{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T21:11:59Z","timestamp":1791839519559,"version":"4.3.4"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T00:00:00Z","timestamp":1770249600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T00:00:00Z","timestamp":1773014400000},"content-version":"vor","delay-in-days":32,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"DOI":"10.1186\/s12903-026-07855-0","type":"journal-article","created":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T06:53:50Z","timestamp":1770274430000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparative in vitro evaluation of the mechanical behavior of implant\u2013abutment connections for zirconia and titanium implants"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-6310-7154","authenticated-orcid":false,"given":"Camila","family":"da Silva Resende","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-0483-5600","authenticated-orcid":false,"given":"Lara R\u00fabia Marques","family":"Nascimento","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-1343-7057","authenticated-orcid":false,"given":"Ol\u00edvia","family":"Francescato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-6008-4347","authenticated-orcid":false,"given":"Rafaela Regina","family":"de Lima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7378-5959","authenticated-orcid":false,"given":"Barbara Magalh\u00e3es Figueiredo","family":"Dias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8628-3122","authenticated-orcid":false,"given":"Dhelfeson Willya","family":"Douglas-de-Oliveira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8885-1138","authenticated-orcid":false,"given":"Frederico Santos","family":"Lages","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,5]]},"reference":[{"issue":"12","key":"7855_CR1","doi-asserted-by":"publisher","first-page":"1122","DOI":"10.5005\/jp-journals-10024-2187","volume":"18","author":"RS de Molon","year":"2017","unstructured":"de Molon RS, Lages FS, Rivera CP, de Souza Faloni AP, Margonar R, Queiroz TP. Evaluation of short and regular implants after prosthesis placement in the mandible: a nonrandomized controlled clinical trial. J Contemp Dent Pract. 2017;18(12):1122\u20139. https:\/\/doi.org\/10.5005\/jp-journals-10024-2187. PMID:29208786.","journal-title":"J Contemp Dent Pract"},{"key":"7855_CR2","doi-asserted-by":"publisher","unstructured":"Buser D, Sennerby L, De Bruyn H. Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions. Periodontol 2000. 2017;73(1):7\u201321. https:\/\/doi.org\/10.1111\/prd.12185. PMID: 28000280.","DOI":"10.1111\/prd.12185"},{"key":"7855_CR3","doi-asserted-by":"publisher","unstructured":"Cionca N, Hashim D, Mombelli A. Zirconia dental implants: where are we now, and where are we heading? Periodontol 2000. 2017;73(1):241\u2013258. https:\/\/doi.org\/10.1111\/prd.12180. PMID: 28000266.","DOI":"10.1111\/prd.12180"},{"issue":"2","key":"7855_CR4","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/j.jpor.2017.07.003","volume":"62","author":"K Sivaraman","year":"2018","unstructured":"Sivaraman K, Chopra A, Narayan AI, Balakrishnan D. Is zirconia a viable alternative to titanium for oral implant? A critical review. J Prosthodont Res. 2018;62(2):121\u201333. https:\/\/doi.org\/10.1016\/j.jpor.2017.07.003. Epub 2017 Aug 18. PMID: 28827030.","journal-title":"J Prosthodont Res"},{"issue":"1","key":"7855_CR5","doi-asserted-by":"publisher","first-page":"24","DOI":"10.4012\/dmj.2019-172","volume":"39","author":"T Hanawa","year":"2020","unstructured":"Hanawa T. Zirconia versus titanium in dentistry: a review. Dent Mater J. 2020;39(1):24\u201336. https:\/\/doi.org\/10.4012\/dmj.2019-172.","journal-title":"Dent Mater J"},{"key":"7855_CR6","doi-asserted-by":"crossref","unstructured":"Francescato O, Souza Rodrigues IN, de Douglas DW, Moreira AN, Magalh\u00e3es CS, Lages FS. Primary Stability and Fracture Resistance of Zirconia and Titanium Implants: A Paired Comparative In Vitro Study. Int J Oral Maxillofac Implants. 