{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T18:33:52Z","timestamp":1785522832851,"version":"3.56.0"},"reference-count":65,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T00:00:00Z","timestamp":1784678400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,27]],"date-time":"2026-07-27T00:00:00Z","timestamp":1785110400000},"content-version":"vor","delay-in-days":5,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Fayoum University"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aim of the study<\/jats:title>\n                    <jats:p>Utilizing Finite Element Analysis, this research biomechanically assessed three prosthetic designs for mandibular unilateral free-end saddle, specifically interrogating the magnitude and distribution of stresses transmitted to the terminal anterior abutment and the supporting posterior implant.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>A mandibular unilateral free-end saddle educational cast, with the first premolar as the last standing abutment tooth, was used. The abutment teeth of the free end saddle side were prepared to accommodate two splinted crowns. Then the cast was scanned, and an implant analogue was digitally inserted at the second molar area using Blender4dental software. Three different treatment modalities were digitally designed and collected using Blender4dental software, then grouped as follows: Group 1: Tooth-Implant supported fixed-fixed bridge. Group 2: OT vertical attachment retained removable bridge. Group 3: Double OT cap retained removable partial denture. The preparatory stage involved editing the STL file within the Meshmixer software environment. Subsequent finite element analysis FEA was performed using Abaqus, where specific occlusal loads were applied over the area to be examined: 200\u00a0N (vertical) and 23.5\u00a0N (tangential) on the molars, and 140\u00a0N (vertical) and 16.45\u00a0N (tangential) on the canines and premolars. The von Misses stress levels induced around the anterior abutments, at the residual ridge area, and around the implant were measured and compared.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Regarding the stresses exerted by the whole design, it was found that, the lowest stresses were found with design 3 (Double OT cap retained removable partial denture), while the highest stresses were found with design 2 (OT vertical attachment retained removable bridge). Regarding von-Mises stresses on the prepared abutments and the residual ridge, the lowest von Mises stresses were found in design 3, while the highest von Mises stresses were found in design 1 (Tooth-Implant supported fixed-fixed bridge). Regarding von-Mises stresses on the implant, the lowest Von Mises stresses were found in design 3, while the highest Von Mises stresses were found in design 2.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>RPD restored by double OT and ball and socket attachment exerted the least stress on the abutment, the residual ridge, and the implant; this design is recommended to be used with weak abutments, flat ridge, and\\ or with imperfect implant stability. The fixed bridge design showed the highest stresses exerted on the anterior abutments and the residual ridge due to the absence of resiliency between the crowns and the teeth. This design could be indicated with strong abutments and well-formed ridges. OT vertical attachment retained removable bridge design showed the highest stresses exerted on the posterior implant, carrying a slight torquing force, resulting in more load concentration on the implant compared to the other two designs.