{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:37:51Z","timestamp":1792787871118,"version":"4.5.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,27]],"date-time":"2026-07-27T00:00:00Z","timestamp":1785110400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T00:00:00Z","timestamp":1790294400000},"content-version":"vor","delay-in-days":60,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"University of Zurich","id":[{"id":"https:\/\/ror.org\/02crff812","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The aim of this study was to evaluate the load-bearing capacity of zirconia, lithium disilicate, and resin-matrix composite occlusal veneers bonded to different substrates: dentin surrounded by enamel (DE), dentin (D), and resin composite (C), simulating eroded teeth.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Occlusal veneers (1.0\u00a0mm thick) were milled from zirconia (IPS e.max ZirCAD), lithium disilicate (IPS e.max CAD; Initial LiSi Block), and resin-matrix composite (Lava Ultimate), and bonded to the different substrates (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200910 per group). Specimens were cemented, subjected to thermo-mechanical aging (1,200,000 cycles; 5\u201350\u00a0\u00b0C), and tested under monotonic load-to-fracture. Maximum fracture load (Fmax) data were analyzed using the Shapiro\u2013Wilk and Levene tests for normality and homoscedasticity, followed by two-way ANOVA and Tukey\u2019s post hoc test (\u03b1\u2009=\u20090.05). Weibull analysis was performed to assess structural reliability, and Pearson\u2019s correlation analysis was used to evaluate the relationship between bonded surface area and Fmax.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The results indicated that both restorative material and substrate type significantly affected Fmax. Lithium disilicate veneers exhibited substrate-dependent behavior, with higher fracture loads when bonded to resin composite, intermediate values when bonded to DE, and the lowest values when bonded to D. The resin-matrix composite showed a more homogeneous response across substrates, although Fmax decreased from resin composite to dentin. Zirconia restorations demonstrated consistently high fracture loads across all substrates, without a substrate-dependent trend. Failure modes were predominantly adhesive or mixed for lithium disilicate, whereas cohesive veneer failures predominated for zirconia.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Both restorative material and substrate condition significantly affected the strength and reliability of ultra-thin occlusal veneers. Zirconia showed the most robust performance and the lowest sensitivity to substrate variations, whereas bonding to resin composite substrates improved reliability compared with dentin. These findings highlight the importance of substrate management and adhesive optimization when restoring eroded teeth.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-026-09356-6","type":"journal-article","created":{"date-parts":[[2026,7,27]],"date-time":"2026-07-27T11:54:49Z","timestamp":1785153289000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Load-bearing capacities of occlusal veneers made of all-ceramic and resin composite: do the substrate and material type affect mechanical durability?"],"prefix":"10.1186","volume":"26","author":[{"given":"Arta","family":"Lamallari","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vera","family":"Colombo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luiza Freitas Brum","family":"Souza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enkelejd Angelo","family":"Cankja","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abd\u00fclhakim Alpaslan","family":"Sener","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mutlu","family":"\u00d6zcan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,27]]},"reference":[{"key":"9356_CR1","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1159\/000359936","volume":"25","author":"RP Shellis","year":"2014","unstructured":"Shellis RP, Addy M. The interactions between attrition, abrasion and erosion in tooth wear. Monogr Oral Sci. 2014;25:32\u201345.","journal-title":"Monogr Oral Sci"},{"key":"9356_CR2","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1111\/joor.12340","volume":"43","author":"P Wetselaar","year":"2016","unstructured":"Wetselaar P, Lobbezoo F. The tooth wear evaluation system: a modular clinical guideline for the diagnosis and management planning of worn dentitions. J Oral Rehabil. 