{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T10:36:56Z","timestamp":1787740616231,"version":"build-2784847793"},"reference-count":65,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T00:00:00Z","timestamp":1783123200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T00:00:00Z","timestamp":1783123200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"AlSalam University"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Computer aided designed\/ computer aided manufactured (CAD\/CAM) materials offer diverse options for prosthetic rehabilitations, yet correlation between materials\u2019 surface properties and aging through chewing simulation needs characterization. The aim of this study is to measure and evaluate the effect of three body wear on three CAD\/CAM materials (poly methylmethacrylate (PMMA), composite resin and polyether ether ketone (PEEK)) regarding their microhardness and surface roughness.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Seventy-two disc-shaped specimens (20\u2009\u00d7\u20096\u00a0mm) were fabricated (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200924\/ group) from PMMA (Yamahachi PMMA Disk), Nano-ceramic Composite (Grandio Blocs, VOCO), and PEEK (BioHPP, Bredent). Specimens were subjected to 120,000 chewing cycles in a chewing simulator using a 3-body wear protocol with a pumice slurry. Wear volume (mm\n                      <jats:sup>3<\/jats:sup>\n                      ) was measured digitally. Surface roughness (\u00b5m) and Vickers hardness (VHN) were evaluated twice: at baseline and within the wear facets post-simulation. Data were analyzed using Two-way and One-way ANOVA (\n                      <jats:italic>P<\/jats:italic>\n                      -value\u2009&lt;\u20090.05), and Pearson correlation was used to measure the relationship between properties.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      One-way ANOVA revealed a significant difference between material types (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.000*), with composite exhibiting the lowest mean volume loss (0.08 mm\n                      <jats:sup>3<\/jats:sup>\n                      ), significantly outperforming PEEK (0.23mm\n                      <jats:sup>3<\/jats:sup>\n                      ) and PMMA (0.55 mm\n                      <jats:sup>3<\/jats:sup>\n                      ). For surface roughness, a significant interaction was observed between material type and wear simulation (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.000*), while there was no significant interaction between them on surface hardness (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.89). Composite significantly outperformed PEEK and PMMA regarding all tested properties.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The 3-body wear simulation induced significantly different volumetric loss across all groups, with the magnitude of loss largely dependent on the material\u2019s specific composition and baseline hardness. In addition, the surface roughness and microhardness of three investigated materials were considerably impacted by three-body wear. PMMA have the lowest wear resistance, lowest microhardness, and the greatest surface roughness both before and after wear, while composites with high filler loading and high microhardness have the highest wear resistance followed by PEEK. After wear, the surface roughness of the composite is acceptable.