{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T22:42:13Z","timestamp":1794264133187,"version":"4.9.0"},"reference-count":48,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,19]],"date-time":"2025-07-19T00:00:00Z","timestamp":1752883200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,19]],"date-time":"2025-07-19T00:00:00Z","timestamp":1752883200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>This study aims to evaluate the stress distribution in peri-implant bone, implant surfaces, and within the framework material under vertical and oblique loads, considering various angulations and abutment types of bendable one-piece implants in the All-on-4 concept.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A three-dimensional model of an edentulous mandible was constructed. Six different configurations were modeled according to prosthesis connection type and inclination of the posterior implants based on the All-on-4 protocol. Four one-piece implants were placed in each model and a cobalt-chromium frameworks with 14\u00a0mm cantilever lengths were designed. Under vertical and oblique loading conditions, maximum principal stress and minimum principal stress values were obtained for cortical and trabecular bone and von Mises stress values were calculated for implants and frameworks.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Implant angulation, connection type, and loading conditions affected stress distribution in the peri-implant bone, implants, and frameworks. Higher stress values were observed in posterior implants with increased angulation. Screw-retained models demonstrated greater stress values compared to cement-retained ones under both loading conditions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>For optimal stress distribution in peri-implant bone and frameworks, cement-retained prosthesis may be preferred, especially in cases with increased implant angulation in one-piece bendable systems. Additionally, careful consideration of posterior implant angulation and loading conditions is crucial to minimize the excessive stress and to enhance long-term stability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical trial number<\/jats:title>\n                    <jats:p>Not applicable.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-025-06610-1","type":"journal-article","created":{"date-parts":[[2025,7,19]],"date-time":"2025-07-19T12:53:26Z","timestamp":1752929606000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Biomechanical comparison of various implant inclinations and abutment types in a bendable implant system"],"prefix":"10.1186","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3357-3740","authenticated-orcid":false,"given":"Esra","family":"Bilgi-Ozyetim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7680-0376","authenticated-orcid":false,"given":"G\u00f6k\u00e7en","family":"Din\u00e7er","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-2330-7834","authenticated-orcid":false,"given":"Ammar","family":"Sulaiman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3081-9618","authenticated-orcid":false,"given":"S\u00fcleyman \u00c7a\u011fatay","family":"Dayan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8792-1977","authenticated-orcid":false,"given":"Sevcan","family":"Kurtulmus-Yilmaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7852-3915","authenticated-orcid":false,"given":"Onur","family":"Ge\u00e7kili","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,19]]},"reference":[{"key":"6610_CR1","doi-asserted-by":"crossref","unstructured":"Misch CE. Dental implant prosthetics. Elsevier Health Sciences. 2014.","DOI":"10.1016\/B978-0-323-07845-0.00016-6"},{"key":"6610_CR2","unstructured":"Anusavice KJ, Shen C, Rawls HR. Phillips\u2019 science of dental materials. Elsevier Health Sciences. 2012."