{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T02:28:18Z","timestamp":1788402498762,"version":"build-2803163510"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,21]],"date-time":"2026-03-21T00:00:00Z","timestamp":1774051200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"vor","delay-in-days":19,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"DOI":"10.1186\/s12903-026-07851-4","type":"journal-article","created":{"date-parts":[[2026,3,21]],"date-time":"2026-03-21T07:44:48Z","timestamp":1774079088000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Comparison of virtual treatment planning outcomes designed by two commercially available software in treatment of anterior teeth crowding using in-house aligners"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7877-9275","authenticated-orcid":false,"given":"Aliaa A.","family":"Khadre","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zaki","family":"Hakami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdullah M.","family":"Aldrees","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,21]]},"reference":[{"issue":"5","key":"7851_CR1","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/0096-6347(46)90053-1","volume":"32","author":"HD Kesling","year":"1946","unstructured":"Kesling HD. Coordinating the predetermined pattern and tooth positioner with conventional treatment. Am J Orthod Oral Surg. 1946;32(5):285\u201393.","journal-title":"Am J Orthod Oral Surg"},{"issue":"3","key":"7851_CR2","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1093\/ejo\/cjr008","volume":"34","author":"M Erkan","year":"2012","unstructured":"Erkan M, Gurel HG, Nur M, Demirel B. Reliability of four different computerized cephalometric analysis programs. Eur J Orthod. 2012;34(3):318\u201321.","journal-title":"Eur J Orthod"},{"issue":"7","key":"7851_CR3","doi-asserted-by":"publisher","first-page":"857","DOI":"10.5005\/jp-journals-10024-2611","volume":"20","author":"AM Alassiry","year":"2019","unstructured":"Alassiry AM. Orthodontic retainers: A contemporary overview. J Contemp Dent Pract. 2019;20(7):857\u201362.","journal-title":"J Contemp Dent Pract"},{"issue":"1","key":"7851_CR4","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1016\/j.ejwf.2021.11.002","volume":"11","author":"M Upadhyay","year":"2022","unstructured":"Upadhyay M, Arqub SA. Biomechanics of clear aligners: hidden truths & first principles. J World Federation Orthodontists. 2022;11(1):12\u201321.","journal-title":"J World Federation Orthodontists"},{"issue":"3","key":"7851_CR5","doi-asserted-by":"publisher","first-page":"140","DOI":"10.4041\/kjod.2019.49.3.140","volume":"49","author":"L Galan-Lopez","year":"2019","unstructured":"Galan-Lopez L, Barcia-Gonzalez J, Plasencia E. A systematic review of the accuracy and efficiency of dental movements with Invisalign\u00ae. Korean J Orthod. 2019;49(3):140\u20139.","journal-title":"Korean J Orthod"},{"issue":"9","key":"7851_CR6","doi-asserted-by":"publisher","first-page":"3118","DOI":"10.3390\/ma15093118","volume":"15","author":"J-H Seo","year":"2022","unstructured":"Seo J-H, Kim M-S, Lee J-H, Eghan-Acquah E, Jeong Y-H, Hong M-H, Kim B, Lee S-J. Biomechanical efficacy and effectiveness of orthodontic treatment with transparent aligners in mild crowding dentition\u2014a finite element analysis. Materials. 2022;15(9):3118.","journal-title":"Materials"},{"issue":"1","key":"7851_CR7","doi-asserted-by":"publisher","first-page":"112","DOI":"10.21608\/eos.2025.427500.1154","volume":"68","author":"AA Khadre","year":"2025","unstructured":"Khadre AA, Alhakami Z, Zahra S, Fiorillo L, Khedr MH. Clear aligner market evolution in MENA region: A study of emerging brands (2020\u20132025). Egypt Orthodontic J. 2025;68(1):112\u201328.","journal-title":"Egypt Orthodontic J"},{"key":"7851_CR8","doi-asserted-by":"crossref","unstructured":"Zhang G, MacCarthy BL, Ivanov D. The cloud, platforms, and digital twins\u2014Enablers of the digital supply chain. The digital supply chain. edn.: Elsevier; 2022. pp. 77\u201391.","DOI":"10.1016\/B978-0-323-91614-1.00005-8"},{"issue":"4","key":"7851_CR9","doi-asserted-by":"publisher","first-page":"e70393","DOI":"10.1002\/ccr3.70393","volume":"13","author":"N Van Tam","year":"2025","unstructured":"Van Tam N, Phuong TT, Van Anh VT, Viet H. Correcting multiple spaces in adult patients with precise tooth movement control using In-House clear aligners. Clin Case Rep. 2025;13(4):e70393.","journal-title":"Clin Case Rep"},{"issue":"1","key":"7851_CR10","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1186\/s12903-024-04522-0","volume":"24","author":"H Gamil","year":"2024","unstructured":"Gamil H, Marzouk E, Zaher A. Virtual bracket removal: a comparative assessment of different software packages. BMC Oral Health. 