{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T10:42:28Z","timestamp":1770720148958,"version":"3.49.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T00:00:00Z","timestamp":1768348800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T00:00:00Z","timestamp":1770595200000},"content-version":"vor","delay-in-days":26,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100005911","name":"Najran University","doi-asserted-by":"publisher","award":["NU\/EFP\/MRC\/13\/255"],"award-info":[{"award-number":["NU\/EFP\/MRC\/13\/255"]}],"id":[{"id":"10.13039\/501100005911","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"DOI":"10.1186\/s12903-026-07678-z","type":"journal-article","created":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T07:05:52Z","timestamp":1768374352000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Finite element study on the effect of bruxism on the fracture resistance of maxillary zirconia fixed partial dentures with varying anterior inter-implant distances"],"prefix":"10.1186","volume":"26","author":[{"given":"Omir","family":"Aldowah","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammed","family":"Zarbah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdulrahman","family":"Aseri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmed","family":"Almeshari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed I.","family":"El-Anwar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdel Naser M.","family":"Emam","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hussain","family":"Alharthi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,1,14]]},"reference":[{"key":"7678_CR1","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1111\/joor.12291","volume":"42","author":"P Malo","year":"2015","unstructured":"Malo P, de Ara\u00fajo Nobre MA, Lopes AV, Rodrigues R. Immediate loading short implants inserted on low bone quantity for the rehabilitation of the edentulous maxilla using an all-on-4 design. J Oral Rehabil. 2015;42:615\u201323.","journal-title":"J Oral Rehabil"},{"key":"7678_CR2","first-page":"8890833","volume":"2020","author":"R Aiuto","year":"2020","unstructured":"Aiuto R, Barbieri C, Garcovich D, Dioguardi M, Redaelli M, De Micheli L. Rehabilitation of edentulous jaws with full-arch fixed implant-supported prostheses: an approach with short and ultrashort implants and metal-free materials. Case Rep Dent. 2020;2020:8890833.","journal-title":"Case Rep Dent"},{"key":"7678_CR3","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1034\/j.1600-0501.2002.130207.x","volume":"13","author":"PS Wright","year":"2002","unstructured":"Wright PS, Glantz PO, Randow K, Watson RM. The effects of fixed and removable implant-stabilised prostheses on posterior mandibular residual ridge resorption. Clin Oral Implants Res. 2002;13:169\u201374.","journal-title":"Clin Oral Implants Res"},{"key":"7678_CR4","doi-asserted-by":"publisher","first-page":"104370","DOI":"10.1016\/j.jmbbm.2021.104370","volume":"116","author":"H Okawara","year":"2021","unstructured":"Okawara H, Arai Y, Matsuno H, Marci\u00e1n P, Bor\u00e1k L, Aoki K, et al. Effect of load-induced local mechanical strain on peri-implant bone cell activity related to bone resorption and formation in mice: an analysis of histology and strain distributions. J Mech Behav Biomed Mater. 2021;116:104370.","journal-title":"J Mech Behav Biomed Mater"},{"key":"7678_CR5","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1016\/j.prosdent.2022.02.018","volume":"127","author":"W Yu","year":"2022","unstructured":"Yu W, Li X, Ma X, Xu X. Biomechanical analysis of inclined and cantilever design with different implant framework materials in mandibular complete-arch implant restorations. J Prosthet Dent. 2022;127:783.","journal-title":"J Prosthet Dent"},{"key":"7678_CR6","doi-asserted-by":"publisher","first-page":"103490","DOI":"10.1016\/j.jmbbm.2019.103490","volume":"102","author":"J Zhong","year":"2020","unstructured":"Zhong J, Guazzato M, Chen J, Zhang Z, Sun G, Huo X, et al. Effect of different implant configurations on Biomechanical behavior of full-arch implant-supported mandibular monolithic zirconia fixed prostheses. J Mech Behav Biomed Mater. 