{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T00:25:28Z","timestamp":1787099128135,"version":"build-2736575974"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T00:00:00Z","timestamp":1781222400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T00:00:00Z","timestamp":1787097600000},"content-version":"vor","delay-in-days":68,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"DOI":"10.1186\/s12903-026-08878-3","type":"journal-article","created":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T12:34:59Z","timestamp":1781267699000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Balancing radiopacity and artifact generation: a quantitative evaluation of CBCT artifacts induced by resin-based restorative materials"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3266-7657","authenticated-orcid":false,"given":"\u0130kbal Esra","family":"Pehlivan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6306-3901","authenticated-orcid":false,"given":"Sema","family":"Kaya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9984-6900","authenticated-orcid":false,"given":"Alaettin","family":"Ko\u00e7","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,12]]},"reference":[{"key":"8878_CR1","volume-title":"The selection of patients for dental radiographic examinations","author":"American Dental Association; U.S. Department of Health and Human Services","year":"2004","unstructured":"American Dental Association; U.S. Department of Health and Human Services. The selection of patients for dental radiographic examinations. Chicago, IL: American Dental Association; 2004."},{"key":"8878_CR2","first-page":"75","volume":"72","author":"WC Scarfe","year":"2006","unstructured":"Scarfe WC, Farman AG, Sukovic P. Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc. 2006;72:75\u201380.","journal-title":"J Can Dent Assoc"},{"key":"8878_CR3","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1259\/dmfr\/27403192","volume":"33","author":"K Tsiklakis","year":"2004","unstructured":"Tsiklakis K, Syriopoulos K, Stamatakis HC. Radiographic examination of the temporomandibular joint using cone-beam computed tomography. Dentomaxillofac Radiol. 2004;33:196\u2013201.","journal-title":"Dentomaxillofac Radiol"},{"key":"8878_CR4","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/j.ejrad.2005.05.011","volume":"56","author":"K Tsiklakis","year":"2005","unstructured":"Tsiklakis K, Donta C, Gavala S, Karayianni K, Kamenopoulou V, Hourdakis CJ. Dose reduction in maxillofacial imaging using low-dose cone-beam CT. Eur J Radiol. 2005;56:413\u20137.","journal-title":"Eur J Radiol"},{"key":"8878_CR5","doi-asserted-by":"publisher","first-page":"964","DOI":"10.1016\/j.ijom.2009.06.007","volume":"38","author":"H Ghaeminia","year":"2009","unstructured":"Ghaeminia H, Meijer GJ, Soehardi A, Borstlap WA, Mulder J, Berg\u00e9 SJ. Position of the impacted third molar in relation to the mandibular canal: diagnostic accuracy of cone-beam computed tomography compared with panoramic radiography. Int J Oral Maxillofac Surg. 2009;38:964\u201371.","journal-title":"Int J Oral Maxillofac Surg"},{"key":"8878_CR6","first-page":"217","volume":"44","author":"Q Chen","year":"2009","unstructured":"Chen Q, Liu DG, Zhang G, Ma XC. Relationship between the impacted mandibular third molar and the mandibular canal on panoramic radiograph and cone-beam computed tomography [in Chinese]. Zhonghua Kou Qiang Yi Xue Za Zhi. 2009;44:217\u201321.","journal-title":"Zhonghua Kou Qiang Yi Xue Za Zhi"},{"key":"8878_CR7","unstructured":"Harorl\u0131 A, Akg\u00fcl HM, Da\u011f\u0131stan S. Di\u015f hekimli\u011fi radyolojisi. 1st ed. Erzurum: Atat\u00fcrk \u00dcniversitesi Yay\u0131nlar\u0131; 2006:325\u20137."