{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T11:38:54Z","timestamp":1791632334202,"version":"4.3.4"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T00:00:00Z","timestamp":1756166400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T00:00:00Z","timestamp":1756166400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100018778","name":"Al-Azhar University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100018778","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Monolithic zirconia fixed partial dentures (FPDs) have gained popularity due to their high strength, biocompatibility and reduced veneer chipping compared to bilayered restorations. However, the connector region remains a critical point of mechanical failure, especially in long span implant supported FPDs subjected to high masticatory forces. The purpose of this in vitro study was to compare the fracture resistance of implant-supported Y-TZP (yttria-stabilized tetragonal zirconia polycrystal) fixed partial dentures (FPDs) with two connector sizes (9\u00a0mm\u00b2 and 12\u00a0mm\u00b2) and two connector cross-sectional shapes (oval and circular).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Twenty-eight four-unit posterior implant-supported monolithic zirconia FPDs were fabricated. They were divided into two equal groups (<jats:italic>n<\/jats:italic>\u2009=\u200914) based on connector cross-sectional shape (oval vs. circular), each further subdivided by connector size (9\u00a0mm\u00b2 or 12\u00a0mm\u00b2, <jats:italic>n<\/jats:italic>\u2009=\u20097 per subgroup). A static fracture test was performed by applying an occlusal load at a crosshead speed of 1\u00a0mm\/min until failure, and the fracture resistance (load to fracture) was recorded. The data distribution was first checked with the Kolmogorov-Smirnov and Shapiro-Wilk tests, which confirmed that the fracture resistance values followed a normal (parametric) distribution. A two-way analysis of variance (ANOVA) was performed to assess the effects of the connector size (9\u00a0mm\u00b2 vs. 12\u00a0mm\u00b2), connector cross-section (oval vs. circular), and their interaction on the mean fracture resistance. The significance level was set at \u03b1\u2009=\u20090.05.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Regardless of cross-sectional shape, the 9\u00a0mm\u00b2 connector groups showed significantly lower mean fracture resistance than the 12\u00a0mm\u00b2 connector groups. Regardless of connector size, the oval cross-section groups showed significantly higher mean fracture resistance than the circular groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Based on the findings of this in vitro study, it can be concluded that increasing the connector cross-sectional area and using an oval connector shape both enhance the fracture resistance of long-span monolithic zirconia FPDs.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s12903-025-06743-3","type":"journal-article","created":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T09:46:01Z","timestamp":1756201561000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Effect of connector size and configuration on the fracture resistance of a long-span implant-supported monolithic zirconia fixed partial denture (An in vitro Study)"],"prefix":"10.1186","volume":"25","author":[{"given":"Alaa M.","family":"Khorshed","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lomaya","family":"Ghanem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tamer E.","family":"Shokry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,26]]},"reference":[{"issue":"2","key":"6743_CR1","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1111\/jopr.12066","volume":"23","author":"JF Esquivel-Upshaw","year":"2013","unstructured":"Esquivel-Upshaw JF, Clark AE, Shuster JJ, Anusavice KJ. Randomized clinical trial of implant-supported ceramic-ceramic and metal-ceramic fixed dental prostheses: preliminary results. J Prosthodont. 2013;23(2):73\u201382.","journal-title":"J Prosthodont"},{"issue":"4","key":"6743_CR2","doi-asserted-by":"publisher","first-page":"e155","DOI":"10.1016\/j.dental.2016.12.010","volume":"33","author":"RF Villefort","year":"2017","unstructured":"Villefort RF, Amaral M, Pereira GK, Campos TM, Zhang Y, Bottino MA. Effects of two grading techniques of zirconia material on the fatigue limit of full-contour 3-unit fixed dental prostheses. Dent Mater. 