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-026-09028-5","type":"journal-article","created":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T23:33:19Z","timestamp":1783121599000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Effect of three-body wear on the surface properties of different polymer-based CAD\/CAM dental restorative and prosthetic materials"],"prefix":"10.1186","volume":"26","author":[{"given":"Abdallah Fawzy","family":"Elsadany","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8722-4845","authenticated-orcid":false,"given":"Hesham Samy","family":"Borg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enas A.","family":"Elshenawy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,4]]},"reference":[{"key":"9028_CR1","doi-asserted-by":"publisher","first-page":"612","DOI":"10.2341\/13-108-L","volume":"39","author":"C D\u2019Arcangelo","year":"2014","unstructured":"D\u2019Arcangelo C, Vanini L, Rondoni GD, Pirani M, Vadini M, Gattone M, De Angelis F. Wear properties of a novel resin composite compared to human enamel and other restorative materials. Oper Dent. 2014;39:612\u20138.","journal-title":"Oper Dent"},{"key":"9028_CR2","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.dental.2005.03.009","volume":"22","author":"T Stober","year":"2006","unstructured":"Stober T, Lutz T, Gilde H, Rammelsberg P. Wear of resin denture teeth by two-body contact. Dent Mater. 2006;22:243\u20139.","journal-title":"Dent Mater"},{"key":"9028_CR3","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1016\/j.dental.2007.04.012","volume":"24","author":"M Ghazal","year":"2008","unstructured":"Ghazal M, Yang B, Ludwig K, Kern M. Two-body wear of resin and ceramic denture teeth in comparison to human enamel. Dent Mater. 2008;24:502\u20137.","journal-title":"Dent Mater"},{"key":"9028_CR4","doi-asserted-by":"publisher","first-page":"1839","DOI":"10.3390\/ma12111839","volume":"12","author":"B Gwon","year":"2019","unstructured":"Gwon B, Bae EB, Lee JJ, Cho WT, Bae HY, Choi JW, Huh JB. Wear characteristics of dental ceramic CAD\/CAM materials opposing various dental composite resins. Mater (Basel). 2019;12:1839.","journal-title":"Mater (Basel)"},{"key":"9028_CR5","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.jdsr.2017.11.002","volume":"54","author":"A Tsujimoto","year":"2018","unstructured":"Tsujimoto A, Barkmeier WW, Fischer NG, Nojiri K, Nagura Y, Takamizawa T, Latta MA, Miazaki M. Wear of resin composites: current insights into underlying mechanisms, evaluation methods and influential factors. Jpn Dent Sci Rev. 2018;54:76\u201387.","journal-title":"Jpn Dent Sci Rev"},{"key":"9028_CR6","doi-asserted-by":"publisher","first-page":"e101","DOI":"10.1016\/j.dental.2016.11.013","volume":"33","author":"SD Heintze","year":"2017","unstructured":"Heintze SD, Ilie N, Hickel R, Reis A, Loguercio A, Rousson V. Laboratory mechanical parameters of composite resins and their relation to fractures and wear in clinical trials-A systematic review. Dent Mater. 2017;33:e101\u201314.","journal-title":"Dent Mater"},{"issue":"4","key":"9028_CR7","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/j.jmbbm.2018.06.030","volume":"86","author":"A Grau","year":"2018","unstructured":"Grau A, Stawarczyk B, Roos M, Theelke B, Hampe R. Reliability of wear measurements of CAD-CAM restorative materials after artificial aging in a mastication simulator. J Mech Behav Biomed Mater. 2018;86(4):185\u201390.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"8","key":"9028_CR8","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1016\/j.dental.2006.02.004","volume":"22","author":"P Lambrechts","year":"2006","unstructured":"Lambrechts P, Debels E, Van Landuyt K, Peumans M, Van Meerbeek B. How to simulate wear? Overview of existing methods. Dent Mater. 2006;22(8):693\u2013701.","journal-title":"Dent Mater"},{"key":"9028_CR9","doi-asserted-by":"crossref","unstructured":"Dionysopoulos D, Gerasimidou O. Wear of contemporary dental composite resin restorations: a literature review. Restor Dent Endod. 