2016;43:69\u201380.","journal-title":"J Oral Rehabil"},{"key":"9356_CR3","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1016\/j.jdent.2013.08.018","volume":"41","author":"DW Bartlett","year":"2013","unstructured":"Bartlett DW, Lussi A, West NX, Bouchard P, Sanz M, Bourgeois D. Prevalence of tooth wear on buccal and lingual surfaces and possible risk factors in young European adults. J Dent. 2013;41:1007\u201313.","journal-title":"J Dent"},{"key":"9356_CR4","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/S0022-3913(96)90413-8","volume":"75","author":"JR Kelly","year":"1996","unstructured":"Kelly JR, Nishimura I, Campbell SD. Ceramics in dentistry: Historical roots and current perspectives. J Prosthet Dent. 1996;75:18\u201332.","journal-title":"J Prosthet Dent"},{"key":"9356_CR5","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.jdent.2018.01.001","volume":"70","author":"BAC Loomans","year":"2018","unstructured":"Loomans BAC, Kreulen CM, Huijs-Visser HECE, Sterenborg BAMM, Bronkhorst EM, Huysmans MCDNJM. Clinical performance of full rehabilitations with direct composite in severe tooth wear patients: 3.5-year results. J Dent. 2018;70:97\u2013103.","journal-title":"J Dent"},{"key":"9356_CR6","doi-asserted-by":"crossref","unstructured":"Boitelle P. Contemporary management of minimal invasive aesthetic treatment of dentition affected by erosion: case report. BMC Oral Health. 2019;19(1):123.","DOI":"10.1186\/s12903-019-0807-4"},{"key":"9356_CR7","first-page":"241","volume":"22","author":"D Edelhoff","year":"2002","unstructured":"Edelhoff D, Sorensen JA. Tooth structure removal associated with various preparation designs for posterior teeth. Int J Periodontics Restor Dent. 2002;22:241\u20139.","journal-title":"Int J Periodontics Restor Dent"},{"key":"9356_CR8","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1016\/j.jmbbm.2019.04.006","volume":"95","author":"M Maeder","year":"2019","unstructured":"Maeder M, Pasic P, Ender A, \u00d6zcan M, Benic GI, Ioannidis A. Load-bearing capacities of ultra-thin occlusal veneers bonded to dentin. J Mech Behav Biomed Mater. 2019;95:165\u201371.","journal-title":"J Mech Behav Biomed Mater"},{"key":"9356_CR9","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.jmbbm.2018.09.041","volume":"90","author":"A Ioannidis","year":"2019","unstructured":"Ioannidis A, M\u00fchlemann S, \u00d6zcan M, H\u00fcsler J, H\u00e4mmerle CHF, Benic GI. Ultra-thin occlusal veneers bonded to enamel and made of ceramic or hybrid materials exhibit load-bearing capacities not different from conventional restorations. J Mech Behav Biomed Mater. 2019;90:433\u201340.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"4","key":"9356_CR10","doi-asserted-by":"publisher","first-page":"e109","DOI":"10.1016\/j.dental.2020.01.016","volume":"36","author":"A Ioannidis","year":"2020","unstructured":"Ioannidis A, Bomze D, H\u00e4mmerle CHF, H\u00fcsler J, Birrer O, M\u00fchlemann S. Load-bearing capacity of CAD\/CAM 3D-printed zirconia, CAD\/CAM milled zirconia, and heat-pressed lithium disilicate ultra-thin occlusal veneers on molars. Dent Mater. 2020;36(4):e109\u201316.","journal-title":"Dent Mater"},{"issue":"3","key":"9356_CR11","doi-asserted-by":"publisher","first-page":"365","DOI":"10.11607\/ijp.6735","volume":"34","author":"N M\u00f6rikofer","year":"2021","unstructured":"M\u00f6rikofer N, Benic G, Park JM, \u00d6zcan M, H\u00fcsler J, Ioannidis A. Relationship between internal accuracy and load-bearing capacity of minimally invasive lithium disilicate occlusal veneers. Int J Prosthodont. 