{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T21:11:58Z","timestamp":1791839518970,"version":"4.3.4"},"reference-count":48,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,29]],"date-time":"2025-07-29T00:00:00Z","timestamp":1753747200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,7,29]],"date-time":"2025-07-29T00:00:00Z","timestamp":1753747200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Kirikkale University Scientific Research Projects Coordination Unit","award":["Project No: 2022\/068"],"award-info":[{"award-number":["Project No: 2022\/068"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"DOI":"10.1186\/s12903-025-06593-z","type":"journal-article","created":{"date-parts":[[2025,7,29]],"date-time":"2025-07-29T02:46:01Z","timestamp":1753757161000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Thermal analysis of a dry cooling method in a dental implant drilling procedure: an in vitro randomized study"],"prefix":"10.1186","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3927-3861","authenticated-orcid":false,"given":"Kubilay","family":"Baris","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1518-4159","authenticated-orcid":false,"given":"Meltem","family":"Hendek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7298-8589","authenticated-orcid":false,"given":"Hatice Ebru","family":"Olgun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,29]]},"reference":[{"key":"6593_CR1","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-024-05958-y","volume":"28","author":"MAL Shayeb","year":"2024","unstructured":"Shayeb MAL, Elfadil S, Abutayyem H, Shqaidef A, Marrapodi MM, Cicci\u00f9 M, et al. Bioactive surface modifications on dental implants: a systematic review and meta-analysis of osseointegration and longevity. Clin Oral Investig. 2024;28: 592.","journal-title":"Clin Oral Investig"},{"key":"6593_CR2","doi-asserted-by":"publisher","first-page":"1361","DOI":"10.1111\/j.1600-0501.2010.02126.x","volume":"22","author":"A Rashad","year":"2011","unstructured":"Rashad A, Kaiser A, Prochnow N, Schmitz I, Hoffmann E, Maurer P. Heat production during different ultrasonic and conventional osteotomy preparations for dental implants. Clin Oral Implants Res. 2011;22:1361\u20135.","journal-title":"Clin Oral Implants Res"},{"key":"6593_CR3","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1111\/j.1600-0501.2011.02248.x","volume":"23","author":"N Oliveira","year":"2012","unstructured":"Oliveira N, Alaejos-Algarra F, Mareque-Bueno J, Ferr\u00e9s-Padr\u00f3 E, Hern\u00e1ndez-Alfaro F. Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: twisted stainless steel and ceramic drills. Clin Oral Implants Res. 2012;23:963\u20139.","journal-title":"Clin Oral Implants Res"},{"key":"6593_CR4","doi-asserted-by":"publisher","first-page":"622","DOI":"10.1111\/clr.12090","volume":"25","author":"GD Strbac","year":"2014","unstructured":"Strbac GD, Giannis K, Unger E, Mittlb\u00f6ck M, Watzek G, Zechner W. A novel standardized bone model for thermal evaluation of bone osteotomies with various irrigation methods. Clin Oral Implants Res. 2014;25:622\u201331.","journal-title":"Clin Oral Implants Res"},{"key":"6593_CR5","doi-asserted-by":"publisher","first-page":"e517","DOI":"10.4317\/medoral.26495","volume":"29","author":"F Camacho-Alonso","year":"2024","unstructured":"Camacho-Alonso F, P\u00e9rez-Say\u00e1ns M, Pato-Mourelo J, Mart\u00ednez-Mart\u00ednez JE. Accuracy in osteotomy drilling using a new universal and disposable drill-stop device for dental implant drills: an in vitro study using a bovine rib model. Med Oral Patol Oral Cir Bucal. 2024;29:e517\u201326.","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"6593_CR6","first-page":"e730","volume":"22","author":"H Pellicer-Chover","year":"2017","unstructured":"Pellicer-Chover H, Pe\u00f1arrocha-Oltra D, Aloy-Prosper A, Sanchis-Gonzalez J-C, Pe\u00f1arrocha-Diago M, Pe\u00f1arrocha-Diago M. Comparison of peri-implant bone loss between conventional drilling with irrigation versus low-speed drilling without irrigation. Med Oral Patol Oral Cir Bucal. 