{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T04:27:34Z","timestamp":1791433654091,"version":"4.3.3"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T00:00:00Z","timestamp":1765324800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T00:00:00Z","timestamp":1768348800000},"content-version":"vor","delay-in-days":35,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100024743","name":"Suez Canal University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100024743","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aim<\/jats:title>\n                    <jats:p>The effect of 3D printing parameters on the marginal fit and fracture resistance of 3D printed provisional crowns is not clear. The objective of this research was to use different printing orientations and layer thicknesses to build 3D printed provisional crowns and to evaluate the marginal fit and fracture resistance of it.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      A maxillary first premolar resin tooth was reduced for all-ceramic tooth preparation then was scanned using intraoral scanner. 60 dies were printed using Digital Light Processing (DLP) 3D printer. One of the printed dies was scanned. The design of the crown was made then the design was exported to 3D printing software. 60 provisional resin crowns were printed using DLP 3D printer. 36 Provisional crowns were divided into 3 groups(\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200912) according to the printing orientation used: group A (0\u00b0), group B (90\u00b0) and group C (30\u00b0)0.24 Provisional crowns were divided into 2 groups (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200912) according to the layer thickness used: group D (50\u00a0\u03bcm) and group E (100\u00a0\u03bcm). Absolute marginal discrepancies (AMD) were measured using stereomicroscope. Fracture resistance was measured using a universal testing machine. Data analysis was performed using one way-ANOVA, independent T- test and paired t-test at 0.05 using IBM SPSS version 26.0.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>One-way ANOVA revealed a significant effect of printing orientation and layer thickness on the marginal fit and fracture strength of 3D printed crowns (p &lt; 0.001). One-way ANOVA showed that group C (60.76 [\u00b1 6.96]\u03bcm) showed significantly lower mean [\u00b1 SD] absolute marginal discrepancy (AMD) in \u00b5m than group A (72.26 [\u00b1 6.07] \u03bcm) and there was no statistically significant difference between group B and group C. One-way ANOVA revealed that there was a statistically significant difference in the mean value of fracture resistance between group B and each of two other groups: group A and group C. The highest mean value [\u00b1 SD] was reported with the samples of group A (977.97 [\u00b110.69]), while the lowest mean value was reported with the samples of group B (785.10 [\u00b1 20.43]) (p &lt; 0.001).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Printing orientation and layer thickness influenced marginal fit and fracture resistance of 3D printed provisional crowns.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-025-07330-2","type":"journal-article","created":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T03:23:29Z","timestamp":1765337009000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Evaluation of fit and fracture strength of three-dimensional provisional crowns printed with different orientations and different layer thicknesses: an in-vitro study"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2988-720X","authenticated-orcid":false,"given":"Gehad Mohamed Ali","family":"Ibrahim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tarek Abdelhamid","family":"Abdelhamid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mosaad Ali","family":"Elgabrouny","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amr Abdelaziz Shebl","family":"Kassem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,10]]},"reference":[{"key":"7330_CR1","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.sjdr.2014.03.002","volume":"6","author":"V Rakhshan","year":"2015","unstructured":"Rakhshan V. Marginal integrity of provisional resin restoration materials: a review of the literature. Saudi J Dent Res. 2015;6:33\u201340. https:\/\/doi.org\/10.1016\/j.sjdr.2014.03.002.","journal-title":"Saudi J Dent