{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,11]],"date-time":"2026-10-11T14:58:47Z","timestamp":1791730727048,"version":"4.3.4"},"reference-count":64,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,26]],"date-time":"2026-01-26T00:00:00Z","timestamp":1769385600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T00:00:00Z","timestamp":1770249600000},"content-version":"vor","delay-in-days":10,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009367","name":"Mansoura University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100009367","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>This study aimed to evaluate the biomechanical behavior and stress distribution of tooth\u2013implant-supported telescopic prostheses using different combinations of zirconia, polyetherketoneketone (PEKK), and cobalt\u2013chromium (Co-Cr) materials for primary and secondary crowns by means of three-dimensional finite element analysis (3D FEA).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>A three-dimensional finite element model representing a mandibular arch restored with a telescopic overdenture supported by two canines and two implants in the molar region was constructed. Nine prosthetic configurations were analyzed based on different primary and secondary crown material combinations (zirconia, PEKK, and Co-Cr). All materials were assumed to be homogeneous, isotropic, and linearly elastic. Static axial occlusal loads simulating centric occlusion were applied. Von Mises stress distribution was evaluated in prosthetic components, implants, natural teeth, and surrounding bone.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Material selection significantly influenced stress distribution within the telescopic system and supporting structures. PEKK used as a secondary crown reduced stress concentrations within the prosthetic crowns but resulted in increased stress transfer to the supporting bone, teeth, and implants compared with zirconia and Co-Cr. When PEKK was used as a primary crown, stress levels within prosthetic components were reduced, while stress transmission to supporting structures was not substantially altered. Zirconia and Co-Cr demonstrated comparable biomechanical behavior across all configurations. In all models, secondary crowns exhibited higher stress values than primary crowns, and implants were subjected to greater loads than natural teeth.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Within the limitations of this 3D finite element study, material combinations in tooth\u2013implant-supported telescopic prostheses significantly affect biomechanical stress distribution. PEKK exhibits a material-dependent stress-modulating behavior that should be carefully considered during prosthetic design to balance prosthetic protection and load transfer to supporting structures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-025-07607-6","type":"journal-article","created":{"date-parts":[[2026,1,26]],"date-time":"2026-01-26T09:23:56Z","timestamp":1769419436000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Three-dimensional finite element analysis of tooth and implant-supported telescopic prosthesis using zirconia, PEKK, and cobalt chromium crowns"],"prefix":"10.1186","volume":"26","author":[{"given":"Sarah Zaman Sahib","family":"Awad","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2062-7623","authenticated-orcid":false,"given":"Khloud Ezzat","family":"Mourad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0954-6398","authenticated-orcid":false,"given":"Ahmed","family":"Sameh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7043-489X","authenticated-orcid":false,"given":"Ahmed Heji","family":"Albaqawi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aisha Zakaria Hashem","family":"Mostafa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,26]]},"reference":[{"key":"7607_CR1","doi-asserted-by":"crossref","unstructured":"de Freitas RF, de Carvalho Dias K, da, Porto Carreiro F, Barbosa A, Ferreira GA. MA. Mandibular implantsupported removable partial denture with distal extension: A systematic review. J Oral Rehabil. 