{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T17:18:47Z","timestamp":1783358327028,"version":"3.54.6"},"reference-count":74,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T00:00:00Z","timestamp":1782777600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T00:00:00Z","timestamp":1783296000000},"content-version":"vor","delay-in-days":6,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100012533","name":"Minia University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100012533","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Recently, conservative approaches in prosthodontics have gained attention, especially with the use of endocrowns that preserve tooth structure and utilize retention through the pulp chamber.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aim of the study<\/jats:title>\n                    <jats:p>This study was conducted to evaluate the effect of modifying endocrown preparation design on retention and microleakage using Vita Enamic blocks in mandibular premolars.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Forty sound human mandibular premolars were treated endodontically and divided into two equal groups (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200920) according to preparation design: group1: conventional design, and group2: with added buccal groove design. Then each group was further subdivided into 2 equal subgroups (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200910) according to intra-radicular extension: subgroup A: 3\u00a0mm; subgroup B: 5\u00a0mm intraradicular extensions. Each subgroup was further subdivided randomly into 2 classes (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20095) according to the testing procedure. One class (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20095) was subjected to a retention test using a universal testing machine. The other class (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20095) was subjected to microleakage testing by soaking in 2% methylene blue in an incubator at room temperature for 24\u00a0h. All samples were assessed using a digital microscope to evaluate the extent of dye penetration and modes of failure.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Retention testing revealed no statistically significant difference between the two preparation designs within both intraradicular extension subgroups. However, increased intra-radicular extension 5\u00a0mm significantly enhanced retention compared to 3\u00a0mm in both designs (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). Regarding microleakage, the buccal groove design showed significantly lower values than the conventional design in both subgroups (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.015 and\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001, respectively). A significant difference between the two extensions was observed in the conventional group only, with higher microleakage in the 3\u00a0mm subgroup (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), while no significant difference was found in the buccal groove group (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.189).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>5\u00a0mm intra-radicular extension significantly improved the retention of the endocrowns, performing better than 3\u00a0mm, while the buccal groove design enhanced retention and resulted in lower microleakage.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-026-09023-w","type":"journal-article","created":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T02:44:56Z","timestamp":1782787496000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Effect of endocrown design modification on retention &amp; microleakage: an in vitro study"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-3685-2619","authenticated-orcid":false,"given":"Zina Ali Mohamed","family":"Anwar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cherif Adel","family":"Mohsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rasha Sayed","family":"Asaad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,30]]},"reference":[{"issue":"4","key":"9023_CR1","doi-asserted-by":"publisher","first-page":"246","DOI":"10.4103\/0972-0707.73382","volume":"13","author":"AP Tikku","year":"2010","unstructured":"Tikku AP, Chandra A, Bharti R. Are full cast crowns mandatory after endodontic treatment in posterior teeth? J Conservative Dentistry. 