},{"key":"8878_CR8","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1016\/j.cden.2008.05.005","volume":"52","author":"WC Scarfe","year":"2008","unstructured":"Scarfe WC, Farman AG. What is cone-beam CT and how does it work? Dent Clin North Am. 2008;52:707\u201330.","journal-title":"Dent Clin North Am"},{"key":"8878_CR9","first-page":"113","volume":"24","author":"ET Erta\u015f","year":"2014","unstructured":"Erta\u015f ET, Arslan H, \u00c7apar \u0130D, G\u00f6k T, Erta\u015f H. Endodontide konik \u0131\u015f\u0131nl\u0131 bilgisayarl\u0131 tomografi. Atat\u00fcrk Univ Di\u015f Hek Fak Derg. 2014;24:113\u20138.","journal-title":"Atat\u00fcrk Univ Di\u015f Hek Fak Derg"},{"key":"8878_CR10","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1016\/j.mehy.2010.07.046","volume":"75","author":"T Hanzelka","year":"2010","unstructured":"Hanzelka T, Foltan R, Horka E, Sedy J. Reduction of the negative influence of patient motion on quality of CBCT scan. Med Hypotheses. 2010;75:610\u20132.","journal-title":"Med Hypotheses"},{"key":"8878_CR11","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1259\/dmfr\/30642039","volume":"40","author":"R Schulze","year":"2011","unstructured":"Schulze R, Heil U, Gross D, Bruellmann DD, Dranischnikow E, Schwanecke U, et al. Artefacts in CBCT: a review. Dentomaxillofac Radiol. 2011;40:265\u201373.","journal-title":"Dentomaxillofac Radiol"},{"key":"8878_CR12","first-page":"225","volume-title":"Oral Radiology: Principles and Interpretation","author":"WC Scarfe","year":"2009","unstructured":"Scarfe WC, Farman AG. Cone-beam computed tomography. In: White SC, Pharoah MJ, editors. Oral Radiology: Principles and Interpretation. 6th ed. St Louis: Elsevier; 2009. pp. 225\u201343.","edition":"6"},{"key":"8878_CR13","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1109\/23.775600","volume":"46","author":"B De Man","year":"1999","unstructured":"De Man B, Nuyts J, Dupont P, Marchal G, Suetens P. Metal streak artifacts in X-ray computed tomography: a simulation study. IEEE Trans Nucl Sci. 1999;46:691\u20136.","journal-title":"IEEE Trans Nucl Sci"},{"key":"8878_CR14","doi-asserted-by":"publisher","first-page":"1222","DOI":"10.1111\/clr.12438","volume":"26","author":"M Sancho-Puchades","year":"2015","unstructured":"Sancho-Puchades M, H\u00e4mmerle CH, Benic GI. In vitro assessment of artifacts induced by titanium, titanium-zirconium and zirconium dioxide implants in cone-beam computed tomography. Clin Oral Implants Res. 2015;26:1222\u20138.","journal-title":"Clin Oral Implants Res"},{"key":"8878_CR15","doi-asserted-by":"publisher","first-page":"e31766","DOI":"10.1371\/journal.pone.0031766","volume":"7","author":"T Klinke","year":"2012","unstructured":"Klinke T, Daboul A, Maron J, Gredes T, Puls R, Jaghsi A, et al. Artifacts in magnetic resonance imaging and computed tomography caused by dental materials. PLoS ONE. 2012;7:e31766.","journal-title":"PLoS ONE"},{"key":"8878_CR16","doi-asserted-by":"publisher","first-page":"1509","DOI":"10.1111\/clr.13019","volume":"28","author":"M Codari","year":"2017","unstructured":"Codari M, de Faria Vasconcelos K, Ferreira Pinheiro Nicolielo L, Haiter Neto F, Jacobs R. Quantitative evaluation of metal artifacts using different CBCT devices, high-density materials and field of views. Clin Oral Implants Res. 2017;28:1509\u201314.","journal-title":"Clin Oral Implants Res"},{"key":"8878_CR17","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.oooo.2016.10.021","volume":"123","author":"TV Vasconcelos","year":"2017","unstructured":"Vasconcelos TV, Bechara BB, McMahan CA, Freitas DQ, Noujeim M. Evaluation of artifacts generated by zirconium implants in cone-beam computed tomography images. Oral Surg Oral Med Oral Pathol Oral Radiol. 2017;123:265\u201372.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"key":"8878_CR18","doi-asserted-by":"publisher","first-page":"20140157","DOI":"10.1259\/dmfr.20140157","volume":"44","author":"N Kuusisto","year":"2015","unstructured":"Kuusisto N, Vallittu PK, Lassila LVJ, Huumonen S. Evaluation of intensity of artefacts in CBCT by radio-opacity of composite simulation models of implants in vitro. Dentomaxillofac Radiol. 