2017;33(4):e155\u201364.","journal-title":"Dent Mater"},{"issue":"2","key":"6743_CR3","doi-asserted-by":"publisher","first-page":"119","DOI":"10.21608\/jfcr.2024.269593.1073","volume":"4","author":"R Negm","year":"2024","unstructured":"Negm R, Shokry T, Ghanem L. Effect of Cyclic loading on the fracture resistance of bilayered 3Y-TZP and monolithic gradient 5Y-TZP\/3Y-TZP zirconia-based fixed partial denture (in-vitro study). J Fundamental Clin Res. 2024;4(2):119\u201334.","journal-title":"J Fundamental Clin Res"},{"key":"6743_CR4","doi-asserted-by":"publisher","first-page":"672","DOI":"10.3390\/ma15020672","volume":"15","author":"M Gseibat","year":"2022","unstructured":"Gseibat M, Sevilla P, Lopez-Suarez C, Rodr\u00edguez V, Pel\u00e1ez J, Su\u00e1rez MJ. Prospective clinical evaluation of posterior third-generation monolithic zirconia crowns fabricated with complete digital workflow: Two-year follow-up. Materials. 2022;15:672.","journal-title":"Materials"},{"key":"6743_CR5","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1016\/j.dental.2005.12.008","volume":"23","author":"AR Studart","year":"2007","unstructured":"Studart AR, Filser F, Kocher P, Gauckler LJ. Fatigue of zirconia under Cyclic loading in water and its implications for the design of dental bridges. Dent Mater. 2007;23:106\u201314.","journal-title":"Dent Mater"},{"issue":"3","key":"6743_CR6","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/S0022-3913(12)60051-1","volume":"107","author":"AJ Raigrodski","year":"2012","unstructured":"Raigrodski AJ, Hillstead MB, Meng GK, Chung KH. Survival and complications of zirconia-based fixed dental prostheses: A systematic review. J Prosthet Dent. 2012;107(3):170\u20137.","journal-title":"J Prosthet Dent"},{"issue":"4","key":"6743_CR7","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1080\/13102818.2016.1177470","volume":"30","author":"\u00d6 Malkondu","year":"2016","unstructured":"Malkondu \u00d6, Tinastepe N, Akan E, Kazazo\u011flu E. An overview of monolithic zirconia in dentistry. Biotechnol Biotechnol Equip. 2016;30(4):644\u201352.","journal-title":"Biotechnol Biotechnol Equip"},{"issue":"Suppl 16","key":"6743_CR8","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1111\/clr.13306","volume":"29","author":"BE Pjetursson","year":"2018","unstructured":"Pjetursson BE, Valente NA, Strasding M, Zwahlen M, Liu S, Sailer I. A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic single crowns. Clin Oral Implants Res. 2018;29(Suppl 16):199\u2013214.","journal-title":"Clin Oral Implants Res"},{"issue":"2","key":"6743_CR9","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.prosdent.2015.06.022","volume":"115","author":"TA Hamza","year":"2016","unstructured":"Hamza TA, Attia MA, El-Hossary MMK, Mosleh IE, Shokry TE, Wee AG. Flexural strength of small connector designs of zirconia-based partial fixed dental prostheses. J Prosthet Dent. 2016;115(2):224\u20139.","journal-title":"J Prosthet Dent"},{"issue":"4","key":"6743_CR10","doi-asserted-by":"publisher","first-page":"2835","DOI":"10.21608\/edj.2017.76336","volume":"63","author":"M Abdullah","year":"2017","unstructured":"Abdullah M, Helal D. Effect of connector surface area and type of cement on fracture resistance of full-contoured monolithic CAD\/CAM zirconia fixed partial dentures. Egypt Dent J. 2017;63(4):2835\u201346.","journal-title":"Egypt Dent J"},{"key":"6743_CR11","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1590\/S1678-77572009000500032","volume":"17","author":"O Inan","year":"2009","unstructured":"Inan O, Se\u00e7ilmis A, Eraslan O. Effect of Pontic framework design on the fracture resistance of implant-supported all-ceramic fixed partial dentures. J Appl Oral Sci. 2009;17:533\u20138.","journal-title":"J Appl Oral Sci"},{"key":"6743_CR12","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1111\/j.1532-849X.2007.00287.x","volume":"17","author":"M Tsumita","year":"2008","unstructured":"Tsumita M, Kokubo Y, von Vult P, Fukushima S. Effect of framework shape on the fracture strength of implant-supported all-ceramic fixed partial dentures in the molar region. J Prosthodont. 2008;17:274\u201385.","journal-title":"J Prosthodont"},{"issue":"9","key":"6743_CR13","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1111\/j.1365-2842.2007.01770.x","volume":"34","author":"C Larsson","year":"2007","unstructured":"Larsson C, Holm L, L\u00f6vgren N, Kokubo Y, Vult von Steyern P. Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter: an in-vitro study. J Rehabil. 