{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T14:31:10Z","timestamp":1791815470865,"version":"4.3.4"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T00:00:00Z","timestamp":1773187200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"vor","delay-in-days":29,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002352","name":"Ain Shams University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100002352","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>There is a lack of comprehensive comparative data assessing the accuracy of multiple intraoral scanners (IOSs) across both partially and completely edentulous cases, particularly in the presence of variable implant positions. The aim of this study was to assess the effect of IOSs and implant positions in 4-unit and All-on-4 restorations on the trueness and precision of digital impressions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Two maxillary resin models were fabricated: a partially edentulous arch planned for a 4-unit fixed dental prosthesis (FDP) with implants at the canine and first molar sites, and a completely edentulous arch for an All-on-4 FDP. Each model was scanned (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200910 each) using five IOSs: Omnicam AF, CS 3800, Trios 3\u00a0A, Medit i500, and Primescan AC. Scan data were analyzed using Geomagic Control X to assess trueness and precision. Statistical analysis was performed using three-way ANOVA, followed by two-way ANOVA and post hoc testing (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Regarding trueness in the 4-unit FDP group, CS3800 exhibited the highest RMS in anterior and posterior implants. In the All-on-4 group, Trios and Medit i500 showed the lowest RMS in anterior implants, and Medit i500 showed the lowest RMS in posterior implants. CS3800 showed the highest RMS in both the implant positions. Regarding precision in the 4-unit FDP group, Trios and Primescan achieved the lowest RMS. CS3800 and Medit i500 showed the highest RMS in posterior implants. In All-on-4, Omnicam showed the least RMS in anterior implants, while Primescan the least in posterior implants. All scanners showed less precision in posterior implants in both models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Under controlled in vitro conditions, differences in trueness and precision were observed among intraoral scanners, depending on implant position and restoration type. In All-on-4 restorations, Medit i500 showed the highest trueness. Whereas, in 4-unit FDPs, Trios 3 and Primescan exhibited the highest precision. Anterior and posterior implant positions exhibited varying levels of trueness and precision deviation across scanners.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical significance<\/jats:title>\n                    <jats:p>Intraoral scanner accuracy is influenced by implant position and prosthesis configuration, with posterior implant positions generally exhibiting reduced precision under in vitro conditions. These findings represent statistically significant differences observed within an experimental model and do not establish scanner ranking, clinical acceptability thresholds, or in vivo scanner suitability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Graphical Abstract<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-026-07887-6","type":"journal-article","created":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T08:04:11Z","timestamp":1773216251000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Accuracy of digital impressions for implant fixed dental prostheses in partial and complete maxillary edentulous arches: effect of intraoral scanners and implant