{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T15:12:07Z","timestamp":1774969927845,"version":"3.50.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,2,24]],"date-time":"2026-02-24T00:00:00Z","timestamp":1771891200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T00:00:00Z","timestamp":1774915200000},"content-version":"vor","delay-in-days":35,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Datta Meghe Institute of Higher Education and Research"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"DOI":"10.1186\/s12903-026-07875-w","type":"journal-article","created":{"date-parts":[[2026,2,24]],"date-time":"2026-02-24T13:15:13Z","timestamp":1771938913000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Correlation between insertion torque value and bone density in D3 and D4 bone following photobiomodulation: a randomised interventional study"],"prefix":"10.1186","volume":"26","author":[{"given":"Ashika","family":"Singhania","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anjali Bhoyar","family":"Borle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Surekha","family":"Godbole","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sharayu","family":"Nimonkar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sheetal","family":"Khubchandani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,2,24]]},"reference":[{"key":"7875_CR1","doi-asserted-by":"crossref","unstructured":"Farre-Pages N, Auge-Castro ML, Alaejos-Algarra F, Mareque-Bueno J, Ferres-Padro E, Hernandez-Alfaro F. Relation between bone density and primary implant stability. Medicina Oral Patolog\u00eda Oral y Cirugia Bucal. 2011;e62\u20137.","DOI":"10.4317\/medoral.16.e62"},{"issue":"2","key":"7875_CR2","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.ijom.2015.09.013","volume":"45","author":"M Wada","year":"2016","unstructured":"Wada M, Suganami T, Sogo M, Maeda Y. Can we predict the insertion torque using the bone density around the implant? Int J Oral Maxillofac Surg. 2016;45(2):221\u20135.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"12","key":"7875_CR3","doi-asserted-by":"publisher","first-page":"881","DOI":"10.1111\/j.1365-2842.2006.01692.x","volume":"33","author":"I Turkyilmaz","year":"2006","unstructured":"Turkyilmaz I, T\u00f6z\u00fcm TF, Tumer C, Ozbek EN. Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement. J Oral Rehabil. 2006;33(12):881\u20138.","journal-title":"J Oral Rehabil"},{"issue":"7","key":"7875_CR4","doi-asserted-by":"publisher","first-page":"832","DOI":"10.1111\/j.1600-0501.2011.02203.x","volume":"23","author":"K Isoda","year":"2012","unstructured":"Isoda K, Ayukawa Y, Tsukiyama Y, Sogo M, Matsushita Y, Koyano K. Relationship between the bone density estimated by cone-beam computed tomography and the primary stability of dental implants. Clin Oral Implants Res. 2012;23(7):832\u20136.","journal-title":"Clin Oral Implants Res"},{"issue":"9","key":"7875_CR5","doi-asserted-by":"publisher","first-page":"1016","DOI":"10.1111\/clr.12219","volume":"25","author":"F Salimov","year":"2014","unstructured":"Salimov F, Tatli U, K\u00fcrk\u00e7\u00fc M, Ako\u011flan M, \u00d6ztun\u00e7 H, Kurto\u011flu C. Evaluation of relationship between preoperative bone density values derived from cone beam computed tomography and implant stability parameters: a clinical study. Clin Oral Implants Res. 2014;25(9):1016\u201321.","journal-title":"Clin Oral Implants Res"},{"issue":"4","key":"7875_CR6","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1111\/j.1708-8208.2010.00302.x","volume":"14","author":"M Degidi","year":"2010","unstructured":"Degidi M, Daprile G, Piattelli A. Primary stability determination by means of insertion torque and RFA in a sample of 4,135 implants. Clin Implant Dent Relat Res. 2010;14(4):501\u20137.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"5","key":"7875_CR7","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1034\/j.1600-0501.2003.00932.x","volume":"14","author":"A Beer","year":"2003","unstructured":"Beer A, Gahleitner A, Holm A, Tschabitscher M, Homolka P. Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible. Clin Oral Implants Res. 2003;14(5):616\u201320.","journal-title":"Clin Oral Implants Res"},{"issue":"8","key":"7875_CR8","first-page":"811","volume":"78","author":"Z Mirko Mikic, Vlahovic","year":"2019","unstructured":"Mirko Mikic, Vlahovic Z, Dragoslav Nenezic G, Videnovic, Ilic D, Mladenovic R. The correlation of CBCT analysis derived bone density parameters with primary implant stability - a clinical study. Vojnosanit Pregl. 2019;78(8):811\u20137.","journal-title":"Vojnosanit Pregl"},{"issue":"3","key":"7875_CR9","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.3390\/tomography8030107","volume":"8","author":"M Mikic","year":"2022","unstructured":"Mikic M, Vlahovic Z, Stevanovi\u0107 M, Arsic Z, Mladenovic R. The importance of correlation between CBCT analysis of bone density and primary stability when choosing the design of dental Implants\u2014Ex vivo study. Tomography. 2022;8(3):1293\u2013306.","journal-title":"Tomography"},{"issue":"1","key":"7875_CR10","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1111\/cid.12565","volume":"20","author":"FS Lages","year":"2018","unstructured":"Lages FS, Douglas-de Oliveira DW, Costa FO. Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: A systematic review. Clin Implant Dent Relat Res. 2018;20(1):26\u201333.","journal-title":"Clin Implant Dent Relat Res"},{"issue":"1","key":"7875_CR11","doi-asserted-by":"publisher","first-page":"30","DOI":"10.5051\/jpis.2013.43.1.30","volume":"43","author":"D Bayarchimeg","year":"2013","unstructured":"Bayarchimeg D, Namgoong H, Kim BK, Kim MD, Kim S, Kim TI, et al. Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test. J Periodontal Implant Sci. 2013;43(1):30.","journal-title":"J Periodontal Implant Sci"},{"issue":"6","key":"7875_CR12","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1515\/bmt-2020-0039","volume":"65","author":"T Grobecker-Karl","year":"2020","unstructured":"Grobecker-Karl T, Karl M, Steiner C. Insertion torque\/time integral as a measure of primary implant stability. Biomed Eng Biomed Tech. 2020;65(6):729\u201333.","journal-title":"Biomed Eng Biomed Tech"},{"issue":"4","key":"7875_CR13","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1016\/j.prosdent.2014.02.011","volume":"112","author":"M Herekar","year":"2014","unstructured":"Herekar M, Sethi M, Ahmad T, Fernandes AS, Patil V, Kulkarni H. A correlation between bone (B), insertion torque (IT), and implant stability (S): BITS score. J Prosthet Dent. 2014;112(4):805\u201310.","journal-title":"J Prosthet Dent"},{"key":"7875_CR14","doi-asserted-by":"crossref","unstructured":"Singhania A, Bhoyar A, Dubey SA, Jaiswal T. Effect of photobiomodulation on crestal bone density around dental implants: a case report. Cureus. 2024;16(6):e63546","DOI":"10.7759\/cureus.63546"},{"key":"7875_CR15","doi-asserted-by":"crossref","unstructured":"Singhania A, Borle AB, Sathe S. Efficacy of three different photobiomodulation therapies on primary and secondary implant stability in D3 and D4 bone Type- A research protocol for randomised controlled trial. J Clin Diagn Res. 2023;17(1):ZK01-ZK03.","DOI":"10.7860\/JCDR\/2023\/59042.17297"},{"issue":"6","key":"7875_CR16","first-page":"262","volume":"43","author":"E Tang","year":"2013","unstructured":"Tang E, Arany P. Photobiomodulation and implants: implications for dentistry. JPIS. 2013;43(6):262.","journal-title":"JPIS"},{"issue":"2","key":"7875_CR17","doi-asserted-by":"publisher","first-page":"80","DOI":"10.4103\/sjmms.sjmms_410_19","volume":"8","author":"SM Zayed","year":"2020","unstructured":"Zayed SM, Hakim AAA. Clinical efficacy of photobiomodulation on dental implant osseointegration: A systematic review. Saudi J Med Med Sci. 2020;8(2):80\u20136.","journal-title":"Saudi J Med Med Sci"},{"key":"7875_CR18","doi-asserted-by":"crossref","unstructured":"Shenoy A, Ganapathy D, Subhabrata M. Effectiveness of Photobiomodulation With Low-Level Laser Therapy on the Implant Stability Quotient at Different Time Intervals: A Randomized Clinical Trial. Cur\u0113us. 2024.","DOI":"10.7759\/cureus.52160"},{"issue":"2","key":"7875_CR19","doi-asserted-by":"publisher","first-page":"124","DOI":"10.4103\/0972-4052.176539","volume":"16","author":"V Swami","year":"2016","unstructured":"Swami V, Vijayaraghavan V, Swami V. Current trends to measure implant stability. J Indian Prosthodont Soc. 2016;16(2):124.","journal-title":"J Indian Prosthodont Soc"},{"key":"7875_CR20","doi-asserted-by":"crossref","unstructured":"Kazazoglu E. An overview of implant stability Measurement. Mod approaches Dent oral health care [Internet]. 2018 Jul 13 [cited 2025 May 19];2(5).","DOI":"10.32474\/MADOHC.2018.02.000149"},{"issue":"11","key":"7875_CR21","doi-asserted-by":"publisher","first-page":"2605","DOI":"10.3390\/ma13112605","volume":"13","author":"M Takechi","year":"2020","unstructured":"Takechi M, Ishioka Y, Ninomiya Y, Ono S, Tada M, Nakagawa T, et al. Morphological evaluation of bone by CT to determine primary Stability\u2014Clinical study. Materials. 2020;13(11):2605.","journal-title":"Materials"},{"issue":"2","key":"7875_CR22","first-page":"118","volume":"4","author":"L Tomer","year":"2016","unstructured":"Tomer L, Rao OS, Reddy EH, Vushkamalla S, Santosh TS, Reddy ML. Evaluation of osseointegration by correlating insertion Torque, implant Stability, and bone density of implant site: an in vivo study. Int J Oral Care Res. 2016;4(2):118\u201321.","journal-title":"Int J Oral Care Res"},{"key":"7875_CR23","doi-asserted-by":"crossref","unstructured":"Park KJ, Kwon JY. Kimsk,. Heosj,. Koakjy,. Leejh, et al. The relationship between implant stability quotient values and implant insertion variables: a clinical study. J Rehabil. 2011;39(2):151\u20139.","DOI":"10.1111\/j.1365-2842.2011.02255.x"},{"key":"7875_CR24","doi-asserted-by":"crossref","unstructured":"Matys J, \u015awider K, Grzech-Le\u015bniak K, Dominiak M, Romeo U. Photobiomodulation by a 635nm diode laser on Peri-Implant bone: primary and secondary stability and bone density Analysis\u2014A randomized clinical trial. Biomed Res Int. 2019;1\u20138.","DOI":"10.1155\/2019\/2785302"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-07875-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-07875-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-07875-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T13:41:48Z","timestamp":1774964508000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-07875-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,24]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["7875"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-07875-w","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,24]]},"assertion":[{"value":"7 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval obtained with Institutional Ethics Committee, Datta Meghe Institute of Higher Education and research (DMIHER) with IEC number as DMIMS(DU)\/IEC\/2021\/628 and informed consent taken from patient. Declaration of Helsinki: The study was conducted in accordance with Declaration of Helsinki, an ethics committee approved the protocol and informed consent was obtained from patients.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"561"}}