{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T09:09:35Z","timestamp":1793956175654,"version":"4.8.0"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T00:00:00Z","timestamp":1753315200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T00:00:00Z","timestamp":1753315200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009827","name":"Alexandria University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100009827","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The primary method for fabrication of zirconia restorations is subtractive manufacturing technology. This process mills restorations from large blocks using various cutting tools resulting in large amounts of waste material. 3D printing has emerged as an alternative tool for additive manufacturing of zirconia with less waste and high efficiency.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      A total of 24 monolithic zirconia crowns were divided into: Group I (milled zirconia crowns) and Group II (3D printed zirconia crowns) (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200912). The crowns were then polished and glazed then subjected to 5000 thermocycles. Fracture resistance for the crowns was measured using universal testing machine followed by estimation of Weibull modulus and characteristic strength. Fractographic analysis was done using scanning electron microscope (SEM). 72 discs (10\u00a0mm\u2009\u00d7\u20092\u00a0mm) were fabricated by milling and printing (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200936) then subjected to 5000 thermocycles. The discs were used for surface roughness assessment both before (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200912) and after (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200912) glazing using contact profilometer and unglazed discs (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200912) were used for microhardness which was measured by Vickers microhardness tester. Comparisons between study groups were performed using independent samples t-test. Two-way ANOVA was performed to assess the association between material (milled or printed) and glazing (glazed or unglazed) with surface roughness. Significance level was set at\n                      <jats:italic>P<\/jats:italic>\n                      -value\u2009&lt;\u20090.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      In comparison to 3D printed zirconia, the milled version exhibited comparable fracture resistance, reduced surface roughness, and increased microhardness. While both groups showed comparable fracture resistance with no significant difference (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.26), the milled zirconia demonstrated significantly better surface finish (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.001) and microhardness (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.001). However, glazing lowered the surface roughness significantly for both milled (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.001) and printed (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.001) zirconia, bridging the gap in surface quality between the two fabrication techniques.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The enhanced fracture resistance and Weibull modulus of 3D printed zirconia indicate increased reliability and consistency in its mechanical properties. However, limitations of its surface properties highlight the need for further optimization before full clinical adoption.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-025-06570-6","type":"journal-article","created":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T14:24:10Z","timestamp":1753367050000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Evaluation of fracture resistance and surface characteristics in monolithic zirconia: a comparative analysis of 3D printing and milling techniques"],"prefix":"10.1186","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-3367-8443","authenticated-orcid":false,"given":"Rogina M.","family":"Hassan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yomna","family":"Ibrahim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rewaa G.","family":"AboELHassan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir Shoukry","family":"Azer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,24]]},"reference":[{"issue":"9","key":"6570_CR1","doi-asserted-by":"publisher","first-page":"2122","DOI":"10.3390\/ma17092122","volume":"17","author":"A Zenth\u00f6fer","year":"2024","unstructured":"Zenth\u00f6fer A, Fien D, Rossipal J, Ilani A, Schmitt C, Hetzler S, Rammelsberg P, Rues S. Fracture resistance of 3D-printed occlusal veneers made from 3Y-TZP zirconia. Materials. 