mater. 2023;39(9):779\u201389.","journal-title":"Dent Mater"},{"key":"5911_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40563-017-0096-6","volume":"5","author":"G Bruzi","year":"2017","unstructured":"Bruzi G, Carvalho AO, Giannini M, Maia HP, Magne P. Post-etching cleaning influences the resin shear bond strength to CAD\/CAM lithium-disilicate ceramics. Appl Adhes Sci. 2017;5:1\u20139.","journal-title":"Appl Adhes Sci"},{"issue":"12","key":"5911_CR16","doi-asserted-by":"publisher","first-page":"e330","DOI":"10.1016\/j.dental.2014.08.373","volume":"30","author":"L Xiaoping","year":"2014","unstructured":"Xiaoping L, Dongfeng R, Silikas N. Effect of etching time and resin bond on the flexural strength of IPS e. max press glass ceramic. Dent Mater. 2014;30(12):e330\u2013e6.","journal-title":"Dent Mater"},{"issue":"4","key":"5911_CR17","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1016\/j.dental.2006.03.002","volume":"23","author":"O Addison","year":"2007","unstructured":"Addison O, Marquis PM, Fleming GJ. The impact of hydrofluoric acid surface treatments on the performance of a porcelain laminate restorative material. Dent Mater. 2007;23(4):461\u20138.","journal-title":"Dent Mater"},{"issue":"5","key":"5911_CR18","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1111\/j.1532-849X.2008.00319.x","volume":"17","author":"T Hooshmand","year":"2008","unstructured":"Hooshmand T, Parvizi S, Keshvad A. Effect of surface acid etching on the biaxial flexural strength of two hot-pressed glass ceramics. J Prosthodont. 2008;17(5):415\u20139.","journal-title":"J Prosthodont"},{"key":"5911_CR19","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1007\/s00784-011-0636-6","volume":"16","author":"M \u00d6zcan","year":"2012","unstructured":"\u00d6zcan M, Allahbeickaraghi A, D\u00fcndar M. Possible hazardous effects of hydrofluoric acid and recommendations for treatment approach: a review. Clin Oral Invest. 2012;16:15\u201323.","journal-title":"Clin Oral Invest"},{"issue":"2","key":"5911_CR20","doi-asserted-by":"publisher","first-page":"98","DOI":"10.4047\/jap.2013.5.2.98","volume":"5","author":"P Kursoglu","year":"2013","unstructured":"Kursoglu P, Motro PFK, Yurdaguven H. Shear bond strength of resin cement to an acid etched and a laser irradiated ceramic surface. J Adv Prosthodont. 2013;5(2):98\u2013103.","journal-title":"J Adv Prosthodont"},{"issue":"9","key":"5911_CR21","first-page":"902","volume":"34","author":"BJ Dunn","year":"1992","unstructured":"Dunn BJ, MacKinnon MA, Knowlden NF, Billmaier DJ, Derelanko MJ, Rusch GM, et al. Hydrofluoric acid dermal Burns: an assessment of treatment efficacy using an experimental pig model. J Occup Environ Med. 1992;34(9):902\u20139.","journal-title":"J Occup Environ Med"},{"issue":"5","key":"5911_CR22","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1016\/S0735-6757(98)90008-0","volume":"16","author":"M Gallerani","year":"1998","unstructured":"Gallerani M, Bettoli V, Peron L, Manfredini R. Systemic and topical effects of intradermal hydrofluoric acid. Am J Emerg Med. 1998;16(5):521\u20132.","journal-title":"Am J Emerg Med"},{"issue":"4","key":"5911_CR23","doi-asserted-by":"publisher","first-page":"296","DOI":"10.5395\/rde.2014.39.4.296","volume":"39","author":"S Kasraei","year":"2014","unstructured":"Kasraei S, Rezaei-Soufi L, Heidari B, Vafaee F. Bond strength of resin cement to CO2 and Er: YAG laser-treated zirconia ceramic. Restor Dentistry Endodontics. 2014;39(4):296\u2013302.","journal-title":"Restor Dentistry Endodontics"},{"issue":"3","key":"5911_CR24","doi-asserted-by":"publisher","first-page":"195","DOI":"10.4103\/1735-3327.208762","volume":"14","author":"F Ahrari","year":"2017","unstructured":"Ahrari F, Boruziniat A, Mohammadipour HS, Alirezaei M. The effect of surface treatment with a fractional carbon dioxide laser on shear bond strength of resin cement to a lithium disilicate-based ceramic. Dent Res J. 2017;14(3):195.","journal-title":"Dent Res J"},{"issue":"17","key":"5911_CR25","doi-asserted-by":"publisher","first-page":"27822","DOI":"10.1016\/j.ceramint.2020.07.281","volume":"46","author":"B Henriques","year":"2020","unstructured":"Henriques B, Hammes N, Souza JC, \u00d6zcan M, Mesquita-Guimar\u00e3es J, Silva FS, et al. Influence of ns-Nd: YAG laser surface treatment on the tensile bond strength of zirconia to resin-matrix cements. Ceram Int. 2020;46(17):27822\u201331.","journal-title":"Ceram Int"},{"key":"5911_CR26","unstructured":"Paranhos MPG, Burnett LH Jr, Magne P. Effect of Nd: YAG laser and CO 2 laser treatment on the resin bond strength to zirconia ceramic. Quintessence Int. 2011;42(1)."