{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T07:06:23Z","timestamp":1784185583712,"version":"3.55.0"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T00:00:00Z","timestamp":1777507200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T00:00:00Z","timestamp":1784160000000},"content-version":"vor","delay-in-days":77,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>High-flow bulk-fill (HFB) resin composites have been introduced to simplify restorative procedures by enabling bulk placement and improved cavity adaptation. However, evidence is limited regarding whether their mechanical performance as stand-alone materials is consistent across different testing geometries. This study aimed to compare the flexural strength and fracture load of HFB composites with a conventional paste-like posterior composite using ISO 4049\u00a0bar specimens and MOD shaped restorations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Eighty specimens were fabricated and divided into two specimen configurations: ISO 4049\u00a0bar specimens (25\u2009\u00d7\u20092\u2009\u00d7\u20092\u00a0mm) and MOD shaped restorations (12\u2009\u00d7\u20097\u2009\u00d7\u20095\u00a0mm) (\n                      <jats:italic>N<\/jats:italic>\n                      \u2009=\u200940 each). Three HFB composites\u2014Clearfil Majesty ES High Flow (CM), Tetric N Flow Bulk Fill (TF), and Estelite Universal High Flow (EU)\u2014and one conventional paste-like posterior composite (GC G-aenial Posterior; GP) were tested (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200910 per subgroup). ISO specimens were evaluated for flexural strength (MPa) and MOD specimens evaluated for fracture load (N) using a three-point bending and fracture load test at 1\u00a0mm\/min. Data were analyzed using one-way ANOVA and Tukey post hoc tests (\u03b1\u2009=\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Remarkably, the mechanical outcomes varied depending on the tested composite material and the specimen configuration (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05). In MOD shaped restorations, TF demonstrated the highest fracture load (1198.33\u2009\u00b1\u2009188.83\u00a0N), followed by EU (1007.76\u2009\u00b1\u2009182.37\u00a0N), GP (871.92\u2009\u00b1\u2009227.67\u00a0N), and CM (776.10\u2009\u00b1\u200993.06\u00a0N). In ISO 4049\u00a0bar specimens, EU exhibited significantly higher flexural strength (85.84\u2009\u00b1\u200923.43\u00a0MPa) compared with CM (61.76\u2009\u00b1\u20092.99\u00a0MPa), TF (55.27\u2009\u00b1\u200912.04\u00a0MPa), and GP (54.19\u2009\u00b1\u200911.57\u00a0MPa) (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05). Material ranking differed between ISO bar and MOD specimen configurations.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>HFB resin composites showed flexural strength and fracture load values comparable to or higher than those of the conventional paste-like posterior composite. However, performance was material-dependent and influenced by specimen geometry. These findings highlight the importance of combining standardized and geometry-dependent testing approaches for a more comprehensive evaluation of restorative materials.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-026-08494-1","type":"journal-article","created":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T13:46:16Z","timestamp":1777556776000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Flexural strength and fracture load of high-flow bulk-fill and conventional composites in ISO 4049 bars and MOD cavity models: an in vitro study"],"prefix":"10.1186","volume":"26","author":[{"given":"Burcu","family":"\u00d6zt\u00fcrk","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elif Asl\u0131han","family":"Kahraman Kar\u015f\u0131gil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fulya","family":"Ayd\u0131n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,30]]},"reference":[{"issue":"9","key":"8494_CR1","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1016\/j.jdent.2009.04.010","volume":"37","author":"K