2024;17(9):2122.","journal-title":"Materials"},{"issue":"9","key":"6570_CR2","doi-asserted-by":"publisher","first-page":"1459","DOI":"10.1016\/j.dental.2022.06.026","volume":"38","author":"J L\u00fcchtenborg","year":"2022","unstructured":"L\u00fcchtenborg J, Willems E, Zhang F, Wesemann C, Weiss F, Nold J, Sun J, Sandra F, Bai J, Reveron H. Accuracy of additively manufactured zirconia four-unit fixed dental prostheses fabricated by stereolithography, digital light processing and material jetting compared with subtractive manufacturing. Dent Mater. 2022;38(9):1459\u201369.","journal-title":"Dent Mater"},{"issue":"2","key":"6570_CR3","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1177\/0022034517737483","volume":"97","author":"Y Zhang","year":"2018","unstructured":"Zhang Y, Lawn BR. Novel zirconia materials in dentistry. J Dent Res. 2018;97(2):140\u20137.","journal-title":"J Dent Res"},{"issue":"1","key":"6570_CR4","first-page":"36","volume":"119","author":"R Shahmiri","year":"2018","unstructured":"Shahmiri R, Standard OC, Hart JN, Sorrell CC. Optical properties of zirconia ceramics for esthetic dental restorations: a systematic review. J Prosthodont. 2018;119(1):36\u201346.","journal-title":"J Prosthodont"},{"issue":"9","key":"6570_CR5","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1111\/jopr.13487","volume":"31","author":"K Bataineh","year":"2022","unstructured":"Bataineh K, Al Janaideh M, Abu-Naba\u2019a LA. Fatigue resistance of 3-unit CAD-CAM ceramic fixed partial dentures: an FEA study. J Prosthodont. 2022;31(9):806\u201314.","journal-title":"J Prosthodont"},{"issue":"9","key":"6570_CR6","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.14219\/jada.archive.2006.0389","volume":"137","author":"JR Strub","year":"2006","unstructured":"Strub JR, Rekow ED, Witkowski S. Computer-aided design and fabrication of dental restorations: current systems and future possibilities. J Am Dent Assoc. 2006;137(9):1289\u201396.","journal-title":"J Am Dent Assoc"},{"key":"6570_CR7","first-page":"101","volume":"57","author":"E Tzanakakis","year":"2013","unstructured":"Tzanakakis E, Tzoutzas I, Kontonasaki E. Zirconia: contemporary views of a much talked material: structure, applications and clinical considerations. Hellenic Stomatolog Rev. 2013;57:101\u201337.","journal-title":"Hellenic Stomatolog Rev"},{"issue":"1","key":"6570_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/dj12010001","volume":"12","author":"M Jeong","year":"2023","unstructured":"Jeong M, Radomski K, Lopez D, Liu JT, Lee JD, Lee SJ. Materials and applications of 3D printing technology in dentistry: an overview. Dent J. 2023;12(1):1.","journal-title":"Dent J"},{"issue":"12","key":"6570_CR9","doi-asserted-by":"publisher","first-page":"2350","DOI":"10.3390\/ma11122350","volume":"11","author":"DA Komissarenko","year":"2018","unstructured":"Komissarenko DA, Sokolov PS, Evstigneeva AD, Shmeleva IA, Dosovitsky AE. Rheological and curing behavior of acrylate-based suspensions for the DLP 3D printing of complex zirconia parts. Materials. 2018;11(12):2350.","journal-title":"Materials"},{"issue":"18","key":"6570_CR10","doi-asserted-by":"publisher","first-page":"9088","DOI":"10.3390\/app12189088","volume":"12","author":"MS Kim","year":"2022","unstructured":"Kim MS, Hong MH, Min BK, Kim YK, Shin HJ, Kwon TY. Microstructure, flexural strength, and fracture toughness comparison between CAD\/CAM milled and 3D-printed zirconia ceramics. Appl Sci. 2022;12(18):9088.","journal-title":"Appl Sci"},{"key":"6570_CR11","doi-asserted-by":"publisher","first-page":"106601","DOI":"10.1016\/j.jmbbm.2024.106601","volume":"156","author":"MA Alghauli","year":"2024","unstructured":"Alghauli MA, Alqutaibi AY, Wille S, Kern M. The physical-mechanical properties of 3D-printed versus conventional milled zirconia for dental clinical applications: a systematic review with meta-analysis. J Mech Behav Biomed Mater. 2024;156:106601.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"8","key":"6570_CR12","doi-asserted-by":"publisher","first-page":"602","DOI":"10.3109\/00016357.2015.1007479","volume":"73","author":"K Nakamura","year":"2015","unstructured":"Nakamura K, Harada A, Inagaki R, Kanno T, Niwano Y, Milleding P, \u00d6rtengren U. Fracture resistance of monolithic zirconia molar crowns with reduced thickness. Acta Odontol Scand. 2015;73(8):602\u20138.","journal-title":"Acta Odontol Scand"},{"issue":"1","key":"6570_CR13","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1186\/s12903-022-02431-8","volume":"22","author":"A Elraggal","year":"2022","unstructured":"Elraggal A, Aboushelib M, Abdel Raheem IM, Afifi RR. Effect of surface treatments on biaxial flexural strength, fatigue resistance, and fracture toughness of high versus low translucency zirconia. BMC Oral Health. 2022;22(1):412.","journal-title":"BMC Oral Health"},{"issue":"10","key":"6570_CR14","doi-asserted-by":"publisher","first-page":"6125","DOI":"10.1007\/s00784-023-05229-2","volume":"27","author":"A Refaie","year":"2023","unstructured":"Refaie A, Bourauel C, Fouda AM, Keilig L, Singer L. The effect of cyclic loading on the fracture resistance of 3D-printed and CAD\/CAM milled zirconia crowns\u2014an in vitro study. Clin Oral Investig. 