{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T21:52:13Z","timestamp":1781646733887,"version":"3.54.5"},"reference-count":44,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T00:00:00Z","timestamp":1774569600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"vor","delay-in-days":13,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100019652","name":"British University in Egypt","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100019652","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>A lot of studies have demonstrated the increased hardness of the reinforced maxillary dentures. However, the amount of stress induced by different reinforcement materials under the reinforcement dentures and their effect on the underlying supporting tissues and on the deformation of the denture bases were questionable. This study was conducted to compare the stresses induced within the supporting oral tissues from maxillary denture bases reinforced with computer-aided designing\/computer-aided manufacturing CAD\/CAM zirconia framework or cobalt chrome (Co-Cr) framework, and to detect the deformation that occurred to these bases.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>Twenty-six maxillary complete dentures were fabricated and divided into two groups (n\u2009=\u200913). Group A (test group): zirconia framework reinforcement. Group B (control group): Co-Cr framework reinforcement. All denture bases were subjected to unilateral static loading, and then the strain was monitored using a strain gauge analysis device. Then the reinforced denture bases of both groups were subjected to dynamic cyclic loading, then deformation was detected using Geomagic software.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Group A; showed significantly higher strain measured at all measuring areas compared to Group B. The maximum principal strain (MPS) at the 1st right molar area was consistently the highest among all measuring areas, regardless of the denture reinforcement framework type. Deformation results suggested that Group A; showed statistically significant reduced deformation compared to Group B after dynamic cyclic load application.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Zirconia framework-reinforced maxillary dentures were associated with higher strains and less framework deformation than cobalt chrome framework-reinforced maxillary dentures when static and dynamic loading were applied.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-026-08069-0","type":"journal-article","created":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T01:25:14Z","timestamp":1774574714000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Strain gauge analysis and deformation detection of maxillary denture bases reinforced by CAD\/CAM milled zirconia and cobalt chromium (Co-Cr) frameworks: An in-vitro study"],"prefix":"10.1186","volume":"26","author":[{"given":"Maha Nagy Mohamed","family":"Kamal","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ghada Mahmoud Mansour","family":"ElGindy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hebatallah Tarek","family":"Mohamed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marwa Ezzat","family":"Sabet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,27]]},"reference":[{"key":"8069_CR1","first-page":"71","volume":"7","author":"HM Murthy","year":"2015","unstructured":"Murthy HM, Shaik S, Sachdeva H, Khare S, Haralur SB, Roopa KT. Effect of reinforcement using stainless steel mesh, glass fibers, and polyethylene on the impact strength of heat cure denture base resin-an in vitro study. J Int Oral Health. 