2021;46(2):1\u201313.","DOI":"10.5395\/rde.2021.46.e18"},{"issue":"4","key":"9028_CR10","doi-asserted-by":"publisher","first-page":"380","DOI":"10.2341\/16-206-L","volume":"43","author":"A Tsujimoto","year":"2018","unstructured":"Tsujimoto A, Barkmeier W, Takamizawa T, Latta M, Miyazaki M. Influence of thermal stress on simulated localized and generalized wear of nanofilled resin composites. Operat Dent. 2018;43(4):380\u201390.","journal-title":"Operat Dent"},{"issue":"1","key":"9028_CR11","doi-asserted-by":"publisher","first-page":"101","DOI":"10.2341\/16-046-L","volume":"42","author":"A Tsujimoto","year":"2017","unstructured":"Tsujimoto A, Barkmeier W, Takamizawa T, Latta M, Miyazaki M. Influence of thermal cycling on flexural properties and simulated wear of computer aided design\/computer-aided manufacturing resin composites. Operat Dent. 2017;42(1):101\u201310.","journal-title":"Operat Dent"},{"issue":"4","key":"9028_CR12","doi-asserted-by":"publisher","first-page":"495","DOI":"10.4012\/dmj.2014-293","volume":"34","author":"S Lauvahutanon","year":"2015","unstructured":"Lauvahutanon S, Takahashi H, Oki M, Arksornnukit M, Kanehira M, Finger W, CAM. Dent Mater J. 2015;34(4):495\u2013502.","journal-title":"Dent Mater J"},{"issue":"3","key":"9028_CR13","doi-asserted-by":"publisher","first-page":"237","DOI":"10.4103\/0972-0707.97946","volume":"15","author":"C Poggio","year":"2012","unstructured":"Poggio C, Lombardini M, Gaviati S, Chiesa M. Evaluation of Vickers hardness and depth of cure of six composite resins photo-activated with different polymerization modes. J Conserv Dent. 2012;15(3):237\u201324.","journal-title":"J Conserv Dent"},{"issue":"10s","key":"9028_CR14","first-page":"11","volume":"11","author":"M Zafar","year":"2014","unstructured":"Zafar M, Ahmed N. Effects of wear on hardness and stiffness of restorative dental materials. Life Sci J. 2014;11(10s):11\u20138.","journal-title":"Life Sci J"},{"issue":"8","key":"9028_CR15","doi-asserted-by":"publisher","first-page":"2297","DOI":"10.1002\/jbm.b.32801","volume":"100B","author":"R DeLong","year":"2012","unstructured":"DeLong R, Pintado MR, Douglas WH, Fok AS, Wilder AD, Swift EJ, Bayne SC. Wear of a dental composite in an artificial oral environment: A clinical correlation. J Biomed Mater Res B Appl Biomater. 2012;100B(8):2297\u2013306.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"issue":"5","key":"9028_CR16","first-page":"628","volume":"28","author":"E Say","year":"2003","unstructured":"Say E, Civelek A, Nobecourt A, Ersoy M, Guleryuz C. Wear and microhardness of different resin composite materials. Oper Dent. 2003;28(5):628\u201334.","journal-title":"Oper Dent"},{"key":"9028_CR17","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s10856-006-0675-8","volume":"18","author":"A Kakaboura","year":"2007","unstructured":"Kakaboura A, Fragouli M, Rahiotis C, Silikas N. Evaluation of surface characteristics of dental composites using profilometry, scanning electron, atomic force microscopy and gloss-meter. J Mater Sci Mater Med. 2007;18:155\u201363.","journal-title":"J Mater Sci Mater Med"},{"key":"9028_CR18","doi-asserted-by":"publisher","first-page":"599","DOI":"10.2334\/josnusd.52.599","volume":"52","author":"Y Hosoya","year":"2010","unstructured":"Hosoya Y, Shiraishi T, Odatsu T, Ogata T, Miyazaki M, Powers JM. Effects of specular component and polishing on color of resin composites. J Oral Sci. 2010;52:599\u2013607.","journal-title":"J Oral Sci"},{"key":"9028_CR19","doi-asserted-by":"publisher","first-page":"185","DOI":"10.2341\/06-56","volume":"32","author":"Z Erg\u00fcc\u00fc","year":"2007","unstructured":"Erg\u00fcc\u00fc Z, T\u00fcrk\u00fcn LS. Surface roughness of