},{"key":"6610_CR3","doi-asserted-by":"publisher","unstructured":"Hotinski E, Dudley J. Abutment screw loosening in angulation-correcting implants: an in vitro study. J Prosthet Dent. 2019;121(1):151\u20135. https:\/\/doi.org\/10.1016\/j.prosdent.2018.03.005","DOI":"10.1016\/j.prosdent.2018.03.005"},{"issue":"5","key":"6610_CR4","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1563\/aaid-joi-D-18-00305","volume":"45","author":"V Poletto-Neto","year":"2019","unstructured":"Poletto-Neto V, Tretto PHW, Zen BM, Bacchi A, Dos Santos MBF. Influence of implant inclination and prosthetic abutment type on the biomechanics of implant-supported fixed partial dentures. J Oral Implantol. 2019;45(5):343\u201350. https:\/\/doi.org\/10.1563\/aaid-joi-D-18-00305.","journal-title":"J Oral Implantol"},{"issue":"2","key":"6610_CR5","doi-asserted-by":"publisher","first-page":"150","DOI":"10.14219\/jada.archive.2011.0057","volume":"142","author":"J Cavallaro Jr","year":"2011","unstructured":"Cavallaro J Jr, Greenstein G. Angled implant abutments: a practical application of available knowledge. J Am Dent Assoc. 2011;142(2):150\u20138. https:\/\/doi.org\/10.14219\/jada.archive.2011.0057.","journal-title":"J Am Dent Assoc"},{"issue":"5","key":"6610_CR6","doi-asserted-by":"publisher","first-page":"388","DOI":"10.3290\/j.qi.a44368","volume":"51","author":"E Mumcu","year":"2020","unstructured":"Mumcu E, Dayan SC, Genceli E, Geckili O. Comparison of four-implant-retained overdentures and implant-supported fixed prostheses using the All-on-4 concept in the maxilla in terms of patient satisfaction, quality of life, and marginal bone loss: a 2-year retrospective study. Quintessence Int. 2020;51(5):388\u201396. https:\/\/doi.org\/10.3290\/j.qi.a44368.","journal-title":"Quintessence Int"},{"key":"6610_CR7","doi-asserted-by":"publisher","first-page":"103880","DOI":"10.1016\/j.compbiomed.2020.103880","volume":"123","author":"A Ayali","year":"2020","unstructured":"Ayali A, Altagar M, Ozan O, Kurtulmus-Yilmaz S. Biomechanical comparison of the All-on-4, M-4, and V-4 techniques in an atrophic maxilla: A 3D finite element analysis. Comput Biol Med. 2020;123:103880. https:\/\/doi.org\/10.1016\/j.compbiomed.2020.103880.","journal-title":"Comput Biol Med"},{"issue":"3","key":"6610_CR8","doi-asserted-by":"publisher","first-page":"217","DOI":"10.4103\/jips.jips_79_21","volume":"21","author":"SP Mehta","year":"2021","unstructured":"Mehta SP, Sutariya PV, Pathan MR, Upadhyay HH, Patel SR, Kantharia NDG. Clinical success between Tilted and axial implants in edentulous maxilla: A systematic review and meta-analysis. J Indian Prosthodont Soc. 2021;21(3):217\u201328. https:\/\/doi.org\/10.4103\/jips.jips_79_21.","journal-title":"J Indian Prosthodont Soc"},{"issue":"6","key":"6610_CR9","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1016\/j.prosdent.2021.12.020","volume":"130","author":"Q Yang","year":"2023","unstructured":"Yang Q, Guan X, Wang B, Zhang D, Bai J, Zhang X, Zhou Y. Implant survival rate and marginal bone loss with the all-on-4 immediate-loading strategy: A clinical retrospective study with 1 to 4 years of follow-up. J Prosthet Dent. 2023;130(6):849\u201357. https:\/\/doi.org\/10.1016\/j.prosdent.2021.12.020.","journal-title":"J Prosthet Dent"},{"issue":"14","key":"6610_CR10","doi-asserted-by":"publisher","first-page":"1606","DOI":"10.1080\/10255842.2021.1903450","volume":"24","author":"SC Dayan","year":"2021","unstructured":"Dayan SC, Geckili O. The influence of framework material on stress distribution in maxillary complete-arch fixed prostheses supported by four dental implants: a three-dimensional finite element analysis. Comput Methods Biomech Biomed Engin. 