},{"key":"5911_CR27","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1007\/s10103-013-1381-7","volume":"30","author":"L Liu","year":"2015","unstructured":"Liu L, Liu S, Song X, Zhu Q, Zhang W. Effect of Nd: YAG laser irradiation on surface properties and bond strength of zirconia ceramics. Lasers Med Sci. 2015;30:627\u201334.","journal-title":"Lasers Med Sci"},{"issue":"6","key":"5911_CR28","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1002\/lsm.22371","volume":"47","author":"EA Erdur","year":"2015","unstructured":"Erdur EA, Basciftci FA. Effect of Ti: Sapphire laser on shear bond strength of orthodontic brackets to ceramic surfaces. Lasers Surg Med. 2015;47(6):512\u20139.","journal-title":"Lasers Surg Med"},{"issue":"5","key":"5911_CR29","doi-asserted-by":"publisher","first-page":"1408","DOI":"10.1111\/ijac.13730","volume":"18","author":"FA Feitosa","year":"2021","unstructured":"Feitosa FA, Tribst JP, Ara\u00fajo RM, Pucci CR. Surface etching and silane heating using Er: YAG and Nd: YAG lasers in dental ceramic luted to human dentin. Int J Appl Ceram Technol. 2021;18(5):1408\u201316.","journal-title":"Int J Appl Ceram Technol"},{"issue":"11","key":"5911_CR30","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1089\/pho.2018.4475","volume":"36","author":"Y Hou","year":"2018","unstructured":"Hou Y, Shen R, Chen L, Chen Y, Jiang Y, Li J, et al. Shear bond strength of different CAD\/CAM ceramics: acid vs Er: YAG laser etching. Photomed Laser Surg. 2018;36(11):614\u201320.","journal-title":"Photomed Laser Surg"},{"issue":"2","key":"5911_CR31","first-page":"88","volume":"16","author":"AH Mirhashemi","year":"2019","unstructured":"Mirhashemi AH, Hossaini SMH, Etemadi A, Kharazifard MJ, Bahador A, Soudi A. Effect of Er: YAG and Er, Cr: YSGG lasers on ceramic bracket debonding from composite blocks. Front Dentistry. 2019;16(2):88.","journal-title":"Front Dentistry"},{"issue":"6","key":"5911_CR32","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1016\/j.prosdent.2018.07.001","volume":"121","author":"FV Martins","year":"2019","unstructured":"Martins FV, Mattos CT, Cordeiro WJ, Fonseca EM. Evaluation of zirconia surface roughness after aluminum oxide airborne-particle abrasion and the erbium-YAG, neodymium-doped YAG, or CO2 lasers: A systematic review and meta-analysis. J Prosthet Dent. 2019;121(6):895\u2013903.","journal-title":"J Prosthet Dent"},{"issue":"3","key":"5911_CR33","doi-asserted-by":"publisher","first-page":"351","DOI":"10.4012\/dmj.2014-235","volume":"34","author":"SM Unal","year":"2015","unstructured":"Unal SM, Nigiz R, Polat ZS, Usumez A. Effect of ultrashort pulsed laser on bond strength of Y-TZP zirconia ceramic to tooth surfaces. Dent Mater J. 2015;34(3):351\u20137.","journal-title":"Dent Mater J"},{"issue":"1","key":"5911_CR34","doi-asserted-by":"publisher","first-page":"45","DOI":"10.4012\/dmj.2021-036","volume":"41","author":"K Toyoda","year":"2022","unstructured":"Toyoda K, Taniguchi Y, Nakamura K, Isshi K, Kakura K, Ikeda H, et al. Effects of ytterbium laser surface treatment on the bonding of two resin cements to zirconia. Dent Mater J. 2022;41(1):45\u201353.","journal-title":"Dent Mater J"},{"key":"5911_CR35","doi-asserted-by":"publisher","first-page":"112189","DOI":"10.1016\/j.jphotobiol.2021.112189","volume":"219","author":"C Fornaini","year":"2021","unstructured":"Fornaini C, Poli F, Merigo E, Lutey A, Cucinotta A, Chevalier M, et al. Nanosecond pulsed fiber laser irradiation for enhanced zirconia crown adhesion: morphological, chemical, thermal and mechanical analysis. J Photochem Photobiol B. 2021;219:112189.","journal-title":"J Photochem Photobiol B"},{"issue":"1","key":"5911_CR36","doi-asserted-by":"publisher","first-page":"10","DOI":"10.3390\/bioengineering5010010","volume":"5","author":"C Fornaini","year":"2018","unstructured":"Fornaini C, Poli F, Merigo E, Brulat-Bouchard N, El Gamal A, Rocca J-P, et al. Disilicate dental ceramic surface Preparation by 1070 Nm fiber laser: thermal and ultrastructural analysis. Bioengineering. 