2024;31;0(0):1\u201322. doi: 10.11607\/10974. Epub ahead of print. PMID: 38820085.","DOI":"10.11607\/10974"},{"key":"7855_CR7","doi-asserted-by":"publisher","unstructured":"Kim KS, Han JS, Lim YJ. Settling of abutments into implants and changes in removal torque in five different implant-abutment connections. Part 1: Cyclic loading. Int J Oral Maxillofac Implants. 2014;29(5):1079-84. https:\/\/doi.org\/10.11607\/jomi.3383. PMID: 25216133.","DOI":"10.11607\/jomi.3383"},{"key":"7855_CR8","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1111\/j.1600-0501.2012.02425.x","volume":"24","author":"M Payer","year":"2013","unstructured":"Payer M, Arnetzl V, Kirmeier R, Koller M, Arnetzl G, Jakse N. Im mediate provisional restoration of single-piece zirconia implants: A prospective case series - results after 24 months of clinical function. Clin Oral Implants Res. 2013;24:569\u201375.","journal-title":"Clin Oral Implants Res"},{"key":"7855_CR9","doi-asserted-by":"publisher","first-page":"9","DOI":"10.2147\/CCIDE.S231070","volume":"12","author":"MT Hamed","year":"2020","unstructured":"Hamed MT, Abdullah Mously H, Khalid Alamoudi S, Hossam Hashem AB, Hussein Naguib G. A systematic review of screw versus cement retained fixed implant supported reconstructions. Clin Cosmet Investig Dent. 2020;12:9\u201316.","journal-title":"Clin Cosmet Investig Dent"},{"key":"7855_CR10","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1111\/clr.13734","volume":"32","author":"N Cionca","year":"2021","unstructured":"Cionca N, Hashim D, Mombelli A. Two-piece zirconia implants sup porting all-ceramic crowns: Six-year results of a prospective cohort study. Clin Oral Implants Res. 2021;32:695\u2013701.","journal-title":"Clin Oral Implants Res"},{"key":"7855_CR11","doi-asserted-by":"publisher","first-page":"13","DOI":"10.4028\/www.scientific.net\/KEM.345-346.13","volume":"345\u2013346","author":"HJ Kim","year":"2007","unstructured":"Kim HJ, Choe HC, Chung CH, Brantley WA. Deformation of dental abutment screw after tightening and loosening. Key Eng Mater. 2007;345\u2013346:13\u20136. https:\/\/doi.org\/10.4028\/www.scientific.net\/KEM.345-346.13.","journal-title":"Key Eng Mater"},{"issue":"2","key":"7855_CR12","doi-asserted-by":"publisher","first-page":"e145","DOI":"10.1097\/scs.0000000000003330","volume":"28","author":"MS De Paiva","year":"2017","unstructured":"De Paiva MS, de Oliveira SN, Dias JV, da Trindade Neto CG, de Queiroz JR, de Oliveira EA, et al. Influence of two types of connections in driver-retention screw assembly. J Craniofac Surg. 2017;28(2):e145\u20136. 10.1097\/ scs.0000000000003330.","journal-title":"J Craniofac Surg"},{"issue":"1","key":"7855_CR13","doi-asserted-by":"publisher","first-page":"60","DOI":"10.34172\/japid.2023.001","volume":"15","author":"T Ghaffari","year":"2023","unstructured":"Ghaffari T, Nourizadeh A, Shafiei E, Ghasemi S, Mahmoudzadeh M, Ataei K. Evaluation of implant abutment screw head deformation in hexagonal and star designs after successive tightening and loosening. J Adv Periodontol Implant Dent. 2023;15(1):60\u20133. https:\/\/doi.org\/10.34172\/japid.2023.001.","journal-title":"J Adv Periodontol Implant Dent"},{"key":"7855_CR14","doi-asserted-by":"publisher","unstructured":"Assun\u00e7\u00e3o WG, Delben JA, Tabata LF, Bar\u00e3o