2015;7:71\u20139.","journal-title":"J Int Oral Health"},{"key":"8069_CR2","doi-asserted-by":"publisher","first-page":"43","DOI":"10.4236\/jbise.2023.163003","volume":"16","author":"A Prombonas","year":"2023","unstructured":"Prombonas A, Sklavou E, Ioannidou A, Kosma E, Orfanou K. An alternative method for incorporating fiber meshes in complete upper dentures. J Biomedical Sci Eng. 2023;16:43\u201352.","journal-title":"J Biomedical Sci Eng"},{"key":"8069_CR3","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1016\/j.prosdent.2003.09.008","volume":"90","author":"G Zappini","year":"2003","unstructured":"Zappini G, Kammann A, Wachter W. Comparison of fracture tests of denture base materials. J Prosthet Dent. 2003;90:578\u201385.","journal-title":"J Prosthet Dent"},{"key":"8069_CR4","doi-asserted-by":"publisher","first-page":"7","DOI":"10.5368\/aedj.2011.3.4.1.2","volume":"4","author":"H Prasad","year":"2011","unstructured":"Prasad H, Kalavathy M, Mohammed S. Effect of glass fiber and silane treated glass fiber reinforcement on impact strength of maxillary complete denture. Annals Essences Dent. 2011;4:7\u201312.","journal-title":"Annals Essences Dent"},{"key":"8069_CR5","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1016\/S0022-3913(03)00518-3","volume":"90","author":"O Karacaer","year":"2003","unstructured":"Karacaer O, Polat TN, Tezvergil A, Lassila LVJ, Vallittu PK. The effect of length and concentration of glass fibers on the mechanical properties of an injection- and compression- molded denture base polymer. J Prosthet Dent. 2003;90:385.","journal-title":"J Prosthet Dent"},{"key":"8069_CR6","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/j.dental.2004.07.002","volume":"21","author":"P Franklin","year":"2005","unstructured":"Franklin P, Wood DJ, Bubb NL. Reinforcement of polymethyl methacrylate denture base with glass flake. Dent Mat. 2005;21:365\u201370.","journal-title":"Dent Mat"},{"key":"8069_CR7","doi-asserted-by":"publisher","first-page":"555","DOI":"10.2186\/jjps.52.555","volume":"52","author":"A Ratnasari","year":"2008","unstructured":"Ratnasari A, Hasegawa K, Yoshihara K, Nagaoka N, Kokeguchi S, Nishigawa G, et al. Deformation of mesh type stainless palatal plate of maxillary complete denture and the growth of microorganisms. J Jpn Prosthodont Soc. 2008;52:555\u20138.","journal-title":"J Jpn Prosthodont Soc"},{"key":"8069_CR8","doi-asserted-by":"publisher","first-page":"22","DOI":"10.4047\/jap.2017.9.1.22","volume":"9","author":"SM Im","year":"2017","unstructured":"Im SM, Huh YH, Cho LR, Park CJ. Comparison of the fracture resistances of glass fiber mesh-and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading. J Adv Prosthodont. 2017;9:22\u201330.","journal-title":"J Adv Prosthodont"},{"key":"8069_CR9","first-page":"55","volume":"11","author":"DI Elsebai","year":"2023","unstructured":"Elsebai DI, Eid HI, Osama AM, Mohamed HT. Effect of CAD\/CAM constructed biohpp versus zirconia frameworks reinforced maxillary complete denture on fracture resistance (In vitro Study). J Med Sci. 2023;11:55\u201360.","journal-title":"J Med Sci"},{"key":"8069_CR10","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1016\/j.prosdent.2016.08.017","volume":"117","author":"MT Kattadiyil","year":"2017","unstructured":"Kattadiyil MT, Alhelal A. An update on computer-engineered complete dentures: a systematic review on clinical outcomes. J Prosthet Dent. 2017;117:478\u201385.","journal-title":"J Prosthet Dent"},{"key":"8069_CR11","doi-asserted-by":"publisher","first-page":"116","DOI":"10.11607\/ijp.5031","volume":"30","author":"PA Steinmassl","year":"2017","unstructured":"Steinmassl PA, Klaunzer F, Steinmassl O, Dumfahrt H, Grunert I. Evaluation of currently available CAD\/CAM denture systems. Int J Prosthodont. 2017;30:116\u201322.","journal-title":"Int J Prosthodont"},{"key":"8069_CR12","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1016\/j.prosdent.2016.03.022","volume":"116","author":"FS Schwindling","year":"2016","unstructured":"Schwindling FS, Stober T. A Comparison of two digital techniques for the fabrication of complete removable dental prostheses: a pilot clinical study. J Prosthet Dent. 2016;116:756\u201363.","journal-title":"J Prosthet Dent"},{"key":"8069_CR13","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1186\/s40729-022-00454-y","volume":"14","author":"I Assoratgoon","year":"2022","unstructured":"Assoratgoon I, Yoda N, Iwamoto M, Sato T, Kawata T, Egusa H, Sasaki K. In vivo measurement of three-dimensional load exerted on dental implants: a literature