2010;13(4):246\u20138.","journal-title":"J Conservative Dentistry"},{"issue":"9","key":"9023_CR2","first-page":"733","volume":"38","author":"D Dietschi","year":"2007","unstructured":"Dietschi D, Duc O, Krejci I, Sadan A. Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature\u2014part 1: composition and micro- and macrostructure alterations. Quintessence Int. 2007;38(9):733\u201343.","journal-title":"Quintessence Int"},{"issue":"2","key":"9023_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jdent.2017.04.009","volume":"63","author":"MM Belleflamme","year":"2017","unstructured":"Belleflamme MM. No post-no core approach to restore severely damaged posterior teeth: An up-to-10-year retrospective study of documented endocrown cases. J Dent. 2017;63(2):1\u20137.","journal-title":"J Dent"},{"issue":"2","key":"9023_CR4","doi-asserted-by":"publisher","first-page":"57","DOI":"10.17096\/jiufd.71363","volume":"49","author":"G Sevimli","year":"2015","unstructured":"Sevimli G, Cengiz S, Oruc MS. Endocrowns: review. J Istanbul Univ Fac Dentistry. 2015;49(2):57\u201363.","journal-title":"J Istanbul Univ Fac Dentistry"},{"issue":"2","key":"9023_CR5","doi-asserted-by":"publisher","first-page":"97","DOI":"10.5005\/jp-journals-10047-0046","volume":"2","author":"SMJ Vinola","year":"2017","unstructured":"Vinola SMJ, Balasubramanian S, Mahalaxmi S. Endocrown \u2013 An Effective Viable Aesthetic Option for Expurgated Endodontically Treated Teeth: Two Case Reports. J Operative Dentistry Endodontics. 2017;2(2):97\u2013102.","journal-title":"J Operative Dentistry Endodontics"},{"key":"9023_CR6","first-page":"1","volume":"79","author":"M Fages","year":"2013","unstructured":"Fages M, Bennasar B. The Endocrown: A Different Type of All-Ceramic Reconstruction for Molars. J Can Dent Assoc. 2013;79:1\u201310.","journal-title":"J Can Dent Assoc"},{"issue":"4","key":"9023_CR7","doi-asserted-by":"publisher","first-page":"422","DOI":"10.5005\/jp-journals-10024-3075","volume":"22","author":"D Papalexopoulos","year":"2021","unstructured":"Papalexopoulos D, Samartzi TK, Sarafianou A. A Thorough Analysis of the Endocrown Restoration: A Literature Review. J Contemp Dent Pract. 2021;22(4):422\u20136.","journal-title":"J Contemp Dent Pract"},{"issue":"6","key":"9023_CR8","doi-asserted-by":"publisher","first-page":"489","DOI":"10.4047\/jap.2016.8.6.489","volume":"8","author":"J Guo","year":"2016","unstructured":"Guo J, Wang Z, Li X, Sun C, Gao E, Li H. A comparison of the fracture resistances of endodontically treated mandibular premolars restored with endocrowns and glass fiber post-core retained conventional crowns. J Adv Prosthodont. 2016;8(6):489\u201393.","journal-title":"J Adv Prosthodont"},{"issue":"1","key":"9023_CR9","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1016\/j.jdsr.2020.10.002","volume":"56","author":"S Miura","year":"2020","unstructured":"Miura S, Fujisawa M. Current status and perspective of CAD\/CAM-produced resin composite crowns: a review of clinical effectiveness. Japanese Dent Sci Rev. 2020;56(1):184\u20139.","journal-title":"Japanese Dent Sci Rev"},{"issue":"2","key":"9023_CR10","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/j.jdent.2016.07.005","volume":"52","author":"JA Sedrez-Porto","year":"2016","unstructured":"Sedrez-Porto JA, Rosa WL, da Silva AF, M\u00fcnchow EA, Pereira-Cenci T. Endocrown restorations: a systematic review and meta-analysis. J Dent. 2016;52(2):8\u201314.","journal-title":"J Dent"},{"issue":"1","key":"9023_CR11","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/s13063-020-04506-9","volume":"21","author":"J Wang","year":"2020","unstructured":"Wang J. Clinical efficacy of ceramic versus resin-based composite endocrowns in Chinese adults: Study protocol for randomised controlled trial. Trials. 