{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T18:37:41Z","timestamp":1794854261941,"version":"4.9.1"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T00:00:00Z","timestamp":1769731200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T00:00:00Z","timestamp":1771977600000},"content-version":"vor","delay-in-days":26,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009827","name":"Alexandria University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100009827","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aim<\/jats:title>\n                    <jats:p>This study aimed to determine the clinical and radiographic efficacy of custom-made 3D PEEK plates in comparison with 3D titanium plates for the management of mandibular angle fractures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients and methods<\/jats:title>\n                    <jats:p>\n                      Eighteen patients with recent mandibular angle fractures indicated for open reduction and internal fixation were randomly allocated into two groups. The study group (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20099) underwent fixation with custom-made 3D PEEK plates, while the control group (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20099) received prebent 3D titanium plates adapted on virtually reduced models. Primary outcomes were bite-force recovery and bone-density (Hounsfield units, HU) at the fracture line measured on CT immediately post-op and at 12\u00a0weeks. Secondary outcomes included operative time, occlusion, interfragmentary stability and wound healing.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      By the end of follow-up, Bite force increased significantly over time in both groups (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001) with no between-group differences at any time point. Mean bone density increased from 811.1\u2009\u00b1\u200968.2 HU to 1225.1\u2009\u00b1\u2009111.7 HU in the PEEK group and from 809.0\u2009\u00b1\u200962.1 HU to 1248.3\u2009\u00b1\u200992.3 HU in the titanium group (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001); between-group differences were not significant. Operative time, occlusion outcomes and wound healing were similar between both groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Custom-made 3D PEEK plates achieved comparable clinical, radiographic, and functional outcomes to 3D titanium plates, suggesting that PEEK is a viable alternative for mandibular angle fracture fixation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration<\/jats:title>\n                    <jats:p>Trial registered at (ClinicalTrials.gov\/NCT07156812\/2025\u201308-28).<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-025-07646-z","type":"journal-article","created":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T04:49:37Z","timestamp":1769748577000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Custom-made 3D PEEK plates versus 3D titanium plates for mandibular angle fracture fixation: a randomized clinical trial"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6491-7614","authenticated-orcid":false,"given":"Aliaa Osama","family":"Kamal","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed Mamdouh","family":"Shaaban","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7959-8812","authenticated-orcid":false,"given":"Mohamed Mamdouh","family":"Shokry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-8442-2810","authenticated-orcid":false,"given":"Ibrahim Mohamed","family":"Abdelhamed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,30]]},"reference":[{"issue":"2","key":"7646_CR1","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1007\/s12663-022-01750-1","volume":"23","author":"A Hesham","year":"2024","unstructured":"Hesham A, Geiger J, Alshamrani Y, Sawatari Y. Can the mechanism of injury impact the location of a mandibular fracture? A systematic review. J Maxillofac Oral Surg. 2024;23(2):363\u201370. https:\/\/doi.org\/10.1007\/s12663-022-01750-1.","journal-title":"J Maxillofac Oral Surg"},{"issue":"2","key":"7646_CR2","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.coms.2008.12.004","volume":"21","author":"E Ellis III","year":"2009","unstructured":"Ellis