{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T23:54:22Z","timestamp":1781567662492,"version":"3.54.5"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T00:00:00Z","timestamp":1776643200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T00:00:00Z","timestamp":1781568000000},"content-version":"vor","delay-in-days":57,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"DOI":"10.1186\/s12903-026-08137-5","type":"journal-article","created":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T15:14:39Z","timestamp":1776698079000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Effect of implant number, attachment type, and framework material on stress distribution in mandibular overdentures: a finite element analysis"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-0361-1074","authenticated-orcid":false,"given":"Serhat","family":"Sai\u0307p","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9767-0080","authenticated-orcid":false,"given":"Zeynep","family":"Ye\u015fi\u0307l","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,20]]},"reference":[{"key":"8137_CR1","volume-title":"Clinical and laboratory manual of implant overdentures","author":"HR Shafie","year":"2013","unstructured":"Shafie HR. Clinical and laboratory manual of implant overdentures. John Wiley & Sons; 2013."},{"issue":"1","key":"8137_CR2","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1067\/mpr.2000.107113","volume":"84","author":"TO N\u00e4rhi","year":"2000","unstructured":"N\u00e4rhi TO, Geertman ME, Hevinga M, Abdo H, Kalk W, Nijmegen TN, et al. Changes in the edentulous maxilla in persons wearing implant-retained mandibular overdentures. J Prosthet Dent. 2000;84(1):43\u20139.","journal-title":"J Prosthet Dent"},{"key":"8137_CR3","unstructured":"Misch C. Dental implant prosthetics, editor. St louis, Missouri 2005, 63146."},{"issue":"3","key":"8137_CR4","first-page":"113","volume":"7","author":"F Tabatabaian","year":"2010","unstructured":"Tabatabaian F, Alaie F, Seyedan K. Comparison of three attachments in implant-tissue supported overdentures: an in vitro study. J Dentistry (Tehran Iran). 2010;7(3):113.","journal-title":"J Dentistry (Tehran Iran)"},{"key":"8137_CR5","first-page":"1","volume":"2","author":"M Ulusoy","year":"2010","unstructured":"Ulusoy M, AYDIN K. Di\u015f Hekimli\u011finde Hareketli B\u00f6l\u00fcml\u00fc Protezler, Ankara \u00dcnv. Di\u015f Hek Fak Yay\u0131nlar\u0131. 2010;2:1\u20132.","journal-title":"Di\u015f Hek Fak Yay\u0131nlar\u0131"},{"issue":"5","key":"8137_CR6","first-page":"270","volume":"29","author":"RC Vogel","year":"2008","unstructured":"Vogel RC. CE 2-implant overdentures: a new standard of care for edentulous patients\u2013current concepts and techniques. Compendium. 2008;29(5):270.","journal-title":"Compendium"},{"key":"8137_CR7","volume-title":"Dental Implant Prosthetics","author":"C Misch","year":"2015","unstructured":"Misch C. Dental Implant Prosthetics. Edisi ke-2. Elsevier Inc; 2015.","edition":"Edisi ke-2"},{"issue":"8","key":"8137_CR8","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1111\/joor.12651","volume":"45","author":"R Le\u00e3o","year":"2018","unstructured":"Le\u00e3o R, Moraes S, Vasconcelos B, Lemos C, Pellizzer E. Splinted and unsplinted overdenture attachment systems: a systematic review and meta-analysis. J Rehabil. 2018;45(8):647\u201356.","journal-title":"J Rehabil"},{"issue":"11","key":"8137_CR9","doi-asserted-by":"publisher","first-page":"1406","DOI":"10.1111\/clr.13003","volume":"28","author":"N Sultana","year":"2017","unstructured":"Sultana N, Bartlett DW, Suleiman M. Retention of implant-supported overdentures at different implant angulations: comparing Locator and ball attachments. Clin Oral Implants Res. 2017;28(11):1406\u201310.","journal-title":"Clin Oral Implants Res"},{"key":"8137_CR10","unstructured":"Geckili O, Bilhan H, Bilgin T. Locator Attachments as an Alternative to Ball Attachments in 2-Implant Retained Mandibular Overdentures. J Can Dent Assoc 2007, 73(8)."