VA, Gomes EA, Garcia IR Jr. Preload evaluation of different screws in external hexagon joint. Implant Dent. 2012;21(1):46\u201350. https:\/\/doi.org\/10.1097\/ID.0b013e31823fcbce. PMID: 22228458.","DOI":"10.1097\/ID.0b013e31823fcbce"},{"issue":"4","key":"7855_CR15","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1111\/jerd.12494","volume":"31","author":"Y Huang","year":"2019","unstructured":"Huang Y, Wang J. Mechanism of and factors associated with the loosening of the implant abutment screw: A review. J Esthet Restor Dent. 2019;31(4):338\u201345. https:\/\/doi.org\/10.1111\/jerd.12494. Epub 2019 May 31. PMID: 31150572.","journal-title":"J Esthet Restor Dent"},{"key":"7855_CR16","doi-asserted-by":"publisher","unstructured":"Bittencourt ABBC, Neto CLMM, Penitente PA, Pellizzer EP, Dos Santos DM, Goiato MC. Comparison of the Morse Cone Connection with the Internal Hexagon and External Hexagon Connections Based on Microleakage - Review. Prague Med Rep. 2021;122(3):181\u2013190. https:\/\/doi.org\/10.14712\/23362936.2021.15. PMID: 34606430.","DOI":"10.14712\/23362936.2021.15"},{"key":"7855_CR17","unstructured":"Neodent. Neodent Product Catalog 2024. JJGC Ind\u00fastria e Com\u00e9rcio de Materiais Dent\u00e1rios S.A. Curitiba, PR: Ed. 1, 2024. Available at: https:\/\/www.straumann.com\/content\/dam\/media-center\/neodent\/pt-br\/documents\/catalog\/product-catalog\/102_neodent_institutional_catalogue_pt_br_lr.pdf"},{"key":"7855_CR18","unstructured":"Neodent . 2024 [cited 2025 Sep 3]. Available from: https:\/\/www.straumann.com\/content\/dam\/media-center\/neodent\/pt\/documents\/working-protocol\/10790_neodent_zi_workingprotocol_pt_pt_hr.pdf"},{"issue":"2","key":"7855_CR19","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1007\/s00784-020-03513-z","volume":"25","author":"G Thom\u00e9","year":"2021","unstructured":"Thom\u00e9 G, Sandgren R, Bernardes S, Trojan L, Warfving N, Bell\u00f3n B, Pippenger BE. Osseointegration of a novel injection molded 2-piece ceramic dental implant: a study in minipigs. Clin Oral Investig. 2021;25(2):603\u201315. https:\/\/doi.org\/10.1007\/s00784-020-03513-z. Epub 2020 Sep 10. PMID: 32914271.","journal-title":"Clin Oral Investig"},{"issue":"12","key":"7855_CR20","doi-asserted-by":"publisher","first-page":"e05118","DOI":"10.1002\/ccr3.5118","volume":"4","author":"G Thom\u00e9","year":"2021","unstructured":"Thom\u00e9 G, Uhlendorf J, Vianna CP, Caldas W, Bernardes SR, Trojan LC. Clinical and radiographic success of injection-molded 2-piece zirconia implants submitted to immediate loading: A 12-month report of two cases. Clin Case Rep. 2021;4(12):e05118. https:\/\/doi.org\/10.1002\/ccr3.5118. PMID: 34917363; PMCID: PMC8643492.","journal-title":"Clin Case Rep"},{"key":"7855_CR21","doi-asserted-by":"publisher","unstructured":"da Silva AMP, Horta Dos Santos FA, Mota RF, Teixeira MKS, Telles DM, Louren\u00e7o EJV. Clinical and radiographic outcomes of a two-piece ceramic implant: one year results from a prospective clinical trial. Clin Oral Investig. 2024;18;28(7):380. https:\/\/doi.org\/10.1007\/s00784-024-05783-3. PMID: 38886209.","DOI":"10.1007\/s00784-024-05783-3"},{"issue":"1","key":"7855_CR22","doi-asserted-by":"publisher","first-page":"e13438","DOI":"10.1111\/cid.13438","volume":"27","author":"LRM Nascimento","year":"2025","unstructured":"Nascimento LRM, Silva Resende C, S\u00e1 AF, Francescato O, Dias DR, Lages FS. Anaerobic adhesive effect on the counter-torque of zirconia implant abutment screws: in vitro study. Clin Implant Dent Relat Res. 2025;27(1):e13438. https:\/\/doi.org\/10.1111\/cid.13438.