Sunneg\u00e5rdh-Gr\u00f6nberg","year":"2009","unstructured":"Sunneg\u00e5rdh-Gr\u00f6nberg K, et al. Selection of dental materials and longevity of replaced restorations in public dental health clinics in northern Sweden. J Dent. 2009;37(9):673\u20138.","journal-title":"J Dent"},{"issue":"3","key":"8494_CR2","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1038\/s41432-023-00905-4","volume":"24","author":"A Sengupta","year":"2023","unstructured":"Sengupta A, et al. The clinical performance of bulk-fill versus the incremental layered application of direct resin composite restorations: a systematic review. Evid Based Dent. 2023;24(3):143\u2013143.","journal-title":"Evid Based Dent"},{"issue":"5","key":"8494_CR3","doi-asserted-by":"publisher","first-page":"1717","DOI":"10.1007\/s00784-016-1953-6","volume":"21","author":"TA Omran","year":"2017","unstructured":"Omran TA, et al. Influence of increment thickness on dentin bond strength and light transmission of composite base materials. Clin Oral Investig. 2017;21(5):1717\u201324.","journal-title":"Clin Oral Investig"},{"issue":"6","key":"8494_CR4","doi-asserted-by":"publisher","first-page":"618","DOI":"10.2341\/12-395-L","volume":"38","author":"N Ilie","year":"2013","unstructured":"Ilie N, Bucuta S, Draenert M. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent. 2013;38(6):618\u201325.","journal-title":"Oper Dent"},{"issue":"3","key":"8494_CR5","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.dental.2014.12.010","volume":"31","author":"J Zorzin","year":"2015","unstructured":"Zorzin J, et al. Bulk-fill resin composites: polymerization properties and extended light curing. Dent Mater. 2015;31(3):293\u2013301.","journal-title":"Dent Mater"},{"issue":"2","key":"8494_CR6","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1016\/j.dental.2013.10.011","volume":"30","author":"A Alrahlah","year":"2014","unstructured":"Alrahlah A, Silikas N, Watts DC. Post-cure depth of cure of bulk fill dental resin-composites. Dent Mater. 2014;30(2):149\u201354.","journal-title":"Dent Mater"},{"issue":"3","key":"8494_CR7","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1016\/j.dental.2012.11.002","volume":"29","author":"A Van Ende","year":"2013","unstructured":"Van Ende A, et al. Bulk-filling of high C-factor posterior cavities: effect on adhesion to cavity-bottom dentin. Dent Mater. 2013;29(3):269\u201377.","journal-title":"Dent Mater"},{"issue":"8","key":"8494_CR8","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1016\/j.jdent.2014.05.012","volume":"42","author":"N Ilie","year":"2014","unstructured":"Ilie N, Stark K. Curing behaviour of high-viscosity bulk-fill composites. J Dent. 2014;42(8):977\u201385.","journal-title":"J Dent"},{"issue":"8","key":"8494_CR9","doi-asserted-by":"publisher","first-page":"1991","DOI":"10.1007\/s00784-013-1177-y","volume":"18","author":"S Bucuta","year":"2014","unstructured":"Bucuta S, Ilie N. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites. Clin Oral Investig. 2014;18(8):1991\u20132000.","journal-title":"Clin Oral Investig"},{"issue":"1","key":"8494_CR10","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-025-05951-1","volume":"25","author":"RA Wafaie","year":"2025","unstructured":"Wafaie RA, Ahmed B, Mahmoud SH. Fracture resistance of molars with class II MOD cavities restored with bulk-fill, no-cap flowable bulk-fill, and conventional resin composite restorative systems after 6-months water storage. BMC Oral Health. 