2017;22:e730\u20136.","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"6593_CR7","doi-asserted-by":"publisher","first-page":"101010","DOI":"10.1115\/1.4040312","volume":"140","author":"M Aghvami","year":"2018","unstructured":"Aghvami M, Brunski JB, Serdar Tulu U, Chen C-H, Helms JA. A thermal and biological analysis of bone drilling. J Biomech Eng. 2018;140:101010\u20138.","journal-title":"J Biomech Eng"},{"key":"6593_CR8","first-page":"e5226","volume":"11","author":"C Timon","year":"2019","unstructured":"Timon C, Keady C. Thermal osteonecrosis caused by bone drilling in orthopedic surgery: a literature review. Cureus. 2019;11:e5226.","journal-title":"Cureus"},{"key":"6593_CR9","doi-asserted-by":"publisher","first-page":"1047","DOI":"10.1007\/s00784-020-03398-y","volume":"25","author":"O Salom\u00f3-Coll","year":"2021","unstructured":"Salom\u00f3-Coll O, Auriol-Muerza B, Lozano-Carrascal N, Hern\u00e1ndez-Alfaro F, Wang H-L, Gargallo-Albiol J. Influence of bone density, drill diameter, drilling speed, and irrigation on temperature changes during implant osteotomies: an in vitro study. Clin Oral Investig. 2021;25:1047\u201353.","journal-title":"Clin Oral Investig"},{"key":"6593_CR10","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1002\/jbm.b.34975","volume":"110","author":"RP Singh","year":"2022","unstructured":"Singh RP, Pandey PM, Mir MA, Mridha AR. Thermal changes during drilling in human femur by rotary ultrasonic bone drilling machine: a histologic and ultrastructural study. J Biomed Mater Res B Appl Biomater. 2022;110:1023\u201333.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"6593_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.11607\/jomi.11066","volume":"31","author":"A Brizuela-Velasco","year":"2025","unstructured":"Brizuela-Velasco A, Robles D, Fern\u00e1ndez-Hern\u00e1ndez S, Mendes JM, Sanz I, Gil J. Thermal changes during digital guided implant surgery using the conventional and single drill protocols. Int J Oral Maxillofac Implants. 2025;31:1\u201322.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"6593_CR12","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/0278-2391(86)90006-6","volume":"44","author":"RA Eriksson","year":"1986","unstructured":"Eriksson RA, Adell R. Temperatures during drilling for the placement of implants using the osseointegration technique. J Oral Maxillofac Surg. 1986;44:4\u20137.","journal-title":"J Oral Maxillofac Surg"},{"key":"6593_CR13","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/0022-3913(83)90174-9","volume":"50","author":"AR Eriksson","year":"1983","unstructured":"Eriksson AR, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent. 1983;50:101\u20137.","journal-title":"J Prosthet Dent"},{"key":"6593_CR14","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1302\/0301-620X.78B4.0780584","volume":"78","author":"M Leunig","year":"1996","unstructured":"Leunig M, Hertel R. Thermal necrosis after tibial reaming for intramedullary nail fixation: a report of three cases. J Bone Joint Surg Br. 1996;78:584\u20137.","journal-title":"J Bone Joint Surg Br"},{"key":"6593_CR15","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1111\/cid.12172","volume":"17","author":"SA Gehrke","year":"2015","unstructured":"Gehrke SA, Bettach R, Taschieri S, Boukhris G, Corbella S, Del Fabbro M. Temperature changes in cortical bone after implant site preparation using a single bur versus multiple drilling steps: an in vitro investigation. Clin Implant Dent Relat Res. 2015;17:700\u20137.","journal-title":"Clin Implant Dent Relat Res"},{"key":"6593_CR16","first-page":"29","volume":"15","author":"J Lindstr\u00f6m","year":"1981","unstructured":"Lindstr\u00f6m J, Br\u00e5nemark P-I, Albrektsson T. Mandibular reconstruction using the preformed autologous bone graft. Scand J Plast Reconstr Surg. 1981;15:29\u201338.","journal-title":"Scand J Plast Reconstr Surg"},{"key":"6593_CR17","doi-asserted-by":"publisher","first-page":"e19","DOI":"10.1563\/AAID-JOI-D-13-00151","volume":"41","author":"K-T Koo","year":"2015","unstructured":"Koo K-T, Kim M-H, Kim H-Y, Wikesj\u00f6 UME, Yang J-H, Yeo I-S. Effects of implant drill wear, irrigation, and drill materials on heat generation in osteotomy sites. J Oral Implantol. 2015;41:e19-23.","journal-title":"J Oral Implantol"},{"key":"6593_CR18","first-page":"212","volume":"7","author":"F Watanabe","year":"1992","unstructured":"Watanabe F, Tawada Y, Komatsu S, Hata Y. Heat distribution in bone during preparation of implant sites: heat analysis by real-time thermography. Int J Oral Maxillofac Implants. 