{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:45:37Z","timestamp":1790815537988,"version":"4.1.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,26]],"date-time":"2025-04-26T00:00:00Z","timestamp":1745625600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,26]],"date-time":"2025-04-26T00:00:00Z","timestamp":1745625600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Sivas Cumhuriyet University Scientific Research Projects","award":["D\u0130\u015e-2023-309"],"award-info":[{"award-number":["D\u0130\u015e-2023-309"]}]},{"name":"Sivas Cumhuriyet University Scientific Research Projects","award":["D\u0130\u015e-2023-309"],"award-info":[{"award-number":["D\u0130\u015e-2023-309"]}]},{"name":"Sivas Cumhuriyet University Scientific Research Projects","award":["D\u0130\u015e-2023-309"],"award-info":[{"award-number":["D\u0130\u015e-2023-309"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The aim of this study was to compare fracture resistance after thermomechanical ageing of prosthetic substructure materials with different connector designs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Three different prosthetic substructure materials were used in this study: (1) GroupZir:\n                      <jats:bold>(<\/jats:bold>\n                      Zirconia, Fusion ceram, Turkey), (2)GroupPEEK (PEEK, Whitepeaks, CopraPeek, Essen, Germany), (3)GroupFRC (Fibre-reinforced composite, Trinia, Bicon Implant, Rep. of Ireland). A total of 72 implant-supported prosthesis triangular, square, and oval connector designs were created between 2nd premolar and mandibular 2nd molar teeth. After adhesion to the implant abutments with resin cement (Pentron breeze, Kerr), the samples were applied with dynamic loading and thermomechanical ageing (120,000 cycles,120\u00a0N,5\u201355\u00a0\u00b0C). Fracture resistance values were obtained with a universal test device and SEM images were analysed. The analyses were performed with Two-Way ANOVA and the Tukey test (SPSS 23.00).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Both the material and the connector type were found to affect the fracture resistance (F\u2009=\u20098.354,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05). The highest fracture resistance value was obtained from the triangular shape in GroupZir(3200\u2009\u00b1\u200991.05) and the lowest from the oval connector design of GroupPEEK material (2410\u2009\u00b1\u2009157.23). Statistically significant differences were determined in the different connector designs of GroupZir(\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05). In the comparisons made according to connector design, a significant difference was obtained between GroupZir and GroupPEEK and between GroupZir and GroupFRC. Deformations were observed in the fracture pattern of the Group Zir samples and deformations in the form of rupture were seen in the GroupPEEK and GroupFRC material samples.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The study results demonstrated that the fracture resistance of zirconia, PEEK, and FRC restorations over 3-unit implants with different connectors is affected by connector design. All the materials were seen to be comparable in respect of the forces formed in chewing dynamics.