2007;34(9):702\u20139.","journal-title":"J Rehabil"},{"issue":"8","key":"6743_CR14","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1111\/j.1365-2842.2009.01969.x","volume":"36","author":"M Schmitter","year":"2009","unstructured":"Schmitter M, Mussotter K, Rammelsberg P, Stober T, Ohlmann B, Gabbert O. Clinical performance of extended zirconia frameworks for fixed dental prostheses: Two-year results. J Rehabil. 2009;36(8):610\u20135.","journal-title":"J Rehabil"},{"key":"6743_CR15","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1177\/154405910208100909","volume":"81","author":"W Oh","year":"2002","unstructured":"Oh W, Gotzen N, Anusavice KJ. Influence of connector design on fracture probability of ceramic fixed-partial dentures. J Dent Res. 2002;81:623\u20137.","journal-title":"J Dent Res"},{"issue":"1","key":"6743_CR16","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.tdj.2015.01.001","volume":"12","author":"RD Lakshmi","year":"2015","unstructured":"Lakshmi RD, Abraham A, Sekar V, Hariharan A. Influence of connector dimensions on the stress distribution of monolithic zirconia and lithium-di-silicate inlay-retained fixed dental prostheses: A 3D finite element analysis. Tanta Dent J. 2015;12(1):56\u201364.","journal-title":"Tanta Dent J"},{"key":"6743_CR17","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1111\/j.1834-7819.2011.01341.x","volume":"56","author":"MC Thompson","year":"2011","unstructured":"Thompson MC, Thompson KM, Swain M. The all-ceramic, inlay-supported fixed partial denture. Part 2. Fixed partial denture design: A finite element analysis. Aust Dent J. 2011;56:302\u201311.","journal-title":"Aust Dent J"},{"issue":"3","key":"6743_CR18","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/S0022-3913(09)60022-6","volume":"101","author":"K Plengsombut","year":"2009","unstructured":"Plengsombut K, Brewer JD, Monaco EA, Davis EL. Effect of two connector designs on the fracture resistance of all-ceramic core materials for fixed dental prostheses. J Prosthet Dent. 2009;101(3):166\u201373.","journal-title":"J Prosthet Dent"},{"issue":"4","key":"6743_CR19","doi-asserted-by":"publisher","first-page":"218","DOI":"10.34172\/joddd.2020.039","volume":"14","author":"A Hafezeqoran","year":"2020","unstructured":"Hafezeqoran A, Koodaryan R, Hemmati Y, Akbarzadeh A. Effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prosthesis. J Dent Res Dent Clin Dent Prospects. 2020;14(4):218.","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"issue":"4","key":"6743_CR20","first-page":"179","volume":"37","author":"DJ Mahmood","year":"2013","unstructured":"Mahmood DJ, Linderoth EH, Von Steyern PV, Wennerberg A. Fracture strength of all-ceramic (Y-TZP) three- and four-unit fixed dental prostheses with different connector design and production history. Swed Dent J. 2013;37(4):179\u201387.","journal-title":"Swed Dent J"},{"issue":"2","key":"6743_CR21","doi-asserted-by":"publisher","first-page":"175","DOI":"10.3758\/BF03193146","volume":"39","author":"F Faul","year":"2007","unstructured":"Faul F, et al. G* power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39(2):175\u201391.","journal-title":"Behav Res Methods"},{"key":"6743_CR22","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s40729-019-0159-5","volume":"5","author":"M Osman","year":"2019","unstructured":"Osman M, Ziada H, Abubakr Hassan N, Suleiman A. Implant impression accuracy of parallel and non-parallel implants: A comparative in-vitro analysis of open and closed tray techniques. Int J Implant Dentistry. 2019;5:4.","journal-title":"Int J Implant Dentistry"},{"issue":"1","key":"6743_CR23","doi-asserted-by":"publisher","first-page":"7","DOI":"10.4103\/tdj.tdj_29_17","volume":"15","author":"A Bedair","year":"2018","unstructured":"Bedair A, Korsel A, Elshahawy W. Flexural strength of four-unit implant-supported ceramic veneered Zircon and full Zircon fixed dental prosthesis. Tanta Dent J. 2018;15(1):7.","journal-title":"Tanta Dent J"},{"issue":"1","key":"6743_CR24","doi-asserted-by":"publisher","first-page":"15","DOI":"10.21608\/ajdsm.2022.115225.1286","volume":"26","author":"M El Gohary","year":"2023","unstructured":"El Gohary M, Metwally M, Shokry T. Evaluation of fracture resistance of long-span implant-supported fixed dental prostheses fabricated from different CAD\/CAM materials. Al-Azhar J Dent Sci. 2023;26(1):15\u201325.","journal-title":"Al-Azhar J Dent Sci"},{"key":"6743_CR25","doi-asserted-by":"crossref","unstructured":"Safa Ali, Manhal A, Majeed. Trueness of intraoral scanners: Its impact on the trueness and marginal and internal discrepancies of fabricated crowns (A comparative in vitro study). Research Square 2024, PREPRINT (Version 1).","DOI":"10.21203\/rs.3.rs-4401482\/v1"},{"key":"6743_CR26","doi-asserted-by":"publisher","unstructured":"Kale E, Yilmaz B, \u015eeker E. Effect of fabrication stages and cementation on the marginal fit of CAD-CAM monolithic zirconia crowns. J Prosthet Dentistry. 