Res"},{"key":"7330_CR2","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/S0022-3913(03)00259-2","volume":"90","author":"DR Burns","year":"2003","unstructured":"Burns DR, Beck DA, Nelson SK. A review of selected dental literature on contemporary provisional fixed prosthodontic treatment. J Prosthet Dent. 2003;90:74\u201397. https:\/\/doi.org\/10.1016\/S0022-3913(03)00259-2.","journal-title":"J Prosthet Dent"},{"key":"7330_CR3","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1055\/s-0040-1703578","volume":"2","author":"K Prasad","year":"2012","unstructured":"Prasad K, Shetty M, Alva H, Prasad A. Provisional restorations in prosthodontic rehabilitation concepts, materials and techniques. NUJHS. 2012;2:72\u20137. https:\/\/doi.org\/10.1055\/s-0040-1703578.","journal-title":"NUJHS"},{"key":"7330_CR4","first-page":"167","volume":"50","author":"S Davis","year":"2004","unstructured":"Davis S. O\u2019Connell B.The provisional crown. J Ir Dent Assoc. 2004;50:4:167\u201372. PMID:15617435.","journal-title":"J Ir Dent Assoc"},{"key":"7330_CR5","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.cden.2011.02.011","volume":"55","author":"G Davidowitz","year":"2011","unstructured":"Davidowitz G, Kotick PG. The use of CAD\/CAM in dentistry. Dent Clin North Am. 2011;55:59\u201370. https:\/\/doi.org\/10.1016\/j.cden.2011.02.011.","journal-title":"Dent Clin North Am"},{"issue":"5","key":"7330_CR6","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1016\/j.jmbbm.2020.103975","volume":"111","author":"G Wemken","year":"2020","unstructured":"Wemken G, Spies BC, Pieralli S, Adali U, Beuer F, Wesemann C. Do hydrothermal aging and microwave sterilization affect the trueness of milled, additive manufactured and injection molded denture bases? J Mech Behav Biomed Mater. 2020;111(5):530\u201357. https:\/\/doi.org\/10.1016\/j.jmbbm.2020.103975.","journal-title":"J Mech Behav Biomed Mater"},{"key":"7330_CR7","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1155\/2022\/8353137","volume":"2","author":"AA Alshamrani","year":"2022","unstructured":"Alshamrani AA, Raju R, Ellakwa A. Effect of printing layer thickness and postprinting conditions on the flexural strength and hardness of a 3D-printed resin. Biomed Res Int. 2022;2:11\u201321. https:\/\/doi.org\/10.1155\/2022\/8353137.","journal-title":"Biomed Res Int"},{"key":"7330_CR8","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1021\/ac403397r","volume":"86","author":"BC Gross","year":"2014","unstructured":"Gross BC, Erkal JL, Lockwood SY, Chen C, Spence DM. Evaluation of 3D printing and its potential impact on biotechnology and the chemical sciences. Anal Chem. 2014;86:40\u201353. https:\/\/doi.org\/10.1021\/ac403397r.","journal-title":"Anal Chem"},{"key":"7330_CR9","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1007\/s00170-005-2523-2","volume":"29","author":"Q Liu","year":"2006","unstructured":"Liu Q, Leu MC, Schmitt SM. Rapid prototyping in dentistry: technology and application. Int J Adv Manuf Technol. 2006;29:17\u201335. https:\/\/doi.org\/10.1007\/s00170-005-2523-2.","journal-title":"Int J Adv Manuf Technol"},{"key":"7330_CR10","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1002\/adma.201706344","volume":"30","author":"M Layani","year":"2018","unstructured":"Layani M, Wang X, Magdassi S. Novel materials for 3D printing by photopolymerization. Adv Mater. 2018;30:17\u201344. https:\/\/doi.org\/10.1002\/adma.201706344.","journal-title":"Adv Mater"},{"key":"7330_CR11","doi-asserted-by":"publisher","first-page":"74","DOI":"10.11607\/ijp.5079","volume":"30","author":"N Alharbi","year":"2017","unstructured":"Alharbi N, Wismeijer D, Osman RB. Additive manufacturing techniques in prosthodontics: where do we currently stand? A critical review. Int J Prosthodont. 2017;30:74\u201384. https:\/\/doi.org\/10.11607\/ijp.5079.","journal-title":"Int J Prosthodont"},{"key":"7330_CR12","doi-asserted-by":"publisher","first-page":"104","DOI":"10.3390\/dj9090104","volume":"9","author":"L Nasiry Khanlar","year":"2021","unstructured":"Nasiry Khanlar L, Rios A, Tahmaseb A, Zandinejad A. Additive manufacturing of zirconia ceramic and its application in clinical dentistry: a review. Dent J. 2021;9:104\u201315. https:\/\/doi.org\/10.3390\/dj9090104.","journal-title":"Dent J"},{"key":"7330_CR13","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.dental.2011.10.014","volume":"28","author":"R Van Noort","year":"2012","unstructured":"Van Noort R. The future of dental devices is digital. Dent Mater. 