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-026-09173-x","type":"journal-article","created":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T13:45:05Z","timestamp":1784727905000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Stress distribution in different tooth-implant supported mandibular prostheses rehabilitating unilateral free-end saddle: a biomechanical comparative finite element study"],"prefix":"10.1186","volume":"26","author":[{"given":"Haitham Amr","family":"Mohammed","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maha Nagy Mohamed","family":"Kamal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdallah","family":"Shokry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,22]]},"reference":[{"issue":"2","key":"9173_CR1","doi-asserted-by":"crossref","first-page":"180","DOI":"10.4103\/jips.jips_157_18","volume":"19","author":"EM Gowda","year":"2019","unstructured":"Gowda EM, Naveen H, Gowda ME. Prosthetic rehabilitation for a Kennedy class II partially edentulous arch. J Indian Prosthodont Soc. 2019;19(2):180\u20134.","journal-title":"J Indian Prosthodont Soc"},{"issue":"2","key":"9173_CR2","first-page":"209","volume":"64","author":"S Koyama","year":"2020","unstructured":"Koyama S, Sasaki K, Yokoyama M, Sasaki T, Hanawa S. Evaluation of factors affecting the continuing use and patient satisfaction with removable partial dentures over 5 years. J Prosthodont Res. 2020;64(2):209\u201314.","journal-title":"J Prosthodont Res"},{"issue":"3","key":"9173_CR3","first-page":"101","volume":"2","author":"AR Jain","year":"2012","unstructured":"Jain AR, Philip JM, Ariga P. Attachment-retained unilateral distal extension (Kennedy\u2019s Class II Modification I) cast partial denture. Int J Prosthodont Restor Dent. 2012;2(3):101\u20137.","journal-title":"Int J Prosthodont Restor Dent"},{"issue":"1","key":"9173_CR4","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1097\/IO9.0000000000000235","volume":"63","author":"A Khalil","year":"2025","unstructured":"Khalil A. A rationale for rehabilitating posterior tooth loss through implant-to-tooth connection: a cohort retrospective study. Int J Surg Open. 2025;63(1):10\u20133.","journal-title":"Int J Surg Open"},{"issue":"1","key":"9173_CR5","doi-asserted-by":"publisher","first-page":"e70078","DOI":"10.1002\/cre2.70078","volume":"11","author":"S Barati","year":"2025","unstructured":"Barati S, Ghodsi S, Zeighami S. Effect of occlusal scheme and bone-level implant number and position on stress distribution in Kennedy Class II implant-assisted removable partial dentures: a 3D finite element analysis. Clin Exp Dent Res. 2025;11(1):e70078.","journal-title":"Clin Exp Dent Res"},{"issue":"9","key":"9173_CR6","doi-asserted-by":"publisher","first-page":"389","DOI":"10.3390\/dj13090389","volume":"13","author":"RC Dinu","year":"2025","unstructured":"Dinu RC, et al. Clinical performance and longevity of implant-assisted removable partial dentures compared to other removable prosthesis types: a systematic review. Dent J (Basel). 2025;13(9):389\u201399.","journal-title":"Dent J (Basel)"},{"issue":"1","key":"9173_CR7","doi-asserted-by":"publisher","first-page":"e70120","DOI":"10.1111\/cid.70120","volume":"28","author":"GO Gallucci","year":"2026","unstructured":"Gallucci GO, Hamilton A, Zhou W, et al. Current state of evidence for implant placement and loading in partially edentulous patients: a systematic review. Clin Implant Dent Relat Res. 2026;28(1):e70120.","journal-title":"Clin Implant Dent Relat Res"},{"key":"9173_CR8","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1186\/s40729-023-00500-3","volume":"9","author":"H Ichikawa","year":"2023","unstructured":"Ichikawa H, Yoda N, Ogawa T, et al. Impact of implant location on load distribution of implant-assisted removable partial dentures: a review of in vitro model and finite-element analysis studies. Int J Implant Dent. 2023;9:31\u201340.","journal-title":"Int J Implant Dent"},{"issue":"3","key":"9173_CR9","doi-asserted-by":"publisher","first-page":"215","DOI":"10.4047\/jkap.2023.61.3.215","volume":"62","author":"JH Kim","year":"2024","unstructured":"Kim JH, Park JH. Implant-assisted removable partial denture restoration in small number of residual teeth in mandible: a case report. J Korean Acad Prosthodont. 