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-025-06033-y","type":"journal-article","created":{"date-parts":[[2025,4,26]],"date-time":"2025-04-26T09:54:30Z","timestamp":1745661270000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Comparison of fracture resistance of implant-supported fixed prothesis substructure materials with different cross-sectional geometry"],"prefix":"10.1186","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6414-3647","authenticated-orcid":false,"given":"O\u011fuzhan","family":"Y\u0131lmaz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ay\u015feg\u00fcl","family":"G\u00f6ze Sayg\u0131n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3257-276X","authenticated-orcid":false,"given":"Giray","family":"Bolay\u0131r","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,4,26]]},"reference":[{"issue":"2","key":"6033_CR1","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1111\/joor.12575","volume":"45","author":"CWP Pol","year":"2018","unstructured":"Pol CWP, Raghoebar GM, Kerdijk W, Boven GC, Cune MS, Meijer HJA. A systematic review and meta-analysis of 3\u2010unit fixed dental prostheses: are the results of 2 abutment implants comparable to the results of 2 abutment teeth? J Oral Rehabil. 2018;45(2):147\u201360.","journal-title":"J Oral Rehabil"},{"issue":"6","key":"6033_CR2","doi-asserted-by":"publisher","first-page":"1000","DOI":"10.1016\/j.prosdent.2017.06.001","volume":"119","author":"JCC Yuan","year":"2018","unstructured":"Yuan JCC, Bar\u00e3o VAR, Wee AG, Alfaro MF, Afshari FS, Sukotjo C. Effect of brushing and thermocycling on the shade and surface roughness of CAD-CAM ceramic restorations. J Prosthet Dent. 2018;119(6):1000\u20136.","journal-title":"J Prosthet Dent"},{"issue":"6","key":"6033_CR3","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1080\/10255842.2017.1287905","volume":"20","author":"VE de Souza Batista","year":"2017","unstructured":"de Souza Batista VE, Verri FR, Almeida DA, de Santiago Junior F, Lemos JF, Pellizzer CAA. Finite element analysis of implant-supported prosthesis with Pontic and cantilever in the posterior maxilla. Comput Methods Biomech Biomed Engin. 2017;20(6):663\u201370.","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"4","key":"6033_CR4","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.dental.2017.01.003","volume":"33","author":"V Preis","year":"2017","unstructured":"Preis V, Hahnel S, Behr M, Bein L, Rosentritt M. In-vitro fatigue and fracture testing of CAD\/CAM-materials in implant-supported molar crowns. Dent Mater. 2017;33(4):427\u201333.","journal-title":"Dent Mater"},{"issue":"6","key":"6033_CR5","doi-asserted-by":"publisher","first-page":"486","DOI":"10.4047\/jap.2017.9.6.486","volume":"9","author":"H Lambert","year":"2017","unstructured":"Lambert H, Durand JC, Jacquot B, Fages M. Dental biomaterials for chairside CAD\/CAM: state of the Art. J Adv Prosthodont. 2017;9(6):486\u201395.","journal-title":"J Adv Prosthodont"},{"issue":"11","key":"6033_CR6","doi-asserted-by":"publisher","first-page":"249","DOI":"10.3390\/dj11110249.)","volume":"11","author":"C Abad-Coronel","year":"2023","unstructured":"Abad-Coronel C, V\u00e9lez Chimbo D, Lup\u00fa B, Pacurucu M, F\u00e1rez MV, Fajardo JI. Comparative analysis of the structural weights of fixed prostheses of zirconium dioxide, metal ceramic, PMMA and 3DPP printing resin\u2014mechanical implications. Dent J. 2023;11(11):249. https:\/\/doi.org\/10.3390\/dj11110249.).","journal-title":"Dent J"},{"issue":"9","key":"6033_CR7","doi-asserted-by":"publisher","first-page":"1342","DOI":"10.1016\/j.dental.2018.06.024","volume":"34","author":"AM Dal Piva","year":"2018","unstructured":"Dal Piva AM, de O, Tribst JPM, Borges ALS, e Souza RO, de Bottino A. CAD-FEA modeling and analysis of different full crown monolithic restorations. Dent Mater. 