review. Int J Implant Dent. 2022;14:8:52\u201360.","journal-title":"Int J Implant Dent"},{"key":"8069_CR14","doi-asserted-by":"publisher","first-page":"445","DOI":"10.21608\/edj.2019.72720","volume":"65","author":"MS Nabhan","year":"2019","unstructured":"Nabhan MS. Effect of different fixed detachable implant supported prosthesis materials on the stresses induced on the supporting structures. Egypt Dent J. 2019;65:445\u201352.","journal-title":"Egypt Dent J"},{"key":"8069_CR15","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1016\/j.jbiomech.2014.10.022","volume":"48","author":"SA Bilhan","year":"2015","unstructured":"Bilhan SA, Baykasoglu C, Bilhan H. Effect of attachment types and number of implants supporting mandibular overdentures on stress distribution: a computed tomography-based 3D finite element analysis. J Biomech. 2015;48:130\u20137.","journal-title":"J Biomech"},{"issue":"1","key":"8069_CR16","doi-asserted-by":"publisher","first-page":"13","DOI":"10.4103\/jips.jips_478_21","volume":"22","author":"N Chatterjee","year":"2022","unstructured":"Chatterjee N, Ghosh A. Current scenario on adhesion to zirconia; surface pretreatments and resin cements: A. systematic review. J Indian Prosthodont Soc. 2022;22(1):13\u201320.","journal-title":"J Indian Prosthodont Soc"},{"issue":"7","key":"8069_CR17","doi-asserted-by":"publisher","first-page":"833","DOI":"10.3390\/coatings15070833","volume":"15","author":"WA Uriciuc","year":"2025","unstructured":"Uriciuc WA, Suciu M, Barbu-Tudoran L, Botean AI, Chicinas HF, Anghel MA, Popa CO, et al. A Surface Treatments onCobalt\u2013Chromium Alloys for Layering Ceramic Paint Coatings in Dental Prosthetics. Coatings. 2025;15(7):833\u201344.","journal-title":"Coatings"},{"key":"8069_CR18","doi-asserted-by":"crossref","unstructured":"Mohamed SZ, Ghobashy MM, Taymour N, Abdelwahab S, Srimaneepong V, Rokaya D. Accuracy of repaired maxillary dentures from two different repairing techniques: In vitro study. H e l i y o n 1 0.2042; e40017.1-8.","DOI":"10.1016\/j.heliyon.2024.e40017"},{"key":"8069_CR19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2013\/351279","volume":"6","author":"R Shahmiri","year":"2013","unstructured":"Shahmiri R, Aarts JM, Bennani V, Das R, Swain MV. Strain distribution in a Kennedy class I implant assisted removable partial denture under various loading conditions. Int J Dent. 2013;6:1\u201311.","journal-title":"Int J Dent"},{"key":"8069_CR20","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1109\/19.989890","volume":"51","author":"JG Da Silva","year":"2002","unstructured":"Da Silva JG, de Carvalho AA, Da Silva DD. A strain gauge tactile sensor for finger-mounted applications. IEEE Trans Instrum Meas. 2002;51:18\u201322.","journal-title":"IEEE Trans Instrum Meas"},{"key":"8069_CR21","doi-asserted-by":"crossref","unstructured":"Assun\u00e7\u00e3o WG, Bar\u00e3o VA, Tabata LF, Gomes EA, Delben JA and dos, Santos PH. Biomechanics studies in dentistry: bioengineering applied in oral implantology. J Craniofacial Sur. 2009; 20: 1173\u20131177.","DOI":"10.1097\/SCS.0b013e3181acdb81"},{"key":"8069_CR22","doi-asserted-by":"publisher","first-page":"103514","DOI":"10.1016\/j.jmbbm.2019.103514","volume":"130","author":"T Hada","year":"2020","unstructured":"Hada T, Suzuki T, Shunsuke Minakuchi S, Takahashi H. Reduction in maxillary complete denture deformation using framework material made by computer-aided design and manufacturing systems. J Mech Behav Biomed Mat. 2020;130:103514\u201322.","journal-title":"J Mech Behav Biomed Mat"},{"key":"8069_CR23","doi-asserted-by":"publisher","first-page":"507","DOI":"10.4012\/dmj.28.507","volume":"28","author":"Y Hirajima","year":"2009","unstructured":"Hirajima Y, Takahashi H, Minakuchi S. Influence of a denture strengthener on the deformation of a maxillary complete denture. Dent Mat J. 2009;28:507\u201312.","journal-title":"Dent Mat J"},{"key":"8069_CR24","first-page":"804","volume":"121","author":"SD Heintze","year":"2011","unstructured":"Heintze SD, Zimmerli B. Relevance of in vitro tests of adhesive and composite dental materials, a review in 3 parts. Part 1: approval requirements and standardized testing of composite materials according to ISO specifications. Schweiz Monatsschr Zahnmed. 