2024;62(3):215\u201323.","journal-title":"J Korean Acad Prosthodont"},{"issue":"2","key":"9173_CR10","doi-asserted-by":"publisher","first-page":"176","DOI":"10.4047\/jkap.2025.63.2.176","volume":"63","author":"HE Lee","year":"2025","unstructured":"Lee HE, Yim SY, Kim SY, Jang HW, Lee YS, Lee KW, Bang JH. Prosthodontic treatment with implant-assisted partial denture for limited abutment teeth and bone loss: case report. J Korean Acad Prosthodont. 2025;63(2):176\u201385. https:\/\/doi.org\/10.4047\/jkap.2025.63.2.176.","journal-title":"J Korean Acad Prosthodont"},{"key":"9173_CR11","doi-asserted-by":"publisher","first-page":"386","DOI":"10.2340\/aos.v84.43871","volume":"84","author":"MF Borda","year":"2025","unstructured":"Borda MF, P\u00e1ez-Garc\u00eda S, Murcia LF, Venegas-Sanabria LC, Borda MG. Comparative outcomes of endodontically treated teeth versus dental implant-supported prostheses: a systematic review. Acta Odontol Scand. 2025;84:386\u201396.","journal-title":"Acta Odontol Scand"},{"key":"9173_CR12","doi-asserted-by":"publisher","first-page":"213","DOI":"10.5005\/jp-journals-10015-1159","volume":"3","author":"S Ghodsi","year":"2012","unstructured":"Ghodsi S, Rasaeipour S. Tooth-implant connection: a literature review. world J dentistry. 2012;3:213\u20139. https:\/\/doi.org\/10.5005\/jp-journals-10015-1159.","journal-title":"world J dentistry"},{"issue":"5","key":"9173_CR13","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1097\/ID.0000000000000901","volume":"28","author":"M Ting","year":"2019","unstructured":"Ting M, Faulkner RJ, Donatelli DP, Suzuki JB. Tooth-to-implant-supported fixed partial denture: a comprehensive overview of systematic reviews. Implant Dent. 2019;28(5):490\u20139.","journal-title":"Implant Dent"},{"issue":"2","key":"9173_CR14","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1055\/s-0043-1772780","volume":"18","author":"S Hashemi","year":"2024","unstructured":"Hashemi S, Baghaei K, Fathi A, Aghadavoudi N, Hashemi SS, Atash R, Khademi SS. Stress analysis of endodontically treated tooth\u2013implant different connectors designs in maxillary posterior region: a finite element analysis. Eur J Dent. 2024;18(2):587\u201397.","journal-title":"Eur J Dent"},{"issue":"3","key":"9173_CR15","first-page":"285","volume":"63","author":"T Gonda","year":"2019","unstructured":"Gonda T, Maeda Y, Walton JN, MacEntee MI. A survey of patient satisfaction with removable partial dentures and an analysis of factors influencing satisfaction. J Prosthodont Res. 2019;63(3):285\u20139.","journal-title":"J Prosthodont Res"},{"issue":"1","key":"9173_CR16","first-page":"1","volume":"63","author":"A Demirel","year":"2021","unstructured":"Demirel A, Ak\u00e7a K. Tooth-implant supported fixed partial dentures: a systematic review. J Oral Sci. 2021;63(1):1\u20137.","journal-title":"J Oral Sci"},{"issue":"1","key":"9173_CR17","first-page":"25","volume":"34","author":"A Naveau","year":"2021","unstructured":"Naveau A, Rignon-Bret C. A survey of tooth-implant supported fixed partial dentures: a systematic review. Int J Prosthodont. 2021;34(1):25\u201332.","journal-title":"Int J Prosthodont"},{"issue":"2","key":"9173_CR18","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1034\/j.1600-0501.1995.060203.x","volume":"6","author":"CH H\u00e4mmerle","year":"1995","unstructured":"H\u00e4mmerle CH, Wagner D, Br\u00e4gger U. Threshold of tactile sensitivity perceived with dental endosseous implants and natural teeth. Clin Oral Implants Res. 1995;6(2):83\u201390.","journal-title":"Clin Oral Implants Res"},{"issue":"2","key":"9173_CR19","first-page":"177","volume":"6","author":"B Rangert","year":"1991","unstructured":"Rangert B, Gunne J, Sullivan DY. Mechanical aspects of a Br\u00e5nemark implant connected to a natural tooth: an in vitro study. Int J Oral Maxillofac Implants. 