novel resin composites polished with one-step systems. Oper Dent. 2007;32:185\u201392.","journal-title":"Oper Dent"},{"key":"9028_CR20","first-page":"60","volume":"22","author":"LM Cavalcante","year":"2009","unstructured":"Cavalcante LM, Masouras K, Watts DC, Pimenta LA, Silikas N. Effect of nanofillers size on surface properties after toothbrush abrasion. Am J Dent. 2009;22:60\u20134.","journal-title":"Am J Dent"},{"key":"9028_CR21","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1002\/jbm.b.30400","volume":"77","author":"L Musanje","year":"2006","unstructured":"Musanje L, Ferracane JL, Ferracane LL. Effects of resin formulation and nanofiller surface treatment on in vivo wear of experimental hybrid resin composite. J Biomed Mater Res B Appl Biomater. 2006;77:120\u201325.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"issue":"4","key":"9028_CR22","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1111\/jopr.12926","volume":"29","author":"ZN Al-Dwairi","year":"2020","unstructured":"Al-Dwairi ZN, Tahboub KY, Baba NZ, Goodacre CJ. A Comparison of the Flexural and Impact Strengths and Flexural Modulus of CAD\/CAM and Conventional Heat-Cured Polymethyl Methacrylate (PMMA). J Prosthodont. 2020;29(4):341\u201349.","journal-title":"J Prosthodont"},{"issue":"6","key":"9028_CR23","doi-asserted-by":"publisher","first-page":"1221","DOI":"10.1016\/j.prosdent.2021.03.018","volume":"128","author":"J Lim\u00edrio","year":"2022","unstructured":"Lim\u00edrio J, Gomes J, Rezende M, Lemos C, Rosa C, Pellizzer E. Mechanical properties of polymethyl methacrylate as a denture base: Conventional versus CAD-CAM resin - A systematic review and meta-analysis of in vitro studies. J Prosthet Dent. 2022;128(6):1221\u201329.","journal-title":"J Prosthet Dent"},{"key":"9028_CR24","first-page":"457","volume":"43","author":"D Edelhoff","year":"2012","unstructured":"Edelhoff D, Beuer F, Schweiger J, Brix O, Stimmelmayr M, G\u00fcth JF. CAD\/CAM generated high-density polymer restorations for the pretreatment of complex cases: a case report. Quintessence Int. 2012;43:457\u201367.","journal-title":"Quintessence Int"},{"issue":"8","key":"9028_CR25","doi-asserted-by":"publisher","first-page":"431","DOI":"10.3390\/jfb14080431","volume":"14","author":"I Rexhepi","year":"2023","unstructured":"Rexhepi I, Santilli M, D\u2019Addazio G, Tafuri G, Manciocchi E, Caputi S, Sinjari B. Clinical Applications and Mechanical Properties of CAD-CAM Materials in Restorative and Prosthetic Dentistry: A Systematic Review. J Funct Biomater. 2023;14(8):431.","journal-title":"J Funct Biomater"},{"issue":"3","key":"9028_CR26","doi-asserted-by":"publisher","first-page":"562","DOI":"10.3390\/ma18030562","volume":"18","author":"L Garza","year":"2025","unstructured":"Garza L, Crooke E, Vall\u00e9s M, Soliva J, Rodr\u00edguez X, Rodeja M, Miguel Roig. Evaluation of Polymethyl Methacrylate as a Provisional Material in a Fully Digital Workflow for Immediate-Load Complete-Arch Implant-Supported Prostheses over Three Months. Materials. 2025;18(3):562.","journal-title":"Materials"},{"key":"9028_CR27","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.prosdent.2021.04.025","volume":"129","author":"K Angelara","year":"2023","unstructured":"Angelara K, Bratos M, Sorensen J. Comparison of strength of milled and conventionally processed PMMA complete-arch implant-supported immediate interim fixed dental prostheses. J Prosthet Dent. 2023;129:221\u201327.","journal-title":"J Prosthet Dent"},{"key":"9028_CR28","doi-asserted-by":"publisher","first-page":"377","DOI":"10.4012\/dmj.2011-238","volume":"31","author":"B Stawarczyk","year":"2012","unstructured":"Stawarczyk B, Sener B, Trottmann A, Roos M, \u00d6zcan M, H\u00e4mmerle CH. Discoloration of manually fabricated resins and industrially fabricated CAD\/CAM blocks versus glass-ceramic: effect of storage media, duration, and subsequent polishing. Dent Mater J. 2012;31:377\u201383.","journal-title":"Dent Mater J"},{"issue":"9","key":"9028_CR29","first-page":"1094","volume":"20","author":"M Vohra","year":"2024","unstructured":"Vohra M, Wadhwani V, Khushali K. Comparative Evaluation of Two Body Wear of PEEK vs Milled PMMA vs Indirect Composite After Chewing Simulation- An In Vitro Study. Nanatechnol Perceptions. 