2025;25(1):741.","journal-title":"BMC Oral Health"},{"issue":"4","key":"8494_CR11","doi-asserted-by":"publisher","first-page":"375","DOI":"10.2341\/16-254-L","volume":"42","author":"J Jung","year":"2017","unstructured":"Jung J, Park S. Comparison of polymerization shrinkage, physical properties, and marginal adaptation of flowable and restorative bulk fill resin-based composites. Oper Dent. 2017;42(4):375\u201386.","journal-title":"Oper Dent"},{"issue":"5","key":"8494_CR12","doi-asserted-by":"publisher","first-page":"567","DOI":"10.14219\/jada.archive.1998.0274","volume":"129","author":"SC Bayne","year":"1998","unstructured":"Bayne SC, et al. A characterization of first-generation flowable composites. J Am Dent Assoc. 1998;129(5):567\u201377.","journal-title":"J Am Dent Assoc"},{"key":"8494_CR13","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2023.105747","volume":"140","author":"H Chai","year":"2023","unstructured":"Chai H. On the fracture behavior of molar teeth with MOD cavity preparation. J Mech Behav Biomed Mater. 2023;140:105747.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"4","key":"8494_CR14","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1111\/j.1365-2842.1997.tb00325.x","volume":"24","author":"P Jacobsen","year":"1997","unstructured":"Jacobsen P, Darr A. Static and dynamic moduli of composite restorative materials. J Rehabil. 1997;24(4):265\u201373.","journal-title":"J Rehabil"},{"issue":"2","key":"8494_CR15","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1046\/j.1365-2842.2003.01004.x","volume":"30","author":"AU Yap","year":"2003","unstructured":"Yap AU, Teoh SH. Comparison of flexural properties of composite restoratives using the ISO and mini-flexural tests. J Oral Rehabil. 2003;30(2):171\u20137.","journal-title":"J Oral Rehabil"},{"issue":"6","key":"8494_CR16","first-page":"713","volume":"29","author":"A Olmez","year":"2004","unstructured":"Olmez A, Oztas N, Bodur H. The effect of flowable resin composite on microleakage and internal voids in class II composite restorations. Oper Dent. 2004;29(6):713\u20139.","journal-title":"Oper Dent"},{"issue":"2","key":"8494_CR17","doi-asserted-by":"publisher","first-page":"e111","DOI":"10.4317\/jced.61153","volume":"16","author":"A Signore","year":"2024","unstructured":"Signore A, et al. A 24-month randomized clinical study of flowable bulk-fill resin composites in class III restorations. J Clin Exp Dent. 2024;16(2):e111-23.","journal-title":"J Clin Exp Dent"},{"issue":"2","key":"8494_CR18","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1007\/s00784-025-06207-6","volume":"29","author":"S Han\u00e7er Sar\u0131ca","year":"2025","unstructured":"Han\u00e7er Sar\u0131ca S, Arslan S, Balkaya H. Comparison of the 2-year clinical performances of class II restorations using different restorative materials. Clin Oral Investig. 2025;29(2):128.","journal-title":"Clin Oral Investig"},{"key":"8494_CR19","doi-asserted-by":"publisher","DOI":"10.3390\/ma18143370","author":"K Tzimas","year":"2025","unstructured":"Tzimas K, et al. Highly filled flowable composite resins as sole restorative materials: a systematic review. Materials. 2025;18(14).","journal-title":"Materials"},{"key":"8494_CR20","doi-asserted-by":"publisher","DOI":"10.3390\/polym15081847","author":"A Alshehri","year":"2023","unstructured":"Alshehri A, et al. No-cap flowable bulk-fill composite: physico-mechanical assessment. Polymers (Basel). 2023;15(8).","journal-title":"Polymers"},{"key":"8494_CR21","first-page":"27","volume":"1","author":"I Standard","year":"2000","unstructured":"Standard I. ISO 4049 polymer based filling, restorative and luting materials. Int Organ Stand. 2000;1:27.","journal-title":"Int Organ Stand"},{"issue":"8","key":"8494_CR22","doi-asserted-by":"publisher","first-page":"993","DOI":"10.1016\/j.jdent.2014.05.009","volume":"42","author":"JG Leprince","year":"2014","unstructured":"Leprince JG, et al. Physico-mechanical characteristics of commercially available bulk-fill composites. J Dent. 2014;42(8):993\u20131000.","journal-title":"J Dent"},{"issue":"6","key":"8494_CR23","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1016\/j.dental.2014.03.006","volume":"30","author":"C Goracci","year":"2014","unstructured":"Goracci C, et al. Polymerization efficiency and flexural strength of low-stress restorative composites. Dent Mater. 