118. https:\/\/doi.org\/10.1016\/j.prosdent.2017.01.004","DOI":"10.1016\/j.prosdent.2017.01.004"},{"issue":"8","key":"6743_CR27","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.1016\/j.dental.2007.12.006","volume":"24","author":"B Taskonak","year":"2008","unstructured":"Taskonak B, Yan J, Mecholsky JJ, Sertg\u00f6z A, Ko\u00e7ak A. Fractographic analyses of zirconia-based fixed partial dentures. Dent Mater. 2008;24(8):1077\u201382.","journal-title":"Dent Mater"},{"key":"6743_CR28","doi-asserted-by":"publisher","first-page":"104276","DOI":"10.1016\/j.jdent.2022.104271","volume":"125","author":"A Skjold","year":"2022","unstructured":"Skjold A, Schriwer C, Gjerdet NR, \u00d8ilo M. Fractographic analysis of 35 clinically fractured bi-layered and monolithic zirconia crowns. J Dent. 2022;125:104276.","journal-title":"J Dent"},{"issue":"1","key":"6743_CR29","doi-asserted-by":"publisher","first-page":"839","DOI":"10.21608\/edj.2021.103069.1842","volume":"68","author":"A Alzhairi","year":"2022","unstructured":"Alzhairi A, Hamdy A, Hamza F. Fractographic analysis of monolithic and bilayered zirconia after thermo-mechanical fatigue and fracture strength test. Egypt Dent J. 2022;68(1):839\u201345.","journal-title":"Egypt Dent J"},{"issue":"1","key":"6743_CR30","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1177\/2320206819831560","volume":"10","author":"AS Alayad","year":"2019","unstructured":"Alayad AS. Ceramic fracture in bilayered All-ceramic indirect restoration: A review of the literature. J Adv Oral Res. 2019;10(1):5\u201312. https:\/\/doi.org\/10.1177\/2320206819831560.","journal-title":"J Adv Oral Res"},{"key":"6743_CR31","doi-asserted-by":"publisher","first-page":"8451445","DOI":"10.1155\/2022\/8451445","volume":"2022","author":"HY Shi","year":"2022","unstructured":"Shi HY, Pang R, Yang J, Fan D, Cai H, Jiang H, Han J, Lee ES, Sun Y. Overview of several typical ceramic materials for restorative dentistry. Biomed Res Int. 2022;2022:8451445.","journal-title":"Biomed Res Int"},{"key":"6743_CR32","first-page":"701","volume":"27","author":"P Kamposiora","year":"1996","unstructured":"Kamposiora P, Papavasiliou G, Bayne SC, et al. Stress concentration in all-ceramic posterior fixed partial dentures. Quintessence Int. 1996;27:701\u20136.","journal-title":"Quintessence Int"},{"issue":"1","key":"6743_CR33","doi-asserted-by":"publisher","first-page":"13","DOI":"10.4103\/0972-4052.52866","volume":"9","author":"AR Correia","year":"2009","unstructured":"Correia AR, Fernandes JC, Campos JC, Vaz MA, Ramos NV, Martins da Silva JP. Effect of connector design on the stress distribution of a cantilever fixed partial denture. J Indian Prosthodontic Soc. 2009;9(1):13\u20137.","journal-title":"J Indian Prosthodontic Soc"},{"key":"6743_CR34","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1111\/jopr.13601","volume":"32","author":"RJ Coello","year":"2023","unstructured":"Coello RJ, Aita-Holmes C, Dimalanta WG, Wenger K. An in vitro trial on the effect of arch form on connector size requirements in long-span anterior zirconia fixed dental prostheses. J Prosthodont. 2023;32:534\u20139.","journal-title":"J Prosthodont"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06743-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-06743-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-06743-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,9]],"date-time":"2025-09-09T16:27:25Z","timestamp":1757435245000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcoralhealth.biomedcentral.com\/articles\/10.1186\/s12903-025-06743-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,26]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6743"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-06743-3","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,26]]},"assertion":[{"value":"22 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable (In vitro study).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1375"}}