{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T14:46:30Z","timestamp":1791297990755,"version":"4.1.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T00:00:00Z","timestamp":1752192000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T00:00:00Z","timestamp":1752192000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["81970978"],"award-info":[{"award-number":["81970978"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"DOI":"10.1186\/s12903-025-06538-6","type":"journal-article","created":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T15:09:21Z","timestamp":1752246561000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Optimal sites for miniscrew insertion in anterior aesthetic region: a CBCT study for different vertical skeletal patterns"],"prefix":"10.1186","volume":"25","author":[{"given":"Xiaoyan","family":"Feng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luxi","family":"Weng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yiyang","family":"Shen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,11]]},"reference":[{"issue":"1","key":"6538_CR1","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.ajodo.2005.02.032","volume":"131","author":"S Kuroda","year":"2007","unstructured":"Kuroda S, Sugawara Y, Deguchi T, Kyung HM, Takano-Yamamoto T. Clinical use of Miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort. Am J Orthod Dentofac Orthop. 2007;131(1):9\u201315.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"12","key":"6538_CR2","doi-asserted-by":"publisher","first-page":"1351","DOI":"10.1111\/j.1600-0501.2009.01754.x","volume":"20","author":"M Schatzle","year":"2009","unstructured":"Schatzle M, Mannchen R, Zwahlen M, Lang NP. Survival and failure rates of orthodontic temporary anchorage devices: a systematic review. Clin Oral Implants Res. 2009;20(12):1351\u20139.","journal-title":"Clin Oral Implants Res"},{"issue":"3","key":"6538_CR3","doi-asserted-by":"publisher","first-page":"146","DOI":"10.4047\/jap.2012.4.3.146","volume":"4","author":"HJ Kim","year":"2012","unstructured":"Kim HJ, Yu SK, Lee MH, Lee HJ, Kim HJ, Chung CH. Cortical and cancellous bone thickness on the anterior region of alveolar bone in korean: a study of dentate human cadavers. J Adv Prosthodont. 2012;4(3):146\u201352.","journal-title":"J Adv Prosthodont"},{"issue":"8","key":"6538_CR4","doi-asserted-by":"publisher","first-page":"1073","DOI":"10.1016\/j.joen.2013.04.037","volume":"39","author":"G Lim","year":"2013","unstructured":"Lim G, Kim KD, Park W, Jung BY, Pang NS. Endodontic and surgical treatment of root damage caused by orthodontic Miniscrew placement. J Endod. 2013;39(8):1073\u20137.","journal-title":"J Endod"},{"issue":"6","key":"6538_CR5","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1007\/s00056-014-0235-7","volume":"75","author":"I Veli","year":"2014","unstructured":"Veli I, Uysal T, Baysal A, Karadede I. Buccal cortical bone thickness at Miniscrew placement sites in patients with different vertical skeletal patterns. J Orofac Orthop. 2014;75(6):417\u201329.","journal-title":"J Orofac Orthop"},{"issue":"4 Suppl","key":"6538_CR6","doi-asserted-by":"publisher","first-page":"e377","DOI":"10.1016\/j.ajodo.2009.10.039","volume":"139","author":"D Swasty","year":"2011","unstructured":"Swasty D, Lee J, Huang JC, Maki K, Gansky SA, Hatcher D, Miller AJ. Cross-sectional human mandibular morphology as assessed in vivo by cone-beam computed tomography in patients with different vertical facial dimensions. Am J Orthod Dentofac Orthop. 