2012;39(10):791\u201398.","DOI":"10.1111\/j.1365-2842.2012.02326.x"},{"issue":"1","key":"7607_CR2","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1186\/s40729-021-00394-z","volume":"7","author":"AY Putra Wigianto","year":"2021","unstructured":"Putra Wigianto AY, Goto T, Iwawaki Y, Ishida Y, Watanabe M, Ichikawa T. Treatment outcomes of implant-assisted removable partial denture with distal extension based on the Kennedy classification and attachment type: a systematic review. Int J Implant Dent. 2021;7(1):111.","journal-title":"Int J Implant Dent"},{"issue":"1","key":"7607_CR3","doi-asserted-by":"publisher","first-page":"20","DOI":"10.2186\/jpr.JPR_D_22_00252","volume":"68","author":"S Kuroshima","year":"2024","unstructured":"Kuroshima S, Ohta Y, Uto Y, Al-Omari FA, Sasaki M, Sawase T. Implant-assisted removable partial dentures: part I. a scoping review of clinical applications. J Prosthodont Res. 2024;68(1):20\u201339.","journal-title":"J Prosthodont Res"},{"issue":"3","key":"7607_CR4","first-page":"217","volume":"25","author":"V Szentpetery","year":"2012","unstructured":"Szentpetery V, Lautenschlager C, Setz JM. Frictional telescopic crowns in severely reduced dentitions: a 5-year clinical outcome study. Int J Prosthodont. 2012;25(3):217.","journal-title":"Int J Prosthodont"},{"issue":"1","key":"7607_CR5","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1111\/j.1532-849X.2012.00905.x","volume":"22","author":"R Verma","year":"2013","unstructured":"Verma R, Joda T, Bragger U, Wittneben JG. A systematic review of the clinical performance of tooth-retained and implant-retained double crown prostheses with a follow up of >\/= 3 years. J Prosthodont. 2013;22(1):2\u201312.","journal-title":"J Prosthodont"},{"key":"7607_CR6","doi-asserted-by":"crossref","unstructured":"Kern JS, Hanisch O, Hamm\u00e4cher C, Yildirim M, Wolfart S. Telescopic crowns on implants and teeth: evaluation of A clinical study after 8 to 12 years. Int J Oral Maxillofac Implants. 2019;34(4):977\u201386.","DOI":"10.11607\/jomi.7204"},{"issue":"2","key":"7607_CR7","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1111\/cid.12739","volume":"21","author":"S Brandt","year":"2019","unstructured":"Brandt S, Winter A, Weigl P, Brandt J, Romanos G, Lauer HC. Conical zirconia telescoping into electroformed gold: A retrospective study of prostheses supported by teeth and\/or implants. Clin Implant Dent Relat Res. 2019;21(2):317\u201323.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"2","key":"7607_CR8","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1111\/jopr.13512","volume":"32","author":"K Igarashi","year":"2023","unstructured":"Igarashi K, Katagiri H, Abou-Ayash S, Schimmel M, Afrashtehfar KI. Double-Crown prosthesis retention using polyetherketoneketone (PEKK): an in vitro study. J Prosthodont. 2023;32(2):154\u201361.","journal-title":"J Prosthodont"},{"key":"7607_CR9","doi-asserted-by":"publisher","first-page":"1173","DOI":"10.1007\/s00784-013-1093-1","volume":"18","author":"J Groesser","year":"2014","unstructured":"Groesser J, Sachs C, Hei\u00df P, et al. Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia\u2013an in vitro study. Clin Oral Investig. 