2020;21(1):2\u20138.","journal-title":"Trials"},{"issue":"1","key":"9023_CR12","first-page":"147","volume":"32","author":"MA de Carvalho","year":"2018","unstructured":"de Carvalho MA, Lazari PC, Gresnigt M, Del Bel Cury AA, Magne P. Current options concerning the endodontically treated teeth restoration with the adhesive approach. Brazilian Oral Res. 2018;32(1):147\u201358.","journal-title":"Brazilian Oral Res"},{"issue":"3","key":"9023_CR13","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.jpor.2017.11.003","volume":"62","author":"D Taha","year":"2018","unstructured":"Taha D, Spintzyka S, Schille C, Sabetb A, Wahsh M, Salah T. Fracture resistance and failure modes of polymer-infiltrated ceramic endocrown restorations with variations in margin design and occlusal thickness. J Prosthodontic Res. 2018;62(3):293\u20137.","journal-title":"J Prosthodontic Res"},{"key":"9023_CR14","doi-asserted-by":"publisher","first-page":"118","DOI":"10.2174\/1874210620130904003","volume":"7","author":"C Dirxen","year":"2013","unstructured":"Dirxen C, Blunck U, Preissner S. Clinical performance of a new biomimetic double network material. Open Dentistry J. 2013;7:118\u201340.","journal-title":"Open Dentistry J"},{"issue":"2","key":"9023_CR15","doi-asserted-by":"publisher","first-page":"256","DOI":"10.4012\/dmj.2017-035","volume":"37","author":"B Kanat-Erturk","year":"2018","unstructured":"Kanat-Erturk B, Saridag S, Koseler E, Helvacloglu D, Avcu E, Yildiran-Avcu Y. Fracture strengths of endocrown restorations fabricated with different preparation depths and CAD\/CAM materials. Dent Mater J. 2018;37(2):256\u201365.","journal-title":"Dent Mater J"},{"issue":"6","key":"9023_CR16","doi-asserted-by":"publisher","first-page":"607","DOI":"10.2341\/15-146-L","volume":"41","author":"MD Gaintantzopoulou","year":"2016","unstructured":"Gaintantzopoulou MD, El-Damanhoury HM. Effect of Preparation Depth on the Marginal and Internal Adaptation of Computer-aided Design\/Computer-assisted Manufacture Endocrowns. Oper Dent. 2016;41(6):607\u201316.","journal-title":"Oper Dent"},{"issue":"1","key":"9023_CR17","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.prosdent.2016.03.025","volume":"117","author":"Y Shin","year":"2017","unstructured":"Shin Y, Park S, Park JW, Kim KM, Park YB, Roh BD. Evaluation of the marginal and internal discrepancies of CAD-CAM endocrowns with different cavity depths: An in vitro study. J Prosthet Dent. 2017;117(1):109\u201315.","journal-title":"J Prosthet Dent"},{"issue":"1","key":"9023_CR18","first-page":"2","volume":"2024","author":"FR Ardekani","year":"2024","unstructured":"Ardekani FR, Neshandar Asli H, Musapoor N, Falahchai M. Comparison of Internal and Marginal Adaptation of Endocrowns at Different Depths Fabricated by the Digital and Conventional Impression Techniques: Internal and Marginal Fit of Endocrowns. Int Dentistry. 2024;2024(1):2\u20137.","journal-title":"Int Dentistry"},{"issue":"37","key":"9023_CR19","first-page":"2","volume":"19","author":"AS Mostafavi","year":"2022","unstructured":"Mostafavi AS, Allahyari S, Niakan S, Atri F. Effect of Preparation Design on Marginal Integrity and Fracture Resistance of Endocrowns: A Systematic Review. Front Dentistry. 2022;19(37):2\u201316.","journal-title":"Front Dentistry"},{"issue":"1","key":"9023_CR20","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1080\/26415275.2020.1801348","volume":"7","author":"WE Ghoul","year":"2020","unstructured":"Ghoul WE, \u00d6zcan M, Tribst JPM, Salameh Z. Fracture resistance, failure mode, and stress concentration in a modified endocrown design. Biomaterial Investigations Dentistry. 2020;7(1):110\u20139.","journal-title":"Biomaterial Investigations Dentistry"},{"key":"9023_CR21","doi-asserted-by":"publisher","first-page":"e943706","DOI":"10.12659\/MSM.943401","volume":"30","author":"ME Sayed","year":"2024","unstructured":"Sayed ME, Porwal A, Hamdi BA, Hurubi SY, Hakami AK, Hakami AJ, Dighriri AM, Jad YA, Alqahtani SM, Alsubaiy EF, Alfaifi MA, Altoman MS, Jokhadar HF, AlResayes SS. Impact of Auxiliary Features on Retention of Short Dental Crowns: An In-Vitro Analysis of Box and Groove Preparations. Med Sci Monit. 2024;30:e943706.","journal-title":"Med Sci Monit"},{"issue":"2","key":"9023_CR22","doi-asserted-by":"publisher","first-page":"95","DOI":"10.5005\/jp-journals-10029-1104","volume":"4","author":"RM Weed","year":"2010","unstructured":"Weed RM. A comparison of methods for increasing retention of complete veneer crowns. Int J Experimental Dent Sci. 2010;4(2):95\u20138.","journal-title":"Int J Experimental Dent Sci"},{"issue":"1","key":"9023_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12903-025-06586-y","volume":"25","author":"MG Altamimi","year":"2025","unstructured":"Altamimi MG, Mahallawi OE, Lukomska-Szymanska M, et al. The influence of cavity design on the mechanical behavior of endo-crown restorations: an ex-vivo study. BMC Oral Health. 