position"],"prefix":"10.1186","volume":"26","author":[{"given":"Marwa","family":"Emam","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mostafa","family":"Aldesoki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Bourauel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,11]]},"reference":[{"key":"7887_CR1","doi-asserted-by":"publisher","first-page":"103476","DOI":"10.1016\/j.jdent.2020.103476","volume":"102","author":"Y Pan","year":"2020","unstructured":"Pan Y, Tam JMY, Tsoi JKH, Lam WYH, Huang R, Chen Z, Pow EHN. Evaluation of laboratory scanner accuracy by a novel calibration block for complete-arch implant rehabilitation. J Dent. 2020;102:103476. https:\/\/doi.org\/10.1016\/j.jdent.2020.103476.","journal-title":"J Dent"},{"key":"7887_CR2","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1111\/jopr.12527","volume":"27","author":"P Ahlholm","year":"2018","unstructured":"Ahlholm P, Sipil\u00e4 K, Vallittu P, Jakonen M, Kotiranta U. Digital versus conventional impressions in fixed prosthodontics: A review. J Prosthodont. 2018;27:35\u201341. https:\/\/doi.org\/10.1111\/jopr.12527.","journal-title":"J Prosthodont"},{"key":"7887_CR3","doi-asserted-by":"publisher","first-page":"577","DOI":"10.17219\/dmp\/162573","volume":"61","author":"M Emam","year":"2023","unstructured":"Emam M, Ghanem L, Sadek H. Effect of different intraoral scanners and post-space depths on the trueness of digital impressions. Dent Med Probl. 2023;61:577\u201384. https:\/\/doi.org\/10.17219\/dmp\/162573.","journal-title":"Dent Med Probl"},{"key":"7887_CR4","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1186\/s12903-017-0415-0","volume":"17","author":"T Joda","year":"2017","unstructured":"Joda T, Zarone F, Ferrari M. The complete digital workflow in fixed prosthodontics: a systematic review. BMC Oral Health. 2017;17:124. https:\/\/doi.org\/10.1186\/s12903-017-0415-0.","journal-title":"BMC Oral Health"},{"key":"7887_CR5","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1186\/s12903-017-0442-x","volume":"17","author":"F Mangano","year":"2017","unstructured":"Mangano F, Gandolfi A, Luongo G, Logozzo S. Intraoral scanners in dentistry: a review of the current literature. BMC Oral Health. 2017;17:149. https:\/\/doi.org\/10.1186\/s12903-017-0442-x.","journal-title":"BMC Oral Health"},{"key":"7887_CR6","doi-asserted-by":"publisher","DOI":"10.3390\/dj9070075","author":"AB Nulty","year":"2021","unstructured":"Nulty AB. A comparison of full arch trueness and precision of nine intra-oral digital scanners and four lab digital scanners. Dent J (Basel). 2021. https:\/\/doi.org\/10.3390\/dj9070075.","journal-title":"Dent J (Basel)"},{"key":"7887_CR7","doi-asserted-by":"publisher","DOI":"10.3390\/jpm13050832","author":"N Drancourt","year":"2023","unstructured":"Drancourt N, Auduc C, Mouget A, Mouminoux J, Auroy P, Veyrune JL, El Osta N, Nicolas E. Accuracy of conventional and digital impressions for Full-Arch Implant-Supported prostheses: an in vitro study. J Pers Med. 2023. https:\/\/doi.org\/10.3390\/jpm13050832.","journal-title":"J Pers Med"},{"key":"7887_CR8","doi-asserted-by":"publisher","first-page":"e0163107","DOI":"10.1371\/journal.pone.0163107","volume":"11","author":"FG Mangano","year":"2016","unstructured":"Mangano FG, Veronesi G, Hauschild U, Mijiritsk E, Mangano C. Trueness and precision of four intraoral scanners in oral implantology: A comparative in vitro study. PLoS ONE. 2016;11:e0163107. https:\/\/doi.org\/10.1371\/journal.pone.0163107.","journal-title":"PLoS ONE"},{"key":"7887_CR9","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.1007\/s00784-015-1626-x","volume":"20","author":"JF G\u00fcth","year":"2016","unstructured":"G\u00fcth JF, Edelhoff D, Schweiger J, Keul C. A new method for the evaluation of the accuracy of full-arch digital impressions in vitro. Clin Oral Investig. 