2014;18:1173\u201311794.","journal-title":"Clin Oral Investig"},{"issue":"1","key":"7607_CR10","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.prosdent.2004.10.013","volume":"93","author":"MI MacEntee","year":"2005","unstructured":"MacEntee MI, Walton JN, Glick N. A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: Three-year results. J Prosthet Dent. 2005;93(1):28\u201337.","journal-title":"J Prosthet Dent"},{"issue":"1","key":"7607_CR11","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.prosdent.2025.02.033","volume":"134","author":"X Tao","year":"2025","unstructured":"Tao X, Xu Z, Lin Z, Wu Q. A completely digital workflow for a maxillary tooth-supported complete overdenture and mandibular telescopic denture to manage the treatment of a patient with hypohidrotic ectodermal dysplasia. J Prosthet Dent. 2025;134(1):17\u201323.","journal-title":"J Prosthet Dent"},{"issue":"3","key":"7607_CR12","first-page":"214","volume":"30","author":"AMA Mohamed","year":"2022","unstructured":"Mohamed AMA, Nawar NH. Strain gauge analysis of the stresses induced by different secondary coping materials in tooth supported telescopic overdentures. Eur J Prosthodont Restor Dent. 2022;30(3):214\u201322.","journal-title":"Eur J Prosthodont Restor Dent"},{"issue":"6","key":"7607_CR13","doi-asserted-by":"publisher","first-page":"1987","DOI":"10.3390\/ijerph17061987","volume":"17","author":"T Joda","year":"2020","unstructured":"Joda T, Bornstein MM, Jung RE, Ferrari M, Waltimo T, Zitzmann NU. Recent trends and future direction of dental research in the digital era. Int J Environ Res Public Health. 2020;17(6):1987.","journal-title":"Int J Environ Res Public Health"},{"issue":"10","key":"7607_CR14","first-page":"e1045","volume":"10","author":"I Turkyilmaz","year":"2018","unstructured":"Turkyilmaz I, Hariri N-H. Four-year outcomes of full-arch fixed dental prostheses using CAD\/CAM frameworks: A retrospective review of 15 cases. J Clin Experimental Dentistry. 2018;10(10):e1045.","journal-title":"J Clin Experimental Dentistry"},{"key":"7607_CR15","doi-asserted-by":"crossref","unstructured":"Alharbi N, Wismeijer D, Osman RB. Additive manufacturing techniques in prosthodontics: where do we currently stand? A critical review. Int J Prosthodont. 2017;30(5). https:\/\/pubmed.ncbi.nlm.nih.gov\/28750105\/","DOI":"10.11607\/ijp.5079"},{"issue":"1","key":"7607_CR16","doi-asserted-by":"publisher","first-page":"3194433","DOI":"10.1155\/2021\/3194433","volume":"2021","author":"N Ahmed","year":"2021","unstructured":"Ahmed N, Abbasi MS, Haider S, Ahmed N, Habib SR, Altamash S, et al. Fit accuracy of removable partial denture frameworks fabricated with CAD\/CAM, rapid prototyping, and conventional techniques: A systematic review. Biomed Res Int. 2021;2021(1):3194433.","journal-title":"Biomed Res Int"},{"key":"7607_CR17","doi-asserted-by":"publisher","first-page":"2331","DOI":"10.1007\/s00784-018-2657-x","volume":"23","author":"O Schubert","year":"2019","unstructured":"Schubert O, Reitmaier J, Schweiger J, Erdelt K, G\u00fcth J-F. Retentive force of E secondary crowns on zirconia primary crowns over time. Clin Oral Invest. 2019;23:2331\u20138.","journal-title":"Clin Oral Invest"},{"issue":"2","key":"7607_CR18","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1111\/jopr.13575","volume":"32","author":"W Kim","year":"2023","unstructured":"Kim W, Li XC, Bidra AS. Clinical outcomes of implant-supported monolithic zirconia crowns and fixed partial dentures: a systematic review. J Prosthodont. 2023;32(2):102\u20137.","journal-title":"J Prosthodont"},{"key":"7607_CR19","first-page":"1","volume":"9","author":"S Merk","year":"2016","unstructured":"Merk S, Wange C, Stock V, Echberger M, Schmildin P, Roos M, Stawarczyk B. Suitability of secondary PEEK telescopic crown on zirconia primary crown: the influence of fabrication method and Tyaper. J Mater. 