2024;20(9):1094\u2013101.","journal-title":"Nanatechnol Perceptions"},{"issue":"5","key":"9028_CR30","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1016\/j.dental.2022.04.016","volume":"38","author":"E Maier","year":"2022","unstructured":"Maier E, Grottschreiber C, Knepper I, Opdam N, Petschelt A, Loomans B, Lohbauer U. Evaluation of wear behavior of dental restorative materials against zirconia in vitro. Dent Mater. 2022;38(5):778\u201388.","journal-title":"Dent Mater"},{"issue":"3","key":"9028_CR31","doi-asserted-by":"publisher","first-page":"343","DOI":"10.4012\/dmj.2018-140","volume":"38","author":"SD Heintze","year":"2019","unstructured":"Heintze SD, Reichl FX, Hickel R. Wear of dental materials: clinical significance and laboratory wear simulation methods \u2013 a review. Dent Mater J. 2019;38(3):343\u201353.","journal-title":"Dent Mater J"},{"key":"9028_CR32","unstructured":"International Organization for Standardization. Dental materials \u2014 Guidance on testing of wear. Part 2: Wear by two- and\/or three body contact. 2001. ISO\/TS 14569-2:2001."},{"key":"9028_CR33","unstructured":"Standard Test Method for Microindentation Hardness of Materials. Denture-Based Polymer. ASTM International; 2017."},{"key":"9028_CR34","unstructured":"International Organization for Standardization. Geometrical Product Specification (GPS) - Surface Texture: Area - Part 2: Terms, Definitions, Surface Texture Parameters and Techniques. 2012; ISO25178:2012(2)."},{"key":"9028_CR35","doi-asserted-by":"crossref","unstructured":"Aver\u2019Yanova I, Bogomolov D, Poroshin V. ISO 25178 standard for three-dimensional parametric assessment of surface texture. Russ Eng Res. 2017;37(6):513\u20136.","DOI":"10.3103\/S1068798X17060053"},{"key":"9028_CR36","doi-asserted-by":"publisher","first-page":"103554","DOI":"10.1016\/j.jdent.2020.103554","volume":"105","author":"AM Kielbassa","year":"2021","unstructured":"Kielbassa AM, Oehme EP, Shakavets N, Wolgin M. In vitro wear of (resin-coated) high-viscosity glass ionomer cements and glass hybrid restorative systems. J Dent. 2021;105:103554.","journal-title":"J Dent"},{"issue":"12","key":"9028_CR37","doi-asserted-by":"publisher","first-page":"1261","DOI":"10.1016\/j.dental.2012.09.008","volume":"28","author":"N Koottathape","year":"2012","unstructured":"Koottathape N, Takahashi H, Iwasaki N, Kanehira M, Finger WJ. Two-and three-body wear of composite resins. Dent Mater. 2012;28(12):1261\u201370.","journal-title":"Dent Mater"},{"issue":"21","key":"9028_CR38","doi-asserted-by":"publisher","first-page":"3575","DOI":"10.3390\/ma12213575","volume":"12","author":"D Koletsi","year":"2019","unstructured":"Koletsi D, Iliadi A, Eliades T, Eliades G. Vitro Simulation and In Vivo Assessment of Tooth Wear: A Meta-Analysis of In Vitro and Clinical Research. Mater (Basel). 