1991;6(2):177\u201386.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"3","key":"9173_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1615\/JLongTermEffMedImplants.2024051823","volume":"35","author":"G Shahi","year":"2025","unstructured":"Shahi G, Behnia P, Mosaddad SA, Alikhasi M. Intrusion of a non-splinted tooth surrounded by free-standing dental implants: a new phenomenon. J Long Term Eff Med Implants. 2025;35(3):1\u20138.","journal-title":"J Long Term Eff Med Implants"},{"issue":"4","key":"9173_CR21","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1111\/j.1532-849X.1997.tb00107.x","volume":"6","author":"IJ Pesun","year":"1997","unstructured":"Pesun IJ. Intrusion of teeth in the combination implant-to-natural-tooth fixed partial denture: a review of the theories. J Prosthodont. 1997;6(4):268\u201377.","journal-title":"J Prosthodont"},{"issue":"1","key":"9173_CR22","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1097\/01.id.0000154792.14103.94","volume":"14","author":"Z Ormianer","year":"2005","unstructured":"Ormianer Z, Brosh T, Laufer BZ, Shifman A. Strains recorded in a combined tooth-implant restoration: an in vivo study. Implant Dent. 2005;14(1):58\u201362.","journal-title":"Implant Dent"},{"issue":"3","key":"9173_CR23","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1034\/j.1600-0501.2001.012003245.x","volume":"12","author":"IE Naert","year":"2001","unstructured":"Naert IE, Duyck JA, Hosny MM, Quirynen M, van Steenberghe D. Freestanding and tooth-implant connected prostheses in the treatment of partially edentulous patients. Part II: An up to 15-years radiographic evaluation. Clin Oral Implants Res. 2001;12(3):245\u201351.","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"9173_CR24","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1111\/prd.12416","volume":"88","author":"I Sailer","year":"2022","unstructured":"Sailer I, Karasan D, Todorovic A, Ligoutsikou M, Pjetursson BE. Prosthetic failures in dental implant therapy. Periodontol 2000. 2022;88(1):130\u201344.","journal-title":"Periodontol 2000"},{"issue":"2","key":"9173_CR25","first-page":"27","volume":"35","author":"P Papaspyridakos","year":"2020","unstructured":"Papaspyridakos P, Bordin TB, Kim YJ, et al. Complications and survival rates of tooth-implant-supported fixed complete dental prostheses: a systematic review. Int J Oral Maxillofac Implants. 2020;35(2):27\u201339.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"1","key":"9173_CR26","first-page":"518","volume":"16","author":"CL Lin","year":"2021","unstructured":"Lin CL, Wang JC, Chang WJ. Biomechanical evaluation of dental implants using finite element analysis. J Dent Sci. 2021;16(1):518\u201325.","journal-title":"J Dent Sci"},{"issue":"2","key":"9173_CR27","first-page":"245","volume":"67","author":"N Ueda","year":"2023","unstructured":"Ueda N, Takata M, Kato M, Saito M, Kondo S. Influence of connection type in tooth-implant-supported fixed partial dentures on bone stress: a finite element analysis. J Prosthodont Res. 2023;67(2):245\u201351.","journal-title":"J Prosthodont Res"},{"key":"9173_CR28","first-page":"6657480","volume":"2021","author":"MI El-Anwar","year":"2021","unstructured":"El-Anwar MI, El-Zawahry MM. A three-dimensional finite element analysis on the effects of non-rigid connectors in tooth-implant supported fixed partial dentures. Int J Dent. 2021;2021:6657480.","journal-title":"Int J Dent"},{"issue":"1","key":"9173_CR29","first-page":"1","volume":"63","author":"A Demirel","year":"2021","unstructured":"Demirel A, Ak\u00e7a K. Tooth-implant supported fixed partial