2015;44:20140157.","journal-title":"Dentomaxillofac Radiol"},{"key":"8878_CR19","doi-asserted-by":"publisher","first-page":"401","DOI":"10.4103\/jiaomr.jiaomr_136_21","volume":"33","author":"L Ghorai","year":"2021","unstructured":"Ghorai L, Asha ML, Raja JV. Assessment of artifacts induced by various dental restorative materials on cone-beam computed tomography: an in vitro study. J Indian Acad Oral Med Radiol. 2021;33:401\u20138.","journal-title":"J Indian Acad Oral Med Radiol"},{"key":"8878_CR20","first-page":"989","volume":"45","author":"FS Yuan","year":"2013","unstructured":"Yuan FS, Sun YC, Xie XY, Wang Y, Lv PJ. Quantitative assessment on artifacts of dental restorative materials in cone-beam computed tomography. Beijing Da Xue Xue Bao Yi Xue Ban. 2013;45:989\u201392.","journal-title":"Beijing Da Xue Xue Bao Yi Xue Ban"},{"key":"8878_CR21","doi-asserted-by":"publisher","first-page":"267","DOI":"10.17219\/dmp\/93569","volume":"55","author":"P Hadadi","year":"2018","unstructured":"Hadadi P, Ostovarrad F, Nikbin A, Ranjzad H, Ghasemi F, Nemati S. Evaluation of the gray level of restorative materials using cone-beam computed tomography: a cross-sectional study. Dent Med Probl. 2018;55:267\u201374.","journal-title":"Dent Med Probl"},{"key":"8878_CR22","doi-asserted-by":"publisher","first-page":"436","DOI":"10.2341\/09-340-L","volume":"35","author":"Z Erg\u00fcc\u00fc","year":"2010","unstructured":"Erg\u00fcc\u00fc Z, T\u00fcrk\u00fcn LS, \u00d6nem E, G\u00fcneri P. Comparative radiopacity of six flowable resin composites. Oper Dent. 2010;35:436\u201340.","journal-title":"Oper Dent"},{"key":"8878_CR23","doi-asserted-by":"publisher","first-page":"292","DOI":"10.4236\/ojst.2013.35049","volume":"3","author":"PP Jaju","year":"2013","unstructured":"Jaju PP, Jain M, Singh A, Gupta A. Artefacts in cone-beam CT. Open J Stomatol. 2013;3:292\u20138.","journal-title":"Open J Stomatol"},{"key":"8878_CR24","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1016\/j.oooo.2016.11.008","volume":"123","author":"F Cebe","year":"2017","unstructured":"Cebe F, Aktan AM, Ozsevik AS, Ciftci ME, Surmelioglu HD. The effects of different restorative materials on the detection of approximal caries in cone-beam computed tomography scans with and without metal artifact reduction mode. Oral Surg Oral Med Oral Pathol Oral Radiol. 2017;123:392\u2013400.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"key":"8878_CR25","doi-asserted-by":"publisher","first-page":"245","DOI":"10.5624\/isd.2018.48.4.245","volume":"48","author":"A Nikbin","year":"2018","unstructured":"Nikbin A, Kajan ZD, Taramsari M, Khosravifard N. Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: an in vitro study. Imaging Sci Dent. 2018;48:245\u201354.","journal-title":"Imaging Sci Dent"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-08878-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-08878-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-08878-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T23:46:42Z","timestamp":1787096802000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-08878-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,12]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["8878"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-08878-3","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,12]]},"assertion":[{"value":"18 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This in vitro study was approved by the Non-Interventional Clinical Research Ethics Committee of Van Y\u00fcz\u00fcnc\u00fc Y\u0131l University, Van, T\u00fcrkiye (Approval No: 2025\/02\u201312), and was conducted in accordance with the principles of the Declaration of Helsinki. The study did not involve living human participants, identifiable personal data, or newly collected human biological samples. A non-identifiable dry human mandible was used only as a standardized positioning model for CBCT acquisition. Therefore, the ethics committee waived the requirement for informed consent to participate.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":4,"name":"Ethics","label":"Clinical trial number","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"1511"}}