E III. Management of fractures through the angle of the mandible. Oral Maxillofac Surg Clin North Am. 2009;21(2):163\u201374.","journal-title":"Oral Maxillofac Surg Clin North Am"},{"issue":"10","key":"7646_CR3","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1053\/joms.2001.26726","volume":"59","author":"RH Haug","year":"2001","unstructured":"Haug RH, Fattahi TT, Goltz M. A biomechanical evaluation of mandibular angle fracture plating techniques. J Oral Maxillofac Surg. 2001;59(10):1199\u2013210. https:\/\/doi.org\/10.1053\/joms.2001.26726.","journal-title":"J Oral Maxillofac Surg"},{"issue":"7","key":"7646_CR4","doi-asserted-by":"publisher","first-page":"2079","DOI":"10.1007\/s10856-010-4084-7","volume":"21","author":"JR Sarot","year":"2010","unstructured":"Sarot JR, Contar CM, Cruz AC, de Souza Magini R. Evaluation of the stress distribution in CFR-PEEK dental implants by the three-dimensional finite element method. J Mater Sci Mater Med. 2010;21(7):2079\u201385. https:\/\/doi.org\/10.1007\/s10856-010-4084-7.","journal-title":"J Mater Sci Mater Med"},{"key":"7646_CR5","doi-asserted-by":"publisher","unstructured":"Abaas RA, Salah KA, Mounir R. Clinical assessment of Open Reduction Internal Fixation (ORIF) of Mandibular Body Fractures Using Computer-Assisted Polyetherether Ketone (PEEK) Custom Made Plates Versus Conventional Titanium Plates: A Randomized Clinical Trial. Indian Journal of Public Health Research & Development. 2021;12(2).https:\/\/doi.org\/10.37506\/ijphrd.v12i2.14139.","DOI":"10.37506\/ijphrd.v12i2.14139"},{"issue":"7","key":"7646_CR6","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1007\/s10856-016-5731-4","volume":"27","author":"IV Panayotov","year":"2016","unstructured":"Panayotov IV, Orti V, Cuisinier F, Yachouh J. Polyetheretherketone (PEEK) for medical applications. J Mater Sci Mater Med. 2016;27(7):118. https:\/\/doi.org\/10.1007\/s10856-016-5731-4.","journal-title":"J Mater Sci Mater Med"},{"issue":"2","key":"7646_CR7","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1177\/1943387520952684","volume":"14","author":"R Kasper","year":"2021","unstructured":"Kasper R, Winter K, Pietzka S, Schramm A, Wilde F. Biomechanical in vitro study on the stability of patient-specific CAD\/CAM mandibular reconstruction plates: a comparison between selective laser melted, milled, and hand-bent plates. Craniomaxillofacial Trauma & Reconstruction. 2021;14(2):135\u201343. https:\/\/doi.org\/10.1177\/1943387520952684.","journal-title":"Craniomaxillofacial Trauma & Reconstruction."},{"issue":"1","key":"7646_CR8","doi-asserted-by":"publisher","first-page":"8202653","DOI":"10.1155\/2016\/8202653","volume":"2016","author":"D Almasi","year":"2016","unstructured":"Almasi D, Iqbal N, Sadeghi M, Sudin I, Abdul Kadir MR, Kamarul T. Preparation methods for improving PEEK\u2019s bioactivity for orthopedic and dental application: a review. Int J Biomater. 2016;2016(1):8202653. https:\/\/doi.org\/10.1155\/2016\/8202653.","journal-title":"Int J Biomater"},{"issue":"2","key":"7646_CR9","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1016\/j.tdj.2015.05.001","volume":"12","author":"LN Melek","year":"2015","unstructured":"Melek LN, El Mahallawy A, Sharara A. Evaluation of the 3-dimensional threadlock plate in the management of mandibular angle fractures: a clinical and radiographic study. Tanta Dent J. 2015;12(2):140\u20138. https:\/\/doi.org\/10.1016\/j.tdj.2015.05.001.","journal-title":"Tanta Dent J"},{"issue":"2","key":"7646_CR10","doi-asserted-by":"publisher","first-page":"125","DOI":"10.21608\/ADJALEXU.2020.88449","volume":"45","author":"NY Dessoky","year":"2020","unstructured":"Dessoky NY, El-Mahallawy AS, Fahmy MH, Khalil MM. Use of custom made peek plates for treatment of mandibular fracture. Alexandria Dent J. 2020;45(2):125\u20138. https:\/\/doi.org\/10.21608\/ADJALEXU.2020.88449.","journal-title":"Alexandria Dent J."