2025;25(1):1\u201315.","journal-title":"BMC Oral Health"},{"issue":"12","key":"9023_CR24","first-page":"11","volume":"15","author":"DS AlDabeeb","year":"2023","unstructured":"AlDabeeb DS, Alakeel NS, Al Jfshar RM, Endocrowns. Indications, Preparation Techniques, and Material Selection. Cureus. 2023;15(12):11\u20137.","journal-title":"Cureus"},{"issue":"3","key":"9023_CR25","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1016\/j.prosdent.2019.04.009","volume":"123","author":"N Govare","year":"2020","unstructured":"Govare N, Contrepois M. Endocrowns: a systematic review. J Prosthet Dent. 2020;123(3):411\u20138.","journal-title":"J Prosthet Dent"},{"issue":"8","key":"9023_CR26","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3390\/app10082696","volume":"10","author":"SB Haralur","year":"2020","unstructured":"Haralur SB, Alamri AASB, Alshehri SA, Alzahrani DS, Alfarsi M. Influence of Occlusal Thickness and Radicular Extension on the Fracture Resistance of Premolar Endocrowns from Different All-Ceramic Materials. Appl Sci. 2020;10(8):2\u201312.","journal-title":"Appl Sci"},{"issue":"3","key":"9023_CR27","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/S1991-7902(09)60016-7","volume":"4","author":"CY Chang","year":"2009","unstructured":"Chang CY, Kuo JS, Lin YS, Chang YH. Fracture resistance and failure modes of CEREC endo-crowns and conventional post and core-supported CEREC crowns. J Dent Sci. 2009;4(3):110\u20137.","journal-title":"J Dent Sci"},{"issue":"1","key":"9023_CR28","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1111\/j.1600-0722.2009.00704.x","volume":"118","author":"CL Lin","year":"2010","unstructured":"Lin CL, Chang YH, Chang CY, Pai CA, Huang SF. Finite element and Weibull analyses to estimate failure risks in the ceramic endocrown and classical crown for endodontically treated maxillary premolars. Eur J Oral Sci. 2010;118(1):87\u201393.","journal-title":"Eur J Oral Sci"},{"issue":"3","key":"9023_CR29","first-page":"42","volume":"19","author":"SM Hassan","year":"2020","unstructured":"Hassan SM. Effect of Different Preparation Designs on the Fracture Resistance of IPS Emax CAD Endo-Crowns. Ain Shams Dent J. 2020;19(3):42\u20139.","journal-title":"Ain Shams Dent J"},{"issue":"1","key":"9023_CR30","doi-asserted-by":"publisher","first-page":"89","DOI":"10.2340\/biid.v12.44183","volume":"12","author":"MS Billoo","year":"2025","unstructured":"Billoo MS, Khan MAK, Khalid T, Kazmi SMR. Effect of storage medium of extracted human teeth on the result of in vitro studies - a scoping review. Biomaterials Invest Dentistry. 2025;12(1):89\u201396.","journal-title":"Biomaterials Invest Dentistry"},{"issue":"2","key":"9023_CR31","doi-asserted-by":"publisher","first-page":"262","DOI":"10.4103\/1305-7456.156848","volume":"9","author":"B Ayd\u0131n","year":"2015","unstructured":"Ayd\u0131n B, Pamir T, Baltaci A, Orman MN, Turk T. Effect of storage solutions on microhardness of crown enamel and dentin. Eur J Dentistry. 2015;9(2):262\u20136.","journal-title":"Eur J Dentistry"},{"issue":"4","key":"9023_CR32","doi-asserted-by":"publisher","first-page":"3229","DOI":"10.21608\/edj.2025.397417.3525","volume":"71","author":"D Ahmed","year":"2025","unstructured":"Ahmed D, Amgad S, Bakry A. Effect of Preparation Depth on Marginal Adaptation of Anterior Teeth Restored by Endocrowns and Post Retained Crowns (In-Vitro study). Egypt Dent J. 2025;71(4):3229\u201340.","journal-title":"Egypt Dent J"},{"issue":"2","key":"9023_CR33","doi-asserted-by":"publisher","first-page":"125","DOI":"10.4103\/JCD.JCD_337_16","volume":"21","author":"D Verma","year":"2018","unstructured":"Verma D, Taneja S, Kumari M. Efficacy of different irrigation regimes on the push-out bond strength of various resin-based sealers at different root levels: An in vitro study. J conservative Dentistry. 