2021;24(14):1606\u201317. https:\/\/doi.org\/10.1080\/10255842.2021.1903450.","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"6","key":"6610_CR11","doi-asserted-by":"publisher","first-page":"836","DOI":"10.1111\/cid.12068","volume":"16","author":"SB Patzelt","year":"2014","unstructured":"Patzelt SB, Bahat O, Reynolds MA, Strub JR. The all-on\u2010four treatment concept: a systematic review. Clin Implant Dent Relat Res. 2014;16(6):836\u201355. https:\/\/doi.org\/10.1111\/cid.12068.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"3","key":"6610_CR12","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1177\/154405910308200316","volume":"82","author":"N Broggini","year":"2003","unstructured":"Broggini N, McManus LM, Hermann JS, Medina RU, Oates TW, Schenk RK, Cochran DL. Persistent acute inflammation at the implant-abutment interface. J Dent Res. 2003;82(3):232\u20137. https:\/\/doi.org\/10.1177\/154405910308200316.","journal-title":"J Dent Res"},{"issue":"3","key":"6610_CR13","doi-asserted-by":"publisher","first-page":"219","DOI":"10.4103\/jips.jips_19_17","volume":"17","author":"S Elakkiya","year":"2017","unstructured":"Elakkiya S, Ramesh AS, Prabhu K. Systematic analysis on the efficacy of bone enhancement methods used for success in dental implants. J Indian Prosthodont Soc. 2017;17(3):219\u201325. https:\/\/doi.org\/10.4103\/jips.jips_19_17.","journal-title":"J Indian Prosthodont Soc"},{"issue":"2","key":"6610_CR14","first-page":"226","volume":"22","author":"K Finne","year":"2007","unstructured":"Finne K, Rompen E, Toljanic J. Clinical evaluation of a prospective multicenter study on 1-piece implants. Part 1: marginal bone level evaluation after 1 year of follow-up. Int J Oral Maxillofac Implants. 2007;22(2):226\u201334.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"5","key":"6610_CR15","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1111\/jerd.12097","volume":"26","author":"G Iglhaut","year":"2014","unstructured":"Iglhaut G, Schwarz F, Winter RR, Mihatovic I, Stimmelmayr M, Schliephake H. Epithelial attachment and downgrowth on dental implant abutments\u2014a comprehensive review. J Esthet Restor Dent. 2014;26(5):324\u201331. https:\/\/doi.org\/10.1111\/jerd.12097.","journal-title":"J Esthet Restor Dent"},{"key":"6610_CR16","first-page":"028","volume":"4","author":"JO Agbaje","year":"2018","unstructured":"Agbaje JO, Diederich H. Minimal invasive concept for the rehabilitation of edentulous jaw with one-piece implants. Int J Case Rep Short Reviews. 2018;4:028\u201330.","journal-title":"Int J Case Rep Short Reviews"},{"issue":"3","key":"6610_CR17","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1034\/j.1600-0501.1996.070302.x","volume":"7","author":"CM Bollen","year":"1996","unstructured":"Bollen CM, Papaioanno W, Van Eldere J, Schepers E, Quirynen M, Van Steenberghe D. The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis. Clin Oral Implants Res. 1996;7(3):201\u201311. https:\/\/doi.org\/10.1034\/j.1600-0501.1996.070302.x.","journal-title":"Clin Oral Implants Res"},{"issue":"4","key":"6610_CR18","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1111\/cid.12769","volume":"21","author":"P Mal\u00f3","year":"2019","unstructured":"Mal\u00f3 P, de Ara\u00fajo Nobre M, Lopes A, Ferro A, Botto J. The All-on\u20104 treatment concept for the rehabilitation of the completely edentulous mandible: A longitudinal study with 10 to 18 years of follow\u2010up. Clin Implant Dent Relat Res. 2019;21(4):565\u201377. https:\/\/doi.org\/10.1111\/cid.12769.","journal-title":"Clin Implant Dent Relat Res"},{"key":"6610_CR19","doi-asserted-by":"publisher","first-page":"27","DOI":"10.11607\/ijp.5804","volume":"32","author":"P Pera","year":"2019","unstructured":"Pera P, Menini M, Pesce P, Bevilacqua M, Pera F, Tealdo T. Immediate versus delayed loading of dental implants supporting fixed full-arch maxillary prostheses: a 10-year follow-up report. Int J Prosthodont. 