},{"issue":"5","key":"8137_CR11","doi-asserted-by":"publisher","first-page":"865. e861","DOI":"10.1016\/j.prosdent.2019.02.010","volume":"121","author":"G Berger","year":"2019","unstructured":"Berger G, de Oliveira Pereira LF, de Souza EM, Rached RN. A 3D finite element analysis of glass fiber reinforcement designs on the stress of an implant-supported overdenture. J Prosthet Dent. 2019;121(5):865. e861-865. e867.","journal-title":"J Prosthet Dent"},{"key":"8137_CR12","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1034\/j.1600-0501.2000.011S1108.x","volume":"7","author":"D Mericske-Stern","year":"2000","unstructured":"Mericske-Stern D, Taylor R, Belser TD. Management of the edentulous patient. Clin Oral Implants Research: Chap. 2000;7:11:108\u201325.","journal-title":"Clin Oral Implants Research: Chap"},{"key":"8137_CR13","doi-asserted-by":"crossref","unstructured":"Im S-M, Huh Y-H, Cho L-R, Park C-J. Comparison of the fracture resistances of glass fiber mesh-and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading. J Adv Prosthodont 2017, 9(1):22\u201330.","DOI":"10.4047\/jap.2017.9.1.22"},{"issue":"1","key":"8137_CR14","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1080\/23337931.2018.1457445","volume":"4","author":"PK Vallittu","year":"2018","unstructured":"Vallittu PK. An overview of development and status of fiber-reinforced composites as dental and medical biomaterials. Acta Biomater Odontol Scand. 2018;4(1):44\u201355.","journal-title":"Acta Biomater Odontol Scand"},{"key":"8137_CR15","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1016\/j.jmbbm.2018.12.006","volume":"91","author":"MF Gibreel","year":"2019","unstructured":"Gibreel MF, Khalifa A, Said MM, Mahanna F, El-Amier N, N\u00e4rhi TO, Perea-Lowery L, Vallittu PK. Biomechanical aspects of reinforced implant overdentures: a systematic review. J Mech Behav Biomed Mater. 2019;91:202\u201311.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"1","key":"8137_CR16","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-50363-1","volume":"9","author":"X Chen","year":"2019","unstructured":"Chen X, Mao B, Zhu Z, Yu J, Lu Y, Zhang Q, et al. A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEK. Sci Rep. 2019;9(1):13975.","journal-title":"Sci Rep"},{"issue":"7","key":"8137_CR17","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1080\/10255842.2017.1302432","volume":"20","author":"K Solberg","year":"2017","unstructured":"Solberg K, Heinemann F, Pellikaan P, Keilig L, Stark H, Bourauel C, Hasan I. Finite element analysis of different loading conditions for implant-supported overdentures supported by conventional or mini implants. Comput Methods Biomech BioMed Eng. 2017;20(7):770\u201382.","journal-title":"Comput Methods Biomech BioMed Eng"},{"issue":"3","key":"8137_CR18","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1111\/j.1365-2842.2004.01407.x","volume":"32","author":"HJ Chun","year":"2005","unstructured":"Chun HJ, Park DN, Han CH, Heo SJ, Heo MS, Koak JY. Stress distributions in maxillary bone surrounding overdenture implants with different overdenture attachments. J Rehabil. 2005;32(3):193\u2013205.","journal-title":"J Rehabil"},{"issue":"1","key":"8137_CR19","doi-asserted-by":"publisher","first-page":"31","DOI":"10.4103\/0970-9290.49058","volume":"20","author":"V Prakash","year":"2009","unstructured":"Prakash V, Mariette D, Adhikari R. A comparison of stress distribution and flexion among various designs of bar attachments for implant overdentures: a three dimensional finite element analysis. Indian J Dent Res. 2009;20(1):31\u20136.","journal-title":"Indian J Dent Res"},{"issue":"7","key":"8137_CR20","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.1177\/00220345000790071501","volume":"79","author":"F Fontijn-Tekamp","year":"2000","unstructured":"Fontijn-Tekamp F, Slagter A, Van Der Bilt A, Van\u2019T Hof M, Witter D, Kalk W, et al. Biting and chewing in overdentures, full dentures, and natural dentitions. J Dent Res. 2000;79(7):1519\u201324.","journal-title":"J Dent Res"},{"key":"8137_CR21","unstructured":"Walton JN, Glick N, MacEntee MI. A randomized clinical trial comparing patient satisfaction and prosthetic outcomes with mandibular overdentures retained by one or two implants. Int J Prosthodont 2009, 22(4)."