dentures: a systematic review. J Oral Sci. 2021;63(1):1\u20137.","journal-title":"J Oral Sci"},{"issue":"3","key":"9173_CR30","first-page":"257","volume":"30","author":"A Bacchi","year":"2019","unstructured":"Bacchi A, Consani RL, Mesquita MF, dos Santos MB. Influence of framework material and pontic number on the stress distribution in implant-supported prostheses. Braz Dent J. 2019;30(3):257\u201363.","journal-title":"Braz Dent J"},{"issue":"3","key":"9173_CR31","first-page":"1015","volume":"21","author":"J Abduo","year":"2021","unstructured":"Abduo J, Sambrook RJ. Longevity of tooth-implant supported fixed partial dentures compared to implant-supported fixed partial dentures: a systematic review. J Evid Based Dent Pract. 2021;21(3):1015\u201343.","journal-title":"J Evid Based Dent Pract"},{"issue":"1","key":"9173_CR32","doi-asserted-by":"crossref","first-page":"12","DOI":"10.4047\/jap.2022.14.1.12","volume":"14","author":"MB Gungor","year":"2022","unstructured":"Gungor MB, Bal BT, Yilmaz H, Aydin C. Evaluation of stresses on implant, bone, and restoration in mandibular implant-supported fixed partial dentures with different pontic numbers. J Adv Prosthodont. 2022;14(1):12\u201323.","journal-title":"J Adv Prosthodont"},{"key":"9173_CR33","doi-asserted-by":"publisher","first-page":"5116","DOI":"10.3390\/app12105116","volume":"12","author":"OC Andrei","year":"2022","unstructured":"Andrei OC, T\u0103n\u0103sescu LA, T\u0103rlungeanu ID, Dina MN, Tierean MH. Finite element comparative analysis of von mises stress levels in unilateral removable partial denture with and without distal implant. Appl Sci. 2022;12:5116. https:\/\/doi.org\/10.3390\/app12105116.","journal-title":"Appl Sci"},{"issue":"1","key":"9173_CR34","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1590\/S1678-77572007000100015","volume":"15","author":"EB De Las Casas","year":"2007","unstructured":"De Las Casas EB, de Almeida AF, Cimini CA, Junior, et al. Determination of tangential and normal components of oral forces. J Appl Oral Sci. 2007;15(1):70\u20136.","journal-title":"J Appl Oral Sci"},{"issue":"1","key":"9173_CR35","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.prosdent.2003.09.009","volume":"91","author":"C Asvanud","year":"2004","unstructured":"Asvanud C, Morgano SM. Restoration of unfavorably positioned implants for a partially edentulous patient by using an overdenture retained with a milled bar and attachments: a clinical report. J Prosthet Dent. 2004;91(1):6\u201310.","journal-title":"J Prosthet Dent"},{"issue":"6","key":"9173_CR36","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1563\/1548-1336(2007)33[344:TTFIRA]2.0.CO;2","volume":"33","author":"B Uludag","year":"2007","unstructured":"Uludag B, Celik G. Technical tips for improved retention and stabilization of a unilateral removable partial denture. J Oral Implantol. 2007;33(6):344\u20136.","journal-title":"J Oral Implantol"},{"key":"9173_CR37","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s40729-022-00405-7","volume":"8","author":"S Spalthoff","year":"2022","unstructured":"Spalthoff S, Borrmann M, Jehn P, Rahlf B, Gellrich NC, Korn P. Comparison of conventional and digital workflow for dental rehabilitation with a novel patient-specific framework implant system: an experimental dataset evaluation. Int J Implant Dent. 2022;8:4\u201310.","journal-title":"Int J Implant Dent"},{"issue":"2","key":"9173_CR38","first-page":"1","volume":"16","author":"RS ChiChidambaram","year":"2024","unstructured":"ChiChidambaram RS, Rajmohan S, Manickam S, Mallikarjuna R, Nalawade T, Saraf S. Efficacy of a novel computerized aid in designing removable partial dentures. Cureus. 