2019;32:27\u201331. https:\/\/doi.org\/10.11607\/ijp.5804.","journal-title":"Int J Prosthodont"},{"issue":"1","key":"6610_CR20","doi-asserted-by":"publisher","first-page":"10","DOI":"10.3390\/medicina58010010","volume":"58","author":"T Grandi","year":"2021","unstructured":"Grandi T, Signorini L. Rehabilitation of the completely edentulous mandible by all-on-four treatment concept: A retrospective cohort study with up to 10 years follow-up. Med (Kaunas). 2021;58(1):10. https:\/\/doi.org\/10.3390\/medicina58010010.","journal-title":"Med (Kaunas)"},{"issue":"1","key":"6610_CR21","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1186\/s40729-023-00511-0","volume":"9","author":"T Uesugi","year":"2023","unstructured":"Uesugi T, Shimoo Y, Munakata M, Sato D, Yamaguchi K, Fujimaki M, Malo P. The All-on-four concept for fixed full-arch rehabilitation of the edentulous maxilla and mandible: a longitudinal study in Japanese patients with 3\u201317-year follow-up and analysis of risk factors for survival rate. Int J Implant Dent. 2023;9(1):43. https:\/\/doi.org\/10.1186\/s40729-023-00511-0.","journal-title":"Int J Implant Dent"},{"issue":"1","key":"6610_CR22","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1186\/s12903-024-04091-2","volume":"24","author":"CRM Ibrahim","year":"2024","unstructured":"Ibrahim CRM, Sameh A, Askar O. A finite element analysis study on different angle correction designs for inclined implants in All-On-Four protocol. BMC Oral Health. 2024;24(1):331. https:\/\/doi.org\/10.1186\/s12903-024-04091-2.","journal-title":"BMC Oral Health"},{"issue":"1","key":"6610_CR23","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1186\/s12903-022-02520-8","volume":"22","author":"Q Wang","year":"2022","unstructured":"Wang Q, Zhang ZZ, Bai SZ, Zhang SF. Biomechanical analysis of stress around the Tilted implants with different cantilever lengths in all-on-4 concept. BMC Oral Health. 2022;22(1):469. https:\/\/doi.org\/10.1186\/s12903-022-02520-8.","journal-title":"BMC Oral Health"},{"issue":"3","key":"6610_CR24","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1111\/j.1532-849X.2012.00928.x","volume":"22","author":"DR Prithviraj","year":"2013","unstructured":"Prithviraj DR, Gupta V, Muley N, Sandhu P. One-piece implants: placement timing, surgical technique, loading protocol, and marginal bone loss. J Prosthodontics: Implant Esthetic Reconstr Dentistry. 2013;22(3):237\u201344. https:\/\/doi.org\/10.1111\/j.1532-849X.2012.00928.x.","journal-title":"J Prosthodontics: Implant Esthetic Reconstr Dentistry"},{"issue":"4","key":"6610_CR25","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1111\/j.1600-0501.2004.01025.x","volume":"15","author":"M Cavit \u00c7ehreli","year":"2004","unstructured":"Cavit \u00c7ehreli M, Ak\u00e7a K, \u0130plik\u00e7io\u011flu H. Force transmission of one-and two\u2010piece morse\u2010taper oral implants: a nonlinear finite element analysis. Clin Oral Implants Res. 2004;15(4):481\u20139. https:\/\/doi.org\/10.1111\/j.1600-0501.2004.01025.x.","journal-title":"Clin Oral Implants Res"},{"issue":"2","key":"6610_CR26","doi-asserted-by":"publisher","first-page":"51","DOI":"10.21608\/adjalexu.2018.57624","volume":"43","author":"SM Moustafa","year":"2018","unstructured":"Moustafa SM, Elattar MS, Ahmed TM. Comparison of stresses transmitted to one-piece and two-piece narrow-diameter implants in mandibular over dentures (a finite element stress analysis). Alexandria Dent J. 2018;43(2):51\u20136.","journal-title":"Alexandria Dent J"},{"issue":"1","key":"6610_CR27","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1186\/s12903-022-02228-9","volume":"22","author":"AMA Mohamed","year":"2022","unstructured":"Mohamed AMA, Askar MG, El Homossany MEMB. Stresses induced by one-piece and two-piece dental implants in All-on-4\u00ae implant supported prosthesis under simulated lateral occlusal loading: nonlinear finite element analysis study. BMC Oral Health. 