2016;20:1487\u201394. https:\/\/doi.org\/10.1007\/s00784-015-1626-x.","journal-title":"Clin Oral Investig"},{"key":"7887_CR10","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1093\/ejo\/cjv077","volume":"38","author":"C Goracci","year":"2016","unstructured":"Goracci C, Franchi L, Vichi A, Ferrari M. Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: a systematic review of the clinical evidence. Eur J Orthod. 2016;38:422\u20138. https:\/\/doi.org\/10.1093\/ejo\/cjv077.","journal-title":"Eur J Orthod"},{"key":"7887_CR11","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1007\/s00784-021-04213-y","volume":"26","author":"GSY Gon\u00e7alves","year":"2022","unstructured":"Gon\u00e7alves GSY, de Magalh\u00e3es KMF, Rocha EP, dos Santos PH, Assun\u00e7\u00e3o WG. Oral health-related quality of life and satisfaction in edentulous patients rehabilitated with implant-supported full dentures all-on-four concept: a systematic review. Clin Oral Investig. 2022;26:83\u201394. https:\/\/doi.org\/10.1007\/s00784-021-04213-y.","journal-title":"Clin Oral Investig"},{"key":"7887_CR12","doi-asserted-by":"publisher","first-page":"s88","DOI":"10.1111\/j.1708-8208.2005.tb00080.x","volume":"7","author":"P Mal\u00f3","year":"2005","unstructured":"Mal\u00f3 P, Rangert B, Nobre M. All-on-4 immediate-function concept with Br\u00e5nemark System\u00ae implants for completely edentulous maxillae: A 1-year retrospective clinical study. Clin Implant Dent Relat Res. 2005;7:s88\u201394. https:\/\/doi.org\/10.1111\/j.1708-8208.2005.tb00080.x.","journal-title":"Clin Implant Dent Relat Res"},{"key":"7887_CR13","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1111\/cid.12771","volume":"21","author":"P Mal\u00f3","year":"2019","unstructured":"Mal\u00f3 P, de Ara\u00fajo Nobre M, Lopes A, Ferro A, Nunes M. The All-on-4 concept for full-arch rehabilitation of the edentulous maxillae: A longitudinal study with 5\u201313 years of follow-up. Clin Implant Dent Relat Res. 2019;21:538\u201349. https:\/\/doi.org\/10.1111\/cid.12771.","journal-title":"Clin Implant Dent Relat Res"},{"key":"7887_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13104-025-07235-x","volume":"18","author":"HM El-Refay","year":"2025","unstructured":"El-Refay HM, Abdelaziz MS, Cheta NM, Abdallah MF. The accuracy of digital impression with different intraoral scanners on maxillary all on four implants: an in vitro study. BMC Res Notes. 2025;18:1\u201310. https:\/\/doi.org\/10.1186\/s13104-025-07235-x.","journal-title":"BMC Res Notes"},{"key":"7887_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12903-022-02505-7","volume":"22","author":"MM Dohiem","year":"2022","unstructured":"Dohiem MM, Abdelaziz MS, Abdalla MF, Fawzy AM. Digital assessment of the accuracy of implant impression techniques in free end saddle partially edentulous patients. A controlled clinical trial. BMC Oral Health. 2022;22:1\u20139. https:\/\/doi.org\/10.1186\/s12903-022-02505-7.","journal-title":"BMC Oral Health"},{"key":"7887_CR16","doi-asserted-by":"publisher","first-page":"4612","DOI":"10.3390\/app11104612","volume":"11","author":"K Seo","year":"2021","unstructured":"Seo K, Kim S. A new method to evaluate trueness and precision of digital and conventional impression techniques for complete dental arch. Appl Sci. 2021;11:4612. https:\/\/doi.org\/10.3390\/app11104612.","journal-title":"Appl Sci"},{"key":"7887_CR17","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1111\/clr.13715","volume":"32","author":"A Schmidt","year":"2021","unstructured":"Schmidt A, Rein PE, W\u00f6stmann B, Schlenz MA. A comparative clinical study on the transfer accuracy of conventional and digital implant impressions using a new reference key-based method. Clin Oral Implants Res. 2021;32:460\u20139. https:\/\/doi.org\/10.1111\/clr.13715.","journal-title":"Clin Oral Implants Res"},{"key":"7887_CR18","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1186\/s12903-019-0792-7","volume":"19","author":"FG Mangano","year":"2019","unstructured":"Mangano FG, Hauschild U, Veronesi G, Imburgia M, Mangano C, Admakin O. Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study. BMC Oral Health. 2019;19:101. https:\/\/doi.org\/10.1186\/s12903-019-0792-7.","journal-title":"BMC Oral Health"},{"key":"7887_CR19","doi-asserted-by":"publisher","first-page":"105782","DOI":"10.1016\/j.jdent.2025.105782","volume":"159","author":"F Grande","year":"2025","unstructured":"Grande F, Balma AM, Mussano F, Catapano S. Effect of implant scan body type, intraoral scanner and scan strategy on the accuracy and scanning time of a maxillary complete arch implant scans: an in vitro study. J Dent. 2025;159:105782. https:\/\/doi.org\/10.1016\/j.jdent.2025.105782.","journal-title":"J Dent"},{"key":"7887_CR20","doi-asserted-by":"publisher","unstructured":"Carneiro Pereira AL, Souza Curinga MR, Melo Segundo HV, da, Fonte Porto Carreiro A. Factors that influence the accuracy of intraoral scanning of total edentulous arches rehabilitated with multiple implants: A systematic review. J Prosthet Dent 129 (2023) 855\u2013862. https:\/\/doi.org\/10.1016\/j.prosdent.2021.09.001","DOI":"10.1016\/j.prosdent.2021.09.001"},{"key":"7887_CR21","doi-asserted-by":"publisher","first-page":"1430","DOI":"10.1016\/j.prosdent.2024.11.016","volume":"133","author":"F Grande","year":"2025","unstructured":"Grande F, Pavone L, Molinelli F, Mussano F, Srinivasan M, Catapano S. CAD-CAM complete digital dentures: an improved clinical and laboratory workflow. J Prosthet Dent. 2025;133:1430\u20135. https:\/\/doi.org\/10.1016\/j.prosdent.2024.11.016.","journal-title":"J Prosthet Dent"},{"key":"7887_CR22","doi-asserted-by":"publisher","first-page":"175","DOI":"10.3758\/bf03193146","volume":"39","author":"F Faul","year":"2007","unstructured":"Faul F, Erdfelder E, Lang AG, Buchner A. G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39:175\u201391. https:\/\/doi.org\/10.3758\/bf03193146.","journal-title":"Behav Res Methods"},{"key":"7887_CR23","doi-asserted-by":"publisher","first-page":"104414","DOI":"10.1016\/j.jdent.2023.104414","volume":"130","author":"BB Yatmaz","year":"2023","unstructured":"Yatmaz BB, Raith S, Reich S. Accuracy of four recent intraoral scanners with respect to two different ceramic surfaces. J Dent. 2023;130:104414. https:\/\/doi.org\/10.1016\/j.jdent.2023.104414.","journal-title":"J Dent"},{"key":"7887_CR24","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1186\/s12903-017-0383-4","volume":"17","author":"M Imburgia","year":"2017","unstructured":"Imburgia M, Logozzo S, Hauschild U, Veronesi G, Mangano C, Mangano FG. Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study. BMC Oral Health. 2017;17:92. https:\/\/doi.org\/10.1186\/s12903-017-0383-4.","journal-title":"BMC Oral Health"},{"key":"7887_CR25","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1186\/s12903-022-02505-7","volume":"22","author":"MM Dohiem","year":"2022","unstructured":"Dohiem MM, Abdelaziz MS, Abdalla MF, Fawzy AM. Digital assessment of the accuracy of implant impression techniques in free end saddle partially edentulous patients. A controlled clinical trial. BMC Oral Health. 2022;22:486. https:\/\/doi.org\/10.1186\/s12903-022-02505-7.","journal-title":"BMC Oral Health"},{"key":"7887_CR26","unstructured":"R: The R Project for Statistical Computing. https:\/\/www.r-project.org\/. Accessed 19 Jul 2025."