{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T17:45:41Z","timestamp":1793036741833,"version":"4.5.0"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,5]],"date-time":"2025-07-05T00:00:00Z","timestamp":1751673600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,5]],"date-time":"2025-07-05T00:00:00Z","timestamp":1751673600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002842","name":"Chiang Mai University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002842","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Traditional and innovative materials are widely used in dentistry; however, the mechanical behavior of hybrid custom implant abutments, particularly stress distribution in various material combinations, is not fully understood. The study aims to evaluate the mechanical behavior of hybrid custom implant abutments made from various material combinations, including their effects on von Mises stress, maximum and minimum principal stresses, and deformation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Two 3-dimensional (3D) models were constructed: a 1.5\u00a0mm subcrestal as the test and an equicrestal model as the control. The subcrestal model explored seven materials (Zirconia, Titanium, Lithium Disilicate, Polymer-Infiltrated Ceramic Networks, PEEK, PEEK reinforced with carbon fiber and reinforced with glass fiber) in various abutment and crown combinations. Each model included an implant, titanium base abutment, abutment screw, a custom abutment, a zirconia crown, and bone. A 200\u00a0N load was applied, and a Finite Element Analysis (FEA) assessed peak, volume average, and distribution of von Mises stress and principal stress.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The titanium base (Tibase) exhibited the highest peak and volume average von Mises stresses (306\u2013429\u00a0MPa), followed by the custom abutment (40\u201395\u00a0MPa) and crown (46\u201381\u00a0MPa). Material changes significantly impacted stress distribution in the Tibase and customized abutments. PICN, Zirconia, Titanium, and Lithium Disilicate abutments showed peak principal stresses between 77 and 85\u00a0MPa, while PEEK variants reduced stress in the custom abutment (35\u201366\u00a0MPa) but increased it in the Ti-base (356\u2013405\u00a0MPa). PEEK also increased minimum principal stresses in the Ti-base (-400 to -600\u00a0MPa).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Abutment materials have a greater impact on stress outcomes compared to crown materials. Abutments with high Young\u2019s modulus contribute to increased core system stiffness in hybrid custom abutment complexes. Choosing abutment materials with a high Young\u2019s modulus for hybrid custom implant abutments is essential to optimize stress distribution and enhance the stability of the implant system.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s12903-025-06445-w","type":"journal-article","created":{"date-parts":[[2025,7,5]],"date-time":"2025-07-05T04:28:43Z","timestamp":1751689723000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Mechanical behavior of hybrid custom implant abutments with various crown materials: a 3D finite element analysis"],"prefix":"10.1186","volume":"25","author":[{"given":"Pongsakorn","family":"Poovarodom","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guilherme Faria","family":"Moura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabio Antonio Piola","family":"Rizzante","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chaiy","family":"Rungsiyakull","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jarupol","family":"Suriyawanakul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pimduen","family":"Rungsiyakull","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,5]]},"reference":[{"issue":"1","key":"6445_CR1","doi-asserted-by":"publisher","first-page":"44","DOI":"10.4012\/dmj.28.44","volume":"28","author":"T