2014;30(6):688\u201394.","journal-title":"Dent Mater"},{"issue":"8","key":"8494_CR24","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1016\/j.dental.2013.04.016","volume":"29","author":"S Garoushi","year":"2013","unstructured":"Garoushi S, et al. Physical properties and depth of cure of a new short fiber reinforced composite. Dent Mater. 2013;29(8):835\u201341.","journal-title":"Dent Mater"},{"issue":"16","key":"8494_CR25","doi-asserted-by":"publisher","DOI":"10.3390\/polym15163413","volume":"15","author":"V Tsertsidou","year":"2023","unstructured":"Tsertsidou V, et al. Fracture resistance of class II MOD cavities restored by direct and indirect techniques and different materials combination. Polymers Basel. 2023;15(16):3413.","journal-title":"Polymers Basel"},{"key":"8494_CR26","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2020.103947","volume":"110","author":"C \u00d6zcan","year":"2020","unstructured":"\u00d6zcan C, et al. Misinterpretation of ISO 4049 standard recommendations: impact on Young\u2019s modulus and conversion degree of dental composites. J Mech Behav Biomed Mater. 2020;110:103947.","journal-title":"J Mech Behav Biomed Mater"},{"key":"8494_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2025.106181","author":"N Ilie","year":"2025","unstructured":"Ilie N. Influence of test velocity and viscoelasticity on the outcome of the 3-point bending test in modern dental polymer-based composites. J Dent. 2025:106181.","journal-title":"J Dent"},{"issue":"6","key":"8494_CR28","doi-asserted-by":"publisher","first-page":"677","DOI":"10.2341\/22-125-L","volume":"48","author":"AV Foscarini","year":"2023","unstructured":"Foscarini AV, et al. Flexural strength of conventional or bulk-fill resin composite repaired with high- or low-viscosity restorative materials. Oper Dent. 2023;48(6):677\u201388.","journal-title":"Oper Dent"},{"issue":"10","key":"8494_CR29","doi-asserted-by":"publisher","first-page":"962","DOI":"10.1016\/j.dental.2005.04.018","volume":"21","author":"RR Braga","year":"2005","unstructured":"Braga RR, Ballester RY, Ferracane JL. Factors involved in the development of polymerization shrinkage stress in resin-composites: a systematic review. Dent Mater. 2005;21(10):962\u201370.","journal-title":"Dent Mater"},{"issue":"4","key":"8494_CR30","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1016\/j.dental.2010.11.014","volume":"27","author":"N Ilie","year":"2011","unstructured":"Ilie N, Hickel R. Investigations on a methacrylate-based flowable composite based on the SDR\u2122 technology. Dent Mater. 2011;27(4):348\u201355.","journal-title":"Dent Mater"},{"issue":"2","key":"8494_CR31","doi-asserted-by":"publisher","first-page":"173","DOI":"10.54589\/aol.34\/2\/173","volume":"34","author":"FM Fran\u00e7a","year":"2021","unstructured":"Fran\u00e7a FM, et al. Low- and high-viscosity bulk-fill resin composites: a comparison of microhardness, microtensile bond strength, and fracture strength in restored molars. Acta Odontol Latinoam. 2021;34(2):173\u201382.","journal-title":"Acta Odontol Latinoam"},{"issue":"6","key":"8494_CR32","doi-asserted-by":"publisher","first-page":"734","DOI":"10.2341\/05-154","volume":"31","author":"H Lu","year":"2006","unstructured":"Lu H, Lee YK, Oguri M, Powers JM. Properties of a dental resin composite with a spherical inorganic filler. Oper Dent. 2006;31(6):734\u201340.","journal-title":"Oper Dent"},{"key":"8494_CR33","doi-asserted-by":"publisher","DOI":"10.1155\/2022\/1165431","volume":"2022","author":"E Azmy","year":"2022","unstructured":"Azmy E, et al. Impact of nanoparticles additions on the strength of dental composite resin. Int J Biomater. 