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"3","key":"7855_CR23","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1111\/cid.13210","volume":"25","author":"FTM Lyra","year":"2023","unstructured":"Lyra FTM, Mares CA, S\u00e1 AF, Dias DR, Lages FS. Anaerobic adhesives effect on counter-torque of abutment screws on implants with external hexagon and conical connections: an in vitro study. Clin Implant Dent Relat Res. 2023;25(3):575\u201382. https:\/\/doi.org\/10.1111\/cid.13210.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"4","key":"7855_CR24","doi-asserted-by":"publisher","first-page":"1392","DOI":"10.3390\/ma15041392","volume":"14","author":"AS Vinhas","year":"2022","unstructured":"Vinhas AS, Aroso C, Salazar F, Relvas M, Braga AC, R\u00edos-Carrasco B, Gil J, Rios-Santos JV, Fern\u00e1ndez-Palac\u00edn A, Herrero-Climent M. Vitro study of preload loss in different implant abutment connection designs. Mater (Basel). 2022;14(4):1392. https:\/\/doi.org\/10.3390\/ma15041392. PMID: 35207933; PMCID: PMC8879145.","journal-title":"Mater (Basel)"},{"issue":"3","key":"7855_CR25","doi-asserted-by":"publisher","first-page":"183","DOI":"10.15171\/joddd.2018.028","volume":"12","author":"H Siadat","year":"2018","unstructured":"Siadat H, Najafi H, Alikhasi M, Falahi B, Beyabanaki E, Zayeri F. Effect of lateral oblique Cyclic loading on microleakage and screw loosening of implants with different connections. J Dent Res Dent Clin Dent Prospects. 2018;12(3):183\u20139. https:\/\/doi.org\/10.15171\/joddd.2018.028. Epub 2018 Sep 18. PMID: 30443303; PMCID: PMC6231156.","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"issue":"11","key":"7855_CR26","doi-asserted-by":"publisher","first-page":"e265","DOI":"10.1016\/j.dental.2019.07.026","volume":"35","author":"SR Sammour","year":"2019","unstructured":"Sammour SR, Maamoun El-Sheikh M, Aly El-Gendy A. Effect of implant abutment connection designs, and implant diameters on screw loosening before and after Cyclic loading: In-vitro study. Dent Mater. 2019;35(11):e265\u201371. https:\/\/doi.org\/10.1016\/j.dental.2019.07.026. Epub 2019 Aug 16. PMID: 31427043.","journal-title":"Dent Mater"},{"key":"7855_CR27","doi-asserted-by":"publisher","unstructured":"Nourizadeh A, Ghasemi S, Shafiei E, Bakhtiari F, et al. A comparative study of deformation in hexagonal and star-shaped implant screwdriver heads. BMC Oral Health. 2025;25. https:\/\/doi.org\/10.1186\/s12903-025-06090-3.","DOI":"10.1186\/s12903-025-06090-3"},{"issue":"3","key":"7855_CR28","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1080\/21870764.2019.1642292","volume":"7","author":"S Taruta","year":"2019","unstructured":"Taruta S, Yamaguchi I, Yamakami T, Yamaguchi T. Sintering behavior and mechanical properties of machinable zirconia\/mica composites. J Asian Ceam Soc. 2019;7(3):342\u20139. https:\/\/doi.org\/10.1080\/21870764.2019.1642292.","journal-title":"J Asian Ceam Soc"},{"issue":"4","key":"7855_CR29","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1590\/0103-6440202003643","volume":"4","author":"SA Barbosa Jr","year":"2020","unstructured":"Barbosa SA Jr, Bacchi A, Bar\u00e3o VAR, Silva-Souza YT, Bruniera JF, Caldas RA, Consani RLX. Implant volume Loss, Misfit, screw Loosening, and stress in custom titanium and zirconia abutments. Braz Dent J. 2020;4(4):374\u20139. https:\/\/doi.org\/10.1590\/0103-6440202003643. Erratum in: Braz Dent J. 2020 Sep-Oct.","journal-title":"Braz Dent J"},{"key":"7855_CR30","doi-asserted-by":"publisher","unstructured":"de Carvalho BA, Vedovatto E, de Carvalho PS, Mazaro JV, Falc\u00f3n-Antenucci RM. Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switching. Braz Dent J. 2015;26(3):284-7. https:\/\/doi.org\/10.1590\/0103-6440201300296. PMID: 26200154.","DOI":"10.1590\/0103-6440201300296"},{"issue":"1","key":"7855_CR31","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s40729-020-00229-3","volume":"28","author":"EMN Attiah","year":"2020","unstructured":"Attiah EMN, AlGendy AA, Mostafa TMN. Effect of dynamic Cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study). Int J Implant Dent. 2020;28(1):30. https:\/\/doi.org\/10.1186\/s40729-020-00229-3. PMID: 32720011; PMCID: PMC7385049.","journal-title":"Int J Implant Dent"},{"issue":"1","key":"7855_CR32","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/s40729-018-0121-y","volume":"9","author":"K Tsuruta","year":"2018","unstructured":"Tsuruta K, Ayukawa Y, Matsuzaki T, Kihara M, Koyano K. The influence of implant-abutment connection on the screw loosening and microleakage. Int J Implant Dent. 2018;9(1):11. https:\/\/doi.org\/10.1186\/s40729-018-0121-y. PMID: 29629492; PMCID: PMC5890007.","journal-title":"Int J Implant Dent"},{"issue":"3","key":"7855_CR33","doi-asserted-by":"publisher","first-page":"147","DOI":"10.4103\/2231-0762.158014","volume":"5","author":"A Apratim","year":"2015","unstructured":"Apratim A, Eachempati P, Krishnappa Salian KK, Singh V, Chhabra S, Shah S. Zirconia in dental implantology: A review. J Int Soc Prev Community Dent. 2015;5(3):147\u201356. https:\/\/doi.org\/10.4103\/2231-0762.158014. PMID: 26236672; PMCID: PMC4515795.","journal-title":"J Int Soc Prev Community Dent"},{"key":"7855_CR34","doi-asserted-by":"publisher","unstructured":"Cantarella J, Pitta J, Mojon P, Hicklin SP, Fehmer V, Sailer I. Mechanical Stability of Restorations Supported by Titanium Base, Zirconia, and Polyetherketoneketone Abutments on One- and Two-Piece Zirconia Implants. Int J Oral Maxillofac Implants. 2021;36(2):313\u2013321. https:\/\/doi.org\/10.11607\/jomi.8798. PMID: 33909721.","DOI":"10.11607\/jomi.8798"},{"key":"7855_CR35","doi-asserted-by":"publisher","unstructured":"Foong JK, Judge RB, Palamara JE, Swain MV. Fracture resistance of titanium and zirconia abutments: an in vitro study. J Prosthet Dent. 2013;109(5):304\u2009\u2013\u200912. https:\/\/doi.org\/10.1016\/S0022-3913(13)60306-6. PMID: 23684280.","DOI":"10.1016\/S0022-3913(13)60306-6"},{"key":"7855_CR36","first-page":"110","volume":"6","author":"G Zonfrillo","year":"2008","unstructured":"Zonfrillo G, Pratesi F. Mechanical strength of dental implants. J Appl Biomater Biomech. 2008;6:110\u20138.","journal-title":"J Appl Biomater Biomech"},{"key":"7855_CR37","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.actbio.2015.01.023","volume":"17","author":"E Camposilvan","year":"2015","unstructured":"Camposilvan E, Marro FG, Mestra A, Anglada M. Enhanced reliability of yttria-stabilized zirconia for dental applications. Acta Biomater. 2015;17:36\u201346.","journal-title":"Acta Biomater"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-07855-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-07855-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-07855-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T12:44:55Z","timestamp":1773060295000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-07855-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,5]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["7855"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-07855-0","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,5]]},"assertion":[{"value":"7 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Dhelfeson Willya Douglas-de-Oliveira is an editorial board member of BMC Oral Health. All other authors declare no conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"456"}}