2023;27(10):6125\u201333.","journal-title":"Clin Oral Investig"},{"issue":"8","key":"6570_CR15","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1016\/j.dental.2010.04.006","volume":"26","author":"V Lughi","year":"2010","unstructured":"Lughi V, Sergo V. Low temperature degradation-aging-of zirconia: a critical review of the relevant aspects in dentistry. Dent Mater. 2010;26(8):807\u201320.","journal-title":"Dent Mater"},{"issue":"14","key":"6570_CR16","doi-asserted-by":"publisher","first-page":"4861","DOI":"10.3390\/ma15144861","volume":"15","author":"SH Kim","year":"2022","unstructured":"Kim SH, Yeo MY, Choi SY, Park EJ. Fracture resistance of monolithic zirconia crowns depending on different marginal thicknesses. Materials. 2022;15(14):4861.","journal-title":"Materials"},{"issue":"4","key":"6570_CR17","first-page":"363","volume":"85","author":"CJ Goodacre","year":"2001","unstructured":"Goodacre CJ, Campagni WV, Aquilino SA. Tooth preparations for complete crowns: an art form based on scientific principles. J Prosthodont. 2001;85(4):363\u201376.","journal-title":"J Prosthodont"},{"issue":"1","key":"6570_CR18","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1186\/s12903-023-03184-8","volume":"23","author":"A Refaie","year":"2023","unstructured":"Refaie A, Fouda A, Bourauel C, Singer L. Marginal gap and internal fit of 3D printed versus milled monolithic zirconia crowns. BMC Oral Health. 2023;23(1):448.","journal-title":"BMC Oral Health"},{"issue":"1","key":"6570_CR19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12903-025-05542-0","volume":"25","author":"MS Elsayed","year":"2025","unstructured":"Elsayed MS, El-Kouedi AY, Shokry TE. Effect of aging on the marginal fit of milled and printed zirconia crowns: an in-vitro study. BMC Oral Health. 2025;25(1):1\u20139.","journal-title":"BMC Oral Health"},{"key":"6570_CR20","first-page":"b4145161","volume":"25","author":"KY Yim","year":"2023","unstructured":"Yim KY, Beh YH, Goo CL. Effects of surface treatment and thermocycling on the shear bond strength of zirconia-reinforced lithium silicate ceramic. J Adhes Dent. 2023;25:b4145161.","journal-title":"J Adhes Dent"},{"issue":"1","key":"6570_CR21","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1186\/s12903-024-05325-z","volume":"25","author":"AK Fayed","year":"2025","unstructured":"Fayed AK, Azer AS, AboElhassan RG. Fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in-vitro study). BMC Oral Health. 2025;25(1):58.","journal-title":"BMC Oral Health"},{"issue":"1","key":"6570_CR22","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1186\/s12903-023-03829-8","volume":"24","author":"MS Hajjaj","year":"2024","unstructured":"Hajjaj MS, Alamoudi RA, Babeer WA, Rizg WY, Basalah AA, Alzahrani SJ, Yeslam HE. Flexural strength, flexural modulus and microhardness of milled vs fused deposition modeling printed zirconia; effect of conventional vs speed sintering. BMC Oral Health. 2024;24(1):38.","journal-title":"BMC Oral Health"},{"issue":"1","key":"6570_CR23","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1186\/s12903-022-02628-x","volume":"22","author":"OI El Shahawy","year":"2022","unstructured":"El Shahawy OI, Azab MM. Fracture resistance of prefabricated versus custom-made zirconia crowns after thermo-mechanical aging: an in-vitro study. BMC Oral Health. 2022;22(1):587.","journal-title":"BMC Oral Health"},{"issue":"1","key":"6570_CR24","doi-asserted-by":"publisher","first-page":"36","DOI":"10.3390\/jfb16010036","volume":"16","author":"S Hetzler","year":"2025","unstructured":"Hetzler S, Hinzen C, Rues S, Schmitt C, Rammelsberg P, Zenth\u00f6fer A. Biaxial flexural strength and vickers hardness of 3D-printed and milled 5Y partially stabilized zirconia. J Funct Biomater. 2025;16(1):36.","journal-title":"J Funct Biomater"},{"issue":"1","key":"6570_CR25","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1186\/s12903-022-02389-7","volume":"22","author":"S Dikicier","year":"2022","unstructured":"Dikicier S, Korkmaz C, Atay A. Surface roughness and characteristics of CAD\/CAM zirconia and glass ceramics after combined treatment procedures. BMC Oral Health. 2022;22(1):524.","journal-title":"BMC Oral Health"},{"issue":"6","key":"6570_CR26","doi-asserted-by":"publisher","first-page":"777","DOI":"10.11607\/ijp.6749","volume":"35","author":"M Bergler","year":"2022","unstructured":"Bergler M, Korostoff J, Torrecillas-Martinez L, Mante FK. Ceramic printing-comparative study of the flexural strength of 3D-printed and milled zirconia. Int J Prosthodont. 