2018;5(1):10.","journal-title":"Bioengineering"},{"issue":"3","key":"5911_CR37","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1089\/pho.2016.4176","volume":"35","author":"S Mutluay Unal","year":"2017","unstructured":"Mutluay Unal S, Ozkir SE, Seyfioglu Polat Z, Guven S, Asutay H. The effect of ytterbium-doped fiber laser with different parameters on physical properties of zirconia surface. Photomed Laser Surg. 2017;35(3):157\u201363.","journal-title":"Photomed Laser Surg"},{"key":"5911_CR38","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1111\/jerd.12149","volume":"27","author":"RD Paravina","year":"2015","unstructured":"Paravina RD, Ghinea R, Herrera LJ, Bona AD, Igiel C, Linninger M, et al. Color difference thresholds in dentistry. J Esthetic Restor Dentistry. 2015;27:S1\u20139.","journal-title":"J Esthetic Restor Dentistry"},{"issue":"4","key":"5911_CR39","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1111\/jerd.12107","volume":"26","author":"OT Harorl\u0131","year":"2014","unstructured":"Harorl\u0131 OT, Barutcigil \u00c7. Color recovery effect of commercial mouth rinses on a discolored composite. J Esthetic Restor Dentistry. 2014;26(4):256\u201363.","journal-title":"J Esthetic Restor Dentistry"},{"key":"5911_CR40","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1590\/S0103-64402010000300011","volume":"21","author":"CJ Soares","year":"2010","unstructured":"Soares CJ, Barbosa LM, Santana FR, Soares PBF, Mota, ASd. Silva GRd. Fracture strength of composite fixed partial denture using bovine teeth as a substitute for human teeth with or without fiber-reinforcement. Braz Dent J. 2010;21:235\u201340.","journal-title":"Braz Dent J"},{"issue":"6","key":"5911_CR41","first-page":"471","volume":"20","author":"MFF de Carvalho","year":"2018","unstructured":"de Carvalho MFF, Leij\u00f4to-Lannes ACN, Rodrigues M, Nogueira LC, Ferraz NKL, Moreira AN, et al. Viability of bovine teeth as a substrate in bond strength tests: a systematic review and meta-analysis. J Adhes Dent. 2018;20(6):471\u20139.","journal-title":"J Adhes Dent"},{"issue":"1","key":"5911_CR42","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1111\/jopr.13361","volume":"31","author":"H Abouelleil","year":"2022","unstructured":"Abouelleil H, Colon P, Jeannin C, Goujat A, Attik N, Laforest L, et al. Impact of the microstructure of CAD\/CAM blocks on the bonding strength and the bonded interface. J Prosthodont. 2022;31(1):72\u20138.","journal-title":"J Prosthodont"},{"issue":"22","key":"5911_CR43","doi-asserted-by":"publisher","first-page":"2484","DOI":"10.1080\/01694243.2020.1763543","volume":"34","author":"S \u015ei\u015fmano\u011flu","year":"2020","unstructured":"\u015ei\u015fmano\u011flu S, Turun\u00e7-O\u011fuzman R. Microshear bond strength of contemporary self-adhesive resin cements to CAD\/CAM restorative materials: effect of surface treatment and aging. J Adhes Sci Technol. 2020;34(22):2484\u201398.","journal-title":"J Adhes Sci Technol"},{"issue":"2","key":"5911_CR44","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/j.prosdent.2020.06.009","volume":"128","author":"DMD Moura","year":"2022","unstructured":"Moura DMD, Ver\u00edssimo AH, Vila-Nova TEL, Calderon PS, \u00d6zcan M, Souza ROA. Which surface treatment promotes higher bond strength for the repair of resin nanoceramics and polymer-infiltrated ceramics? A systematic review and meta-analysis. J Prosthet Dent. 2022;128(2):139\u201349.","journal-title":"J Prosthet Dent"},{"issue":"8","key":"5911_CR45","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1016\/S0109-5641(03)00019-8","volume":"19","author":"M \u00d6zcan","year":"2003","unstructured":"\u00d6zcan M, Vallittu PK. Effect of surface conditioning methods on the bond strength of Luting cement to ceramics. Dent Mater. 