Miyazaki","year":"2009","unstructured":"Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y. A review of dental CAD\/CAM: current status and future perspectives from 20 years of experience. Dent Mater J. 2009;28(1):44\u201356.","journal-title":"Dent Mater J"},{"key":"6445_CR2","doi-asserted-by":"crossref","unstructured":"Guilherme NM, Chung K-H, Flinn BD, Zheng C, Raigrodski AJ. Assessment of reliability of CAD-CAM tooth-colored implant\u00a0custom abutments. Journal of Prosthetic Dentistry.2016;116(2):206\u2013\u200913.","DOI":"10.1016\/j.prosdent.2015.12.015"},{"issue":"2","key":"6445_CR3","doi-asserted-by":"publisher","first-page":"187","DOI":"10.4012\/dmj.2022-165","volume":"42","author":"R Takano","year":"2023","unstructured":"Takano R, Honda J, Kobayashi T, Kubochi K, Takata H, Komine F. Fracture strength of implant-supported hybrid abutment crowns in premolar region fabricated using different restorative CAD\/CAM materials. Dent Mater J. 2023;42(2):187\u201392.","journal-title":"Dent Mater J"},{"issue":"4","key":"6445_CR4","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1111\/jerd.12370","volume":"30","author":"JC Facenda","year":"2018","unstructured":"Facenda JC, Borba M, Corazza PH. A literature review on the new polymer-infiltrated ceramic-network material (PICN). J Esthet Restor Dent. 2018;30(4):281\u20136.","journal-title":"J Esthet Restor Dent"},{"issue":"3","key":"6445_CR5","doi-asserted-by":"publisher","first-page":"450","DOI":"10.2186\/jpr.JPR_D_22_00115","volume":"67","author":"T Graf","year":"2023","unstructured":"Graf T, Schweiger J, Stimmelmayr M, Erdelt K, Schubert O, G\u00fcth JF. Influence of monolithic restorative materials on the implant-abutment interface of hybrid abutment crowns: an in vitro investigation. J Prosthodont Res. 2023;67(3):450\u20139.","journal-title":"J Prosthodont Res"},{"issue":"6","key":"6445_CR6","doi-asserted-by":"publisher","first-page":"1272","DOI":"10.11607\/jomi.3975","volume":"30","author":"T Joda","year":"2015","unstructured":"Joda T, B\u00fcrki A, Bethge S, Br\u00e4gger U, Zysset P. Stiffness, strength, and failure modes of implant-supported monolithic lithium disilicate crowns: influence of titanium and zirconia abutments. Int J Oral Maxillofac Implants. 2015;30(6):1272\u20139.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"2","key":"6445_CR7","doi-asserted-by":"publisher","first-page":"33","DOI":"10.3390\/jfb13020033","volume":"13","author":"S Suphangul","year":"2022","unstructured":"Suphangul S, Rokaya D, Kanchanasobhana C, Rungsiyakull P, Chaijareenont P. PEEK biomaterial in Long-Term provisional implant restorations: A review. J Funct Biomaterials. 2022;13(2):33.","journal-title":"J Funct Biomaterials"},{"issue":"3","key":"6445_CR8","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1016\/j.prosdent.2023.06.031","volume":"130","author":"P Poovarodom","year":"2023","unstructured":"Poovarodom P, Rungsiyakull C, Suriyawanakul J, Li Q, Sasaki K, Yoda N, Rungsiyakull P. Effect of gingival height of a titanium base on the Biomechanical behavior of 2-piece custom implant abutments: A 3-dimensional nonlinear finite element study. J Prosthet Dent. 2023;130(3):380.e1-.e9","journal-title":"J Prosthet Dent"},{"issue":"2","key":"6445_CR9","doi-asserted-by":"publisher","first-page":"278","DOI":"10.2186\/jpr.JPR_D_22_00054","volume":"67","author":"P Poovarodom","year":"2023","unstructured":"Poovarodom P, Rungsiyakull C, Suriyawanakul J, Li Q, Sasaki K, Yoda N, Rungsiyakull P. Effect of implant placement depth on bone remodeling on implant-supported single zirconia abutment crown: A 3D finite element study. J Prosthodont Res. 2023;67(2):278\u201387.","journal-title":"J Prosthodont Res"},{"issue":"5","key":"6445_CR10","doi-asserted-by":"publisher","first-page":"e2","DOI":"10.1111\/jopr.13530","volume":"31","author":"S Pumnil","year":"2022","unstructured":"Pumnil S, Rungsiyakull P, Rungsiyakull C, Elsaka S. Effect of different customized abutment types on stress distribution in Implant-Supported single crown: A 3D finite element analysis. J Prosthodont. 