2020;102:103490.","journal-title":"J Mech Behav Biomed Mater"},{"key":"7678_CR7","first-page":"91","volume-title":"Risk factors in implant dentistry: simplified clinical analysis for predictable treatment","author":"F Renouard","year":"1999","unstructured":"Renouard F, Rangert B. Risk factors in implant dentistry: simplified clinical analysis for predictable treatment. Chicago: Quintessence; 1999. pp. 91\u20134."},{"key":"7678_CR8","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/j.prosdent.2013.06.019","volume":"111","author":"CB Correa","year":"2014","unstructured":"Correa CB, Margonar R, Noritomi PY, Vaz LG. Mechanical behavior of dental implants in different positions in the rehabilitation of the anterior maxilla. J Prosthet Dent. 2014;111:301\u20139.","journal-title":"J Prosthet Dent"},{"key":"7678_CR9","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1111\/joor.12011","volume":"40","author":"F Lobbezoo","year":"2013","unstructured":"Lobbezoo F, Ahlberg J, Glaros AG, et al. Bruxism defined and graded: an international consensus. J Oral Rehabil. 2013;40:2\u20134.","journal-title":"J Oral Rehabil"},{"key":"7678_CR10","doi-asserted-by":"publisher","first-page":"99","DOI":"10.11607\/jop.921","volume":"27","author":"D Manfredini","year":"2013","unstructured":"Manfredini D, Winocur E, Guarda-Nardini L, et al. Epidemiology of Bruxism in adults: a systematic review of the literature. J Orofac Pain. 2013;27:99\u2013110.","journal-title":"J Orofac Pain"},{"key":"7678_CR11","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/j.tripleo.2007.08.007","volume":"105","author":"RCG De Oliveira","year":"2008","unstructured":"De Oliveira RCG, Leles CR, Normanha LM, et al. Assessments of trabecular bone density at implant sites on CT images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008;105:231\u20138.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"issue":"5","key":"7678_CR12","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1007\/s40846-024-00896-2","volume":"44","author":"J Zhang","year":"2024","unstructured":"Zhang J, Hou H, Chen P, Song L, Hu F, Yu Y. Biomechanical performance of different implant spacings and placement angles in partial fixed denture prosthesis restorations: A finite element analysis. J Med Biol Eng. 2024;44(5):685\u201395.","journal-title":"J Med Biol Eng"},{"issue":"48","key":"7678_CR13","doi-asserted-by":"publisher","first-page":"19194","DOI":"10.1039\/C6DT03484E","volume":"45","author":"C Gautam","year":"2016","unstructured":"Gautam C, Joyner J, Gautam A, Rao J, Vajtai R. Zirconia based dental ceramics: structure, mechanical properties, biocompatibility and applications. Dalton Trans. 2016;45(48):19194\u2013215.","journal-title":"Dalton Trans"},{"key":"7678_CR14","doi-asserted-by":"publisher","first-page":"103490","DOI":"10.1016\/j.jmbbm.2019.103490","volume":"103","author":"J Zhong","year":"2020","unstructured":"Zhong J, Guazzato M, Chen J, Zhang Z, Sun G. Effect of different implant configurations on Biomechanical behavior of full-arch implant-supported mandibular monolithic zirconia fixed prostheses. J Mech Behav Biomed Mater. 2020;103:103490.","journal-title":"J Mech Behav Biomed Mater"},{"key":"7678_CR15","doi-asserted-by":"crossref","unstructured":"Lafon A, Hoornaert A, Le Loch S Jr, Le H\u00e9cho H, Chaux AG. Implant number and distribution for implant-supported fixed complete dentures according to three-dimensional finite element analysis: a scoping review: implant number and distribution for implant-supported fixed complete dentures according to three-dimensional finite element analysis: a scoping review. Br Dent J. 2025 Aug;15:1\u20136.","DOI":"10.1038\/s41415-025-8641-3"},{"issue":"S1","key":"7678_CR16","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1111\/jopr.13321","volume":"30","author":"G Goldstein","year":"2021","unstructured":"Goldstein G, Goodacre C, Taylor T. Occlusal schemes for implant restorations: best evidence consensus statement. J Prosthodont. 2021;30(S1):34\u201343.","journal-title":"J Prosthodont"},{"key":"7678_CR17","first-page":"1","volume":"Feb","author":"A Berzaghi","year":"2025","unstructured":"Berzaghi A, Testori T, Scaini R, Bortolini S. Occlusion and Biomechanical risk factors in implant-supported full-arch fixed dental prostheses\u2014narrative review. J Pers Med. 2025;Feb:1\u20139.","journal-title":"J Pers Med"},{"issue":"S1","key":"7678_CR18","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1111\/jopr.13334","volume":"30","author":"SK Lee","year":"2021","unstructured":"Lee SK, Salinas TJ, Wiens JP. The effect of patient specific factors on occlusal forces generated: best evidence consensus statement. J Prosthodont. 