},{"key":"7887_CR27","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1016\/j.prosdent.2017.07.002","volume":"119","author":"A Marghalani","year":"2018","unstructured":"Marghalani A, Weber HP, Finkelman M, Kudara Y, El Rafie K, Papaspyridakos P. Digital versus conventional implant impressions for partially edentulous arches: an evaluation of accuracy. J Prosthet Dent. 2018;119:574\u20139. https:\/\/doi.org\/10.1016\/j.prosdent.2017.07.002.","journal-title":"J Prosthet Dent"},{"key":"7887_CR28","doi-asserted-by":"publisher","first-page":"1489","DOI":"10.3390\/app11041489","volume":"11","author":"Y-C Lee","year":"2021","unstructured":"Lee Y-C, Kim J-E, Nam N-E, Shin S-H, Lim J-H, Lee K-W, Shim J-S. Influence of edentulous conditions on intraoral scanning accuracy of virtual interocclusal record in quadrant scan. Appl Sci. 2021;11:1489. https:\/\/doi.org\/10.3390\/app11041489.","journal-title":"Appl Sci"},{"key":"7887_CR29","doi-asserted-by":"publisher","first-page":"104122","DOI":"10.1016\/j.jdent.2022.104122","volume":"121","author":"M G\u00f3mez-Polo","year":"2022","unstructured":"G\u00f3mez-Polo M, \u00c1lvarez F, Ortega R, G\u00f3mez-Polo C, Barmak AB, Kois JC, Revilla-Le\u00f3n M. Influence of the implant scan body Bevel location, implant angulation and position on intraoral scanning accuracy: an in vitro study. J Dent. 2022;121:104122. https:\/\/doi.org\/10.1016\/j.jdent.2022.104122.","journal-title":"J Dent"},{"key":"7887_CR30","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1016\/j.jpor.2019.06.001","volume":"64","author":"L Arcuri","year":"2020","unstructured":"Arcuri L, Pozzi A, Lio F, Rompen E, Zechner W, Nardi A. Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trial. J Prosthodont Res. 2020;64:128\u201336. https:\/\/doi.org\/10.1016\/j.jpor.2019.06.001.","journal-title":"J Prosthodont Res"},{"key":"7887_CR31","doi-asserted-by":"publisher","first-page":"102","DOI":"10.11607\/jomi.3592","volume":"30","author":"W-S Lin","year":"2015","unstructured":"Lin W-S, Harris B, Elathamna E, Abdel-Azim T, Morton D. Effect of implant divergence on the accuracy of definitive casts created from traditional and digital implant-level impressions: an in vitro comparative study. Int J Oral Maxillofac Implants. 2015;30:102\u20139. https:\/\/doi.org\/10.11607\/jomi.3592.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"7887_CR32","doi-asserted-by":"publisher","first-page":"3761750","DOI":"10.1155\/2018\/3761750","volume":"2018","author":"M Alikhasi","year":"2018","unstructured":"Alikhasi M, Siadat H, Nasirpour A, Hasanzade M. Three-Dimensional accuracy of digital impression versus conventional method: effect of implant angulation and connection type. Int J Dent. 2018;2018:3761750. https:\/\/doi.org\/10.1155\/2018\/3761750.","journal-title":"Int J Dent"},{"key":"7887_CR33","doi-asserted-by":"publisher","first-page":"e43312","DOI":"10.1371\/journal.pone.0043312","volume":"7","author":"WJ van der Meer","year":"2012","unstructured":"van der Meer WJ, Andriessen FS, Wismeijer D, Ren Y. Application of intra-oral dental scanners in the digital workflow of implantology. PLoS ONE. 2012;7:e43312. https:\/\/doi.org\/10.1371\/journal.pone.0043312.","journal-title":"PLoS ONE"},{"key":"7887_CR34","doi-asserted-by":"publisher","unstructured":"Alfaraj A, Khanlar LN, Lin W-S, Zandinejad A. Exploring the impact of the extent of the partially edentulous area on the accuracy of two intraoral scanners. J Prosthet Dent. 2024;131. https:\/\/doi.org\/10.1016\/j.prosdent.2023.10.002. 163.e1-163.e8.","DOI":"10.1016\/j.prosdent.2023.10.002"},{"key":"7887_CR35","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1016\/j.jpor.2016.09.002","volume":"61","author":"F Mandelli","year":"2017","unstructured":"Mandelli F, Gherlone E, Gastaldi G, Ferrari M. Evaluation of the accuracy of extraoral laboratory scanners with a single-tooth abutment model: A 3D analysis. J Prosthodont Res. 2017;61:363\u201370. https:\/\/doi.org\/10.1016\/j.jpor.2016.09.002.","journal-title":"J Prosthodont Res"},{"key":"7887_CR36","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1111\/clr.13548","volume":"31","author":"K Miyoshi","year":"2020","unstructured":"Miyoshi K, Tanaka