},{"issue":"7","key":"8137_CR22","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1111\/j.1600-0501.2009.01710.x","volume":"20","author":"HJ Meijer","year":"2009","unstructured":"Meijer HJ, Raghoebar GM, Batenburg RH, Visser A, Vissink A. Mandibular overdentures supported by two or four endosseous implants: a 10-year clinical trial. Clin Oral Implants Res. 2009;20(7):722\u20138.","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"8137_CR23","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1111\/j.1600-0501.2004.01085.x","volume":"16","author":"A Visser","year":"2005","unstructured":"Visser A, Raghoebar GM, Meijer HJ, Batenburg RH, Vissink A. Mandibular overdentures supported by two or four endosseous implants: a 5-year prospective study. Clin Oral Implants Res. 2005;16(1):19\u201325.","journal-title":"Clin Oral Implants Res"},{"issue":"5","key":"8137_CR24","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1067\/mpr.2001.119921","volume":"86","author":"SJ Sadowsky","year":"2001","unstructured":"Sadowsky SJ. Mandibular implant-retained overdentures: a literature review. J Prosthet Dent. 2001;86(5):468\u201373.","journal-title":"J Prosthet Dent"},{"issue":"5","key":"8137_CR25","volume":"2","author":"A Abdelhamid","year":"2015","unstructured":"Abdelhamid A, Assaad N, Neena A. Three dimensional finite element analysis to evaluate stress distribution around implant retained mandibular overdenture using two different attachment systems. J Dent Health Oral Disord Ther. 2015;2(5):00065.","journal-title":"J Dent Health Oral Disord Ther"},{"issue":"4","key":"8137_CR26","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/j.sdentj.2015.03.001","volume":"27","author":"MI El-Anwar","year":"2015","unstructured":"El-Anwar MI, Yousief SA, Soliman TA, Saleh MM, Omar WS. A finite element study on stress distribution of two different attachment designs under implant supported overdenture. Saudi Dent J. 2015;27(4):201\u20137.","journal-title":"Saudi Dent J"},{"key":"8137_CR27","doi-asserted-by":"publisher","DOI":"10.1177\/1758736015576009","volume":"6","author":"N Yoda","year":"2015","unstructured":"Yoda N, Matsudate Y, Abue M, Hong G, Sasaki K. Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures. J Dent Biomech. 2015;6:1758736015576009.","journal-title":"J Dent Biomech"},{"issue":"4","key":"8137_CR28","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.prosdent.2007.02.006","volume":"97","author":"G Celik","year":"2007","unstructured":"Celik G, Uludag B. Photoelastic stress analysis of various retention mechanisms on 3-implant-retained mandibular overdentures. J Prosthet Dent. 2007;97(4):229\u201335.","journal-title":"J Prosthet Dent"},{"issue":"5","key":"8137_CR29","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1016\/j.prosdent.2017.07.016","volume":"119","author":"CF Amaral","year":"2018","unstructured":"Amaral CF, Gomes RS, Garcia RCR, Cury AADB. Stress distribution of single-implant\u2013retained overdenture reinforced with a framework: a finite element analysis study. J Prosthet Dent. 2018;119(5):791\u20136.","journal-title":"J Prosthet Dent"},{"issue":"5","key":"8137_CR30","doi-asserted-by":"publisher","first-page":"446","DOI":"10.4103\/jispcd.JISPCD_183_18","volume":"8","author":"OAL Jaros","year":"2018","unstructured":"Jaros OAL, De Carvalho GAP, Franco ABG, Kreve S, Lopes PAB, Dias SC. Biomechanical behavior of an implant system using polyether ether ketone bar: finite element analysis. J Int Soc Prev Community Dent. 2018;8(5):446\u201350.","journal-title":"J Int Soc Prev Community Dent"},{"key":"8137_CR31","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.msec.2017.02.034","volume":"75","author":"RS