2012;28:3\u201312. https:\/\/doi.org\/10.1016\/j.dental.2011.10.014.","journal-title":"Dent Mater"},{"key":"7330_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.11606\/issn.2357-8041.clrd.2019.188502","volume":"33","author":"LPG Costa","year":"2021","unstructured":"Costa LPG, Zamalloa SID, Alves FAM, Spigolon R, Mano LY, Costa C, et al. 3D printers in dentistry: a review of additive manufacturing techniques and materials. CLRD. 2021;33:1\u201310. https:\/\/doi.org\/10.11606\/issn.2357-8041.clrd.2019.188502.","journal-title":"CLRD"},{"key":"7330_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2021\/9950131","volume":"17","author":"Y Tian","year":"2021","unstructured":"Tian Y, Chen C. A review of 3D printing in dentistry: technologies, affecting factors, and applications. Scanning. 2021;17:1\u201319. https:\/\/doi.org\/10.1155\/2021\/9950131.","journal-title":"Scanning"},{"key":"7330_CR16","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1016\/j.prosdent.2019.05.034","volume":"124","author":"JS Shim","year":"2020","unstructured":"Shim JS, Kim JE, Jeong SH, Choi YJ, Ryu JJ. Printing accuracy, mechanical properties, surface characteristics, and microbial adhesion of 3D-printed resins with various printing orientations. J Prosthet Dent. 2020;124:468\u201375. https:\/\/doi.org\/10.1016\/j.prosdent.2019.05.034.","journal-title":"J Prosthet Dent"},{"issue":"2","key":"7330_CR17","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1002\/jbm.b.30897","volume":"84","author":"FC Calheiros","year":"2008","unstructured":"Calheiros FC, Daronch M, Rueggeberg FA, Braga RR. Degree of conversion and mechanical properties of a bisgma:tegdma composite as a function of the applied radiant exposure. J Biomed Mater Res. 2008;84(2):503\u20139. https:\/\/doi.org\/10.1002\/jbm.b.30897.","journal-title":"J Biomed Mater Res"},{"key":"7330_CR18","doi-asserted-by":"publisher","first-page":"983","DOI":"10.3390\/healthcare9080983","volume":"9","author":"K Son","year":"2021","unstructured":"Son K, Lee JH, Lee KB. Comparison of intaglio surface trueness of interim dental crowns fabricated with SLA 3D printing, DLP 3D printing, and milling technologies. Healthcare. 2021;9:983. https:\/\/doi.org\/10.3390\/healthcare9080983.","journal-title":"Healthcare"},{"key":"7330_CR19","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.jmbbm.2017.07.019","volume":"75","author":"F Huettig","year":"2017","unstructured":"Huettig F, Kustermann A, Kuscu E, Geis-Gerstorfer J, Spintzyk S. Polishability and wear resistance of splint material for oral appliances produced with conventional, subtractive, and additive manufacturing. J Mech Behav Biomed Mater. 2017;75:175\u20139. https:\/\/doi.org\/10.1016\/j.jmbbm.2017.07.019.","journal-title":"J Mech Behav Biomed Mater"},{"key":"7330_CR20","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1111\/jopr.12683","volume":"27","author":"A Azarbal","year":"2018","unstructured":"Azarbal A, Azarbal M, Engelmeier RL, Kunkel TC. Marginal fit comparison of CAD\/CAM crowns milled from two different materials. J Prosthodont. 2018;27:21\u20138. https:\/\/doi.org\/10.1111\/jopr.12683.","journal-title":"J Prosthodont"},{"key":"7330_CR21","doi-asserted-by":"publisher","first-page":"2175","DOI":"10.3758\/bf03193146","volume":"39","author":"F Faul","year":"2007","unstructured":"Faul F, Erdfelder E, Lang AG, Buchner A. G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39:2175\u201391. https:\/\/doi.org\/10.3758\/bf03193146.","journal-title":"Behav Res Methods"},{"key":"7330_CR22","doi-asserted-by":"publisher","first-page":"75","DOI":"10.21608\/edj.2018.78050","volume":"64","author":"T Abdel Hamid","year":"2018","unstructured":"Abdel Hamid T, Awad DS, Al-gabrouny MA, Atta O. Vertical marginal gap and internal fit of two types of fully anatomic zirconia crowns constructed by different CAD\/CAM systems. EDJ. 2018;64:75\u201383. https:\/\/doi.org\/10.21608\/edj.2018.78050.","journal-title":"EDJ"},{"key":"7330_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/ma14020259","volume":"14","author":"J Nold","year":"2021","unstructured":"Nold J, Wesemann C, Rieg L, Binder L, Witkowski S, Spies BC, Kohal RJ. Does printing orientation matter? In-vitro fracture strength of temporary fixed dental prostheses after a 1-year simulation in the artificial mouth. J Mater. 