2022;22(1):196. https:\/\/doi.org\/10.1186\/s12903-022-02228-9.","journal-title":"BMC Oral Health"},{"issue":"2","key":"6610_CR28","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1563\/AAID-JOI-D-12-00312","volume":"41","author":"G Sannino","year":"2015","unstructured":"Sannino G. All-on-4 concept: a 3-dimensional finite element analysis. J Oral Implantol. 2015;41(2):163\u201371. https:\/\/doi.org\/10.1563\/AAID-JOI-D-12-00312.","journal-title":"J Oral Implantol"},{"issue":"1","key":"6610_CR29","doi-asserted-by":"publisher","first-page":"12","DOI":"10.3390\/dj10010012","volume":"10","author":"JPM Tribst","year":"2022","unstructured":"Tribst JPM, Campanelli de Morais D, Melo de Matos JD, Lopes GDRS, Dal Piva AMDO, Souto Borges AL, Ausiello P. Influence of framework material and posterior implant angulation in full-arch all-on-4 implant-supported prosthesis stress concentration. Dent J (Basel). 2022;10(1):12. https:\/\/doi.org\/10.3390\/dj10010012.","journal-title":"Dent J (Basel)"},{"issue":"3","key":"6610_CR30","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1563\/AAID-JOI-D-10-00146","volume":"38","author":"R Shadid","year":"2012","unstructured":"Shadid R, Sadaqa N. A comparison between screw-and cement-retained implant prostheses. A literature review. J Oral Implantol. 2012;38(3):298\u2013307. https:\/\/doi.org\/10.1563\/AAID-JOI-D-10-00146.","journal-title":"J Oral Implantol"},{"issue":"10","key":"6610_CR31","doi-asserted-by":"publisher","first-page":"1278","DOI":"10.1111\/clr.12954","volume":"28","author":"N Staubli","year":"2017","unstructured":"Staubli N, Walter C, Schmidt JC, Weiger R, Zitzmann NU. Excess cement and the risk of peri-implant disease\u2013a systematic review. Clin Oral Implants Res. 2017;28(10):1278\u201390. https:\/\/doi.org\/10.1111\/clr.12954.","journal-title":"Clin Oral Implants Res"},{"issue":"5","key":"6610_CR32","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1111\/j.1600-0501.2009.01706.x","volume":"20","author":"M Aglietta","year":"2009","unstructured":"Aglietta M, Siciliano VI, Zwahlen M, Br\u00e4gger U, Pjetursson BE, Lang NP, Salvi GE. A systematic review of the survival and complication rates of implant supported fixed dental prostheses with cantilever extensions after an observation period of at least 5 years. Clin Oral Implants Res. 2009;20(5):441\u201351. https:\/\/doi.org\/10.1111\/j.1600-0501.2009.01706.x.","journal-title":"Clin Oral Implants Res"},{"issue":"6","key":"6610_CR33","doi-asserted-by":"publisher","first-page":"1479","DOI":"10.1016\/j.prosdent.2014.06.010","volume":"112","author":"GC Silva","year":"2014","unstructured":"Silva GC, Cornacchia TM, de Magalh\u00e3es CS, Bueno AC, Moreira AN. Biomechanical evaluation of screw-and cement-retained implant-supported prostheses: a nonlinear finite element analysis. J Prosthet Dent. 2014;112(6):1479\u201388. https:\/\/doi.org\/10.1016\/j.prosdent.2014.06.010.","journal-title":"J Prosthet Dent"},{"issue":"4","key":"6610_CR34","doi-asserted-by":"publisher","first-page":"1110","DOI":"10.1097\/SCS.0b013e3181e1b46e","volume":"21","author":"EP Pellizzer","year":"2010","unstructured":"Pellizzer EP, Tonella BP, Ferra\u00e7o R, Falc\u00f3n-Antenucci RM, de Carvalho PSP, Alves-Rezende MCR. Photoelastic stress analysis in screwed and cemented implant-supported dentures with external hexagon implants. J Craniofac Surg. 2010;21(4):1110\u20133. https:\/\/doi.org\/10.1097\/SCS.0b013e3181e1b46e.","journal-title":"J Craniofac Surg"},{"issue":"7","key":"6610_CR35","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1097\/SCS.0b013e3182597c09","volume":"23","author":"FA de Aguiar Jr","year":"2012","unstructured":"de Aguiar FA Jr, Tiossi R, Macedo AP, de Mattos MDGC, Ribeiro RF, Rodrigues RCS. Photoelastic analysis of stresses transmitted by universal cast to long abutment on implant-supported single