2016;9:1\u20139.","journal-title":"J Mater"},{"issue":"11","key":"7607_CR20","doi-asserted-by":"publisher","first-page":"6297","DOI":"10.1007\/s00784-021-03928-2","volume":"25","author":"M Schimmel","year":"2021","unstructured":"Schimmel M, Walther M, Al-Haj Husain N, Igarashi K, Wittneben J, Abou-Ayash S. Retention forces between primary and secondary CAD\/CAM manufactured telescopic crowns: an in vitro comparison of common material combinations. Clin Oral Investig. 2021;25(11):6297\u2013307.","journal-title":"Clin Oral Investig"},{"key":"7607_CR21","doi-asserted-by":"publisher","first-page":"102","DOI":"10.3109\/00016357.2011.654248","volume":"71","author":"B Stawarczyk","year":"2013","unstructured":"Stawarczyk B, Ozcan M, Schmutz F, Trottmann A, Roos M, Hammerle CH. Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists. Acta Odontol Scand. 2013;71:102\u201312.","journal-title":"Acta Odontol Scand"},{"key":"7607_CR22","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1111\/j.1532-849X.2011.00784.x","volume":"20","author":"F Rojas-Vizcaya","year":"2011","unstructured":"Rojas-Vizcaya F. Full zirconia fixed detachable implantretained restorations manufactured from monolithic zirconia: clinical report after two years in service. J Prosthodont. 2011;20:570\u20136.","journal-title":"J Prosthodont"},{"key":"7607_CR23","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1111\/jopr.13398","volume":"31","author":"FI Gentz","year":"2022","unstructured":"Gentz FI, Brooks DI, Liacouras PC, et al. Retentive forces ofremovable partial denture clasp assemblies made frompolyaryletherketone and cobalt-chromium: a comparative study. J Prosthodont. 2022;31:299\u2013304.","journal-title":"J Prosthodont"},{"key":"7607_CR24","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.jare.2020.09.004","volume":"28","author":"H Alqurashi","year":"2020","unstructured":"Alqurashi H, Khurshid Z, Syed AUY, Rashid Habib S, Rokaya D, Zafar MS. Polyetherketoneketone (PEKK): an emerging biomaterial for oral implants and dental prostheses. J Adv Res. 2020;28:87\u201395.","journal-title":"J Adv Res"},{"issue":"9","key":"7607_CR25","doi-asserted-by":"publisher","first-page":"2170","DOI":"10.3390\/polym15092170","volume":"15","author":"SM Zol","year":"2023","unstructured":"Zol SM, Alauddin MS, Said Z, Mohd Ghazali MI, Hao-Ern L, Mohd Farid DA, Zahari NAH, Al-Khadim AHA, Abdul Aziz AH. Description of Poly(aryl-ether-ketone) materials (PAEKs), polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) for application as a dental material. Mater Sci Rev Polym (Basel). 2023;15(9):2170.","journal-title":"Mater Sci Rev Polym (Basel)"},{"key":"7607_CR26","first-page":"1","volume-title":"Finite element methods and their applications","author":"V Bandela","year":"2020","unstructured":"Bandela V, Kanaparthi S. Finite element analysis and its appli cations in dentistry. In: Baccouch M, editor. Finite element methods and their applications. London, UK: IntechOpen; 2020. pp. 1\u201324."},{"issue":"02","key":"7607_CR27","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1055\/s-0042-1749363","volume":"17","author":"NM Al-Kordy","year":"2023","unstructured":"Al-Kordy NM, Al-Saadi MH. Finite element study of stress distribution with tooth-supported mandibular overdenture retained by ball attachments or resilient telescopic crowns. Eur J Dentistry. 