2019;12(21):3575.","journal-title":"Mater (Basel)"},{"issue":"5","key":"9028_CR39","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.1016\/j.prosdent.2014.05.006","volume":"112","author":"J Sripetchdanond","year":"2014","unstructured":"Sripetchdanond J, Leevailoj C. Wear of human enamel opposing monolithic zirconia, glass ceramic, and composite resin: an in vitro study. J Prosthet Dent. 2014;112(5):1141\u201350.","journal-title":"J Prosthet Dent"},{"issue":"6","key":"9028_CR40","doi-asserted-by":"publisher","first-page":"713","DOI":"10.4012\/dmj.2008-031","volume":"29","author":"T Shimane","year":"2010","unstructured":"Shimane T, Endo K, Zheng JH, Yanagi T, Ohno H. Wear of opposing teeth by posterior composite resins\u2013evaluation of newly developed wear test methods. Dent Mater J. 2010;29(6):713\u201320.","journal-title":"Dent Mater J"},{"key":"9028_CR41","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1111\/j.1875-595X.2002.tb00730.x","volume":"52","author":"J McCabe","year":"2002","unstructured":"McCabe J, Molyvda S, Rolland S, Rusby S, Carrick T. Two-and three-body wear of dental restorative materials. Int Dent J. 2002;52:406\u201316.","journal-title":"Int Dent J"},{"issue":"3","key":"9028_CR42","doi-asserted-by":"publisher","first-page":"2691","DOI":"10.21608\/edj.2022.135481.2091","volume":"68","author":"A Bekhiet","year":"2022","unstructured":"Bekhiet A, Katamish H, Salah T. The effect of two body wear on CAD\/CAM PEEK against Monolithic Zirconia, Lithium Disilicate, and Tooth Enamel; An in vitro study. Egypt Dent J. 2022;68(3):2691\u2013700.","journal-title":"Egypt Dent J"},{"key":"9028_CR43","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.jmbbm.2015.06.007","volume":"50","author":"BJ Chong","year":"2015","unstructured":"Chong BJ, Thangavel AK, Rolton SB, Guazzato M, Klineberg IJ. Clinical and laboratory surface finishing procedures for zirconia on opposing human enamel wear: A laboratory study. J Mech Behav Biomed Mater. 2015;50:93\u2013103.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"3","key":"9028_CR44","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/S0109-5641(01)00043-4","volume":"18","author":"AC Shortall","year":"2002","unstructured":"Shortall AC, Hu XQ, Marquis PM. Potential countersample materials for in vitro simulation wear testing. Dent Mat. 2002;18(3):246\u201354.","journal-title":"Dent Mat"},{"issue":"3","key":"9028_CR45","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1016\/j.prosdent.2015.03.007","volume":"114","author":"MM Rayyan","year":"2015","unstructured":"Rayyan MM, Aboushelib M, Sayed NM, Ibrahim A, Jimbo R. Comparison of interim restorations fabricated by CAD\/CAM with those fabricated manually. J Prosthet Dent. 2015;114(3):414\u20139.","journal-title":"J Prosthet Dent"},{"issue":"10","key":"9028_CR46","doi-asserted-by":"publisher","first-page":"1408","DOI":"10.1016\/j.dental.2019.07.023","volume":"35","author":"S O\u2019Toole","year":"2019","unstructured":"O\u2019Toole S, Osnes C, Bartlett D, Keeling A. Investigation into the validity of WearCompare, a purpose-built software to quantify erosive tooth wear progression. Dent Mater. 2019;35(10):1408\u201314.","journal-title":"Dent Mater"},{"issue":"2","key":"9028_CR47","doi-asserted-by":"publisher","first-page":"153","DOI":"10.2186\/jpr.JPR_D_23_00263","volume":"69","author":"BI Flores-Ferreyra","year":"2025","unstructured":"Flores-Ferreyra BI, Argueta-Figueroa L, Torres-Rosas R, Carrasco-Guti\u00e9rrez RG, Casillas-Santana MA. de Los Angeles Moyaho-Bernal M. Dental human enamel wear caused by ceramic antagonists: A systematic review and network meta-analysis. J Prosthodont Res. 2025;69(2):153\u201362.","journal-title":"J Prosthodont Res"},{"key":"9028_CR48","doi-asserted-by":"publisher","first-page":"104832","DOI":"10.1016\/j.jdent.2024.104832","volume":"142","author":"Z Mao","year":"2024","unstructured":"Mao Z, Beuer F, Hey J, Schmidt F, Sorensen JA, Prause E. Antagonist enamel tooth wear produced by different dental ceramic systems: A systematic review and network meta-analysis of controlled clinical trials. J Dent. 