restorations under static occlusal loads. J Craniofac Surg. 2012;23(7):77\u201381. https:\/\/doi.org\/10.1097\/SCS.0b013e3182597c09.","journal-title":"J Craniofac Surg"},{"issue":"1","key":"6610_CR36","doi-asserted-by":"publisher","first-page":"27","DOI":"10.11607\/jomi.2442","volume":"28","author":"BT Bal","year":"2013","unstructured":"Bal BT, \u00c7a\u011flar A, Ayd\u0131n C, Y\u0131lmaz H, Banko\u011flu M, Eser A. Finite element analysis of stress distribution with splinted and nonsplinted maxillary anterior fixed prostheses supported by zirconia or titanium implants. Int J Oral Maxillofac Implants. 2013;28(1):27\u201338. https:\/\/doi.org\/10.11607\/jomi.2442.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"6","key":"6610_CR37","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1067\/mpr.2001.115251","volume":"85","author":"JP Geng","year":"2001","unstructured":"Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent. 2001;85(6):585\u201398. https:\/\/doi.org\/10.1067\/mpr.2001.115251.","journal-title":"J Prosthet Dent"},{"issue":"5","key":"6610_CR38","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1016\/j.prosdent.2015.04.018","volume":"114","author":"LB Torcato","year":"2015","unstructured":"Torcato LB, Pellizzer EP, Verri FR, Falc\u00f3n-Antenucci RM, J\u00fanior JFS, de Faria Almeida DA. Influence of parafunctional loading and prosthetic connection on stress distribution: a 3D finite element analysis. J Prosthet Dent. 2015;114(5):644\u201351. https:\/\/doi.org\/10.1016\/j.prosdent.2015.04.018.","journal-title":"J Prosthet Dent"},{"key":"6610_CR39","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1016\/j.msec.2014.01.013","volume":"37","author":"LP Faverani","year":"2014","unstructured":"Faverani LP, Bar\u00e3o VAR, Ramalho-Ferreira G, Delben JA, Ferreira MB, J\u00fanior IRG, Assun\u00e7\u00e3o WG. The influence of bone quality on the Biomechanical behavior of full-arch implant-supported fixed prostheses. Mater Sci Engineering: C. 2014;37:164\u201370. https:\/\/doi.org\/10.1016\/j.msec.2014.01.013.","journal-title":"Mater Sci Engineering: C"},{"issue":"4","key":"6610_CR40","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1111\/cid.12024","volume":"16","author":"D Ozdemir Do\u011fan","year":"2014","unstructured":"Ozdemir Do\u011fan D, Polat NT, Polat S, \u015eeker E, G\u00fcl EB. Evaluation of All-on\u2010Four concept and alternative designs with 3D finite element analysis method. Clin Implant Dent Relat Res. 2014;16(4):501\u201310. https:\/\/doi.org\/10.1111\/cid.12024.","journal-title":"Clin Implant Dent Relat Res"},{"key":"6610_CR41","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1111\/cid.12129","volume":"17","author":"EO Almeida","year":"2015","unstructured":"Almeida EO, Rocha EP, J\u00fanior ACF, Anchieta RB, Poveda R, Gupta N, Coelho PG. Tilted and short implants supporting fixed prosthesis in an atrophic maxilla: a 3D-FEA Biomechanical evaluation. Clin Implant Dent Relat Res. 2015;17:332\u201342. https:\/\/doi.org\/10.1111\/cid.12129.","journal-title":"Clin Implant Dent Relat Res"},{"key":"6610_CR42","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1016\/j.msec.2016.07.059","volume":"69","author":"CLB Bhering","year":"2016","unstructured":"Bhering CLB, Mesquita MF, Kemmoku DT, Noritomi PY, Consani RLX, Bar\u00e3o VAR. Comparison between all-on-four and all-on-six treatment concepts and framework material on stress distribution in atrophic maxilla: A prototyping guided 3D-FEA study. Mater Sci Eng C Mater Biol Appl. 2016;69:715\u201325. https:\/\/doi.org\/10.1016\/j.msec.2016.07.059.","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"issue":"1","key":"6610_CR43","doi-asserted-by":"publisher","first-page":"64","DOI":"10.11607\/jomi.6201","volume":"33","author":"O Ozan","year":"2018","unstructured":"Ozan O, Kurtulmus-Yilmaz S. Biomechanical comparison of different implant inclinations and cantilever lengths in All-on-4 treatment concept by Three-Dimensional finite element analysis. Int J Oral Maxillofac Implants. 