},{"issue":"1","key":"7646_CR11","doi-asserted-by":"publisher","first-page":"103","DOI":"10.4055\/cios.2014.6.1.103","volume":"6","author":"J Kim","year":"2014","unstructured":"Kim J, Shin W. How to do random allocation (randomization). Clin Orthop Surg. 2014;6(1):103\u20139.","journal-title":"Clin Orthop Surg"},{"issue":"1","key":"7646_CR12","doi-asserted-by":"publisher","first-page":"59","DOI":"10.21608\/adjalexu.2024.288674.1506","volume":"50","author":"IM Abdelhamed","year":"2025","unstructured":"Abdelhamed IM, Khalil A, El-Mahallawy Y. Evaluation of using 3D-interlocking miniplates for fixation of mandibular fractures in the mental foramen region. A clinical and radiographic study. Alexandria Dent J. 2025;50(1):59\u201366. https:\/\/doi.org\/10.21608\/adjalexu.2024.288674.1506.","journal-title":"Alexandria Dent J"},{"issue":"4","key":"7646_CR13","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1563\/AAID-JOI-D-10-00101","volume":"38","author":"D Flanagan","year":"2012","unstructured":"Flanagan D, Ilies H, O\u2019Brien B, McManus A, Larrow B. Jaw bite force measurement device. J Oral Implantol. 2012;38(4):361\u20134. https:\/\/doi.org\/10.1563\/AAID-JOI-D-10-00101.","journal-title":"J Oral Implantol"},{"issue":"1","key":"7646_CR14","doi-asserted-by":"publisher","first-page":"36","DOI":"10.26502\/acbr.50170148","volume":"5","author":"K Gorad","year":"2021","unstructured":"Gorad K, Rahate V, Shinde G, Taralekar G, Prabhu V, Singh L. Use of Southampton scoring for wound healing in post-surgical patients: our experience in semi-urban setup. Arch Clin Biomed Res. 2021;5(1):36\u201341. https:\/\/doi.org\/10.26502\/acbr.50170148.","journal-title":"Arch Clin Biomed Res"},{"key":"7646_CR15","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.jelekin.2016.08.005","volume":"30","author":"M Testa","year":"2016","unstructured":"Testa M, Di Marco A, Pertusio R, Van Roy P, Cattrysse E, Roatta S. A validation study of a new instrument for low cost bite force measurement. J Electromyogr Kinesiol. 2016;30:243\u20138. https:\/\/doi.org\/10.1016\/j.jelekin.2016.08.005.","journal-title":"J Electromyogr Kinesiol"},{"issue":"6","key":"7646_CR16","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1016\/j.injury.2017.03.035","volume":"48","author":"M Guzzini","year":"2017","unstructured":"Guzzini M, Lanzetti RM, Lupariello D, Morelli F, Princi G, Perugia D, et al. . Comparison between carbon-peek plate and conventional stainless steal plate in ankle fractures. A prospective study of two years follow up. Injury. 2017;48(6):1249\u201352.","journal-title":"Injury"},{"issue":"3","key":"7646_CR17","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1055\/s-0034-1374061","volume":"7","author":"A Mabrouk","year":"2014","unstructured":"Mabrouk A, Helal H, Mohamed AR, Mahmoud N. Incidence, etiology, and patterns of maxillofacial fractures in Ain-Shams University, Cairo, Egypt: a 4-year retrospective study. Craniomaxillofac Trauma Reconstr. 2014;7(3):224\u201332. https:\/\/doi.org\/10.1055\/s-0034-1374061.","journal-title":"Craniomaxillofac Trauma Reconstr"},{"issue":"3","key":"7646_CR18","doi-asserted-by":"publisher","first-page":"747","DOI":"10.21608\/asjs.2012.179378","volume":"5","author":"I Kamel","year":"2012","unstructured":"Kamel I, Ghanem M. Mandibular fracture trauma following the Egyptian revolution in Ain Shams University Hospital: Epidemiological study. Ain Shams Journal of Surgery. 2012;5(3):747\u201353.","journal-title":"Ain Shams Journal of Surgery"},{"key":"7646_CR19","doi-asserted-by":"publisher","first-page":"107840","DOI":"10.1016\/j.aap.2024.107840","volume":"210","author":"I Mohamad","year":"2025","unstructured":"Mohamad I. Gender disparities in rural motorcycle accidents: a neural network analysis of travel behavior impact. Accid Anal Prev. 2025;210:107840. https:\/\/doi.org\/10.1016\/j.aap.2024.107840.","journal-title":"Accid Anal Prev"},{"issue":"4","key":"7646_CR20","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1007\/s12663-013-0542-3","volume":"13","author":"P Pattar","year":"2014","unstructured":"Pattar P, Shetty S, Degala S. A prospective study on management of mandibular angle fracture. J Maxillofac Oral Surg. 2014;13(4):592\u20138. https:\/\/doi.org\/10.1007\/s12663-013-0542-3.","journal-title":"J Maxillofac Oral Surg"},{"key":"7646_CR21","doi-asserted-by":"publisher","unstructured":"Bilal Y, Rahim AU, Gul SM, Warraich RA. Outcomes of extra oral versus intraoral approach for Mandibular angle fracture reduction. J Pak Med Assoc. 