2018;34(9):1342\u201350.","journal-title":"Dent Mater"},{"key":"6033_CR8","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.jdent.2018.04.012","volume":"73","author":"C L\u00f3pez-Su\u00e1rez","year":"2018","unstructured":"L\u00f3pez-Su\u00e1rez C, Castillo-Oyag\u00fce R, Rodr\u00edguez-Alonso V, Lynch CD, Su\u00e1rez-Garc\u00eda MJ. Fracture load of metal-ceramic, monolithic, and bi-layered zirconia-based posterior fixed dental prostheses after thermo-mechanical cycling. J Dent. 2018;73:97\u2013104.","journal-title":"J Dent"},{"issue":"4","key":"6033_CR9","doi-asserted-by":"publisher","first-page":"959","DOI":"10.3390\/ma14040959","volume":"14","author":"V Rodr\u00edguez","year":"2021","unstructured":"Rodr\u00edguez V, Tobar C, L\u00f3pez-Su\u00e1rez C, Pel\u00e1ez J, Su\u00e1rez MJ. Fracture load of metal, zirconia and polyetheretherketone posterior CAD-CAM milled fixed partial denture frameworks. Mater (Basel). 2021;14(4):959.","journal-title":"Mater (Basel)"},{"key":"6033_CR10","doi-asserted-by":"publisher","first-page":"179","DOI":"10.5005\/jp-journals-10024-3077","volume":"22","author":"SP Shrivastava","year":"2021","unstructured":"Shrivastava SP, Dable R, Raj APN, Mutneja P, Srivastava SB, Haque M. Comparison of mechanical properties of PEEK and PMMA: an in vitro study. J Contemp Dent Pr. 2021;22:179\u201383.","journal-title":"J Contemp Dent Pr"},{"key":"6033_CR11","doi-asserted-by":"crossref","unstructured":"Najeeb S, Zafar MS, Khurshid Z, Siddiqui F. Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J Prosthodontic Res. 2016.","DOI":"10.1016\/j.jpor.2015.10.001"},{"key":"6033_CR12","doi-asserted-by":"publisher","first-page":"381759","DOI":"10.1155\/2015\/381759","volume":"2015","author":"S Najeeb","year":"2015","unstructured":"Najeeb S, Khurshid Z, Matinlinna JP, Siddiqui F, Nassani MZ, Baroudi K. Nanomodified peek dental implants: bioactive composites and surface modification\u2014A review. Int J Dent. 2015;2015:381759.","journal-title":"Int J Dent"},{"key":"6033_CR13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12903-020-01202-7","volume":"20","author":"I Papathanasiou","year":"2020","unstructured":"Papathanasiou I, Kamposiora P, Papavasiliou G, Ferrari M. The use of PEEK in digital prosthodontics: A narrative review. BMC Oral Health. 2020;20:1\u201311.","journal-title":"BMC Oral Health"},{"issue":"2","key":"6033_CR14","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1016\/j.jpor.2017.10.002","volume":"62","author":"A Passaretti","year":"2018","unstructured":"Passaretti A, Petroni G, Miracolo G, Savoia V, Perpetuini A, Cicconetti A. Metal free, full arch, fixed prosthesis for edentulous mandible rehabilitation on four implants. J Prosthodont Res. 2018;62(2):264\u20137.","journal-title":"J Prosthodont Res"},{"issue":"8","key":"6033_CR15","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1016\/j.dental.2020.04.012","volume":"36","author":"N Suzaki","year":"2020","unstructured":"Suzaki N, Yamaguchi S, Hirose N, Tanaka R, Takahashi Y, Imazato S, et al. Evaluation of physical properties of fiber-reinforced composite resin. Dent Mater. 2020;36(8):987\u201396.","journal-title":"Dent Mater"},{"key":"6033_CR16","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/j.jmbbm.2018.05.029","volume":"85","author":"GKR Pereira","year":"2018","unstructured":"Pereira GKR, Guilardi LF, Dapieve KS, Kleverlaan CJ, Rippe MP, Valandro LF. Mechanical reliability, fatigue strength and survival analysis of new polycrystalline translucent zirconia ceramics for monolithic restorations. J Mech Behav Biomed Mater. 2018;85:57\u201365.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"6","key":"6033_CR17","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.1111\/cid.12844","volume":"21","author":"B Yilmaz","year":"2019","unstructured":"Yilmaz B, Batak B, Seghi RR. Failure analysis of high performance polymers and new generation cubic zirconia used for implant-supported fixed, cantilevered prostheses. Clin Implant Dent Relat Res. 2019;21(6):1132\u20139.