1992;7:212\u20139.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"6593_CR19","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1111\/j.1600-0501.2008.01643.x","volume":"20","author":"BC Sener","year":"2009","unstructured":"Sener BC, Dergin G, Gursoy B, Kelesoglu E, Slih I. Effects of irrigation temperature on heat control in vitro at different drilling depths. Clin Oral Implants Res. 2009;20:294\u20138.","journal-title":"Clin Oral Implants Res"},{"key":"6593_CR20","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1034\/j.1600-0501.2002.130309.x","volume":"13","author":"IC Benington","year":"2002","unstructured":"Benington IC, Biagioni PA, Briggs J, Sheridan S, Lamey P. Thermal changes observed at implant sites during internal and external irrigation. Clin Oral Implants Res. 2002;13:293\u20137.","journal-title":"Clin Oral Implants Res"},{"key":"6593_CR21","doi-asserted-by":"publisher","first-page":"9","DOI":"10.5125\/jkaoms.2016.42.1.9","volume":"42","author":"J-H Oh","year":"2016","unstructured":"Oh J-H, Fang Y, Jeong S-M, Choi B-H. The effect of low-speed drilling without irrigation on heat generation: an experimental study. J Korean Assoc Oral Maxillofac Surg. 2016;42:9\u201312.","journal-title":"J Korean Assoc Oral Maxillofac Surg"},{"key":"6593_CR22","doi-asserted-by":"publisher","first-page":"4251","DOI":"10.1007\/s00784-021-03939-z","volume":"25","author":"JC Bernabeu-Mira","year":"2021","unstructured":"Bernabeu-Mira JC, Soto-Pe\u00f1aloza D, Pe\u00f1arrocha-Diago M, Camacho-Alonso F, Rivas-Ballester R, Pe\u00f1arrocha-Oltra D. Low-speed drilling without irrigation versus conventional drilling for dental implant osteotomy preparation: a systematic review. Clin Oral Investig. 2021;25:4251\u201367.","journal-title":"Clin Oral Investig"},{"key":"6593_CR23","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1111\/clr.12341","volume":"26","author":"JL Calvo-Guirado","year":"2015","unstructured":"Calvo-Guirado JL, Delgado-Pe\u00f1a J, Mat\u00e9-S\u00e1nchez JE, Mareque Bueno J, Delgado-Ruiz RA, Romanos GE. Novel hybrid drilling protocol: evaluation for the implant healing \u2013 thermal changes, crestal bone loss, and bone-to-implant contact. Clin Oral Implants Res. 2015;26:753\u201360.","journal-title":"Clin Oral Implants Res"},{"key":"6593_CR24","first-page":"105","volume":"1","author":"K Bar\u0131\u015f","year":"2023","unstructured":"Bar\u0131\u015f K, Kar\u015f\u0131yaka Hendek M, Olgun E. Can a new cooling method be used in dental implant drilling? An in vitro pilot study. J Dent Sci Educ. 2023;1:105\u20138.","journal-title":"J Dent Sci Educ"},{"key":"6593_CR25","first-page":"405","volume":"46","author":"D Laurito","year":"2010","unstructured":"Laurito D, Lamazza L, Garreffa G, De Biase A. An alternative method to record rising temperatures during dental implant site preparation: a preliminary study using bovine bone. Ann Ist Super Sanita. 2010;46:405\u201310.","journal-title":"Ann Ist Super Sanita"},{"key":"6593_CR26","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1038\/s41563-020-00852-w","volume":"20","author":"J Mao","year":"2021","unstructured":"Mao J, Chen G, Ren Z. Thermoelectric cooling materials. Nat Mater. 2021;20:454\u201361.","journal-title":"Nat Mater"},{"key":"6593_CR27","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1002\/JPER.17-0502","volume":"89","author":"C Lajolo","year":"2018","unstructured":"Lajolo C, Valente NA, Romandini WG, Petruzzi M, Verdugo F, D\u2019Addona A. Bone heat generated using conventional implant drills versus piezosurgery unit during apical cortical plate perforation. J Periodontol. 2018;89:661\u20138.","journal-title":"J Periodontol"},{"key":"6593_CR28","doi-asserted-by":"publisher","first-page":"411","DOI":"10.5051\/jpis.2106040302","volume":"52","author":"Y-S Choi","year":"2022","unstructured":"Choi Y-S, Oh J-W, Lee Y, Lee D-W. Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model. J Periodontal Implant Sci. 2022;52:411\u201321.","journal-title":"J Periodontal Implant Sci"},{"key":"6593_CR29","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1007\/s12663-022-01800-8","volume":"22","author":"L Aquilanti","year":"2023","unstructured":"Aquilanti L, Antognoli L, Rappelli G, Di Felice R, Scalise L. Heat generation during initial osteotomy for implant site preparation: an in vitro measurement study. J Maxillofac Oral Surg. 2023;22:313\u201320.","journal-title":"J Maxillofac Oral Surg"},{"key":"6593_CR30","doi-asserted-by":"crossref","unstructured":"Gehrke SA, Arambur\u00fa J\u00fanior JS, P\u00e9rez\u2010Albacete Mart\u00ednez C, Ramirez Fernandez MP, Mat\u00e9 S\u00e1nchez de Val JE, Calvo\u2010Guirado JL. The influence of drill length and irrigation system on heat production during osteotomy preparation for dental implants: an ex\u00a0vivo study. Clin Oral Implants Res. 2018;29:772\u20138.","DOI":"10.1111\/clr.12827"},{"key":"6593_CR31","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1111\/j.1600-0501.2009.01654.x","volume":"20","author":"K Yoshida","year":"2009","unstructured":"Yoshida K, Uoshima K, Oda K, Maeda T. Influence of heat stress to matrix on bone formation. Clin Oral Implants Res. 2009;20:782\u201390.","journal-title":"Clin Oral Implants Res"},{"key":"6593_CR32","first-page":"e506","volume":"22","author":"A Sindel","year":"2017","unstructured":"Sindel A, Dereci \u00d6, Hatipo\u011flu M, Altay A, \u00d6zalp \u00d6, \u00d6zt\u00fcrk A. The effects of irrigation volume to the heat generation during implant surgery. Med Oral Patol Oral Cir Bucal. 2017;22:e506\u201311.","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"6593_CR33","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1111\/jopr.13370","volume":"31","author":"A Ashry","year":"2022","unstructured":"Ashry A, Elattar MS, Elsamni OA, Soliman IS. Effect of guiding sleeve design on intraosseous heat generation during implant site preparation (in vitro study). J Prosthodont. 2022;31:147\u201354.","journal-title":"J Prosthodont"},{"key":"6593_CR34","doi-asserted-by":"publisher","first-page":"3461","DOI":"10.3390\/ma13163461","volume":"13","author":"K Kniha","year":"2020","unstructured":"Kniha K, Heussen N, Weber E, M\u00f6hlhenrich SC, H\u00f6lzle F, Modabber A. Temperature threshold values of bone necrosis for thermo-explantation of dental implants\u2014a systematic review on preclinical in vivo research. Materials. 2020;13:3461.","journal-title":"Materials"},{"key":"6593_CR35","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1007\/s00784-020-03361-x","volume":"25","author":"K Kniha","year":"2021","unstructured":"Kniha K, Buhl EM, Hermanns-Sachweh B, Al-Sibai F, Bock A, Peters F, et al. Implant removal using thermal necrosis\u2014an in vitro pilot study. Clin Oral Investig. 2021;25:265\u201373.","journal-title":"Clin Oral Investig"},{"key":"6593_CR36","doi-asserted-by":"publisher","first-page":"22227","DOI":"10.1038\/s41598-022-25581-9","volume":"12","author":"K Kniha","year":"2022","unstructured":"Kniha K, Hermanns-Sachweh B, Al-Sibai F, Kneer R, M\u00f6hlhenrich SC, Heitzer M, et al. Effect of thermal osteonecrosis around implants in the rat tibia: numerical and histomorphometric results in context of implant removal. Sci Rep. 2022;12:22227.","journal-title":"Sci Rep"},{"key":"6593_CR37","doi-asserted-by":"publisher","first-page":"e234","DOI":"10.4317\/jced.57346","volume":"13","author":"R Raj","year":"2021","unstructured":"Raj R, Manju V, Kumar-Gopal V, Eswar M. Analysis of factors determining thermal changes at osteotomy site in dental implant placement - an in-vitro study. J Clin Exp Dent. 2021;13:e234-9.","journal-title":"J Clin Exp Dent"},{"key":"6593_CR38","doi-asserted-by":"publisher","first-page":"744","DOI":"10.2298\/VSP141208041M","volume":"73","author":"A Markovi\u0107","year":"2016","unstructured":"Markovi\u0107 A, Lazi\u0107 Z, Mi\u0161i\u0107 T, \u0160\u0107epanovi\u0107 M, Todorovi\u0107 A, Thakare K, et al. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites: Thermographic analysis on bovine ribs. Vojnosanit Pregl. 