2018;21(2):125\u20139.","journal-title":"J conservative Dentistry"},{"issue":"3","key":"9023_CR34","doi-asserted-by":"publisher","first-page":"2917","DOI":"10.21608\/edj.2024.286438.3030","volume":"70","author":"A Youssef","year":"2024","unstructured":"Youssef A, Mahmoud E. Effect of root canal obturation using resin and bio-ceramic sealers on reinforcement of endodontically treated teeth. Egypt Dent J. 2024;70(3):2917\u201322.","journal-title":"Egypt Dent J"},{"issue":"2","key":"9023_CR35","doi-asserted-by":"publisher","first-page":"1907","DOI":"10.21608\/edj.2022.115126.1941","volume":"68","author":"R Ahmed","year":"2022","unstructured":"Ahmed R, Ahmed H. Fracture resistance of MOD cavities in maxillary premolar teeth restored with different restorative protocols: an in vitro study. Egypt Dent J. 2022;68(2):1907\u201316.","journal-title":"Egypt Dent J"},{"issue":"1","key":"9023_CR36","doi-asserted-by":"publisher","first-page":"563","DOI":"10.21608\/edj.2023.251584.2807","volume":"70","author":"AA Elhadary","year":"2024","unstructured":"Elhadary AA, Thabet A, Abofadle A, Noor M. Effect Of Divergence Angle And Intra-Pulpal Depth On Marginal Adaptation Of Endo-Crowns (In Vitro Study). Egypt Dent J. 2024;70(1):563\u20136.","journal-title":"Egypt Dent J"},{"issue":"2","key":"9023_CR37","doi-asserted-by":"publisher","first-page":"61","DOI":"10.4103\/tdj.tdj_26_21","volume":"19","author":"R Alassar","year":"2022","unstructured":"Alassar R, AbdelKafy H, Mohamed EA. Endocrowns as permanent restorations for endodontically treated permanent molars in young age: 2-year follow up. Tanta Dent J. 2022;19(2):61\u20137.","journal-title":"Tanta Dent J"},{"issue":"1","key":"9023_CR38","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-024-74538-7","volume":"14","author":"AI Taha","year":"2024","unstructured":"Taha AI, Saad AE. An in vitro evaluation of tensile strength of molar endocrown milled from various computer aided design and manufacturing materials. Sci Rep. 2024;14(1):1\u201310.","journal-title":"Sci Rep"},{"issue":"2","key":"9023_CR39","first-page":"679","volume":"65","author":"MT Kamal","year":"2019","unstructured":"Kamal MT, Mohsen CA, Moahmmed RM. Assessment of retention and microleakage of endocrowns constructed of two different materials. Egypt Dent J. 2019;65(2):679\u201385.","journal-title":"Egypt Dent J"},{"issue":"1","key":"9023_CR40","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.identj.2025.109310","volume":"76","author":"A Almualm","year":"2026","unstructured":"Almualm A, Husein AB, Elsahn NA, El-Damanhoury HM. Internal Fit and Bond Strength of Customised CAD\/CAM 3D-Printed and Milled Resin-Based Posts vs Relined Fibre Posts. Int Dent J. 2026;76(1):2\u201310.","journal-title":"Int Dent J"},{"issue":"4","key":"9023_CR41","first-page":"289","volume":"18","author":"M Peumans","year":"2016","unstructured":"Peumans M, Valjakova EB, De Munck J, Mishevska CB, Van Meerbeek B. Bonding Effectiveness of Luting Composites to Different CAD\/CAM Materials. J Adhesive Dentistry. 2016;18(4):289\u2013302.","journal-title":"J Adhesive Dentistry"},{"key":"9023_CR42","unstructured":"Rzanny A, G\u00f6bel R. In-Vitro Investigation of the Bond Strengths of Hybrid-Ceramic Blocks to Resin Cements. Test report for Shofu Dental GmbH. 2017; 2\u201311."},{"issue":"10","key":"9023_CR43","first-page":"51","volume":"21","author":"M Zohdy","year":"2022","unstructured":"Zohdy M, Nour MM, Abdel Rahim WA. Fracture Resistance of Ceramic Endocrown versus Ceramic Overlay with Resin Core in Endodontically Treated Teeth. J Dent Med Sci (IOSR-JDMS). 2022;21(10):51\u20136.","journal-title":"J Dent Med Sci (IOSR-JDMS)"},{"key":"9023_CR44","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1007\/s44190-023-0640-y","volume":"45","author":"D Hamdy","year":"2023","unstructured":"Hamdy D, Amend S, L\u00fccker S. Effect of conditioning on microtensile bond strength of universal adhesives to primary enamel. Oral prophylaxis Kinderzahnheilkunde. 2023;45:20\u20132.","journal-title":"Oral prophylaxis Kinderzahnheilkunde"},{"issue":"3","key":"9023_CR45","first-page":"215","volume":"28","author":"B Van Meerbeek","year":"2003","unstructured":"Van Meerbeek B, De Munck J, Yoshida Y, Inoue S, Vargas M, Vijay P, Van Landuyt K, Lambrechts P, Vanherle G. Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges. Oper Dent. 2003;28(3):215\u201335.","journal-title":"Oper Dent"},{"issue":"1","key":"9023_CR46","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.dental.2010.10.016","volume":"27","author":"DH Pashley","year":"2011","unstructured":"Pashley DH, Tay FR, Breschi L, Tj\u00e4derhane L, Carvalho RM, Carrilho M, Tezvergil-Mutluay A. State-of-the-art etch-and-rinse adhesives. Dent Mater. 