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"1","key":"6033_CR18","doi-asserted-by":"publisher","first-page":"34","DOI":"10.3390\/ceramics5010004","volume":"5","author":"LHJ Alberto","year":"2022","unstructured":"Alberto LHJ, Kalluri L, Esquivel-Upshaw JF, Duan Y. Three-dimensional finite element analysis of different connector designs for all-ceramic implant-supported fixed dental prostheses. Ceramics. 2022;5(1):34\u201343.","journal-title":"Ceramics"},{"key":"6033_CR19","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1007\/s00784-017-2142-y","volume":"22","author":"S Miura","year":"2018","unstructured":"Miura S, Kasahara S, Yamauchi S, Okuyama Y, Izumida A, Aida J, et al. Clinical evaluation of zirconia-based all-ceramic single crowns: an up to 12-year retrospective cohort study. Clin Oral Investig. 2018;22:697\u2013706.","journal-title":"Clin Oral Investig"},{"issue":"6","key":"6033_CR20","doi-asserted-by":"publisher","first-page":"2413","DOI":"10.3390\/ma16062413","volume":"16","author":"F Ferrini","year":"2023","unstructured":"Ferrini F, Paolone G, Di Domenico GL, Pagani N, Gherlone EF. SEM evaluation of the marginal accuracy of zirconia, lithium disilicate, and composite single crowns created by CAD\/CAM method: comparative analysis of different materials. Mater (Basel). 2023;16(6):2413.","journal-title":"Mater (Basel)"},{"issue":"11","key":"6033_CR21","doi-asserted-by":"publisher","first-page":"2334","DOI":"10.3390\/sym14112334","volume":"14","author":"LHJ Alberto","year":"2022","unstructured":"Alberto LHJ, Kalluri L, Esquivel-Upshaw JF, Duan Y. Finite element analysis of an implant-supported FDP with different connector heights. Symmetry (Basel). 2022;14(11):2334.","journal-title":"Symmetry (Basel)"},{"key":"6033_CR22","doi-asserted-by":"crossref","unstructured":"Ats\u00fc SS, Aksan E, Bulut AC. Fracture resistance of Titanium, zirconia, and ceramic-Reinforced polyetheretherketone implant abutments supporting CAD\/CAM monolithic Lithium disilicate ceramic crowns after aging. Int J Oral Maxillofac Implants. 2019;34(3).","DOI":"10.11607\/jomi.7036"},{"issue":"6","key":"6033_CR23","first-page":"400","volume":"13","author":"V Nazari","year":"2016","unstructured":"Nazari V, Ghodsi S, Alikhasi M, Sahebi M, Shamshiri AR. Fracture strength of three-unit implant supported fixed partial dentures with excessive crown height fabricated from different materials. J Dent (Tehran). 2016;13(6):400.","journal-title":"J Dent (Tehran)"},{"issue":"1","key":"6033_CR24","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.prosdent.2018.05.003","volume":"121","author":"T Niem","year":"2019","unstructured":"Niem T, Youssef N, W\u00f6stmann B. Energy dissipation capacities of CAD-CAM restorative materials: A comparative evaluation of resilience and toughness. J Prosthet Dent. 2019;121(1):101\u20139.","journal-title":"J Prosthet Dent"},{"issue":"9","key":"6033_CR25","doi-asserted-by":"publisher","first-page":"5969","DOI":"10.1007\/s00784-022-04623-6","volume":"26","author":"F Demirci","year":"2022","unstructured":"Demirci F, Bahce E, Baran MC. Mechanical analysis of three-unit metal-free fixed dental prostheses produced in different materials with CAD\/CAM technology. Clin Oral Investig. 2022;26(9):5969\u201378.","journal-title":"Clin Oral Investig"},{"issue":"6","key":"6033_CR26","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1016\/j.prosdent.2022.10.008","volume":"128","author":"RL Luft","year":"2022","unstructured":"Luft RL, da Rosa LS, Machado PS, Valandro LF, Sarkis-Onofre R, Pereira GKR, et al. Influence of connector cross-sectional geometry on the load-bearing capacity under fatigue of implant-supported zirconia fixed partial prosthesis. J Prosthet Dent. 2022;128(6):1335\u2013e1.","journal-title":"J Prosthet Dent"},{"issue":"20","key":"6033_CR27","doi-asserted-by":"publisher","first-page":"3469","DOI":"10.3390\/polym13203469","volume":"13","author":"F Hensel","year":"2021","unstructured":"Hensel F, Koenig A, Doerfler HM, Fuchs F, Rosentritt M, Hahnel S. CAD\/CAM resin-based composites for use in long-term temporary fixed dental prostheses. Polym (Basel). 