2018;33(1):64\u201371. https:\/\/doi.org\/10.11607\/jomi.6201.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"3","key":"6610_CR44","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1016\/j.jds.2012.04.006","volume":"8","author":"HS Chang","year":"2013","unstructured":"Chang HS, Chen YC, Hsieh YD, Hsu ML. Stress distribution of two commercial dental implant systems: A three-dimensional finite element analysis. J Dent Sci. 2013;8(3):261\u201371. https:\/\/doi.org\/10.1016\/j.jds.2012.04.006.","journal-title":"J Dent Sci"},{"issue":"2","key":"6610_CR45","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1563\/AAID-JOI-D-11-00205","volume":"41","author":"JMFK Takahashi","year":"2015","unstructured":"Takahashi JMFK, Dayrell AC, Consani RLX, de Arruda N\u00f3bilo MA, Henriques GEP, Mesquita MF. Stress evaluation of implant-abutment connections under different loading conditions: a 3D finite element study. J Oral Implantol. 2015;41(2):133\u20137. https:\/\/doi.org\/10.1563\/AAID-JOI-D-11-00205.","journal-title":"J Oral Implantol"},{"issue":"3","key":"6610_CR46","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1016\/j.prosdent.2017.03.008","volume":"119","author":"N Kaleli","year":"2018","unstructured":"Kaleli N, Sarac D, K\u00fcl\u00fcnk S, \u00d6zt\u00fcrk \u00d6. Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: A three-dimensional finite element analysis study. J Prosthet Dent. 2018;119(3):437\u201345. https:\/\/doi.org\/10.1016\/j.prosdent.2017.03.008.","journal-title":"J Prosthet Dent"},{"issue":"10","key":"6610_CR47","doi-asserted-by":"publisher","first-page":"2666","DOI":"10.3390\/ma14102666","volume":"14","author":"JH Lee","year":"2021","unstructured":"Lee JH, Jang HY, Lee SY. Finite element analysis of dental implants with zirconia crown restorations: conventional cement-retained vs. cementless screw-retained. Mater (Basel). 2021;14(10):2666. https:\/\/doi.org\/10.3390\/ma14102666.","journal-title":"Mater (Basel)"},{"issue":"4","key":"6610_CR48","doi-asserted-by":"publisher","first-page":"350","DOI":"10.1046\/j.1365-2842.2002.00872.x","volume":"29","author":"K Ak\u00e7a","year":"2002","unstructured":"Ak\u00e7a K, Iplik\u00e7io\u011flu H. Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism. J Oral Rehabil. 2002;29(4):350\u20136. https:\/\/doi.org\/10.1046\/j.1365-2842.2002.00872.x.","journal-title":"J Oral Rehabil"}],"updated-by":[{"DOI":"10.1186\/s12903-026-10416-0","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T00:00:00Z","timestamp":1794182400000}}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06610-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-06610-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06610-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T10:34:36Z","timestamp":1794220476000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-06610-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,19]]},"references-count":48,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6610"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-06610-1","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,19]]},"assertion":[{"value":"21 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 November 2026","order":5,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":6,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1186\/s12903-026-10416-0","URL":"https:\/\/doi.org\/10.1186\/s12903-026-10416-0","order":8,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study protocol was approved by the Istanbul Yeni Yuzyil University Science and Health Sciences Research Ethics Committee (No. 2022\/05-860).","order":1,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"1213"}}