2021;14:1\u201312. https:\/\/doi.org\/10.3390\/ma14020259.","journal-title":"J Mater"},{"key":"7330_CR24","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.prosdent.2021.11.031","volume":"14","author":"MS Yang","year":"2022","unstructured":"Yang MS, Kim SK, Heo SJ, Koak JY, Park JM. Investigation of the marginal fit of a 3D-printed three-unit resin prosthesis with different build orientations and layer thicknesses. J Adv Prosthodont. 2022;14:250\u201361. https:\/\/doi.org\/10.1016\/j.prosdent.2021.11.031.","journal-title":"J Adv Prosthodont"},{"issue":"1","key":"7330_CR25","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/s0022-3913(00)70087-4","volume":"83","author":"M Groten","year":"2000","unstructured":"Groten M, Axmann D, Pr\u00f6bster L, Weber H. Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. J Prosthet Dent. 2000;83(1):40\u20139. https:\/\/doi.org\/10.1016\/s0022-3913(00)70087-4.","journal-title":"J Prosthet Dent"},{"issue":"1","key":"7330_CR26","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1111\/jopr.13646","volume":"33","author":"YE Ozden","year":"2024","unstructured":"Ozden YE, Ozkurt-Kayahan Z, Kazazoglu E. Effect of intraoral scanning distance on the marginal discrepancy of milled interim crowns. J Prosthodont. 2024;33(1):41\u20135. https:\/\/doi.org\/10.1111\/jopr.13646.","journal-title":"J Prosthodont"},{"key":"7330_CR27","doi-asserted-by":"publisher","first-page":"300","DOI":"10.3390\/ma12162533","volume":"12","author":"GS Park","year":"2019","unstructured":"Park GS, Kim SK, Heo SJ, Koak JY, Seo DG. Effects of printing parameters on the fit of implant-supported 3D printing resin prosthetics. J Mater. 2019;12:300\u201330. https:\/\/doi.org\/10.3390\/ma12162533.","journal-title":"J Mater"},{"key":"7330_CR28","doi-asserted-by":"publisher","first-page":"182","DOI":"10.11607\/ijp.5117","volume":"30","author":"R Osman","year":"2017","unstructured":"Osman R, Alharbi N, Wismeijer D. Build angle: does it influence the accuracy of 3D-printed dental restorations using digital light-processing technology? Int J Prosthodont. 2017;30:182\u20138. https:\/\/doi.org\/10.11607\/ijp.5117.","journal-title":"Int J Prosthodont"},{"key":"7330_CR29","doi-asserted-by":"publisher","first-page":"225","DOI":"10.4047\/jap.2020.12.4.225","volume":"12","author":"JE Ryu","year":"2020","unstructured":"Ryu JE, Kim YL, Kong HJ, Chang HS, Jung JH. Marginal and internal fit of 3D printed provisional crowns according to build directions. J Adv Prosthodont. 2020;12:225\u201332. https:\/\/doi.org\/10.4047\/jap.2020.12.4.225.","journal-title":"J Adv Prosthodont"},{"issue":"1","key":"7330_CR30","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/j.prosdent.2023.03.020","volume":"133","author":"M Revilla-Le\u00f3n","year":"2025","unstructured":"Revilla-Le\u00f3n M, Supaphakorn A, Barmak AB, Rutkunas V, Kois JC. Influence of print orientation on the intaglio surface accuracy (trueness and precision) of tilting stereolithography definitive resin-ceramic crowns. J Prosthet Dent. 2025;133(1):246\u201351. https:\/\/doi.org\/10.1016\/j.prosdent.2023.03.020.","journal-title":"J Prosthet Dent"},{"key":"7330_CR31","doi-asserted-by":"publisher","first-page":"503","DOI":"10.11607\/ijp.4835","volume":"29","author":"N Alharbi","year":"2016","unstructured":"Alharbi N, Osman R, Wismeijer D. Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology. Int J Prosthodont. 2016;29:503\u201310. https:\/\/doi.org\/10.11607\/ijp.4835.","journal-title":"Int J Prosthodont"},{"key":"7330_CR32","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.jdent.2022.104155","volume":"124","author":"AA Diken Turksayar","year":"2022","unstructured":"Diken Turksayar AA, Donmez MB, Olcay EO, Demirel M, Demir E. Effect of printing orientation on the fracture strength of additively manufactured 3-unit interim fixed dental prostheses after aging. J Dent. 2022;124:74\u201380. https:\/\/doi.org\/10.1016\/j.jdent.2022.104155.","journal-title":"J Dent"},{"key":"7330_CR33","doi-asserted-by":"publisher","first-page":"5","DOI":"10.3390\/app11199246","volume":"11","author":"G \u00c7akmak","year":"2021","unstructured":"\u00c7akmak G, Cuellar AR, Donmez MB, Schimmel M, Abou-Ayash S, Lu WE, Yilmaz B. Effect of printing layer thickness on the trueness and margin quality of 3d-printed interim dental crowns. Appl Sci. 2021;11:5\u201320. https:\/\/doi.org\/10.3390\/app11199246.","journal-title":"Appl Sci"},{"key":"7330_CR34","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1007\/s00056-019-00180-y","volume":"80","author":"Zchen Zhang","year":"2019","unstructured":"Zhang Zchen, Li Plun, Chu Fting, Shen G. Influence of the three-dimensional printing technique and printing layer thickness on model accuracy. J Orofac Orthop. 