{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T03:11:04Z","timestamp":1794453064170,"version":"4.9.1"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,18]],"date-time":"2025-04-18T00:00:00Z","timestamp":1744934400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,4,18]],"date-time":"2025-04-18T00:00:00Z","timestamp":1744934400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"DOI":"10.1186\/s12903-025-05954-y","type":"journal-article","created":{"date-parts":[[2025,4,18]],"date-time":"2025-04-18T08:53:22Z","timestamp":1744966402000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Effect of head orientation on mandibular bone linear measurements in CBCT imaging"],"prefix":"10.1186","volume":"25","author":[{"given":"Rojin","family":"Ardalani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Azadeh","family":"Torkzadeh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roshanak","family":"Ghaffari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad javad","family":"Saeedi borujeni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,4,18]]},"reference":[{"key":"5954_CR1","doi-asserted-by":"publisher","first-page":"813768","DOI":"10.1155\/2012\/813768","volume":"2012","author":"DC Lorenzoni","year":"2012","unstructured":"Lorenzoni DC, et al. Cone-beam computed tomography and radiographs in dentistry: aspects related to radiation dose. Int J Dent. 2012;2012:813768.","journal-title":"Int J Dent"},{"issue":"1","key":"5954_CR2","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1186\/s12903-018-0523-5","volume":"18","author":"R Jacobs","year":"2018","unstructured":"Jacobs R, et al. Cone beam computed tomography in implant dentistry: recommendations for clinical use. BMC Oral Health. 2018;18(1):88.","journal-title":"BMC Oral Health"},{"issue":"Suppl 16","key":"5954_CR3","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1111\/clr.13142","volume":"29","author":"G Fokas","year":"2018","unstructured":"Fokas G, et al. Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: A systematic review. Clin Oral Implants Res. 2018;29(Suppl 16):393\u2013415.","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"5954_CR4","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1186\/s12903-015-0055-1","volume":"15","author":"W Zhang","year":"2015","unstructured":"Zhang W, Skrypczak A, Weltman R. Anterior maxilla alveolar ridge dimension and morphology measurement by cone beam computerized tomography (CBCT) for immediate implant treatment planning. BMC Oral Health. 2015;15(1):65.","journal-title":"BMC Oral Health"},{"issue":"6","key":"5954_CR5","doi-asserted-by":"publisher","first-page":"20180330","DOI":"10.1259\/dmfr.20180330","volume":"48","author":"ED Costa","year":"2019","unstructured":"Costa ED, et al. Influence of cone beam CT volume orientation on alveolar bone measurements in patients with different facial profiles. Dentomaxillofac Radiol. 2019;48(6):20180330.","journal-title":"Dentomaxillofac Radiol"},{"issue":"10","key":"5954_CR6","doi-asserted-by":"publisher","first-page":"316","DOI":"10.3390\/dj12100316","volume":"12","author":"FE Camacho-\u00c1lvarez","year":"2024","unstructured":"Camacho-\u00c1lvarez FE, et al. characteristics of the occlusal plane associated with unilateral and bilateral articular eminence inclination: a cross-sectional CBCT study. Dentistry Journal. 2024;12(10):316.","journal-title":"Dentistry Journal"},{"issue":"5","key":"5954_CR7","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1590\/0103-6440201601166","volume":"27","author":"A Shokri","year":"2016","unstructured":"Shokri A, et al. Effect of head position on maxillofacial transverse measurements made on the skull and cone beam computed tomography scans. Braz Dent J. 2016;27(5):604\u20138.","journal-title":"Braz Dent J"},{"key":"5954_CR8","doi-asserted-by":"crossref","unstructured":"Dalili Kajan, Z., et al., Comparison of height and width measurements of mandibular bone in various head orientations using cone beam computed tomography: an experimental in vitro study. Oral Radiology, 2015. 31.","DOI":"10.1007\/s11282-014-0179-z"},{"issue":"2","key":"5954_CR9","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/j.ajodo.2010.03.030","volume":"140","author":"AR El-Beialy","year":"2011","unstructured":"El-Beialy AR, et al. Accuracy and reliability of cone-beam computed tomography measurements: Influence of head orientation. Am J Orthod Dentofacial Orthop. 