2003;19(8):725\u201331.","journal-title":"Dent Mater"},{"key":"5911_CR46","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1016\/j.jds.2011.05.002","volume":"6","author":"GGB Kansu","year":"2011","unstructured":"Kansu GGB. Effects of different surface treatment methods on the bond strengths of resin cements to full ceramic systems. J Dent Sci. 2011;6:134\u20139.","journal-title":"J Dent Sci"},{"issue":"5","key":"5911_CR47","doi-asserted-by":"publisher","first-page":"1164","DOI":"10.1016\/j.prosdent.2014.04.021","volume":"112","author":"TS Menees","year":"2014","unstructured":"Menees TS, Lawson NC, Beck PR, Burgess JO. Influence of particle abrasion or hydrofluoric acid etching on lithium disilicate flexural strength. J Prosthet Dent. 2014;112(5):1164\u201370.","journal-title":"J Prosthet Dent"},{"key":"5911_CR48","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1016\/j.jdsr.2024.06.001","volume":"60","author":"PM Moreira","year":"2024","unstructured":"Moreira PM, Carvalho GLM, de Castro Albuquerque R, Andr\u00e9 CB. Effect of hydrofluoric acid and self-etch ceramic primers on the flexural strength and fatigue resistance of glass ceramics: A systematic review and meta-analysis of in vitro studies. Japanese Dent Sci Rev. 2024;60:198\u2013210.","journal-title":"Japanese Dent Sci Rev"},{"issue":"1","key":"5911_CR49","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1186\/s12903-024-04044-9","volume":"24","author":"NN \u00c7ak\u0131r K\u0131l\u0131n\u00e7","year":"2024","unstructured":"\u00c7ak\u0131r K\u0131l\u0131n\u00e7 NN, Y\u0131ld\u0131z P. Do mouthwashes affect the optical properties of resin cement? BMC Oral Health. 2024;24(1):275.","journal-title":"BMC Oral Health"},{"key":"5911_CR50","doi-asserted-by":"publisher","first-page":"1497","DOI":"10.1007\/s10103-020-03219-4","volume":"36","author":"X Zhang","year":"2021","unstructured":"Zhang X, Dong H, Guo C, Zhang X, Zhang D, Wu X, et al. Effects of laser debonding treatment on the optical and mechanical properties of all-ceramic restorations. Lasers Med Sci. 2021;36:1497\u2013504.","journal-title":"Lasers Med Sci"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05911-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-05911-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05911-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,20]],"date-time":"2025-04-20T18:02:07Z","timestamp":1745172127000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-05911-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,20]]},"references-count":50,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5911"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-05911-9","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,20]]},"assertion":[{"value":"7 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study complied with all relevant institutional, national, and international ethical guidelines for the use of animals in research, including those outlined in the Basel Declaration. The animal teeth used in this study were obtained from commercially slaughtered animals that were not owned by any institution, individual, or farm; therefore, informed consent was not applicable. Since the study involved the use of animal by-products rather than direct experimentation on live animals, it was conducted in accordance with ethical regulations. Ethical approval was granted by the Ayd\u0131n Adnan Menderes University Faculty of Dentistry Non-Interventional Clinical Research Ethics Committee (Protocol No: 2024\/10, Decision No: 06). The study adhered to all ethical principles and regulatory requirements governing the use of animal-derived materials in research.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Clinical trial number"}}],"article-number":"607"}}