2023;17(02):539\u201347.","journal-title":"Eur J Dentistry"},{"issue":"12","key":"7607_CR28","first-page":"2851","volume":"7","author":"P Amornvit","year":"2013","unstructured":"Amornvit P, Rokaya D, Keawcharoen K, Thongpulsawasdi N. Stress distribution in implant retained finger prosthesis: a finite element study. J Clin Diagn Research: JCDR. 2013;7(12):2851.","journal-title":"J Clin Diagn Research: JCDR"},{"issue":"03","key":"7607_CR29","first-page":"342","volume":"2","author":"S Liliana","year":"2012","unstructured":"Liliana S, Florin T, Sorin P. Finite element study on Corono radicular restored teeth. Inter J Model Optim. 2012;2(03):342\u20133452.","journal-title":"Inter J Model Optim"},{"issue":"7","key":"7607_CR30","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1016\/S0003-9969(00)00031-5","volume":"45","author":"A Asundi","year":"2000","unstructured":"Asundi A, Kishen A. A strain gauge and photoelastic analysis of in vivo strain and in vitro stress distribution in human dental supporting structures. Arch Oral Biol. 2000;45(7):543\u201350.","journal-title":"Arch Oral Biol"},{"issue":"03","key":"7607_CR31","doi-asserted-by":"publisher","first-page":"425","DOI":"10.4103\/0970-9290.70813","volume":"21","author":"A Srirekha","year":"2010","unstructured":"Srirekha A, Bashetty K. Infinite to finite: an overview of finite element analysis. Indian J Dent Res. 2010;21(03):425\u201332.","journal-title":"Indian J Dent Res"},{"issue":"4","key":"7607_CR32","first-page":"189","volume":"2","author":"Y Wang","year":"2024","unstructured":"Wang Y, Chen L. Advancements in finite element analysis for prosthodontics. Prog Med Devices. 2024;2(4):189\u2013204.","journal-title":"Prog Med Devices"},{"issue":"21","key":"7607_CR33","doi-asserted-by":"publisher","first-page":"4814","DOI":"10.3390\/ma13214814","volume":"13","author":"CAI Fischer","year":"2020","unstructured":"Fischer CAI, Ghergic DL, Vranceanu DM, et al. Assessment of force retention between milled metallic and ceramic telescopic crowns with different taper angles used for oral rehabilitation. Mater (Basel). 2020;13(21):4814. https:\/\/doi.org\/10.3390\/ma13214814 . Published 2020 Oct 28.","journal-title":"Mater (Basel)"},{"issue":"2","key":"7607_CR34","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1111\/jopr.12482","volume":"27","author":"C Wagner","year":"2018","unstructured":"Wagner C, Stock V, Merk S, et al. Retention load of telescopic crowns with different taper angles between Cobalt-Chromium and polyetheretherketone made with three different manufacturing processes examined by Pull-Off test. J Prosthodont. 2018;27(2):162\u20138. https:\/\/doi.org\/10.1111\/jopr.12482.","journal-title":"J Prosthodont"},{"issue":"2","key":"7607_CR35","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1111\/jopr.13512","volume":"32","author":"K Igarashi","year":"2023","unstructured":"Igarashi K, Katagiri H, Abou-Ayash S, Schimmel M, Afrashtehfar KI. Double\u2010crown prosthesis retention using polyetherketoneketone (PEKK): an in vitro study. J Prosthodont. 2023;32(2):154\u201361.","journal-title":"J Prosthodont"},{"issue":"7","key":"7607_CR36","doi-asserted-by":"publisher","first-page":"3446","DOI":"10.3390\/app12073446","volume":"12","author":"JP Tribst","year":"2022","unstructured":"Tribst JP, Dal Piva AM, Syed AU, Alrabiah M, Al-Aali KA, Vohra F, Abduljabbar T. Comparative stress analysis of polyetherketoneketone (PEKK) telescopic crowns supported by different primary crown materials. Appl Sci. 2022;12(7):3446.","journal-title":"Appl Sci"},{"key":"7607_CR37","doi-asserted-by":"crossref","unstructured":"Idzior-Haufa M, Pilarska AA, H\u0119dzelek W, Boniecki P, Pilarski K, Dorocka-Bobkowska B. A Comparison of Biomechanical Properties of Implant-Retained Overdenture Based on Precision Attachment Type. Materials (Basel). 