Gomes","year":"2017","unstructured":"Gomes RS, Bergamo ETP, Bordin D, Cury AADB. The substitution of the implant and abutment for their analogs in mechanical studies: in vitro and in silico analysis. Mater Sci Engineering: C. 2017;75:50\u20134.","journal-title":"Mater Sci Engineering: C"},{"issue":"2","key":"8137_CR32","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1590\/0103-6440201300258","volume":"26","author":"LB Durand","year":"2015","unstructured":"Durand LB, Guimar\u00e3es JC, Monteiro S, Baratieri LN. Effect of ceramic thickness and composite bases on stress distribution of inlays-a finite element analysis. Braz Dent J. 2015;26(2):146\u201351.","journal-title":"Braz Dent J"},{"key":"8137_CR33","first-page":"43","volume":"9","author":"GV Anehosur","year":"2019","unstructured":"Anehosur GV, Medappa P, Venkitakrishnan VV, Gupta M, Meshramkar RP, Pillai LK. Stress distribution analysis at the bone\u2013implant interface using four different superstructure materials in an implant-retained mandibular overdenture: a photoelastic study. Int J Prosthodont Restor Dent. 2019;9:43\u20136.","journal-title":"Int J Prosthodont Restor Dent"},{"issue":"3-July (Fixed P","key":"8137_CR34","doi-asserted-by":"publisher","first-page":"1817","DOI":"10.21608\/edj.2020.33441.1160","volume":"66","author":"SA Kortam","year":"2020","unstructured":"Kortam SA. Metal versus poly ether-ether ketone (PEEK) framework reinforcements for maxillary palateless ball retained implant overdentures. One year clinical and radiographic outcomes. Egypt Dent J. 2020;66(3-July (Fixed Prosthodontics, Removable Prosthodontics and Dental Materials)):1817\u201328.","journal-title":"Egypt Dent J"},{"issue":"1","key":"8137_CR35","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4103\/1735-3327.310031","volume":"18","author":"KC Kelkar","year":"2021","unstructured":"Kelkar KC, Bhat V, Hegde C. Finite element analysis of the effect of framework materials at the bone\u2013implant interface in the all-on-four implant system. Dent Res J. 2021;18(1):1.","journal-title":"Dent Res J"},{"key":"8137_CR36","doi-asserted-by":"crossref","unstructured":"Lee K-S, Shin S-W, Lee S-P, Kim J-E, Kim J-H, Lee J-Y. Comparative Evaluation of a Four-Implant-Supported Polyetherketoneketone Framework Prosthesis: A Three-Dimensional Finite Element Analysis Based on Cone Beam Computed Tomography and Computer-Aided Design. Int J Prosthodont 2017, 30(6).","DOI":"10.11607\/ijp.5369"},{"issue":"3","key":"8137_CR37","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1016\/j.prosdent.2017.12.012","volume":"120","author":"MX Pisani","year":"2018","unstructured":"Pisani MX, Presotto AGC, Mesquita MF, Bar\u00e3o VAR, Kemmoku DT, Cury AADB. Biomechanical behavior of 2-implant\u2013and single-implant\u2013retained mandibular overdentures with conventional or mini implants. J Prosthet Dent. 2018;120(3):421\u201330.","journal-title":"J Prosthet Dent"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-08137-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-08137-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-08137-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T23:23:33Z","timestamp":1781565813000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-08137-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,20]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["8137"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-08137-5","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,20]]},"assertion":[{"value":"14 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval was obtained from the Non-Invasive Clinical Research Ethics Committee of Recep Tayyip Erdo\u011fan University (Decision no: 2024\/104). We confirm that all methods are performed in accordance with relevant guidelines and regulations. Ethics Committee of Recep Tayyip Erdo\u011fan University waived the need for informed consent as all the work is done in computer environment.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1035"}}