2022;31(5):e2\u201311.","journal-title":"J Prosthodont"},{"issue":"16","key":"6445_CR11","doi-asserted-by":"publisher","first-page":"4812","DOI":"10.3390\/jcm11164812","volume":"11","author":"A Di Fiore","year":"2022","unstructured":"Di Fiore A, Montagner M, Sivolella S, Stellini E, Yilmaz B, Brunello G. Peri-Implant bone loss and overload: A systematic review focusing on occlusal analysis through digital and analogic methods. J Clin Med. 2022;11(16):4812.","journal-title":"J Clin Med"},{"issue":"1","key":"6445_CR12","doi-asserted-by":"publisher","first-page":"15867","DOI":"10.1038\/s41598-024-66807-2","volume":"14","author":"P Poovarodom","year":"2024","unstructured":"Poovarodom P, Rungsiyakull C, Suriyawanakul J, Li Q, Sasaki K, Yoda N, Rungsiyakull P. Multi-objective optimization of custom implant abutment design for enhanced bone remodeling in single-crown implants using 3D finite element analysis. Sci Rep. 2024;14(1):15867.","journal-title":"Sci Rep"},{"issue":"3","key":"6445_CR13","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1016\/j.prosdent.2017.03.008","volume":"119","author":"N Kaleli","year":"2018","unstructured":"Kaleli N, Sarac D, K\u00fcl\u00fcnk S, \u00d6zt\u00fcrk \u00d6. Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: A three-dimensional finite element analysis study. J Prosthet Dent. 2018;119(3):437\u201345.","journal-title":"J Prosthet Dent"},{"issue":"1","key":"6445_CR14","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1186\/s12903-023-03100-0","volume":"23","author":"J Lin","year":"2023","unstructured":"Lin J, Cai P, Zhuo Y, Lin L, Zheng Z. Effect of abutment design on fracture resistance of resin-matrix ceramic crowns for dental implant restoration: an in vitro study. BMC Oral Health. 2023;23(1):410.","journal-title":"BMC Oral Health"},{"issue":"6","key":"6445_CR15","doi-asserted-by":"publisher","first-page":"671","DOI":"10.11607\/ijp.6649","volume":"33","author":"A Paratelli","year":"2020","unstructured":"Paratelli A, Perrone G, Ortega R, G\u00f3mez-Polo M. Polyetheretherketone in implant prosthodontics: A scoping review. Int J Prosthodont. 2020;33(6):671\u20139.","journal-title":"Int J Prosthodont"},{"issue":"12","key":"6445_CR16","doi-asserted-by":"publisher","first-page":"2065","DOI":"10.1902\/jop.2009.090274","volume":"80","author":"FP Nothdurft","year":"2009","unstructured":"Nothdurft FP, Pospiech PR. Zirconium dioxide implant abutments for posterior single-tooth replacement: first results. J Periodontol. 2009;80(12):2065\u201372.","journal-title":"J Periodontol"},{"issue":"9 Suppl 2","key":"6445_CR17","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/j.joms.2005.05.161","volume":"63","author":"S Holst","year":"2005","unstructured":"Holst S, Blatz MB, Hegenbarth E, Wichmann M, Eitner S. Prosthodontic considerations for predictable single-implant esthetics in the anterior maxilla. J Oral Maxillofacial Surgery: Official J Am Association Oral Maxillofacial Surg. 2005;63(9 Suppl 2):89\u201396.","journal-title":"J Oral Maxillofacial Surgery: Official J Am Association Oral Maxillofacial Surg"},{"issue":"5","key":"6445_CR18","doi-asserted-by":"publisher","first-page":"e0285421","DOI":"10.1371\/journal.pone.0285421","volume":"18","author":"E Epifania","year":"2023","unstructured":"Epifania E, di Lauro AE, Ausiello P, Mancone A, Garcia-Godoy F, Mendes Tribst JP. Effect of crown stiffness and prosthetic screw absence on the stress distribution in implant-supported restoration: A 3D finite element analysis. PLoS ONE. 2023;18(5):e0285421.","journal-title":"PLoS ONE"},{"issue":"1","key":"6445_CR19","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1186\/s12903-024-04328-0","volume":"24","author":"G Deste G\u00f6kay","year":"2024","unstructured":"Deste G\u00f6kay G, Oyar P, G\u00f6k\u00e7imen G, Durkan R. Static and dynamic stress analysis of different crown materials on a titanium base abutment in an implant-supported single crown: a 3D finite element analysis. BMC Oral Health. 