2016;73:744\u201350.","journal-title":"Vojnosanit Pregl"},{"key":"6593_CR39","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/s13191-014-0350-6","volume":"14","author":"SK Mishra","year":"2014","unstructured":"Mishra SK, Chowdhary R. Heat generated by dental implant drills during osteotomy\u2014a review: heat generated by dental implant drills. J Indian Prosthodont Soc. 2014;14:131\u201343.","journal-title":"J Indian Prosthodont Soc"},{"key":"6593_CR40","doi-asserted-by":"publisher","first-page":"1799","DOI":"10.1016\/j.matpr.2021.09.206","volume":"50","author":"RV Dahibhate","year":"2022","unstructured":"Dahibhate RV, Jaju SB. Effect of irrigation mode, volume, medium and drill on heat generation during implant surgery: a review. Mater Today Proc. 2022;50:1799\u2013803.","journal-title":"Mater Today Proc"},{"key":"6593_CR41","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1097\/ID.0000000000000607","volume":"26","author":"I Barrak","year":"2017","unstructured":"Barrak I, Jo\u00f3b-Fancsaly A, Varga E, Boa K, Piffko J. Effect of the combination of low-speed drilling and cooled irrigation fluid on intraosseous heat generation during guided surgical implant site preparation: an: in vitro: study. Implant Dent. 2017;26:541\u20136.","journal-title":"Implant Dent"},{"key":"6593_CR42","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1016\/j.ijom.2010.05.009","volume":"39","author":"S-Y Park","year":"2010","unstructured":"Park S-Y, Shin S-Y, Yang S-M, Kye S-B. Effect of implant drill design on the particle size of the bone collected during osteotomy. Int J Oral Maxillofac Surg. 2010;39:1007\u201311.","journal-title":"Int J Oral Maxillofac Surg"},{"key":"6593_CR43","doi-asserted-by":"publisher","first-page":"7819080","DOI":"10.1155\/2017\/7819080","volume":"2017","author":"H-C Lim","year":"2017","unstructured":"Lim H-C, Ha K-I, Hong J-Y, Han J-Y, Shin S-I, Shin S-Y, et al. Comparison of the bone harvesting capacity of an intraoral bone harvesting device and three different implant drills. Biomed Res Int. 2017;2017:7819080.","journal-title":"Biomed Res Int"},{"key":"6593_CR44","doi-asserted-by":"publisher","first-page":"468","DOI":"10.11607\/jomi.8534","volume":"36","author":"\u015e G\u00fcler","year":"2021","unstructured":"G\u00fcler \u015e, Bayrakdar SK, \u00d6\u011f\u00fct\u00fcc\u00fc U. A comparison of the autogenous bone collection capacity of two bur drill systems used in implant surgery with different bur diameters and lengths at different drilling speeds: an in vitro study. Int J Oral Maxillofac Implants. 2021;36:468\u201373.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"6593_CR45","first-page":"103","volume":"52","author":"WT Li","year":"2020","unstructured":"Li WT, Li P, Piao MZ, Zhang F, DI J. Study on bone volume harvested from the implant sites with different methods. Beijing Da Xue Xue Bao Yi Xue Ban. 2020;52:103\u20136.","journal-title":"Beijing Da Xue Xue Bao Yi Xue Ban"},{"key":"6593_CR46","doi-asserted-by":"publisher","first-page":"3944","DOI":"10.3390\/jcm12123944","volume":"12","author":"S Parvizi","year":"2023","unstructured":"Parvizi S, Cameron A, Tadakamadla S, Figueredo CMS, Reher P. A novel irrigation system to reduce heat generation during guided implantology: an in vitro study. J Clin Med. 2023;12:3944.","journal-title":"J Clin Med"},{"key":"6593_CR47","first-page":"139","volume":"11","author":"RM Jochum","year":"2000","unstructured":"Jochum RM, Reichart PA. Influence of multiple use of Timedur-titanium cannon drills: thermal response and scanning electron microscopic findings. Clin Oral Implants Res. 2000;11:139\u201343.","journal-title":"Clin Oral Implants Res"},{"key":"6593_CR48","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1177\/00037028231213889","volume":"78","author":"C Mein","year":"2024","unstructured":"Mein C, Jones JR, Tennick C, Williams A. Recognition of the presence of bone fractures through physicochemical changes in diagenetic bone. Appl Spectrosc. 2024;78:159\u201374.","journal-title":"Appl Spectrosc"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06593-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-06593-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06593-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T08:45:58Z","timestamp":1757321158000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-06593-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,29]]},"references-count":48,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6593"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-06593-z","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,29]]},"assertion":[{"value":"23 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1274"}}