2024;142:104832.","journal-title":"J Dent"},{"issue":"12","key":"9028_CR49","doi-asserted-by":"publisher","first-page":"e1189","DOI":"10.4317\/jced.57279","volume":"12","author":"S Soriano-Valero","year":"2020","unstructured":"Soriano-Valero S, Rom\u00e1n-Rodriguez J-L, Agust\u00edn-Panadero R, Bellot-Arc\u00eds C, Fons-Font A, Fern\u00e1ndez-Estevan L. Systematic review of chewing simulators: Reality and reproducibility of in vitro studies. J Clin Exp Dent. 2020;12(12):e1189.","journal-title":"J Clin Exp Dent"},{"key":"9028_CR50","doi-asserted-by":"publisher","first-page":"107012","DOI":"10.1016\/j.jmbbm.2025.107012","volume":"168","author":"K Li","year":"2025","unstructured":"Li K, Meng M, Li C, Liu Y, Liu H, Bai S, Zhong S, Li M, Chen L, Tian M, Niu L, Fang M. Comparative study of wear properties of CAD\/CAM PEEK materials, resin ceramics and dental enamel under simulated chewing conditions. J Mech Behav Biomed Mater. 2025;168:107012.","journal-title":"J Mech Behav Biomed Mater"},{"key":"9028_CR51","doi-asserted-by":"crossref","unstructured":"Iyer RS, Suchitra SR, Hegde D, Coutinho CA, Priya A. BioHPP: Properties and Applications in Prosthodontics a review. J Res Dentistry. 2019;7(4):72\u20136 .","DOI":"10.19177\/jrd.v7e4201972-76"},{"issue":"5","key":"9028_CR52","first-page":"e85008","volume":"17","author":"B Singh","year":"2025","unstructured":"Singh B, Jain S, Bhasin N, Kaur J, Borse P, Longkumer P. Comparative Evaluation of Surface Roughness, Wettability, and Hardness of Conventional, Heat-Polymerized, Computer-Aided Designed and Milled, and Three-Dimensionally Printed Polymethyl Methacrylate Denture Base Resins: An In Vitro Study. Cureus. 2025;17(5):e85008.","journal-title":"Cureus"},{"issue":"14","key":"9028_CR53","doi-asserted-by":"publisher","first-page":"3518","DOI":"10.3390\/ma17143518","volume":"17","author":"BD Dejak","year":"2024","unstructured":"Dejak BD, Langot C, Krasowski M, Klich M. Evaluation of Hardness and Wear of Conventional and Transparent Zirconia Ceramics, Feldspathic Ceramic, Glaze, and Enamel. Materials. 2024;17(14):3518.","journal-title":"Materials"},{"key":"9028_CR54","doi-asserted-by":"publisher","first-page":"676","DOI":"10.3390\/polym17050676","volume":"17","author":"S Almuhayya","year":"2025","unstructured":"Almuhayya S, Alshahrani R, Alsania R, Albassam A, Alnemari H, Babaier R. Biofilm Formation on Three High-Performance Polymeric CAD\/CAM Composites: An In Vitro Study. Polymers. 2025;17:676.","journal-title":"Polymers"},{"key":"9028_CR55","doi-asserted-by":"publisher","first-page":"2140","DOI":"10.3390\/polym15092140","volume":"15","author":"S Vulovi\u00b4c","year":"2023","unstructured":"Vulovi\u00b4c S, Nikoli\u00b4c-Jakoba N, Radunovi\u00b4c M, Petrovi\u00b4c S, Popovac A, Todorovi\u00b4c M. Mili\u00b4c-Lemi\u00b4c A. Biofilm Formation on the Surfaces of CAD\/CAM Dental Polymers. Polymers. 2023;15:2140.","journal-title":"Polymers"},{"issue":"3","key":"9028_CR56","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1034\/j.1600-0501.1996.070302.x","volume":"7","author":"CM Bollen","year":"1996","unstructured":"Bollen CM, Papaioanno W, Van Eldere J, Schepers E, Quirynen M, van Steenberghe D. The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis. Clin Oral Implants Res. 1996;7(3):201\u201311.","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"9028_CR57","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1038\/sj.bdj.4810881","volume":"196","author":"CS Jones","year":"2004","unstructured":"Jones CS, Billington RW, Pearson GJ. The in vivo perception of roughness of restorations. Br Dent J. 2004;196(1):42\u20135.","journal-title":"Br Dent J"},{"issue":"6","key":"9028_CR58","doi-asserted-by":"publisher","first-page":"881","DOI":"10.4012\/dmj.2015-177","volume":"34","author":"H