2021. Cited 2025.","DOI":"10.3390\/ma14102598"},{"key":"7607_CR38","doi-asserted-by":"crossref","unstructured":"Shahmiri R, Das R, Aarts JM, Bennani V. Finite element analysis of an implant-assisted removable partial denture during bilateral loading: occlusal rests position. J Prosthet Dent. 2014;112(5):1126\u201333. Cited 16 May 2025.","DOI":"10.1016\/j.prosdent.2014.04.023"},{"issue":"1","key":"7607_CR39","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1111\/j.1600-0501.2005.01162.x","volume":"17","author":"AN Natali","year":"2006","unstructured":"Natali AN, Pavan PG, Ruggero AL. Analysis of bone\u2013implant interaction phenomena by using a numerical approach. Clin Oral Implants Res. 2006;17(1):67\u201374. https:\/\/doi.org\/10.1111\/j.1600-0501.2005.01162.x.","journal-title":"Clin Oral Implants Res"},{"issue":"7","key":"7607_CR40","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1016\/j.dental.2013.04.010","volume":"29","author":"R Tiossi","year":"2013","unstructured":"Tiossi R, Faria ACL, Lin CL, Ribeiro RF, Greghi SLA, Rodrigues RCS. Validation of finite element models for strain analysis of implant-supported prostheses using digital image correlation. Dent Mater. 2013;29(7):788\u201396. https:\/\/doi.org\/10.1016\/j.dental.2013.04.010.","journal-title":"Dent Mater"},{"key":"7607_CR41","doi-asserted-by":"crossref","unstructured":"Baccouch Mahboub. Finite element methods and their applications. 2021. Cited 16 May 2025; Available from: https:\/\/books.google.com\/books\/about\/Finite_Element_Methods_and_Their_Applica.html?id=o7ZaEAAAQBAJ.","DOI":"10.5772\/intechopen.83274"},{"key":"7607_CR42","doi-asserted-by":"crossref","unstructured":"Stock V, Wagner C, Merk S, Roos M, Schmidlin PR, Eichberger M et al. Retention force of differently fabricated telescopic PEEK crowns with different tapers. Dent Mater J. 2016;35(4):594\u2013600. Cited 12 Jun 2025. Available from: https:\/\/europepmc.org\/article\/med\/27477224.","DOI":"10.4012\/dmj.2015-249"},{"issue":"1","key":"7607_CR43","doi-asserted-by":"publisher","first-page":"24","DOI":"10.4103\/jdi.jdi_6_19","volume":"9","author":"RM Emera","year":"2019","unstructured":"Emera RM, Altonbary GY, Elbashir SA. Comparison between all zirconia, all PEEK, and zirconia-PEEK telescopic attachments for two implants retained mandibular complete overdentures: in vitro stress analysis study. J Dent Implants. 2019;9(1):24\u20139.","journal-title":"J Dent Implants"},{"issue":"19","key":"7607_CR44","doi-asserted-by":"publisher","first-page":"4429","DOI":"10.3390\/jcm10194429","volume":"10","author":"A Kamel","year":"2021","unstructured":"Kamel A, Badr A, Fekry G, Tsoi J. Parameters affecting the retention force of CAD\/CAM telescopic crowns: A focused review of in vitro studies. J Clin Med. 2021;10(19):4429\u20134429.","journal-title":"J Clin Med"},{"issue":"1","key":"7607_CR45","doi-asserted-by":"publisher","first-page":"28398","DOI":"10.1038\/s41598-024-79306-1","volume":"14","author":"Y Chen","year":"2024","unstructured":"Chen Y, Liu W, Wu Z, Wang S, Li Y, Su B, Li S. Advantages and feasibility of prefabricated PEEK crowns for aesthetic restoration in primary teeth. Sci Rep. 2024;14(1):28398.","journal-title":"Sci Rep"},{"key":"7607_CR46","doi-asserted-by":"crossref","unstructured":"Mostafa D, Hussein O, Hussein MO. Biomechanical Performance of PEEK and Graphene-Modified PMMA as Telescopic Removable Partial Denture Materials: A Nonlinear 3D Finite Element Analysis. 2022.","DOI":"10.11607\/ijp.8177"},{"key":"7607_CR47","doi-asserted-by":"crossref","unstructured":"Papathanasiou I, Kamposiora P, Papavasiliou G, Ferrari M. The use of PEEK in digital prosthodontics: A narrative review. BMC Oral Health. 