2024;24(1):545.","journal-title":"BMC Oral Health"},{"issue":"1","key":"6445_CR20","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1016\/j.dental.2022.12.001","volume":"39","author":"P Ausiello","year":"2023","unstructured":"Ausiello P, Di Lauro AE, Tribst JPM, Watts DC. Stress distribution in resin-based CAD-CAM implant-supported crowns. Dent Mater. 2023;39(1):114\u201322.","journal-title":"Dent Mater"},{"issue":"5","key":"6445_CR21","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1080\/10255842.2020.1836168","volume":"24","author":"P Ausiello","year":"2021","unstructured":"Ausiello P, Ciaramella S, De Benedictis A, Lanzotti A, Tribst JPM, Watts DC. The use of different adhesive filling material and mass combinations to restore class II cavities under loading and shrinkage effects: a 3D-FEA. Comput Methods Biomech Biomed Engin. 2021;24(5):485\u201395.","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"2","key":"6445_CR22","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1007\/s10237-014-0612-6","volume":"14","author":"C Rungsiyakull","year":"2015","unstructured":"Rungsiyakull C, Chen J, Rungsiyakull P, Li W, Swain M, Li Q. Bone\u2019s responses to different designs of implant-supported fixed partial dentures. Biomech Model Mechanobiol. 2015;14(2):403\u201311.","journal-title":"Biomech Model Mechanobiol"},{"issue":"4","key":"6445_CR23","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/j.jpor.2019.10.003","volume":"64","author":"T Kitagawa","year":"2020","unstructured":"Kitagawa T, Tanimoto Y, Iida T, Murakami H. Effects of material and coefficient of friction on taper joint dental implants. J Prosthodont Res. 2020;64(4):359\u201367.","journal-title":"J Prosthodont Res"},{"issue":"27","key":"6445_CR24","doi-asserted-by":"publisher","first-page":"7196","DOI":"10.1016\/j.biomaterials.2010.05.077","volume":"31","author":"C Rungsiyakull","year":"2010","unstructured":"Rungsiyakull C, Li Q, Sun G, Li W, Swain MV. Surface morphology optimization for osseointegration of coated implants. Biomaterials. 2010;31(27):7196\u2013204.","journal-title":"Biomaterials"},{"key":"6445_CR25","unstructured":"O\u2019Brien WJ. Dental materials and their selection. Quintessence Chicago; 2002."},{"issue":"1","key":"6445_CR26","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1186\/s12903-019-0838-x","volume":"19","author":"F Zarone","year":"2019","unstructured":"Zarone F, Di Mauro MI, Ausiello P, Ruggiero G, Sorrentino R. Current status on lithium disilicate and zirconia: a narrative review. BMC Oral Health. 2019;19(1):134.","journal-title":"BMC Oral Health"},{"key":"6445_CR27","doi-asserted-by":"crossref","unstructured":"Coldea A, Swain M, Thiel N. Mechanical properties of polymer-infiltrated-ceramic-network materials: official publication of the academy of dental materials. Dent Materials: Official Publication Acad Dent Mater. 2013;29.","DOI":"10.1016\/j.dental.2013.01.002"},{"issue":"1","key":"6445_CR28","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1186\/s12903-020-01202-7","volume":"20","author":"I Papathanasiou","year":"2020","unstructured":"Papathanasiou I, Kamposiora P, Papavasiliou G, Ferrari M. The use of PEEK in digital prosthodontics: A narrative review. BMC Oral Health. 2020;20(1):217.","journal-title":"BMC Oral Health"},{"issue":"5","key":"6445_CR29","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1016\/j.jmbbm.2008.11.007","volume":"2","author":"D Lin","year":"2009","unstructured":"Lin D, Li Q, Li W, Swain M. Dental implant induced bone remodeling and associated algorithms. J Mech Behav Biomed Mater. 2009;2(5):410\u201332.