2011;140(2):157\u201365.","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"2","key":"5954_CR10","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1093\/ejo\/cjn088","volume":"31","author":"B Hassan","year":"2009","unstructured":"Hassan B, van der Stelt P, Sanderink G. Accuracy of three-dimensional measurements obtained from cone beam computed tomography surface-rendered images for cephalometric analysis: influence of patient scanning position. Eur J Orthod. 2009;31(2):129\u201334.","journal-title":"Eur J Orthod"},{"issue":"5","key":"5954_CR11","doi-asserted-by":"publisher","first-page":"20160180","DOI":"10.1259\/dmfr.20160180","volume":"46","author":"A Shokri","year":"2017","unstructured":"Shokri A, et al. Effect of changing the head position on accuracy of transverse measurements of the maxillofacial region made on cone beam computed tomography and conventional posterior-anterior cephalograms. Dentomaxillofac Radiol. 2017;46(5):20160180.","journal-title":"Dentomaxillofac Radiol"},{"issue":"7","key":"5954_CR12","doi-asserted-by":"publisher","first-page":"542","DOI":"10.5005\/jp-journals-10024-1719","volume":"16","author":"A Shokri","year":"2015","unstructured":"Shokri A, et al. Influence of head orientation in linear measurement for implant planning in cone beam computed tomography. J Contemp Dent Pract. 2015;16(7):542\u20136.","journal-title":"J Contemp Dent Pract"},{"issue":"2","key":"5954_CR13","doi-asserted-by":"publisher","first-page":"73","DOI":"10.5624\/isd.2015.45.2.73","volume":"45","author":"H Sabban","year":"2015","unstructured":"Sabban H, et al. Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography. Imaging Sci Dent. 2015;45(2):73\u201380.","journal-title":"Imaging Sci Dent"},{"issue":"7","key":"5954_CR14","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1016\/j.ijom.2013.03.001","volume":"42","author":"MA Visconti","year":"2013","unstructured":"Visconti MA, et al. Influence of maxillomandibular positioning in cone beam computed tomography for implant planning. Int J Oral Maxillofac Surg. 2013;42(7):880\u20136.","journal-title":"Int J Oral Maxillofac Surg"},{"key":"5954_CR15","doi-asserted-by":"publisher","first-page":"53","DOI":"10.5005\/jp-journals-10015-1883","volume":"13","author":"M Alkhader","year":"2021","unstructured":"Alkhader M, Aldawoodyeh A. Influence of cone-beam CT volume orientation on the proximity of maxillary sinus to the alveolar crest at dental implant sites. World Journal of Dentistry. 2021;13:53\u20136.","journal-title":"World Journal of Dentistry"},{"issue":"7","key":"5954_CR16","doi-asserted-by":"publisher","first-page":"20220104","DOI":"10.1259\/dmfr.20220104","volume":"51","author":"M van Eijnatten","year":"2022","unstructured":"van Eijnatten M, et al. Influence of head positioning during cone-beam CT imaging on the accuracy of virtual 3D models. Dentomaxillofac Radiol. 2022;51(7):20220104.","journal-title":"Dentomaxillofac Radiol"},{"issue":"1","key":"5954_CR17","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1016\/j.ajodo.2008.11.020","volume":"136","author":"S Baumgaertel","year":"2009","unstructured":"Baumgaertel S. Quantitative investigation of palatal bone depth and cortical bone thickness for mini-implant placement in adults. Am J Orthod Dentofacial Orthop. 2009;136(1):104\u20138.","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"4","key":"5954_CR18","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1093\/dmfr\/twae007","volume":"53","author":"ALE Carneiro","year":"2024","unstructured":"Carneiro ALE, et al. Accuracy of linear measurements for implant planning based on low-dose cone beam CT protocols: a systematic review and meta-analysis. Dentomaxillofac Radiol. 2024;53(4):207\u201321.","journal-title":"Dentomaxillofac Radiol"},{"issue":"3","key":"5954_CR19","first-page":"142","volume":"13","author":"S Shetty","year":"2013","unstructured":"Shetty S, et al. Occlusal plane location in edentulous patients: a review. J Indian Prosthodont Soc. 2013;13(3):142\u20138.","journal-title":"J Indian Prosthodont Soc"},{"issue":"1","key":"5954_CR20","doi-asserted-by":"publisher","first-page":"20140282","DOI":"10.1259\/dmfr.20140282","volume":"44","author":"SD Kapila","year":"2015","unstructured":"Kapila SD, Nervina JM. CBCT in orthodontics: assessment of treatment outcomes and indications for its use. Dentomaxillofac Radiol. 