2020;20(1).","DOI":"10.1186\/s12903-020-01202-7"},{"key":"7607_CR48","doi-asserted-by":"publisher","unstructured":"Niem T, Youssef N, W\u00f6stmann B. Energy dissipation capacities of CAD-CAM restorative materials: A comparative evaluation of resilience and toughness. J Prosthet Dent;121(1):101\u20139. https:\/\/doi.org\/10.1016\/j.prosdent.2018.05.0.","DOI":"10.1016\/j.prosdent.2018.05.0"},{"key":"7607_CR49","doi-asserted-by":"publisher","first-page":"451","DOI":"10.11607\/ijp.4688","volume":"29","author":"K Han","year":"2016","unstructured":"Han K, Lee J, Shin SW, Han K, Lee J, Shin SW. Implant-and tooth-supported fixed prostheses using a high-performance polymer (Pekkton) framework. Int J Prosthodont. 2016;29:451\u20134.","journal-title":"Int J Prosthodont"},{"key":"7607_CR50","first-page":"6","volume":"32","author":"MM Aboelnagga","year":"2023","unstructured":"Aboelnagga MM. Comparative stress analysis of BioHPP and PEKK CAD\/CAM frameworks in mandibular All-on-Four fixeddetachable prosthesis on its supporting implants. ASDJ. 2023;32:6\u201317.","journal-title":"ASDJ"},{"issue":"3","key":"7607_CR51","doi-asserted-by":"publisher","first-page":"929","DOI":"10.1016\/j.jds.2020.11.005","volume":"16","author":"K Mizusawa","year":"2021","unstructured":"Mizusawa K, Shin C, Okada D, Ogura R, Komada W, Saleh O, Huang L, Miura H. The investigation of the stress distribution in abutment teeth for connected crowns. J Dent Sci. 2021;16(3):929\u201336.","journal-title":"J Dent Sci"},{"issue":"4","key":"7607_CR52","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1016\/j.dental.2021.01.003","volume":"37","author":"HH Chang","year":"2021","unstructured":"Chang HH, Yeh CL, Wang YL, Huang YC, Tsai SJ, Li YT, et al. Differences in the Biomechanical behaviors of natural teeth and dental implants. Dent Mater. 2021;37(4):682\u20139.","journal-title":"Dent Mater"},{"key":"7607_CR53","doi-asserted-by":"crossref","unstructured":"Sz\u00e1va DT, Sz\u00e1va A, Sz\u00e1va J, G\u00e1lfi B, Vlase S. Dental implant and natural tooth Micro-Movements during Mastication\u2014In vivo study with 3D VIC method. J Pers Med. 2022;12(10). https:\/\/pubmed.ncbi.nlm.nih.gov\/36294829\/.","DOI":"10.3390\/jpm12101690"},{"key":"7607_CR54","doi-asserted-by":"publisher","DOI":"10.1055\/s-0044-1800841","author":"K Thaungwilai","year":"2025","unstructured":"Thaungwilai K, Tantilertanant Y, Tomeboon P, Singhatanadgit W, Singhatanadgid P. Biomechanical evaluation of stress distribution in a natural tooth adjacent to a dental implant using finite element modeling. Eur J Gen Dent. 2025. https:\/\/doi.org\/10.1055\/s-0044-1800841.","journal-title":"Eur J Gen Dent"},{"issue":"3","key":"7607_CR55","doi-asserted-by":"publisher","first-page":"169","DOI":"10.4047\/jap.2019.11.3.169","volume":"11","author":"D Robinson","year":"2019","unstructured":"Robinson D, Aguilar L, Gatti A, Abduo J, Lee PVS, Ackland D. Load response of the natural tooth and dental implant: A comparative biomechanics study. J Adv Prosthodont. 2019;11(3):169\u201378.","journal-title":"J Adv Prosthodont"},{"key":"7607_CR56","doi-asserted-by":"crossref","unstructured":"Ulbrich NL, Hecke MB, Possobom AL, Bassanta AD. Comparative FEM analysis of the stresses transmitted by intramobile elements of the IMZ implant. Comput Methods Biomech Biomedical Eng \u2013 2. 2020;721\u20138. https:\/\/www.taylorfrancis.com\/chapters\/edit\/10.1201\/9781003078289-95\/comparative-fem-analysis-stresses-transmitted-intramobile-elements-imz-implant-ulbrich-hecke-possobom-bassanta","DOI":"10.1201\/9781003078289-95"},{"key":"7607_CR57","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1186\/s12903-024-04091-2","volume":"24","author":"CR Ibrahim","year":"2024","unstructured":"Ibrahim CR, Sameh A, Askar O. A finite element analysis study on different angle correction designs for inclined implants in All-On-Four protocol. BMC Oral Health. 