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"5","key":"6445_CR30","doi-asserted-by":"publisher","first-page":"772","DOI":"10.1177\/00220345760550051001","volume":"55","author":"AM Weinstein","year":"1976","unstructured":"Weinstein AM, Klawitter JJ, Anand SC, Schuessler R. Stress analysis of porous rooted dental implants. J Dent Res. 1976;55(5):772\u20137.","journal-title":"J Dent Res"},{"issue":"8","key":"6445_CR31","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1111\/jopr.13776","volume":"33","author":"P Poovarodom","year":"2024","unstructured":"Poovarodom P, Rungsiyakull C, Suriyawanakul J, Li Q, Sasaki K, Yoda N, Rungsiyakull P. Effect of customized abutment taper configuration on bone remodeling and peri-implant tissue around implant-supported single crown: A 3D nonlinear finite element study. J Prosthodont. 2024;33(8):815\u201323.","journal-title":"J Prosthodont"},{"issue":"3","key":"6445_CR32","doi-asserted-by":"publisher","first-page":"450","DOI":"10.2186\/jpr.JPR_D_22_00115","volume":"67","author":"T Graf","year":"2023","unstructured":"Graf T, Schweiger J, Stimmelmayr M, Erdelt K, Schubert O, G\u00fcth J-F. Influence of monolithic restorative materials on the implant-abutment interface of hybrid abutment crowns: an <\u2009i\u2009>\u2009in vitro\u2009investigation. J Prosthodontic Res. 2023;67(3):450\u20139.","journal-title":"J Prosthodontic Res"},{"issue":"4","key":"6445_CR33","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1038\/s41432-023-00935-y","volume":"24","author":"V Verma","year":"2023","unstructured":"Verma V, Hazari P, Verma P. Do implants made of polyetheretherketone and its composites have reduced stress shielding effects compared to other dental implant materials? A systematic review. Evid-Based Dent. 2023;24(4):193\u20134.","journal-title":"Evid-Based Dent"},{"key":"6445_CR34","doi-asserted-by":"publisher","first-page":"101136","DOI":"10.1016\/j.rechem.2023.101136","volume":"6","author":"N Hossain","year":"2023","unstructured":"Hossain N, Mobarak MH, Islam MA, Hossain A, Al Mahmud MZ, Rayhan MT, Chowdhury MA. Recent development of dental implant materials, synthesis process, and failure \u2013 A review. Results Chem. 2023;6:101136.","journal-title":"Results Chem"},{"issue":"6","key":"6445_CR35","doi-asserted-by":"publisher","first-page":"e852","DOI":"10.4317\/medoral.17243","volume":"16","author":"L Canullo","year":"2011","unstructured":"Canullo L, Pace F, Coelho P, Sciubba E, Vozza I. The influence of platform switching on the Biomechanical aspects of the implant-abutment system. A three dimensional finite element study. Med Oral Patol Oral Cir Bucal. 2011;16(6):e852\u20136.","journal-title":"Med Oral Patol Oral Cir Bucal"},{"issue":"21","key":"6445_CR36","doi-asserted-by":"publisher","first-page":"3831","DOI":"10.3390\/polym13213831","volume":"13","author":"PLB Sellan","year":"2021","unstructured":"Sellan PLB, Campaner LM, Tribst JPM, Dal Piva AMO, de Andrade GS, Borges ALS, et al. Functional or nonfunctional cusps preservation for molars restored with indirect composite or Glass-Ceramic onlays: 3D FEA study. Polymers. 2021;13(21):3831.","journal-title":"Polymers"},{"key":"6445_CR37","doi-asserted-by":"crossref","unstructured":"Misch CE, Goodacre CJ, Finley JM, Misch CM, Marinbach M, Dabrowsky T et al. Consensus conference panel report: crown-height space guidelines for implant dentistry-part 1. Implant Dent. 2005;14(4):312-8.","DOI":"10.1097\/01.id.0000188375.76066.23"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06445-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-06445-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06445-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,5]],"date-time":"2025-07-05T04:28:45Z","timestamp":1751689725000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-06445-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,5]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6445"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-06445-w","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,5]]},"assertion":[{"value":"9 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1106"}}