2022;35(6):777.","journal-title":"Int J Prosthodont"},{"issue":"2","key":"6570_CR27","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.jpor.2016.01.003","volume":"60","author":"TF Alghazzawi","year":"2016","unstructured":"Alghazzawi TF. Advancements in CAD\/CAM technology: options for practical implementation. J Prosthodont Res. 2016;60(2):72\u201384.","journal-title":"J Prosthodont Res"},{"issue":"4","key":"6570_CR28","doi-asserted-by":"publisher","first-page":"1602","DOI":"10.3390\/ma15041602","volume":"15","author":"B Wang","year":"2022","unstructured":"Wang B, Arab A, Xie J, Chen P. The influence of microstructure on the flexural properties of 3D printed zirconia part via digital light processing technology. Materials. 2022;15(4):1602.","journal-title":"Materials"},{"key":"6570_CR29","first-page":"101450","volume":"36","author":"C Marsico","year":"2020","unstructured":"Marsico C, \u00d8ilo M, Kutsch J, Kauf M, Arola D. Vat polymerization-printed partially stabilized zirconia: mechanical properties, reliability and structural defects. Addit Manuf. 2020;36:101450.","journal-title":"Addit Manuf"},{"key":"6570_CR30","doi-asserted-by":"publisher","first-page":"105944","DOI":"10.1016\/j.jmbbm.2023.105944","volume":"143","author":"Y Lu","year":"2023","unstructured":"Lu Y, Wang L. Dal Piva AMdO, Tribst JPM, Nedeljkovic I, Kleverlaan CJ, Feilzer AJ: Influence of surface finishing and printing layer orientation on surface roughness and flexural strength of stereolithography-manufactured dental zirconia. J Mech Behav Biomed Mater. 2023;143: 105944.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"1","key":"6570_CR31","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1186\/s13036-023-00396-y","volume":"17","author":"G Su","year":"2023","unstructured":"Su G, Zhang Y, Jin C, Zhang Q, Lu J, Liu Z, Wang Q, Zhang X, Ma J. 3D printed zirconia used as dental materials: a critical review. J Biol Eng. 2023;17(1):78.","journal-title":"J Biol Eng"},{"issue":"1","key":"6570_CR32","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.jpor.2018.02.002","volume":"63","author":"JY Sim","year":"2019","unstructured":"Sim JY, Jang Y, Kim WC, Kim HY, Lee DH, Kim JH. Comparing the accuracy (trueness and precision) of models of fixed dental prostheses fabricated by digital and conventional workflows. J Prosthodont Res. 2019;63(1):25\u201330.","journal-title":"J Prosthodont Res"},{"issue":"1","key":"6570_CR33","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1186\/s12903-023-02974-4","volume":"23","author":"A Patil","year":"2023","unstructured":"Patil A, Bomze D, Gopal V. Wear behaviour of lithography ceramic manufactured dental zirconia. BMC Oral Health. 2023;23(1):276.","journal-title":"BMC Oral Health"},{"issue":"20","key":"6570_CR34","doi-asserted-by":"publisher","first-page":"28837","DOI":"10.1016\/j.ceramint.2021.07.044","volume":"47","author":"D Xiang","year":"2021","unstructured":"Xiang D, Xu Y, Bai W, Lin H. Dental zirconia fabricated by stereolithography: accuracy, translucency and mechanical properties in different build orientations. Ceram Int. 2021;47(20):28837\u201347.","journal-title":"Ceram Int"},{"issue":"4","key":"6570_CR35","doi-asserted-by":"publisher","first-page":"439","DOI":"10.21608\/ajdsm.2023.225810.1443","volume":"26","author":"SO Nabih","year":"2023","unstructured":"Nabih SO, Ahmed FAM. Surface roughness and hardness of translucent zirconia with different post-sintering interventions. Al-Azhar J Dent Sci. 2023;26(4):439\u201347.","journal-title":"Al-Azhar J Dent Sci"},{"key":"6570_CR36","doi-asserted-by":"publisher","first-page":"1512887","DOI":"10.3389\/fdmed.2025.1512887","volume":"6","author":"Y Lu","year":"2025","unstructured":"Lu Y, van Steenoven A, Dal Piva AMDO, Tribst JPM, Wang L, Kleverlaan CJ, Feilzer AJ. Additive-manufactured ceramics for dental restorations: a systematic review on mechanical perspective. Front Dent Med. 2025;6:1512887.","journal-title":"Front Dent Med"},{"issue":"1","key":"6570_CR37","doi-asserted-by":"publisher","first-page":"6612840","DOI":"10.1155\/2021\/6612840","volume":"2021","author":"Z Mei","year":"2021","unstructured":"Mei Z, Lu Y, Lou Y, Yu P, Sun M, Tan X, Zhang J, Yue L, Yu H. Determination of hardness and fracture toughness of Y-TZP manufactured by digital light processing through the indentation technique. Biomed Res Int. 2021;2021(1):6612840.","journal-title":"Biomed Res Int"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06570-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-06570-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06570-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,7]],"date-time":"2025-09-07T21:58:08Z","timestamp":1757282288000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-06570-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,24]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6570"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-06570-6","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,24]]},"assertion":[{"value":"30 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1236"}}