2011;121:804\u201316.","journal-title":"Schweiz Monatsschr Zahnmed"},{"key":"8069_CR25","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/j.prosdent.2016.08.012","volume":"117","author":"P Sia","year":"2017","unstructured":"Sia P, Masri R, Driscoll F, Romberg E. Effect of locator abutment height on the retentive values of pink locator attachments: an in vitro study. J Prosthet Dent. 2017;117:283\u20137.","journal-title":"J Prosthet Dent"},{"key":"8069_CR26","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1067\/mpr.2002.126818","volume":"88","author":"TD Taylor","year":"2002","unstructured":"Taylor TD, Agar JR. Twenty years of progress in implant prosthodontics. J Prosthet Dent. 2002;88:89\u201395.","journal-title":"J Prosthet Dent"},{"key":"8069_CR27","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1016\/j.prosdent.2017.07.016","volume":"119","author":"CF Amaral","year":"2018","unstructured":"Amaral CF, Gomes RS, Garcia RC, Cury AA. Stress distribution of single-implant\u2013retained overdenture reinforced with a framework: A finite element analysis study. J Prosthet Dent. 2018;119:791\u20136.","journal-title":"J Prosthet Dent"},{"key":"8069_CR28","first-page":"38","volume":"53","author":"M Freedman","year":"2007","unstructured":"Freedman M, Quinn F, O\u2019Sullivan M. Single unit CAD\/CAM restorations: a literature review. J Ir Dent Associ. 2007;53:38\u201345.","journal-title":"J Ir Dent Associ"},{"key":"8069_CR29","doi-asserted-by":"crossref","unstructured":"Ahmed N, Abbasi MS, Haider S, Ahmed N, Habib SR, Altamash S et al. Fit accuracy of removable partial denture frameworks fabricated with CAD\/ CAM, rapid prototyping, and conventional techniques: a systematic review. Biomed Res Int. 2021.","DOI":"10.1155\/2021\/3194433"},{"key":"8069_CR30","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1111\/j.1741-2358.2008.00268.x","volume":"26","author":"WG Assuncao","year":"2009","unstructured":"Assuncao WG, Barao VA, Tabata LF, de Sousa EA, Gomes EA, Delben JA. Comparison between complete denture and implant retained overdenture: effect of different mucosa thickness and resiliency on stress distribution. Gerodontology. 2009;26:273\u201381.","journal-title":"Gerodontology"},{"key":"8069_CR31","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1590\/0103-6440201801746","volume":"29","author":"SL Moraes","year":"2018","unstructured":"Moraes SL, Verri FR, J\u00fanior S, Ferreira J, Almeida DA, Lemos CA, et al. Three-dimensional finite element analysis of varying diameter and connection type in implants with high crown-implant ratio. Braz Dent j. 2018;29:36\u201342.","journal-title":"Braz Dent j"},{"key":"8069_CR32","first-page":"39","volume":"4","author":"AA El-Gendy","year":"2007","unstructured":"El-Gendy AA. Micro-strain evaluation of different implant positions supporting mandibular bilateral distal extension partial over denture. Tanta Dent J. 2007;4:39\u201346.","journal-title":"Tanta Dent J"},{"key":"8069_CR33","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.jpor.2017.05.001","volume":"62","author":"H Nasution","year":"2017","unstructured":"Nasution H, Kamonkhantikul K, Arksornnukit M, Takahashi H. Pressure transmission area and maximum pressure transmission of different thermoplastic resin denture base materials under impact load. J Prosthet Res. 2017;62:44\u20139.","journal-title":"J Prosthet Res"},{"key":"8069_CR34","first-page":"1551","volume":"68","author":"RA El Sharabasy","year":"2022","unstructured":"El Sharabasy RA, Abdelfatah WS, Kortam SA. Radiographic and clinical evaluation of CAD-CAM milled peek and peek partial denture framework on supporting structures versus metallic one: comparative randomized clinical study. E D J. 2022;68:1551\u201366.","journal-title":"E D J"},{"key":"8069_CR35","volume-title":"Metals in dental prosthodontics","author":"J \u017divko-Babi\u0192","year":"2005","unstructured":"\u017divko-Babi\u0192 J. and Jerolimov V. Metals in dental prosthodontics. Zagreb: \u0160kolska knjiga; 2005."