2021;30(S1):52\u201360.","journal-title":"J Prosthodont"},{"key":"7678_CR19","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1016\/j.prosdent.2017.07.016","volume":"119","author":"CF Amaral","year":"2018","unstructured":"Amaral CF, Gomes RS, Garcia RCR, Cury AADB. Stress distribution of single-implant\u2013retained overdenture reinforced with a framework: a finite element analysis study. J Prosthet Dent. 2018;119:791\u20136.","journal-title":"J Prosthet Dent"},{"key":"7678_CR20","unstructured":"Cook RD.Concepts and Applications of Finite Element Analysis.4th ed. Hoboken, NJ: John Wiley & Sons; 2007."},{"key":"7678_CR21","doi-asserted-by":"publisher","first-page":"81","DOI":"10.11607\/ijp.6247","volume":"33","author":"DM Elias","year":"2020","unstructured":"Elias DM, Valerio CS, de Oliveira DD, Manzi FR, Zen\u00f3bio EG, Seraidarian PI. Evaluation of different heights of prosthetic crowns supported by an ultra-short implant using three-dimensional finite element analysis. Int J Prosthodont. 2020;33:81\u201390.","journal-title":"Int J Prosthodont"},{"key":"7678_CR22","doi-asserted-by":"publisher","first-page":"105309","DOI":"10.1016\/j.jmbbm.2022.105309","volume":"133","author":"M Aldesoki","year":"2022","unstructured":"Aldesoki M, Bourauel C, Morsi T, El-Anwar MI, Aboelfadl AK, Elshazly TM. Biomechanical behavior of endodontically treated premolars restored with different endocrown designs: finite element study. J Mech Behav Biomed Mater. 2022;133:105309.","journal-title":"J Mech Behav Biomed Mater"},{"key":"7678_CR23","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.dental.2017.09.005","volume":"34","author":"O R\u00f6hrle","year":"2018","unstructured":"R\u00f6hrle O, Pullan AJ, Nielsen PM. Occlusal loading during biting from an experimental and simulation point of view. Dent Mater. 2018;34:58\u201368.","journal-title":"Dent Mater"},{"key":"7678_CR24","volume-title":"Management of temporomandibular disorders and occlusion","author":"JP Okeson","year":"2013","unstructured":"Okeson JP. Management of temporomandibular disorders and occlusion. St. Louis (MO): Elsevier\/Mosby; 2013."},{"key":"7678_CR25","doi-asserted-by":"publisher","first-page":"312","DOI":"10.3390\/met12020312","volume":"12","author":"IP Semenova","year":"2022","unstructured":"Semenova IP, Modina YM, Stotskiy AG, Polyakov AV, Pesin MV. Fatigue properties of Ti alloys with an ultrafine grained structure: challenges and achievements. Metals. 2022;12:312.","journal-title":"Metals"},{"key":"7678_CR26","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1016\/0021-9290(92)90051-2","volume":"25","author":"K Choi","year":"1992","unstructured":"Choi K, Goldstein SA. A comparison of the fatigue behavior of human trabecular and cortical bone tissue. J Biomech. 1992;25:1371\u201381.","journal-title":"J Biomech"},{"key":"7678_CR27","doi-asserted-by":"publisher","first-page":"100730","DOI":"10.1016\/j.imu.2021.100730","volume":"26","author":"K Bataineh","year":"2021","unstructured":"Bataineh K. Experimental and numerical fatigue investigations of CAD\/CAM ceramic crowns under dynamic loads. Inf Med Unlocked. 2021;26:100730.","journal-title":"Inf Med Unlocked"},{"key":"7678_CR28","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1034\/j.1600-0501.2001.120614.x","volume":"12","author":"AM O\u2019Mahony","year":"2001","unstructured":"O\u2019Mahony AM, Williams JL, Spencer P. Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri-implant stress and strain under oblique loading: a finite element study. Clin Oral Implants Res. 2001;12:648\u201357.","journal-title":"Clin Oral Implants Res"},{"key":"7678_CR29","unstructured":"Manfredini M. Evaluation of marginal bone resorption of one-piece implants in full arch rehabilitations with full digital approach [PhD thesis]. Milan: Universit\u00e0 degli Studi di Milano; 2024."