2011;27(1):1\u201316.","journal-title":"Dent Mater"},{"issue":"2","key":"9023_CR47","doi-asserted-by":"publisher","first-page":"1493","DOI":"10.21608\/edj.2023.199395.2483","volume":"69","author":"A Shebl Kassem","year":"2023","unstructured":"Shebl Kassem A, Mohammad M, Abd Elhamid T. Fracture resistance of four different types of CAD\/CAM lithium disilicate endocrowns. Egypt Dent J. 2023;69(2):1493\u2013500.","journal-title":"Egypt Dent J"},{"issue":"4","key":"9023_CR48","doi-asserted-by":"publisher","first-page":"3793","DOI":"10.21608\/edj.2022.162266.2256","volume":"68","author":"H Nassar","year":"2022","unstructured":"Nassar H. Internal fit and marginal adaptation of CAD\/CAM lithium disilicate endocrowns fabricated with conventional impression and digital scanning protocols. An in vitro study. Egypt Dent J. 2022;68(4):3793\u2013808.","journal-title":"Egypt Dent J"},{"issue":"2","key":"9023_CR49","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1002\/jemt.23586","volume":"84","author":"G Sa\u011flam","year":"2021","unstructured":"Sa\u011flam G, Cengiz S, Karacaer \u00d6. Marginal adaptation and fracture strength of endocrowns manufactured with different restorative materials: SEM and mechanical evaluation. Microsc Res Tech. 2021;84(2):284\u201390.","journal-title":"Microsc Res Tech"},{"issue":"1","key":"9023_CR50","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.identj.2024.07.1216","volume":"75","author":"HA Mously","year":"2025","unstructured":"Mously HA, Naguib GH, Abougazia AO, Almabadi AA, Qutub OA, Hamed MT. Anterior Endocrowns as an Alternative to Core Crown Restorations: A Systematic Review. Int Dent J. 2025;75(1):59\u201374.","journal-title":"Int Dent J"},{"issue":"1","key":"9023_CR51","first-page":"23","volume":"2","author":"S Asgary","year":"2024","unstructured":"Asgary S. Ultraconservative Reattachment for Managing Complete Crown Fracture in an Endodontically Treated Tooth. J Endodontics Restor Dentistry. 2024;2(1):23\u20136.","journal-title":"J Endodontics Restor Dentistry"},{"issue":"15","key":"9023_CR52","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3390\/ma17153736","volume":"17","author":"E Caussin","year":"2024","unstructured":"Caussin E, Izart M, Ceinos R, Attal JP, Beres F, Fran\u00e7ois P. Advanced Material Strategy for Restoring Damaged Endodontically Treated Teeth: A Comprehensive Review. Materials. 2024;17(15):2\u201320.","journal-title":"Materials"},{"issue":"1","key":"9023_CR53","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1111\/jopr.13360","volume":"31","author":"MM Darwish","year":"2022","unstructured":"Darwish MM, El-Mowafy OM, Finer Y. Effect of internal grooves on the fracture resistance of endocrowns. J Prosthodont. 2022;31(1):65\u201371.","journal-title":"J Prosthodont"},{"issue":"2","key":"9023_CR54","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1177\/2320206819862062","volume":"10","author":"S Cinar","year":"2019","unstructured":"Cinar S, Altan B, Akgungor G. Comparison of Bond Strength of Monolithic CAD-CAM Materials to Resin Cement Using Different Surface Treatment Methods. J Adv Oral Res. 2019;10(2):120\u20137.","journal-title":"J Adv Oral Res"},{"issue":"4","key":"9023_CR55","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1111\/jerd.12396","volume":"30","author":"D Taha","year":"2018","unstructured":"Taha D, Spintzyk S, Sabet A, Wahsh M, Salah T. Assessment Of Marginal Adaptation And Fracture Resistance Of Endocrown Restorations Utilising Different Machinable Blocks Subjected To Thermomechanical Ageing. J Aesthetic Restor Dentistry. 