2020;70(12(A)):2088-91.https:\/\/doi.org\/10.47391\/JPMA.673.","DOI":"10.47391\/JPMA.673"},{"issue":"9","key":"7646_CR22","doi-asserted-by":"publisher","first-page":"1645","DOI":"10.1016\/j.jcms.2018.05.047","volume":"46","author":"A Naros","year":"2018","unstructured":"Naros A, Weise H, Tilsen F, Hoefert S, Naros G, Krimmel M, et al. Three-dimensional accuracy of mandibular reconstruction by patient-specific pre-bent reconstruction plates using an \u201cin-house\u201d 3D-printer. Journal of Cranio-Maxillofacial Surgery. 2018;46(9):1645\u201351.","journal-title":"Journal of Cranio-Maxillofacial Surgery"},{"issue":"3","key":"7646_CR23","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1055\/s-0033-1349213","volume":"6","author":"AS Xue","year":"2013","unstructured":"Xue AS, Koshy JC, Wolfswinkel EM, Weathers WM, Marsack KP, Hollier LH Jr. A Prospective Study of Strut versus Miniplate for Fractures of Mandibular Angle. Craniomaxillofac Trauma Reconstr. 2013;6(3):191\u20136. https:\/\/doi.org\/10.1055\/s-0033-1349213.","journal-title":"Craniomaxillofac Trauma Reconstr."},{"issue":"6","key":"7646_CR24","doi-asserted-by":"publisher","first-page":"752","DOI":"10.1016\/j.tripleo.2007.03.014","volume":"104","author":"A Alkan","year":"2007","unstructured":"Alkan A, Celebi N, Ozden B, Bas B, Inal S. Biomechanical comparison of different plating techniques in repair of mandibular angle fractures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;104(6):752\u20136. https:\/\/doi.org\/10.1016\/j.tripleo.2007.03.014.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod."},{"issue":"3","key":"7646_CR25","doi-asserted-by":"publisher","first-page":"177","DOI":"10.21608\/adjalexu.2022.145417.1289","volume":"47","author":"NM Abdelmoneim","year":"2022","unstructured":"Abdelmoneim NM, El Mahallawy AS, Soliman MM, Noureldin M, Gamaleldin OA. Treatment of pediatric mandibular fractures using customized computer assisted PEEK plates. Alexandria Dent J. 2022;47(3):177\u201384.","journal-title":"Alexandria Dent J"},{"issue":"6","key":"7646_CR26","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1016\/j.ijom.2014.02.002","volume":"43","author":"EA Al-Moraissi","year":"2014","unstructured":"Al-Moraissi EA, El-Sharkawy TM, El-Ghareeb TI, Chrcanovic BR. Three-dimensional versus standard miniplate fixation in the management of mandibular angle fractures: a systematic review and meta-analysis. Int J Oral Maxillofac Surg. 2014;43(6):708\u201316. https:\/\/doi.org\/10.1016\/j.ijom.2014.02.002.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"20","key":"7646_CR27","doi-asserted-by":"publisher","first-page":"5491","DOI":"10.14260\/jemds\/2014\/2618","volume":"3","author":"S Tiwari","year":"2014","unstructured":"Tiwari S, Chauhan M, Shahapurkar V, Akhtar MJ, Grover A, Prashad S, et al. Importance of Southampton wound grading system in surgical site infection. J Evol Med Dent Sci. 2014;3(20):5491\u20136.","journal-title":"J Evol Med Dent Sci"},{"issue":"6","key":"7646_CR28","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1097\/00004728-200011000-00015","volume":"24","author":"KD Hopper","year":"2000","unstructured":"Hopper KD, Wang MP, Kunselman AR. The use of clinical CT for baseline bone density assessment. J Comput Assist Tomogr. 2000;24(6):896\u20139. https:\/\/doi.org\/10.1097\/00004728-200011000-00015.","journal-title":"J Comput Assist Tomogr"},{"issue":"2","key":"7646_CR29","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/s10006-012-0374-1","volume":"18","author":"BR Chrcanovic","year":"2014","unstructured":"Chrcanovic BR. Fixation of mandibular angle fractures: clinical studies. Oral Maxillofac Surg. 2014;18(2):123\u201352. https:\/\/doi.org\/10.1007\/s10006-012-0374-1.","journal-title":"Oral Maxillofac Surg"},{"issue":"2","key":"7646_CR30","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1055\/s-0039-1697833","volume":"4","author":"D Koc","year":"2010","unstructured":"Koc D, Dogan A, Bek B. Bite force and influential factors on bite force measurements: a literature review. Eur J Dent. 2010;4(2):223\u201332.","journal-title":"Eur J Dent"},{"issue":"5","key":"7646_CR31","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1016\/j.joms.2008.12.032","volume":"67","author":"ST