2015;44(1):20140282.","journal-title":"Dentomaxillofac Radiol"},{"issue":"6","key":"5954_CR21","doi-asserted-by":"publisher","first-page":"20230072","DOI":"10.1259\/dmfr.20230072","volume":"52","author":"S El Bachaoui","year":"2023","unstructured":"El Bachaoui S, et al. The impact of CBCT-head tilting on 3D condylar segmentation reproducibility. Dentomaxillofac Radiol. 2023;52(6):20230072.","journal-title":"Dentomaxillofac Radiol"},{"issue":"1","key":"5954_CR22","first-page":"54","volume":"13","author":"M Alkhader","year":"2022","unstructured":"Alkhader M, Aldawoodyeh A. Influence of cone-beam CT volume orientation on the proximity of maxillary sinus to the alveolar crest at dental implant sites. World. 2022;13(1):54.","journal-title":"World"},{"key":"5954_CR23","unstructured":"Li, M., et al., Precision linear measurement using cone beam ct in dental implants: An experimental study. Chinese Journal of Radiology, 2016: p. 52\u201356."},{"issue":"7","key":"5954_CR24","doi-asserted-by":"publisher","first-page":"20220104","DOI":"10.1259\/dmfr.20220104","volume":"51","author":"M van Eijnatten","year":"2022","unstructured":"van Eijnatten M, et al. Influence of head positioning during cone-beam CT imaging on the accuracy of virtual 3D models. Dentomaxillofacial Radiology. 2022;51(7):20220104.","journal-title":"Dentomaxillofacial Radiology"},{"issue":"3","key":"5954_CR25","first-page":"181","volume":"18","author":"S Adibi","year":"2017","unstructured":"Adibi S, et al. Influence of head position on the CBCT accuracy in assessment of the proximity of the root apices to the inferior alveolar canal. J Dent. 2017;18(3):181.","journal-title":"J Dent"},{"issue":"4","key":"5954_CR26","doi-asserted-by":"publisher","first-page":"257","DOI":"10.5624\/isd.2014.44.4.257","volume":"44","author":"S Nikneshan","year":"2014","unstructured":"Nikneshan S, et al. Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles. Imaging science in dentistry. 2014;44(4):257\u201362.","journal-title":"Imaging science in dentistry"}],"updated-by":[{"DOI":"10.1186\/s12903-025-06409-0","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2025,6,17]],"date-time":"2025-06-17T00:00:00Z","timestamp":1750118400000}}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05954-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-05954-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-05954-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,17]],"date-time":"2025-06-17T12:56:07Z","timestamp":1750164967000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-05954-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,18]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5954"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-05954-y","relation":{"correction":[{"id-type":"doi","id":"10.1186\/s12903-025-06409-0","asserted-by":"object"}]},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,18]]},"assertion":[{"value":"14 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 June 2025","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1186\/s12903-025-06409-0","URL":"https:\/\/doi.org\/10.1186\/s12903-025-06409-0","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Initially, the research protocol underwent review and approval by the Ethics Committee of Islamic Azad University, Isfahan (Khorasgan) Branch, with the ethics code IR.IAU.KHUISF.REC.1403.079.As this study was conducted on dry human mandibles, it does not involve human participants, and informed consent to participate is \u2018not applicable.\u2019","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"This study complies with the ethical principles of the Declaration of Helsinki. However, as it is an in vitro study conducted on dry human mandibles that were already available in the Department of Anatomy and Basic Sciences, it does not involve human participants or identifiable data.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with the Helsinki declaration"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interest"}}],"article-number":"584"}}