2018;30(4):319\u201328.","journal-title":"J Aesthetic Restor Dentistry"},{"issue":"3","key":"9023_CR56","doi-asserted-by":"publisher","first-page":"e4151","DOI":"10.1016\/j.prosdent.2020.01.011","volume":"125","author":"RA Al-Dabbagh","year":"2021","unstructured":"Al-Dabbagh RA. Survival and success of endocrowns: A systematic review and meta-analysis. J Prosthet Dent. 2021;125(3):e4151\u20139.","journal-title":"J Prosthet Dent"},{"issue":"2","key":"9023_CR57","doi-asserted-by":"publisher","first-page":"130","DOI":"10.2341\/11-105-L","volume":"37","author":"GR Biacchi","year":"2012","unstructured":"Biacchi GR, Basting RT. Comparison of fracture strength of endocrowns and glass fibre post-retained conventional crowns. Oper Dent. 2012;37(2):130\u20136.","journal-title":"Oper Dent"},{"issue":"3","key":"9023_CR58","first-page":"2","volume":"2017","author":"L Gulec","year":"2017","unstructured":"Gulec L, Ulusoy N. Effect of endocrown restorations with different CAD\/CAM materials: 3D finite element and Weibull analyses. Biomed Res Int. 2017;2017(3):2\u201310.","journal-title":"Biomed Res Int"},{"issue":"3","key":"9023_CR59","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1002\/cre2.726","volume":"9","author":"S Jalali","year":"2023","unstructured":"Jalali S, Jalali H, Kharazi Fard MJ, Abdolrahmani A, Alikhasi M. The Effect Of Preparation Design On The Fracture Resistance And Adaptation Of The CEREC Ceramic Endocrowns. Clin Experimental Dent Res. 2023;9(3):518\u201325.","journal-title":"Clin Experimental Dent Res"},{"issue":"1","key":"9023_CR60","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3844\/crdsp.2023.1.7","volume":"14","author":"MA Wakwak","year":"2023","unstructured":"Wakwak MA, Adly KS, Abdelhady AA, Elmanakhly AR. Microleakage Assessment of CAD\/CAM Endo Crown Restorations (an in vitro Study). Curr Res Dentistry. 2023;14(1):2\u20137.","journal-title":"Curr Res Dentistry"},{"issue":"1","key":"9023_CR61","doi-asserted-by":"publisher","first-page":"421","DOI":"10.21608\/edj.2023.198133.2474","volume":"70","author":"K Mahgoub","year":"2023","unstructured":"Mahgoub K, Morsi T, Abofadle A, Mina R. Influence of Two Intrapulpal Depths on Fracture Resistance of Endocrowns Restoring Maxillary Premolar Teeth Using Zirconia Reinforced Lithium Disilicate (In Vitro study). Egypt Dent J. 2023;70(1):421\u20136.","journal-title":"Egypt Dent J"},{"issue":"7","key":"9023_CR62","doi-asserted-by":"publisher","first-page":"1179","DOI":"10.1016\/j.joen.2018.04.008","volume":"44","author":"NR Dartora","year":"2018","unstructured":"Dartora NR, De Conto Ferreira MB, Moris ICM, Braz\u00e3o EH, Spazin AO, Sousa-Neto MD, Gomes EA. Effect of intracoronal depth of teeth restored with endocrowns on fracture resistance: in vitro and 3-dimensional finite element analysis. J Endod. 2018;44(7):1179\u201385.","journal-title":"J Endod"},{"issue":"1","key":"9023_CR63","doi-asserted-by":"publisher","first-page":"1","DOI":"10.2334\/josnusd.22-0288","volume":"65","author":"DA Bozkurt","year":"2023","unstructured":"Bozkurt DA, Buyukerkmen EB, Terlemez A. Comparison of the pull-out bond strength of endodontically treated anterior teeth with monolithic zirconia endocrown and post-and-core crown restorations. J Oral Sci. 2023;65(1):1\u20135.","journal-title":"J Oral Sci"},{"issue":"1","key":"9023_CR64","first-page":"35","volume":"12","author":"AS Madani","year":"2023","unstructured":"Madani AS, Bagheri H, Jarahi N, Hosseini Zarch H, Ahmadi M. Effect of central cavity depth and ferrule on the mechanical retention of endo-crowns. J Dent Mater Techniques. 2023;12(1):35\u201342.","journal-title":"J Dent Mater Techniques"},{"issue":"2","key":"9023_CR65","doi-asserted-by":"publisher","first-page":"201","DOI":"10.2341\/13-143-L","volume":"40","author":"HM El-Damanhoury","year":"2015","unstructured":"El-Damanhoury HM, Haj-Ali RN, Platt JA. Fracture Resistance and Microleakage of Endocrowns Utilising Three CAD-CAM Blocks. Oper Dent. 2015;40(2):201\u201310.","journal-title":"Oper Dent"},{"issue":"11","key":"9023_CR66","doi-asserted-by":"publisher","first-page":"2","DOI":"10.5812\/ircmj.19611","volume":"17","author":"R Eftekhar Ashtiani","year":"2015","unstructured":"Eftekhar Ashtiani R, Farzaneh B, Azarsina M, Aghdashi F, Dehghani N, Afshari A, Mahshid M. Microleakage of Four Dental Cements in Metal Ceramic Restorations With Open Margins. Iran Red Crescent Med J. 2015;17(11):2\u20135.","journal-title":"Iran Red Crescent Med J"},{"issue":"4","key":"9023_CR67","doi-asserted-by":"publisher","first-page":"3601","DOI":"10.21608\/edj.2024.308043.3136","volume":"70","author":"MGA Hilaly","year":"2024","unstructured":"Hilaly MGA, Elguindy J, Hashem R. Assessment of Vertical Marginal Gap and Fracture Resistance of Tessera Anterior Endocrown with Two Different Extensions. Egypt Dent J. 2024;70(4):3601\u201311.","journal-title":"Egypt Dent J"},{"issue":"4","key":"9023_CR68","first-page":"2","volume":"175","author":"P