},{"key":"7678_CR30","first-page":"48","volume-title":"Contemporary implant dentistry","author":"G Bullis","year":"2020","unstructured":"Bullis G. Functional basis for dental implant design. In: Misch CE, editor. Contemporary implant dentistry. 4th ed. Philadelphia: Mosby; 2020. pp. 48\u201356.","edition":"4"},{"key":"7678_CR31","doi-asserted-by":"publisher","first-page":"258","DOI":"10.15171\/joddd.2018.040","volume":"12","author":"T Ghaffari","year":"2018","unstructured":"Ghaffari T, Hamedirad F. Evaluation of stress distribution in bone and three-unit fixed implant-supported prostheses with zirconia and titanium abutments: a 3D finite element analysis. J Dent Res Dent Clin Dent Prospects. 2018;12:258\u201364.","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"key":"7678_CR32","first-page":"198","volume":"47","author":"A Ravida","year":"2021","unstructured":"Ravida A, Galli M, Bianchi M, Parisi E, et al. Clinical outcomes of short implants (\u2264\u20096\u00a0mm) placed between two adjacent teeth\/implants or in the most distal position: a systematic review and meta-analysis. J Oral Implantol. 2021;47:198\u2013205.","journal-title":"J Oral Implantol"},{"key":"7678_CR33","doi-asserted-by":"publisher","first-page":"90","DOI":"10.15171\/joddd.2019.014","volume":"13","author":"MR Anaraki","year":"2019","unstructured":"Anaraki MR, Torab A, Rad TM. Comparison of stress in implant-supported monolithic zirconia fixed partial dentures between canine guidance and group function occlusal patterns: a finite element study. J Dent Res Dent Clin Dent Prospects. 2019;13:90\u20137.","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"key":"7678_CR34","doi-asserted-by":"publisher","first-page":"2133","DOI":"10.1016\/j.jbiomech.2005.04.033","volume":"39","author":"L Rapillard","year":"2006","unstructured":"Rapillard L, Charlebois M, Zysset PK. Compressive fatigue behavior of human vertebral trabecular bone. J Biomech. 2006;39:2133\u20139.","journal-title":"J Biomech"},{"key":"7678_CR35","unstructured":"Craig RR Jr, Talleff EM. Mechanics of Materials. 4th ed. Hoboken, NJ: John Wiley & Sons; 2020."},{"key":"7678_CR36","doi-asserted-by":"publisher","first-page":"5826","DOI":"10.3390\/app10175826","volume":"10","author":"PJ Lin","year":"2020","unstructured":"Lin PJ, Su KC. Biomechanical design application on the effect of different occlusion conditions on dental implants with different positions: a finite element analysis. Appl Sci. 2020;10:5826.","journal-title":"Appl Sci"},{"issue":"1","key":"7678_CR37","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1111\/joor.13567","volume":"51","author":"B H\u00e4ggman-Henrikson","year":"2024","unstructured":"H\u00e4ggman-Henrikson B, Ali D, Aljamal M, Chrcanovic BR. Bruxism and dental implants: A systematic review and meta\u2010analysis. J Rehabil. 2024;51(1):202\u201317.","journal-title":"J Rehabil"},{"key":"7678_CR38","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1902\/annals.2003.8.1.328","volume":"8","author":"SS Wallace","year":"2003","unstructured":"Wallace SS, Froum SJ. Effect of maxillary sinus augmentation on the survival of endosseous dental implants. A systematic review. Ann Periodontol. 2003;8:328\u201343.","journal-title":"Ann Periodontol"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-07678-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-07678-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-07678-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T15:07:46Z","timestamp":1770649666000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-07678-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,14]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["7678"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-07678-z","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,14]]},"assertion":[{"value":"20 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This research was approved by Research Ethics Committee, Approval No. 202411-076- 027068\u2013059834, Najran University, Kingdom of Saudi Arabia. The study was performed in compliance with the Declaration of Helsinki. CBCT was extracted retrospectively and anonymised earlier for analysis. The participant signed a written informed consent for the use of CBCT data for research purposes.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not Applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"265"}}