2024;16(2):1\u201310. e54581.","journal-title":"Cureus"},{"issue":"6","key":"9173_CR39","doi-asserted-by":"publisher","first-page":"980","DOI":"10.3390\/ma12060980","volume":"12","author":"A Brizuela","year":"2019","unstructured":"Brizuela A, Herrero-Climent M, Rios-Carrasco E, et al. Influence of the elastic modulus on the osseointegration of dental implants. Mater (Basel). 2019;12(6):980\u20137.","journal-title":"Mater (Basel)"},{"issue":"60","key":"9173_CR40","first-page":"1","volume":"6","author":"T Nogawa","year":"2020","unstructured":"Nogawa T, Saito M, Murashima N, Takayama Y, Yokoyama A. Influence of rigidity of retainers on dynamic behavior of implant-supported removable partial dentures. Int J Imp Dent. 2020;6(60):1\u20139.","journal-title":"Int J Imp Dent"},{"issue":"3","key":"9173_CR41","first-page":"1","volume":"3","author":"CM Maciel","year":"2023","unstructured":"Maciel CM, Vieiras Souto TC, J\u00fanior AA. Use of Attachments in Rehabilitations with Removable Partial Dentures: Case Report. Int J Orl Health. 2023;3(3):1\u20134.","journal-title":"Int J Orl Health"},{"key":"9173_CR42","doi-asserted-by":"publisher","first-page":"626","DOI":"10.2174\/1874210602115010626","volume":"15","author":"M Sharaf","year":"2021","unstructured":"Sharaf M. Attachment-retained unilateral partial denture versus tooth implant- prosthesis in mandibular distal extension cases: a randomized controlled trial. Open Dent J. 2021;15:626\u201335.","journal-title":"Open Dent J"},{"issue":"1","key":"9173_CR43","doi-asserted-by":"publisher","first-page":"34","DOI":"10.30699\/jidai.28.1.34","volume":"28","author":"MN Khaki","year":"2016","unstructured":"Khaki MN, Shishehian A. Stress distribution in natural tooth and implant supported removable partial denture with different attachment types: a photoelastic analysis. J Islamic Dent Assoc Iran (JIDAI). 2016;28(1):34\u20139.","journal-title":"J Islamic Dent Assoc Iran (JIDAI)"},{"key":"9173_CR44","first-page":"1897","volume":"65","author":"IA El-asfahani","year":"2019","unstructured":"El-asfahani IA, Nawar NH. The effect of using different designs on distal implant for treatment of mandibular kennedy class II cases. EDJ. 2019;65:1897\u2013905.","journal-title":"EDJ"},{"key":"9173_CR45","doi-asserted-by":"publisher","first-page":"15769","DOI":"10.24327\/ijrsr.2017.0803.0025","volume":"8","author":"SB Agdive","year":"2017","unstructured":"Agdive SB, Shah RJ, Shrof SN. Equilibrating functional stability with aesthetic harmony in kennedy class II saddle area using precision attachment: a dexterous alternative to implants. Int J Recent Sci Res. 2017;8:15769\u201372.","journal-title":"Int J Recent Sci Res"},{"issue":"2","key":"9173_CR46","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1563\/AAID-JOI-D-10-00071","volume":"38","author":"O Hoffmann","year":"2012","unstructured":"Hoffmann O, Zafiropoulos GG. Tooth-implant connection: a review. J Oral Implantol. 2012;38(2):194\u2013200.","journal-title":"J Oral Implantol"},{"issue":"3","key":"9173_CR47","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1016\/j.jpor.2019.09.007","volume":"64","author":"T Ohyama","year":"2020","unstructured":"Ohyama T, Nakabayashi S, Yasuda H, Kase T, Namaki S. Mechanical analysis of the effects of implant position and abutment height on implant-assisted removable partial dentures. J Prosthodont Res. 2020;64(3):340\u20135.","journal-title":"J Prosthodont Res"},{"issue":"11","key":"9173_CR48","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1111\/j.1365-2842.2008.01868.x","volume":"35","author":"H Itoh","year":"2008","unstructured":"Itoh H, Baba K, Aridome K, Okada D, Tokuda A, Nishiyama A, et al. Effect of direct retainer and major connector designs on RPD and abutment tooth movement dynamics. J Oral Rehabil. 