2022;2022:p1165431.","journal-title":"Int J Biomater"},{"issue":"5","key":"8494_CR34","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1590\/S0103-64402012000500007","volume":"23","author":"VES Gajewski","year":"2012","unstructured":"Gajewski VES, Pfeifer CS, Fr\u00f3es-Salgado NRG, Boaro LCC, Braga RR. Monomers used in resin composites: degree of conversion, mechanical properties and water sorption\/solubility. Braz Dent J. 2012;23(5):508\u201314.","journal-title":"Braz Dent J"},{"issue":"1","key":"8494_CR35","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1111\/j.1532-849X.2006.00151.x","volume":"16","author":"LL Pace","year":"2007","unstructured":"Pace LL, et al. Comparison of the flexural strength of five adhesive resin cements. J Prosthodont. 2007;16(1):18\u201324.","journal-title":"J Prosthodont"},{"issue":"1","key":"8494_CR36","first-page":"205","volume":"29","author":"N Kumar","year":"2013","unstructured":"Kumar N. Inconsistency in the strength testing of dental resin-based composites among researchers. Pakistan J Med Sci. 2013;29(1):205.","journal-title":"Pakistan J Med Sci"},{"issue":"3","key":"8494_CR37","doi-asserted-by":"publisher","first-page":"294","DOI":"10.2341\/21-203-L","volume":"48","author":"L Guerra","year":"2023","unstructured":"Guerra L, et al. Fracture load of molars restored with bulk-fill, flowable bulk-fill, and conventional resin composite after simulated chewing. Oper Dent. 2023;48(3):294\u2013303.","journal-title":"Oper Dent"},{"key":"8494_CR38","doi-asserted-by":"publisher","DOI":"10.3390\/ijms21145136","author":"HJ Haugen","year":"2020","unstructured":"Haugen HJ, et al. Bulk fill composites have similar performance to conventional dental composites. Int J Mol Sci. 2020;21(14).","journal-title":"Int J Mol Sci"},{"issue":"6","key":"8494_CR39","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1111\/jerd.12159","volume":"27","author":"R Hirata","year":"2015","unstructured":"Hirata R, et al. Bulk fill composites: an anatomic sculpting technique. J Esthet Restor Dent. 2015;27(6):335\u201343.","journal-title":"J Esthet Restor Dent"},{"issue":"1","key":"8494_CR40","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1186\/s12903-024-04333-3","volume":"24","author":"RR Basheer","year":"2024","unstructured":"Basheer RR, Hasanain FA, Abuelenain DA. Evaluating flexure properties, hardness, roughness and microleakage of high-strength injectable dental composite: an in vitro study. BMC Oral Health. 2024;24(1):546.","journal-title":"BMC Oral Health"},{"issue":"2","key":"8494_CR41","doi-asserted-by":"publisher","first-page":"173","DOI":"10.54589\/aol.34\/2\/173","volume":"34","author":"FM Fran\u00e7a","year":"2021","unstructured":"Fran\u00e7a FM, et al. Low-and high-viscosity bulk-fill resin composites. Acta Odontol\u00f3gica Latinoam. 2021;34(2):173\u201382.","journal-title":"Acta Odontol\u00f3gica Latinoam"},{"key":"8494_CR42","doi-asserted-by":"publisher","first-page":"105289","DOI":"10.1016\/j.jdent.2024.105289","volume":"149","author":"\u00d6 Hatipo\u011flu","year":"2024","unstructured":"Hatipo\u011flu \u00d6, Par M, Pertek F, Hatipo\u011flu. Comparison of degree of conversion performance of bulk-fill resin composites: A systematic review and network meta-analysis of in vitro studies. J Dent. 2024;149:105289.","journal-title":"J Dent"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-08494-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-08494-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-08494-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T06:38:40Z","timestamp":1784183920000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-08494-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,30]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["8494"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-08494-1","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,30]]},"assertion":[{"value":"28 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable. This in vitro study did not involve human participants or animal subjects; therefore, ethical approval was not required.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"1272"}}