Lovald","year":"2009","unstructured":"Lovald ST, Wagner JD, Baack B. Biomechanical optimization of bone plates used in rigid fixation of mandibular fractures. J Oral Maxillofac Surg. 2009;67(5):973\u201385. https:\/\/doi.org\/10.1016\/j.joms.2008.12.032.","journal-title":"J Oral Maxillofac Surg"},{"issue":"4","key":"7646_CR32","doi-asserted-by":"publisher","first-page":"1386","DOI":"10.1007\/s12663-022-01699-1","volume":"21","author":"S Saxena","year":"2022","unstructured":"Saxena S, Giri KY, Sharma P, Niranjanaprasad IB, Dandriyal R, Abhishek K, et al. Comparative assessment of clinical and quality of life outcomes in mandibular angle fractures treated with standard and three-dimensional mini-plates. J Maxillofac Oral Surg. 2022;21(4):1386\u201392. https:\/\/doi.org\/10.1007\/s12663-022-01699-1.","journal-title":"J Maxillofac Oral Surg"},{"issue":"Suppl 1","key":"7646_CR33","doi-asserted-by":"publisher","first-page":"S26","DOI":"10.4103\/2231-0762.144575","volume":"4","author":"S Kumar","year":"2014","unstructured":"Kumar S, Gattumeedhi SR, Sankhla B, Garg A, Ingle E, Dagli N. Comparative evaluation of bite forces in patients after treatment of mandibular fractures with miniplate osteosynthesis and internal locking miniplate osteosynthesis. J Int Soc Prev Community Dent. 2014;4(Suppl 1):S26-31. https:\/\/doi.org\/10.4103\/2231-0762.144575.","journal-title":"J Int Soc Prev Community Dent."},{"issue":"9","key":"7646_CR34","doi-asserted-by":"publisher","first-page":"1171","DOI":"10.1016\/j.bjps.2014.04.038","volume":"67","author":"KA Rodby","year":"2014","unstructured":"Rodby KA, Turin S, Jacobs RJ, Cruz JF, Hassid VJ, Kolokythas A, et al. Advances in oncologic head and neck reconstruction: systematic review and future considerations of virtual surgical planning and computer aided design\/computer aided modeling. J Plast Reconstr Aesthet Surg. 2014;67(9):1171\u201385. https:\/\/doi.org\/10.1016\/j.bjps.2014.04.038.","journal-title":"J Plast Reconstr Aesthet Surg"},{"issue":"2","key":"7646_CR35","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1097\/SCS.0000000000003313","volume":"28","author":"N Patel","year":"2017","unstructured":"Patel N, Kim B, Zaid W. Use of virtual surgical planning for simultaneous maxillofacial osteotomies and custom polyetheretherketone implant in secondary orbito-frontal reconstruction: importance of restoring orbital volume. J Craniofac Surg. 2017;28(2):387\u201390. https:\/\/doi.org\/10.1097\/SCS.0000000000003313.","journal-title":"J Craniofac Surg"},{"issue":"4","key":"7646_CR36","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1016\/j.cegh.2019.03.001","volume":"7","author":"A Haleem","year":"2019","unstructured":"Haleem A, Javaid M. Polyether ether ketone (PEEK) and its manufacturing of customised 3D printed dentistry parts using additive manufacturing. Clinical Epidemiology and Global Health. 2019;7(4):654\u201360.","journal-title":"Clinical Epidemiology and Global Health"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-025-07646-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-07646-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-025-07646-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T11:17:55Z","timestamp":1772018275000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-025-07646-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,30]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["7646"],"URL":"https:\/\/doi.org\/10.1186\/s12903-025-07646-z","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,30]]},"assertion":[{"value":"10 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"An ethical approval statement was added to the manuscript and the approval was granted by the Ethics Committee Faculty of Dentistry Alexandria University (IRB NO: 00010556\u201312\/2021). All patients signed informed consent before the start of the treatment protocol. All methods were carried out per\u00a0Helsinki Declaration guidelines. Study was registered in (clinicaltrials.gov\/NCT07156812\/2025\u201308-28).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from all participants for the publication of their personal and clinical details and any accompanying images.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"384"}}