Altinci","year":"2025","unstructured":"Altinci P, D\u00f6nmez MB, \u00c7akmak G, Al-Johani H, Kahveci \u00c7, Erkal D, Yilmaz B. Additively manufactured resin-based endocrowns: Effect of material type, margin configuration, and pulp chamber depth on fabrication trueness and fit. J Dent. 2025;175(4):2\u201312.","journal-title":"J Dent"},{"issue":"1","key":"9023_CR69","doi-asserted-by":"publisher","first-page":"6","DOI":"10.4103\/JDRNTRUHS.JDRNTRUHS_1_20","volume":"9","author":"K Sudha","year":"2020","unstructured":"Sudha K, Mohan TM, Aparna K, Yadav BS, Rani ES, Sowjanya DL. Comparative evaluation of microleakage of conventional crowns and endocrowns using a confocal laser scanning electron microscope \u2013 An in vitro study. J Dr NTR Univ Health Sci. 2020;9(1):6\u201311.","journal-title":"J Dr NTR Univ Health Sci"},{"issue":"1","key":"9023_CR70","first-page":"1","volume":"25","author":"MAMB Elagwany","year":"2025","unstructured":"Elagwany MAMB, Hamdy AM, Zohdy MM. Micro-CT evaluation of marginal discrepancies of endocrown-restored molars with different intrapulpal depths and materials of fabrication. (in vitro study). BioMed Cent Oral Health. 2025;25(1):1\u201311.","journal-title":"BioMed Cent Oral Health"},{"issue":"16","key":"9023_CR71","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3390\/ma12162528","volume":"12","author":"O Ghajghouj","year":"2019","unstructured":"Ghajghouj O, Ta\u015far-Faruk S. Evaluation Of Fracture Resistance And Microleakage Of Endocrowns With Different Intracoronal Depths And Restorative Materials Luted With Various Resin Cements. Materials. 2019;12(16):2\u201311.","journal-title":"Materials"},{"issue":"2","key":"9023_CR72","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.fdj.2017.05.001","volume":"3","author":"HA Darwish","year":"2017","unstructured":"Darwish HA, Morsi TS, El Dimeery AG. Internal fit of lithium disilicate and resin nano-ceramic endocrowns with different preparation designs. Future Dent J. 2017;3(2):67\u201372.","journal-title":"Future Dent J"},{"key":"9023_CR73","doi-asserted-by":"publisher","first-page":"e942649","DOI":"10.12659\/MSM.942649","volume":"29","author":"GS Alwadai","year":"2023","unstructured":"Alwadai GS, Al Moaleem MM, Daghrery AA, Albar NH, Daghriri AA, AlGhamdi MM, Ageel SE, Daghreeri FAA, Al-Amri TMA, Aridhi WH, Almnea RA, Alhendi KD. A Comparative Analysis of Marginal Adaptation Values between Lithium Disilicate Glass Ceramics and Zirconia-Reinforced Lithium Silicate Endocrowns: A Systematic Review of In Vitro Studies. Med Sci Monit. 2023;29:e942649\u20131. https:\/\/doi.org\/10.12659\/MSM.942649.","journal-title":"Med Sci Monit"},{"issue":"1","key":"9023_CR74","doi-asserted-by":"publisher","first-page":"31","DOI":"10.22271\/oral.2023.v9.i1a.1652","volume":"9","author":"JLC Zardoni","year":"2023","unstructured":"Zardoni JLC, Flores MA, De L, Fierro NC, Palencia PG. Indications for the Use of Endocrowns, Design and Selection of Materials: Literature Review. Int J Appl Dent Sci. 2023;9(1):31\u20134.","journal-title":"Int J Appl Dent Sci"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-09023-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-09023-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-09023-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T17:04:06Z","timestamp":1783357446000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-09023-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,30]]},"references-count":74,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["9023"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-09023-w","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,30]]},"assertion":[{"value":"15 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study received ethical approval from the Research Ethics Committee of the Faculty of Dentistry, Minia University, as documented in Meeting No. 97, Clause No. 751, on 30\/05\/2023. All methods were performed in accordance with the Declaration of Helsinki and the ethical guidelines adopted by the Research Ethics Committee of the Faculty of Dentistry, Minia University. No human participants were involved in the study. The need for informed consent was waived by the Ethics Committee of the Faculty of Dentistry, Minia University.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1190"}}