S, Yokoyama S, Sanda M, Baba K. Effects of different types of intraoral scanners and scanning ranges on the precision of digital implant impressions in edentulous maxilla: an in vitro study. Clin Oral Implants Res. 2020;31:74\u201383. https:\/\/doi.org\/10.1111\/clr.13548.","journal-title":"Clin Oral Implants Res"},{"key":"7887_CR37","doi-asserted-by":"publisher","first-page":"388","DOI":"10.4047\/jap.2022.14.6.388","volume":"14","author":"G Kaya","year":"2022","unstructured":"Kaya G, Bilmenoglu C. Accuracy of 14 intraoral scanners for the All-on-4 treatment concept: a comparative in vitro study. J Adv Prosthodont. 2022;14:388\u201398. https:\/\/doi.org\/10.4047\/jap.2022.14.6.388.","journal-title":"J Adv Prosthodont"},{"key":"7887_CR38","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1186\/s40729-021-00352-9","volume":"27","author":"M Sanda","year":"2021","unstructured":"Sanda M, Miyoshi K, Baba K. Trueness and precision of digital implant impressions by intraoral scanners: a literature review. Int J Implant Dentistry. 2021;27:97. https:\/\/doi.org\/10.1186\/s40729-021-00352-9.","journal-title":"Int J Implant Dentistry"},{"key":"7887_CR39","doi-asserted-by":"publisher","first-page":"104636","DOI":"10.1016\/j.jdent.2023.104636","volume":"137","author":"V Vitai","year":"2023","unstructured":"Vitai V, N\u00e9meth A, S\u00f3lyom E, Czumbel LM, Szab\u00f3 B, Fazekas R, Gerber G, Hegyi P, Hermann P, Borb\u00e9ly J. Evaluation of the accuracy of intraoral scanners for complete-arch scanning: A systematic review and network meta-analysis. J Dent. 2023;137:104636. https:\/\/doi.org\/10.1016\/j.jdent.2023.104636.","journal-title":"J Dent"},{"key":"7887_CR40","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12903-018-0489-3","volume":"18","author":"R Nedelcu","year":"2018","unstructured":"Nedelcu R, Olsson P, Nystr\u00f6m I, Thor A. Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: an in vitro descriptive comparison. BMC Oral Health. 2018;18:1\u201311. https:\/\/doi.org\/10.1186\/s12903-018-0489-3.","journal-title":"BMC Oral Health"},{"key":"7887_CR41","doi-asserted-by":"publisher","first-page":"105558","DOI":"10.1016\/j.jdent.2025.105558","volume":"153","author":"MB D\u00f6nmez","year":"2025","unstructured":"D\u00f6nmez MB, \u00c7akmak G, Schimmel M, Bayadse M, Yilmaz B, Abou-Ayash S. Scan accuracy of recently introduced wireless intraoral scanners in different fixed partial denture situations. J Dent. 2025;153:105558. https:\/\/doi.org\/10.1016\/j.jdent.2025.105558.","journal-title":"J Dent"},{"key":"7887_CR42","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/j.prosdent.2015.09.011","volume":"115","author":"A Ender","year":"2016","unstructured":"Ender A, Attin T, Mehl A. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. J Prosthet Dent. 2016;115:313\u201320. https:\/\/doi.org\/10.1016\/j.prosdent.2015.09.011.","journal-title":"J Prosthet Dent"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-07887-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-07887-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-07887-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T07:16:13Z","timestamp":1775718973000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-07887-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,11]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["7887"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-07887-6","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,11]]},"assertion":[{"value":"5 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval number (FDASU-RecER062517) was obtained from the Institutional Research Ethical Committee (FDASU-REC). The study followed the principles of the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participant"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"610"}}