2024;24:331. https:\/\/doi.org\/10.1186\/s12903-024-04091-2.","journal-title":"BMC Oral Health"},{"key":"7607_CR58","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.msec.2015.01.095","volume":"50","author":"F Lofaj","year":"2015","unstructured":"Lofaj F, Ku\u010dera J, N\u00e9meth D, Kvetkov\u00e1 L. Finite element analysis of stress distributions in mono- and bi-cortical dental implants. Mater Sci Eng C Mater Biol Appl. 2015;50:85\u201396. Epub 2015 Feb 2. PMID: 25746249.","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"key":"7607_CR59","doi-asserted-by":"publisher","first-page":"5680","DOI":"10.3390\/ma17235680","volume":"17","author":"M Ceddia","year":"2024","unstructured":"Ceddia M, Romasco T, De Bortoli N Jr., Mello BF, Piattelli A, Mijiritsky E, Di Pietro N, Trentadue B. Biomechanical finite element analysis of two types of Short-Angled implants across various bone classifications. Materials. 2024;17:5680. https:\/\/doi.org\/10.3390\/ma17235680.","journal-title":"Materials"},{"key":"7607_CR60","doi-asserted-by":"crossref","unstructured":"Pedroso JM, Enger M, Bandeira P, Magalh\u00e3es FD. Comparative study of friction and wear performance of PEK, PEEK and PEKK binders in tribological coatings. Polymers. 2022;14:4008. https:\/\/www.mdpi.com\/2073-4360\/14\/19\/4008","DOI":"10.3390\/polym14194008"},{"issue":"4","key":"7607_CR61","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/s10916-019-1230-8","volume":"43","author":"A Ruggiero","year":"2019","unstructured":"Ruggiero A, D\u2019Amato R, Sbordone L, Haro FB, Lanza A. Experimental comparison on dental biotribological pairs Zirconia\/Zirconia and Zirconia\/Natural tooth by using a reciprocating tribometer. J Med Syst. 2019;43(4):97.","journal-title":"J Med Syst"},{"issue":"23","key":"7607_CR62","doi-asserted-by":"publisher","first-page":"7293","DOI":"10.3390\/ma14237293","volume":"14","author":"LT Ciocan","year":"2021","unstructured":"Ciocan LT, Ghitman J, Vasilescu VG, Iovu H. Mechanical properties of Polymer-Based blanks for machined dental restorations. Materials. 2021;14(23):7293.","journal-title":"Materials"},{"issue":"1","key":"7607_CR63","first-page":"1","volume":"27","author":"X Chen","year":"2019","unstructured":"Chen X, Mao B, Zhu Z, Yu J, Lu Y, Zhang Q, et al. A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEK. Sci Rep. 2019;27(1):1\u201310.","journal-title":"Sci Rep"},{"issue":"1","key":"7607_CR64","doi-asserted-by":"publisher","first-page":"91","DOI":"10.11607\/ijp.6137","volume":"32","author":"A Elsayed","year":"2018","unstructured":"Elsayed A, Farrag G, Chaar M, Abdelnabi N, Kern M. Influence of different CAD\/CAM crown materials on the fracture of Custom-Made titanium and zirconia implant abutments after artificial aging. Int J Prosthodont. 2018;32(1):91\u20136.","journal-title":"Int J Prosthodont"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-07607-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-07607-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-07607-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T17:08:48Z","timestamp":1781629728000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-025-07607-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,26]]},"references-count":64,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["7607"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-07607-6","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-7437679\/v1","asserted-by":"object"}]},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,26]]},"assertion":[{"value":"22 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"253"}}