2021;13(20):3469.","journal-title":"Polym (Basel)"},{"issue":"2","key":"6033_CR28","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1016\/j.prosdent.2021.09.027","volume":"130","author":"MA Attia","year":"2023","unstructured":"Attia MA, Shokry TE. Effect of dynamic loading on fracture resistance of gradient zirconia fixed partial denture frameworks. J Prosthet Dent. 2023;130(2):242\u20139.","journal-title":"J Prosthet Dent"},{"issue":"4","key":"6033_CR29","first-page":"179","volume":"37","author":"DJH Mahmood","year":"2013","unstructured":"Mahmood DJH, Linderoth EH, Von Steyern PV, Wennerberg A. Fracture strength of all-ceramic (Y-TZP) three- and four-unit fixed dental prostheses with different connector design and production history. Swed Dent J. 2013;37(4):179\u201387.","journal-title":"Swed Dent J"},{"issue":"1","key":"6033_CR30","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.jmbbm.2010.09.011","volume":"4","author":"E Erkmen","year":"2011","unstructured":"Erkmen E, Meri\u00e7 G, Kurt A, Tun\u00e7 Y, Eser A. Biomechanical comparison of implant retained fixed partial dentures with fiber reinforced composite versus conventional metal frameworks: a 3D FEA study. J Mech Behav Biomed Mater. 2011;4(1):107\u201316.","journal-title":"J Mech Behav Biomed Mater"},{"key":"6033_CR31","first-page":"2","volume":"1","author":"R Ewers","year":"2017","unstructured":"Ewers R, Perpetuini P, Morgan VJ, Marincola M, Wu R, Seemann R. TRINIATM\u2014Metal-free restorations. Implants. 2017;1:2\u20137.","journal-title":"Implants"},{"key":"6033_CR32","doi-asserted-by":"publisher","first-page":"2493","DOI":"10.1007\/s00784-016-1777-4","volume":"20","author":"S Taufall","year":"2016","unstructured":"Taufall S, Eichberger M, Schmidlin PR, Stawarczyk B. Fracture load and failure types of different veneered polyetheretherketone fixed dental prostheses. Clin Oral Investig. 2016;20:2493\u2013500.","journal-title":"Clin Oral Investig"},{"issue":"3","key":"6033_CR33","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1016\/j.prosdent.2016.08.009","volume":"117","author":"P Zoidis","year":"2017","unstructured":"Zoidis P, Bakiri E, Polyzois G. Using modified polyetheretherketone (PEEK) as an alternative material for endocrown restorations: A short-term clinical report. J Prosthet Dent. 2017;117(3):335\u20139.","journal-title":"J Prosthet Dent"},{"issue":"3","key":"6033_CR34","first-page":"158","volume":"9","author":"M Tsumita","year":"2020","unstructured":"Tsumita M, Kihara T, Shigeta Y, Shigemoto S, Kokubo Y, Ikawa T, et al. Fracture strength of dual-structured CAD\/CAM restoration with fiber-reinforced composite resin. \u65e5\u672c\u30c7\u30b8\u30bf\u30eb\u6b6f\u79d1\u5b66\u4f1a\u8a8c. 2020;9(3):158\u201364.","journal-title":"\u65e5\u672c\u30c7\u30b8\u30bf\u30eb\u6b6f\u79d1\u5b66\u4f1a\u8a8c"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06033-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-06033-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06033-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,26]],"date-time":"2025-04-26T09:54:32Z","timestamp":1745661272000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-06033-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,26]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6033"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-06033-y","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-5947187\/v1","asserted-by":"object"}]},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,26]]},"assertion":[{"value":"2 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"645"}}