},{"key":"8069_CR36","volume-title":"Dental materials: properties and manipulation","author":"RG Craig","year":"2000","unstructured":"Craig RG, Powers JM, Wataha JC. Dental materials: properties and manipulation. St Louis: Mosby; 2000."},{"key":"8069_CR37","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1111\/j.1532-849X.1993.tb00398.x","volume":"2","author":"DA Bridgeport","year":"1993","unstructured":"Bridgeport DA, Brantley WA, Herman PF. Cobalt-chromium and nickel-chromium alloys for removable prosthodontics, part 1: mechanical properties. J Prosthodont. 1993;2:144\u201350.","journal-title":"J Prosthodont"},{"key":"8069_CR38","first-page":"1","volume":"2","author":"SN ELshaboury","year":"2020","unstructured":"ELshaboury SN, Mahanna FF, Ahmed WS, Waseef EL. Cobalt chromium vs. peek for reinforcing single implant mandibular overdentures: A clinical study of strain analysis. J Dent Oral Sci. 2020;2:1\u201312.","journal-title":"J Dent Oral Sci"},{"key":"8069_CR39","first-page":"20","volume":"6","author":"O Alsadon","year":"2017","unstructured":"Alsadon O, David Patrick D, Johnson A, Pollington S, Wood D. Fracture resistance of zirconia-composite veneered crowns in comparison with zirconia-porcelain crowns. Dent Mat J. 2017;6:20\u20135.","journal-title":"Dent Mat J"},{"key":"8069_CR40","first-page":"787","volume":"68","author":"MA Alkhodary","year":"2022","unstructured":"Alkhodary MA. Zirconia Versus Cobalt Chromium Meshwork Reinforcement of implant- assisted mandibular overdenture. EDJ. 2022;68:787\u201394.","journal-title":"EDJ"},{"key":"8069_CR41","first-page":"54","volume":"20","author":"G Skirbutis","year":"2018","unstructured":"Skirbutis G, Dzingut\u0117 A, Masili\u016bnait\u0117 V, \u0160ulcait\u0117 G, \u017dilinskas J. PEEK polymer\u2019s properties and its use in prosthodontics. A review. Stomatologija. 2018;20:54\u20138.","journal-title":"Stomatologija"},{"key":"8069_CR42","first-page":"2459","volume":"63","author":"MAM Helal","year":"2017","unstructured":"Helal MAM, Abd El Rahman IA, Sakar HM, Gomaa AS, Abbas M. Evaluation of acetal resin and cobalt chromium clasp deformation and fatigue resistance in removable partial denture clasps. An in-vitro study. EDJ. 2017;63:2459\u201364.","journal-title":"EDJ"},{"key":"8069_CR43","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1080\/17436753.2017.1336365","volume":"116","author":"Y Zhang","year":"2017","unstructured":"Zhang Y, Han JM, Zheng G, Lin H, Bai W, Zhao J, Shen Z. Fatigue behaviors of the zirconia dental restorations prepared by two manufacturing methods. Adva Appli Cer. 2017;116:368\u201375.","journal-title":"Adva Appli Cer"},{"key":"8069_CR44","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1016\/j.dental.2005.12.008","volume":"23","author":"AR Studart","year":"2007","unstructured":"Studart AR, Filser F, Kocher P, Gauckler LJ. Fatigue of zirconia under cyclic loading in water and its implications for the design of dental bridges. Dent mat. 2007;23:106\u201314.","journal-title":"Dent mat"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-08069-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-08069-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-08069-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T20:57:28Z","timestamp":1781643448000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-08069-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,27]]},"references-count":44,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["8069"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-08069-0","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,27]]},"assertion":[{"value":"5 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the Ethical Committee of the British University in Egypt (BUE) \u201cin accordance with the Declaration of Helsinki\u201d. with research approval number 24\u2013046. Consent to participate \u201cNot applicable\u201d this study didn\u2019t involve the use of any animal or human data or tissue.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"629"}}