2011;139(4 Suppl):e377\u2013389.","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"6538_CR7","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1186\/1746-160X-9-13","volume":"9","author":"F Pan","year":"2013","unstructured":"Pan F, Kau CH, Zhou H, Souccar N. The anatomical evaluation of the dental arches using cone beam computed tomography\u2013an investigation of the availability of bone for placement of mini-screws. Head Face Med. 2013;9:13.","journal-title":"Head Face Med"},{"issue":"Suppl 1","key":"6538_CR8","first-page":"S99","volume":"12","author":"G Dharmadeep","year":"2020","unstructured":"Dharmadeep G, Naik MK, Reddy YM, Cheruluri S, Praveen Raj K, Reddy BR. Three-dimensional evaluation of interradicular areas and cortical bone thickness for orthodontic Miniscrew implant placement using Cone-beam computed tomography. J Pharm Bioallied Sci. 2020;12(Suppl 1):S99\u2013104.","journal-title":"J Pharm Bioallied Sci"},{"issue":"4","key":"6538_CR9","first-page":"ZC09","volume":"11","author":"SH Moslemzadeh","year":"2017","unstructured":"Moslemzadeh SH, Sohrabi A, Rafighi A, Kananizadeh Y, Nourizadeh A. Evaluation of interdental spaces of the mandibular posterior area for orthodontic Mini-Implants with Cone-Beam computed tomography. J Clin Diagn Res. 2017;11(4):ZC09\u201312.","journal-title":"J Clin Diagn Res"},{"issue":"5","key":"6538_CR10","doi-asserted-by":"publisher","first-page":"745","DOI":"10.2319\/011117-34.1","volume":"87","author":"R Nucera","year":"2017","unstructured":"Nucera R, Lo Giudice A, Bellocchio AM, Spinuzza P, Caprioglio A, Perillo L, Matarese G, Cordasco G. Bone and cortical bone thickness of mandibular buccal shelf for mini-screw insertion in adults. Angle Orthod. 2017;87(5):745\u201351.","journal-title":"Angle Orthod"},{"issue":"6","key":"6538_CR11","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1016\/j.ajodo.2011.05.020","volume":"140","author":"S Baumgaertel","year":"2011","unstructured":"Baumgaertel S. Cortical bone thickness and bone depth of the posterior palatal alveolar process for mini-implant insertion in adults. Am J Orthod Dentofac Orthop. 2011;140(6):806\u201311.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"2","key":"6538_CR12","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.ajodo.2007.08.031","volume":"136","author":"RC Santiago","year":"2009","unstructured":"Santiago RC, de Paula FO, Fraga MR, Picorelli Assis NM, Vitral RW. Correlation between Miniscrew stability and bone mineral density in orthodontic patients. Am J Orthod Dentofac Orthop. 2009;136(2):243\u201350.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"3","key":"6538_CR13","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1016\/j.ajodo.2023.02.013","volume":"164","author":"C Braga","year":"2023","unstructured":"Braga C, Pozzan L, Ciotola C, Viganoni C, Torelli L, Contardo L. Bone quality in relation to skeletal maturation in palatal miniscrews insertion sites. Am J Orthod Dentofac Orthop. 2023;164(3):406\u201315.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"1","key":"6538_CR14","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.ajodo.2006.01.044","volume":"133","author":"HS Park","year":"2008","unstructured":"Park HS, Lee YJ, Jeong SH, Kwon TG. Density of the alveolar and basal bones of the maxilla and the mandible. Am J Orthod Dentofac Orthop. 2008;133(1):30\u20137.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"8","key":"6538_CR15","doi-asserted-by":"publisher","first-page":"630","DOI":"10.5005\/jp-journals-10024-1733","volume":"16","author":"MM Al-Masri","year":"2015","unstructured":"Al-Masri MM, Ajaj MA, Hajeer MY, Al-Eed MS. Evaluation of bone thickness and density in the lower incisors\u2019 region in adults with different types of skeletal malocclusion using Cone-beam computed tomography. J Contemp Dent Pract. 2015;16(8):630\u20137.","journal-title":"J Contemp Dent Pract"},{"issue":"5","key":"6538_CR16","doi-asserted-by":"publisher","first-page":"939","DOI":"10.2319\/121009-709.1","volume":"80","author":"MM Fayed","year":"2010","unstructured":"Fayed MM, Pazera P, Katsaros C. Optimal sites for orthodontic mini-implant placement assessed by cone beam computed tomography. Angle Orthod. 2010;80(5):939\u201351.","journal-title":"Angle Orthod"},{"issue":"1","key":"6538_CR17","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1111\/clr.12315","volume":"26","author":"A Parsa","year":"2015","unstructured":"Parsa A, Ibrahim N, Hassan B, van der Stelt P, Wismeijer D. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT. Clin Oral Implants Res. 2015;26(1):e1\u20137.","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"6538_CR18","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.oooo.2013.04.013","volume":"116","author":"R Molteni","year":"2013","unstructured":"Molteni R. Prospects and challenges of rendering tissue density in Hounsfield units for cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;116(1):105\u201319.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"issue":"3","key":"6538_CR19","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1016\/j.oooo.2021.06.013","volume":"133","author":"D Holzinger","year":"2022","unstructured":"Holzinger D, Carvalho PHA, Dos Santos JC, Wagner F, Gabrielli MAC, Gabrielli MFR, Filho VAP. Bone formation after surgically assisted rapid maxillary expansion: comparison of 2 distraction osteogenesis protocols. Oral Surg Oral Med Oral Pathol Oral Radiol. 2022;133(3):271\u20136.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"issue":"1","key":"6538_CR20","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1186\/s40510-018-0225-1","volume":"19","author":"H Mohammed","year":"2018","unstructured":"Mohammed H, Wafaie K, Rizk MZ, Almuzian M, Sosly R, Bearn DR. Role of anatomical sites and correlated risk factors on the survival of orthodontic Miniscrew implants: a systematic review and meta-analysis. Prog Orthod. 2018;19(1):36.","journal-title":"Prog Orthod"},{"issue":"4","key":"6538_CR21","doi-asserted-by":"publisher","first-page":"3523","DOI":"10.1007\/s00784-021-04321-9","volume":"26","author":"M Palone","year":"2022","unstructured":"Palone M, Darsie A, Maino GB, Siciliani G, Spedicato GA, Lombardo L. Analysis of biological and structural factors implicated in the clinical success of orthodontic miniscrews at posterior maxillary interradicular sites. Clin Oral Investig. 2022;26(4):3523\u201332.","journal-title":"Clin Oral Investig"},{"issue":"1","key":"6538_CR22","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1034\/j.1600-0544.2000.030105.x","volume":"3","author":"B Melsen","year":"2000","unstructured":"Melsen B, Costa A. Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res. 2000;3(1):23\u20138.","journal-title":"Clin Orthod Res"},{"issue":"4","key":"6538_CR23","doi-asserted-by":"publisher","first-page":"509","DOI":"10.2319\/083020-756.1","volume":"91","author":"Y Lee","year":"2021","unstructured":"Lee Y, Choi SH, Yu HS, Erenebat T, Liu J, Cha JY. Stability and success rate of dual-thread miniscrews. Angle Orthod. 2021;91(4):509\u201314.","journal-title":"Angle Orthod"},{"issue":"3","key":"6538_CR24","doi-asserted-by":"publisher","first-page":"232","DOI":"10.2334\/josnusd.21-0536","volume":"64","author":"R Ikenaka","year":"2022","unstructured":"Ikenaka R, Koizumi S, Otsuka T, Yamaguchi T. Effects of root contact length on the failure rate of anchor screw. J Oral Sci. 2022;64(3):232\u20135.","journal-title":"J Oral Sci"},{"issue":"1","key":"6538_CR25","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1186\/s12903-021-01891-8","volume":"21","author":"A Golshah","year":"2021","unstructured":"Golshah A, Salahshour M, Nikkerdar N. Interradicular distance and alveolar bone thickness for Miniscrew insertion: a CBCT study of Persian adults with different sagittal skeletal patterns. BMC Oral Health. 2021;21(1):534.","journal-title":"BMC Oral Health"},{"key":"6538_CR26","doi-asserted-by":"crossref","unstructured":"Poggio PM, Incorvati C, Velo S, Carano A, Truong VM, Kim S, Kim J, Lee JW, Park YS. Safe zones: a guide for miniscrew positioning in the maxillary and mandibular arch. Angle Orthod: Revisiting the Complications of Orthodontic Miniscrew. Biomed Res Int 2022;2022:8720412.","DOI":"10.1155\/2022\/8720412"},{"issue":"4","key":"6538_CR27","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1111\/j.1601-6343.2009.01465.x","volume":"12","author":"JE Lim","year":"2009","unstructured":"Lim JE, Lee SJ, Kim YJ, Lim WH, Chun YS. Comparison of cortical bone thickness and root proximity at maxillary and mandibular interradicular sites for orthodontic mini-implant placement. Orthod Craniofac Res. 2009;12(4):299\u2013304.","journal-title":"Orthod Craniofac Res"},{"issue":"5","key":"6538_CR28","first-page":"779","volume":"22","author":"M Motoyoshi","year":"2007","unstructured":"Motoyoshi M, Yoshida T, Ono A, Shimizu N. Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. Int J Oral Maxillofac Implants. 2007;22(5):779\u201384.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"2","key":"6538_CR29","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1016\/j.ajodo.2012.09.013","volume":"143","author":"F Ozdemir","year":"2013","unstructured":"Ozdemir F, Tozlu M, Germec-Cakan D. Cortical bone thickness of the alveolar process measured with cone-beam computed tomography in patients with different facial types. Am J Orthod Dentofac Orthop. 2013;143(2):190\u20136.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"3","key":"6538_CR30","doi-asserted-by":"publisher","first-page":"500","DOI":"10.2319\/052513-39.1","volume":"84","author":"M Marquezan","year":"2014","unstructured":"Marquezan M, Lima I, Lopes RT, Sant\u2019Anna EF, de Souza MM. Is trabecular bone related to primary stability of miniscrews? Angle Orthod. 2014;84(3):500\u20137.","journal-title":"Angle Orthod"},{"issue":"Suppl 1","key":"6538_CR31","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1111\/ocr.12453","volume":"24","author":"DW Lee","year":"2021","unstructured":"Lee DW, Park JH, Bay RC, Choi SK, Chae JM. Cortical bone thickness and bone density effects on Miniscrew success rates: A systematic review and meta-analysis. Orthod Craniofac Res. 2021;24(Suppl 1):92\u2013102.","journal-title":"Orthod Craniofac Res"},{"issue":"1","key":"6538_CR32","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.ajodo.2016.05.015","volume":"151","author":"H Ohiomoba","year":"2017","unstructured":"Ohiomoba H, Sonis A, Yansane A, Friedland B. Quantitative evaluation of maxillary alveolar cortical bone thickness and density using computed tomography imaging. Am J Orthod Dentofac Orthop. 2017;151(1):82\u201391.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"2","key":"6538_CR33","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1016\/j.jobcr.2013.01.001","volume":"3","author":"T Chugh","year":"2013","unstructured":"Chugh T, Jain AK, Jaiswal RK, Mehrotra P, Mehrotra R. Bone density and its importance in orthodontics. J Oral Biol Craniofac Res. 2013;3(2):92\u20137.","journal-title":"J Oral Biol Craniofac Res"},{"issue":"6","key":"6538_CR34","doi-asserted-by":"publisher","first-page":"905","DOI":"10.2319\/092714.695.1","volume":"85","author":"C Chang","year":"2015","unstructured":"Chang C, Liu SS, Roberts WE. Primary failure rate for 1680 extra-alveolar mandibular buccal shelf mini-screws placed in movable mucosa or attached gingiva. Angle Orthod. 2015;85(6):905\u201310.","journal-title":"Angle Orthod"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06538-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-06538-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06538-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,7]],"date-time":"2025-09-07T05:49:54Z","timestamp":1757224194000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-06538-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,11]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6538"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-06538-6","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,11]]},"assertion":[{"value":"22 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Clinical Research Ethics Committee of the First Afliated Hospital, College of Medicine, Zhejiang University (protocol code: (2022) IIT (819) and date of approval: 1 Sep 2022) and was conducted in accordance with the Declaration of Helsinki for research involving human subjects. The study was explained, and informed consent was obtained from the patients.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1148"}}