Koizumi","year":"2015","unstructured":"Koizumi H, Saiki O, Nogawa H, Hiraba H, Okazaki T, Matsumura H. Surface roughness and gloss of current CAD\/CAM resin composites before and after toothbrush abrasion. Dent Mater J. 2015;34(6):881\u20137.","journal-title":"Dent Mater J"},{"key":"9028_CR59","doi-asserted-by":"publisher","first-page":"1751","DOI":"10.1016\/j.jmbbm.2025.107012","volume":"168","author":"K Li","year":"2025","unstructured":"Li K, Meng M, Li C, Liu Y, Liu H, Bai S, Zhong S, Li M, Chen L, Tian M, Niu L. Ming Fang. Comparative study of wear properties of CAD\/CAM PEEK materials, resin ceramics and dental enamel under simulated chewing conditions. J Mech Behav Biomed Mater. 2025;168:1751\u20136161.","journal-title":"J Mech Behav Biomed Mater"},{"key":"9028_CR60","doi-asserted-by":"crossref","unstructured":"Kandula UKR, Monika D, Verma PC, Rathi A, Saravanan P. A Comprehensive Review on Manufacturing and Characterization of Polyetheretherketone Polymers for Dental Implant Applications. 3D Print Addit Manuf. 2024;11(4):1441\u201361.","DOI":"10.1089\/3dp.2023.0064"},{"issue":"2","key":"9028_CR61","doi-asserted-by":"publisher","first-page":"215","DOI":"10.2334\/josnusd.51.215","volume":"51","author":"M Murakami","year":"2009","unstructured":"Murakami M. Surface properties of an indirect composite polymerized with five laboratory light polymerization systems. J Oral Sci. 2009;51(2):215\u201321.","journal-title":"J Oral Sci"},{"issue":"4","key":"9028_CR62","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1067\/mpr.2001.114267","volume":"85","author":"MN Mandikos","year":"2001","unstructured":"Mandikos MN, McGivney GP, Davis E, Bush PJ, Carter JM. A comparison of the wear resistance and hardness of indirect composite resins. J Prosthet Dent. 2001;85(4):386\u201395.","journal-title":"J Prosthet Dent"},{"issue":"4","key":"9028_CR63","first-page":"1","volume":"3","author":"HF Hussain","year":"2020","unstructured":"Hussain HF, Hill RG, Gillam DG. Quantification of Tooth Wear by Selected Desensitizing Polishing Pastes Using White Light Profilometry. J Dent Maxillofacial Res. 2020;3(4):1\u20134.","journal-title":"J Dent Maxillofacial Res"},{"issue":"1","key":"9028_CR64","doi-asserted-by":"publisher","first-page":"74","DOI":"10.4012\/dmj.2023-071","volume":"43","author":"ET Bayraktar","year":"2024","unstructured":"Bayraktar ET, T\u00fcrkmen C, Atali PY, Tar\u00e7in B, Korkut B, Ya\u015fa B. In-vitro evaluation of wear characteristics, microhardness and color stability of dental restorative CAD\/CAM materials. Dent Mater J. 2024;43(1):74\u201383.","journal-title":"Dent Mater J"},{"key":"9028_CR65","unstructured":"Preis V, Weiser F, Handel G, Rosentritt M. Wear performance of monolithic dental ceramics with different surface treatments. Quintessence Int. 2013;44(5):393\u2013405."}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-09028-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-09028-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-09028-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T01:01:30Z","timestamp":1783126890000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-09028-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,4]]},"references-count":65,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["9028"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-09028-5","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,4]]},"assertion":[{"value":"12 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Approval for this research was obtained from Research Ethics Committee, Faculty of Dentistry, Alsalam University (Approval number: Sue 013010253).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1183"}}