2019;80:194\u2013204. https:\/\/doi.org\/10.1007\/s00056-019-00180-y.","journal-title":"J Orofac Orthop"},{"key":"7330_CR35","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1002\/cre2.758","volume":"20","author":"M Hasanzade","year":"2023","unstructured":"Hasanzade M, Yaghoobi N, Nematollahi P, Ghazanfari R. Comparison of the marginal and internal fit of PMMA interim crowns printed with different layer thicknesses in 3D-printing technique. Clin Exp Dent Res. 2023;20:202\u201330. https:\/\/doi.org\/10.1002\/cre2.758.","journal-title":"Clin Exp Dent Res"},{"key":"7330_CR36","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/ma14030509","volume":"14","author":"A Sabbah","year":"2021","unstructured":"Sabbah A, Romanos G, Delgado-Ruiz R. Impact of layer thickness and storage time on the properties of 3D-printed dental dies. J Mater. 2021;14:1\u201310. https:\/\/doi.org\/10.3390\/ma14030509.","journal-title":"J Mater"},{"issue":"4","key":"7330_CR37","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1016\/j.sdentj.2024.01.004","volume":"36","author":"A Aljehani","year":"2024","unstructured":"Aljehani A, Nabalawi A, Hefni A, Alsefri Z, Fakhry O, Al Zaibak W, et al. Effect of build orientation on the fracture resistance and marginal quality of 3D-printed anatomic provisional crowns: an in-vitro study. Saudi Dent J. 2024;36(4):584\u201390. https:\/\/doi.org\/10.1016\/j.sdentj.2024.01.004.","journal-title":"Saudi Dent J"},{"issue":"11","key":"7330_CR38","doi-asserted-by":"publisher","DOI":"10.3390\/molecules30112337","volume":"30","author":"YE \u00d6zden","year":"2025","unstructured":"\u00d6zden YE, Do\u011fu Kaya B, Y\u0131lmaz Atal\u0131 P, Ozer F, Ozkurt Kayahan Z. Effect of print orientation and thermal aging on the flexural strength of zirconia-reinforced three-dimensional-printed restorative resin materials. Molecules. 2025;30(11):2337. https:\/\/doi.org\/10.3390\/molecules30112337.","journal-title":"Molecules"},{"issue":"3","key":"7330_CR39","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1016\/j.prosdent.2014.01.012","volume":"112","author":"J Yao","year":"2014","unstructured":"Yao J, Li J, Wang Y, Huang H. Comparison of the flexural strength and marginal accuracy of traditional and CAD\/CAM interim materials before and after thermal cycling. J Prosthet Dent. 2014;112(3):649\u201357. https:\/\/doi.org\/10.1016\/j.prosdent.2014.01.012.","journal-title":"J Prosthet Dent"},{"issue":"2","key":"7330_CR40","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1111\/j.1365-2842.2008.01908.x","volume":"36","author":"F Beuer","year":"2009","unstructured":"Beuer F, Neumeier P, Naumann M. Marginal fit of 14-unit zirconia fixed dental prosthesis retainers. J Oral Rehabil. 2009;36(2):142\u20139. https:\/\/doi.org\/10.1111\/j.1365-2842.2008.01908.x.","journal-title":"J Oral Rehabil"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-07330-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-07330-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-07330-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T15:13:14Z","timestamp":1781622794000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-025-07330-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,10]]},"references-count":40,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["7330"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-07330-2","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,10]]},"assertion":[{"value":"4 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was achieved at the Department of Fixed prosthodontics, Faculty of Dentistry, Suez Canal University, and approved by the Faculty of Dentistry Research Ethics Committee (REC) (approval number 577\/2022). All methods were performed following the relevant guidelines and regulations. This in-vitro study did not involve human participants or human data. Therefore, ethical approval and informed consent were not required. The study was conducted in accordance with the principles of the Declaration of Helsinki, as applicable to experimental research.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"92"}}