2008;35(11):810\u20135.","journal-title":"J Oral Rehabil"},{"issue":"3\u20134","key":"9173_CR49","doi-asserted-by":"publisher","first-page":"188","DOI":"10.2298\/SARH1604188G","volume":"144","author":"M Gli\u0161i\u0107","year":"2016","unstructured":"Gli\u0161i\u0107 M, Stamenkovi\u0107 D, Grbovi\u0107 A, Todorovi\u0107 A, Markovi\u0107 A, Trifkovi\u0107 B. Analysis of load distribution in tooth-implant supported fixed partial dentures by the use of resilient abutment. Srp Arh Celok Lek. 2016;144(3\u20134):188\u201395.","journal-title":"Srp Arh Celok Lek"},{"key":"9173_CR50","doi-asserted-by":"crossref","unstructured":"Biswas BK, Das B, Saha A. Rahul Paul. Tooth implant supported prosthesis verses implant supported prosthesis: a literature review. New Front Med Med Res. 2021;13:35\u201349. BP International, \u27e8hal-05241139\u27e9.","DOI":"10.9734\/bpi\/nfmmr\/v13\/11607D"},{"key":"9173_CR51","first-page":"315","volume":"10","author":"D Melilli","year":"2017","unstructured":"Melilli D, Dav\u00ec G, Mauceri R, Messina, Pietro, Alessandro, Scardina. Tooth-implant-supported removable denture: A systematic review. Int J Clin Dentistry. 2017;10:315\u201342.","journal-title":"Int J Clin Dentistry"},{"key":"9173_CR52","unstructured":"Lindh T, Dahlgren S, Gunnarsson K, Josefsson T, Nilson H, Wilhelmsson P, Gunne J. Tooth-implant supported fixed prostheses: a retrospective multicenter study. Int J Prosthodont. 2001;14(4):321\u20138. PMID: 11508086."},{"key":"9173_CR53","doi-asserted-by":"crossref","unstructured":"Mozayek RS, Mozayek MY, Allaf M, Abouharb MB. The effectiveness of adding a supporting implant in stress distribution of long span fixed partial denture (three-dimensional finite element analysis). J Indian Prosthodont Soc. 2016;16(3):259\u201363.","DOI":"10.4103\/0972-4052.176533"},{"key":"9173_CR54","unstructured":"Krennmair G, Krainh\u00f6fner M, Waldenberger O, Piehslinger E. Dental implants as strategic supplementary abutments for implant-tooth-supported telescopic crown-retained maxillary dentures: a retrospective follow-up study for up to 9 years. Int J Prosthodont. 2007;20(6):617\u201322."},{"issue":"10","key":"9173_CR55","doi-asserted-by":"publisher","first-page":"6003","DOI":"10.1007\/s00784-022-04622-7","volume":"26","author":"P Molinero-Mourelle","year":"2022","unstructured":"Molinero-Mourelle P, Bischof F, Yilmaz B, Schimmel M, Abou-Ayash S. Clinical performance of tooth implant-supported removable partial dentures: a systematic review and meta-analysis. Clin Oral Investig. 2022;26(10):6003\u201314.","journal-title":"Clin Oral Investig"},{"issue":"3","key":"9173_CR56","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1080\/10255842.2015.1009450","volume":"19","author":"W Xiao","year":"2016","unstructured":"Xiao W, Li Z, Shen S, Chen S, Chen S, Wang J. Influence of connection type on the biomechanical behavior of distal extension mandibular removable partial dentures supported by implants and natural teeth. Comput Methods Biomech Biomed Engin. 2016;19(3):240\u20137.","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"1","key":"9173_CR57","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1038\/s41368-025-00354-y","volume":"17","author":"X Wen","year":"2025","unstructured":"Wen X, Pei F, Jin Y, Zhao Z. Exploring the mechanical and biological interplay in the periodontal ligament. Int J Oral Sci. 2025;17(1):23.","journal-title":"Int J Oral Sci"},{"key":"9173_CR58","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1016\/j.actbio.2024.09.016","volume":"188","author":"M Liu","year":"2024","unstructured":"Liu M, Wu B, Yang F, Jiang D, Izadikhah I, Chen Y, et al. Understanding the hierarchical structure of collagen fibers of the human periodontal ligament: Implications for biomechanical characteristics. Acta Biomater. 2024;188:253\u201365.","journal-title":"Acta Biomater"},{"issue":"1","key":"9173_CR59","first-page":"312980","volume":"2","author":"PW Major","year":"2011","unstructured":"Major PW, Fill TS, Carey JP, Toogood RW. Experimentally determined mechanical properties of, and models for, the periodontal ligament: critical review of current literature. J Dent Biomech. 