2024;24(1):770.","journal-title":"BMC Oral Health"},{"issue":"1","key":"7851_CR11","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1186\/s12903-025-05841-6","volume":"25","author":"FY Eid","year":"2025","unstructured":"Eid FY, Sabouni W, Zaher A, Tageldin MA, Elfouly D. Comparison of three-dimensional tooth movements in virtual setups using different software packages for clear aligner therapy. BMC Oral Health. 2025;25(1):549.","journal-title":"BMC Oral Health"},{"issue":"2","key":"7851_CR12","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.ejwf.2023.02.004","volume":"12","author":"M Eliliwi","year":"2023","unstructured":"Eliliwi M, ElShebiny T, De Menezes LM, Stefanovic N, Palomo JM. Comparing virtual setup software programs for clear aligner treatment. J World Federation Orthodontists. 2023;12(2):50\u20135.","journal-title":"J World Federation Orthodontists"},{"issue":"1","key":"7851_CR13","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1186\/s12903-022-02129-x","volume":"22","author":"SM Adel","year":"2022","unstructured":"Adel SM, Vaid NR, El-Harouni N, Kassem H, Zaher AR. Digital model superimpositions: are different software algorithms equally accurate in quantifying linear tooth movements? BMC Oral Health. 2022;22(1):103.","journal-title":"BMC Oral Health"},{"issue":"3","key":"7851_CR14","doi-asserted-by":"publisher","first-page":"259","DOI":"10.2319\/071224-555.1","volume":"95","author":"Y Pan","year":"2025","unstructured":"Pan Y, Zhang Z, Xu T, Chen G. Development and validation of a graph convolutional network (GCN)-based automatic superimposition method for maxillary digital dental models (MDMs). Angle Orthod. 2025;95(3):259\u201365.","journal-title":"Angle Orthod"},{"issue":"3","key":"7851_CR15","doi-asserted-by":"publisher","first-page":"245","DOI":"10.5624\/isd.20250013","volume":"55","author":"M Serafin","year":"2025","unstructured":"Serafin M, Baldini B, Boccalari E, Parravicini F, Zecca PA, Caprioglio A. Accuracy of facial scan registration: A comparison between full-cranium and reduced field-of-view cone-beam computed tomography. Imaging Sci Dentistry. 2025;55(3):245.","journal-title":"Imaging Sci Dentistry"},{"issue":"2","key":"7851_CR16","doi-asserted-by":"publisher","first-page":"175","DOI":"10.3758\/BF03193146","volume":"39","author":"F Faul","year":"2007","unstructured":"Faul F, Erdfelder E, Lang A-G, Buchner A. G* power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39(2):175\u201391.","journal-title":"Behav Res Methods"},{"key":"7851_CR17","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1590\/S1806-83242012000500012","volume":"26","author":"J Rino Neto","year":"2012","unstructured":"Rino Neto J, Silva FPLd, Chilvarquer I, Paiva JBd, Hernandez AM. Hausdorff distance evaluation of orthodontic accessories\u2019 streaking artifacts in 3D model superimposition. Brazilian Oral Res. 2012;26:450\u20136.","journal-title":"Brazilian Oral Res"},{"issue":"1","key":"7851_CR18","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1186\/1472-6831-14-68","volume":"14","author":"M Simon","year":"2014","unstructured":"Simon M, Keilig L, Schwarze J, Jung BA, Bourauel C. Treatment outcome and efficacy of an aligner technique\u2013regarding incisor torque, premolar derotation and molar distalization. BMC Oral Health. 2014;14(1):68.","journal-title":"BMC Oral Health"},{"issue":"1","key":"7851_CR19","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.ajodo.2007.05.018","volume":"135","author":"ND Kravitz","year":"2009","unstructured":"Kravitz ND, Kusnoto B, BeGole E, Obrez A, Agran B. How well does invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with invisalign. Am J Orthod Dentofac Orthop. 2009;135(1):27\u201335.","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"7851_CR20","unstructured":"Raja VV. Clinical evaluation of reliability and accuracy of direct scanning of dentition from CBCT, digital models from CAD CAM with conventional plaster models. Rajiv Gandhi University of Health Sciences (India); 2016."}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-07851-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-07851-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-07851-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T07:53:48Z","timestamp":1775721228000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-07851-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,21]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["7851"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-07851-4","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,21]]},"assertion":[{"value":"18 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval for this study was obtained from the Institutional Review Board (Ethics Committee # REC-44\/11\/694, Standing Committee for Scientific Research of Jazan University \u201cHAPO-10-Z-001\u201d, 2023). As this was a retrospective in-silico study based on previously acquired digital records, informed consent to participate was not required.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"619"}}