2011;2(1):312980.","journal-title":"J Dent Biomech"},{"key":"9173_CR60","doi-asserted-by":"publisher","first-page":"1461909","DOI":"10.3389\/fdmed.2024.1461909","volume":"5","author":"C \u00d6zcan","year":"2024","unstructured":"\u00d6zcan C, Lestriez P, \u00d6zcan M, Josset Y. Finite element analysis of dental structures: the role of mandibular kinematics and model complexity. Front Dent Med. 2024;5:1461909.","journal-title":"Front Dent Med"},{"key":"9173_CR61","doi-asserted-by":"publisher","first-page":"269","DOI":"10.3389\/fbioe.2019.00269","volume":"7","author":"HM Abraha","year":"2019","unstructured":"Abraha HM, Iriarte-Diaz J, Ross CF, Taylor AB, Panagiotopoulou O. The mechanical effect of the periodontal ligament on bone strain regimes in a validated finite element model of a macaque mandible. Front Bioeng Biotechnol. 2019;7:269.","journal-title":"Front Bioeng Biotechnol"},{"issue":"1","key":"9173_CR62","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1186\/s12938-018-0607-0","volume":"17","author":"B Wu","year":"2018","unstructured":"Wu B, Fu Y, Shi H, Yan B, Lu R, Ma S, Markert B. Tensile testing of the mechanical behavior of the human periodontal ligament. Biomed Eng Online. 2018;17(1):172. https:\/\/doi.org\/10.1186\/s12938-018-0607-0 . PMID: 30470224; PMCID: PMC6251174.","journal-title":"Biomed Eng Online"},{"key":"9173_CR63","doi-asserted-by":"publisher","first-page":"7852","DOI":"10.3390\/ma15217852","volume":"15","author":"Sa\u00fal Dorado","year":"2022","unstructured":"Dorado Sa\u00fal, Arias A. Jimenez-Octavio, Jesus. Biomechanical Modelling for Tooth Survival Studies: Mechanical Properties, Loads and Boundary Conditions\u2014A. Narrative Rev Mater. 2022;15:7852. https:\/\/doi.org\/10.3390\/ma15217852.","journal-title":"Narrative Rev Mater"},{"issue":"6","key":"9173_CR64","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1016\/j.ajodo.2022.09.008","volume":"162","author":"A Dongcai Wang","year":"2022","unstructured":"Dongcai Wang A, Akbari F, Jiang Y, Liu, Chen J. The effects of different types of periodontal ligament material models on stresses computed using finite element models. Am J Orthod Dentofac Orthop. 2022;162(6):328\u201336.","journal-title":"Am J Orthod Dentofac Orthop"},{"issue":"7","key":"9173_CR65","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1016\/j.jdent.2008.03.010","volume":"36","author":"N Wakabayashi","year":"2008","unstructured":"Wakabayashi N, Ona M, Suzuki T, Igarashi Y. Nonlinear finite element analyses: advances and challenges in dental applications. J Dent. 2008;36(7):463\u201371.","journal-title":"J Dent"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-09173-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-09173-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-09173-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T17:19:47Z","timestamp":1785518387000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-09173-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,22]]},"references-count":65,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["9173"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-09173-x","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,22]]},"assertion":[{"value":"17 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study was approved by the Ethical Committee of the British University in Egypt (BUE) with research approval number 25\u2009\u2212\u200902. \u201cIn accordance with the Declaration of Helsinki.\u201d \u201cNot applicable\u201d this study didn\u2019t involve the use of any animal or human data or tissue.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"\u201cNot applicable\u201d","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"1351"}}