2021;34(3):365\u201372.","journal-title":"Int J Prosthodont"},{"issue":"1","key":"9356_CR12","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1111\/jerd.12861","volume":"34","author":"PC Gierthmuehlen","year":"2022","unstructured":"Gierthmuehlen PC, Jerg A, Fischer JB, Bonfante EA, Spitznagel FA. Posterior minimally invasive full-veneers: Effect of ceramic thicknesses, bonding substrate, and preparation designs on failure load and mode after fatigue. J Esthet Restor Dent. 2022;34(1):145\u201353.","journal-title":"J Esthet Restor Dent"},{"key":"9356_CR13","doi-asserted-by":"crossref","unstructured":"Zumstein K, Fiscalini L, Al-Haj Husain N, Evci E, \u00d6zcan M, Ioannidis A. Load-bearing capacity of pressable lithium disilicates applied as ultra-thin occlusal veneers on molars. J Mech Behav Biomed Mater. 2022;136:105520.","DOI":"10.1016\/j.jmbbm.2022.105520"},{"key":"9356_CR14","first-page":"206","volume":"25","author":"T Yli-Urpo","year":"2025","unstructured":"Yli-Urpo T, Le Bell Y, Tj\u00e4derhane L, N\u00e4rhi T, Peltom\u00e4ki T, Vallittu P. Occlusal veneers and load-bearing capacity of a restored tooth. Int J Prosthodont. 2025;25:206\u201313.","journal-title":"Int J Prosthodont"},{"key":"9356_CR15","first-page":"113","volume":"28","author":"NAH Husain","year":"2020","unstructured":"Husain NAH, Sonderegger S, \u00d6zcan M, Br\u00e4gger U, Joda T. In vitro static and fatigue behavior of ceramic occlusal veneers using CAD\/CAM. Eur J Prosthodont Restor Dent. 2020;28:113\u201320.","journal-title":"Eur J Prosthodont Restor Dent"},{"key":"9356_CR16","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1016\/j.dental.2003.05.002","volume":"20","author":"M Guazzato","year":"2004","unstructured":"Guazzato M, Albakry M, Ringer SP, Swain MV. Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II: Zirconia-based dental ceramics. Dent Mater. 2004;20:449\u201356.","journal-title":"Dent Mater"},{"key":"9356_CR17","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1007\/s40496-023-00344-1","volume":"10","author":"J Hjerppe","year":"2023","unstructured":"Hjerppe J, \u00d6zcan M, Zirconia. More and more translucent. Curr Oral Health Rep. 2023;10:203\u201311.","journal-title":"Curr Oral Health Rep"},{"key":"9356_CR18","doi-asserted-by":"publisher","first-page":"1602","DOI":"10.1016\/j.dental.2024.07.017","volume":"40","author":"PN Paqu\u00e9","year":"2024","unstructured":"Paqu\u00e9 PN, Gantner C, M\u00e4tzener KJ, \u00d6zcan M, Ioannidis A. Load-bearing capacity, internal accuracy and time-efficiency of heat-pressed, milled and 3D-printed lithium disilicate ultra-thin occlusal veneers. Dent Mater. 2024;40:1602\u201310.","journal-title":"Dent Mater"},{"key":"9356_CR19","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1016\/j.jdent.2007.07.002","volume":"35","author":"EA Tsitrou","year":"2007","unstructured":"Tsitrou EA, Northeast SE, van Noort R. Brittleness index of machinable dental materials and its relation to the marginal chipping factor. J Dent. 2007;35:897\u2013902.","journal-title":"J Dent"},{"key":"9356_CR20","doi-asserted-by":"crossref","unstructured":"Alamoush RA, Silikas N, Salim NA, Al-Nasrawi S, Satterthwaite JD. Effect of the composition of CAD\/CAM composite blocks on mechanical properties. Biomed Res Int. 2018:489314","DOI":"10.1155\/2018\/4893143"},{"key":"9356_CR21","doi-asserted-by":"publisher","first-page":"539","DOI":"10.2341\/17-131-L","volume":"43","author":"JP Andrade","year":"2018","unstructured":"Andrade JP, Stona D, Bittencourt HR, Borges GA, Burnett LH, Spohr AM. Effect of different CAD\/CAM materials and thicknesses on the fracture resistance of occlusal veneers. Oper Dent. 2018;43:539\u201348.","journal-title":"Oper Dent"},{"key":"9356_CR22","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1016\/S0022-3913(10)60111-4","volume":"104","author":"P Magne","year":"2010","unstructured":"Magne P, Schlichting LH, Maia HP, Baratieri LN. In vitro fatigue resistance of CAD\/CAM composite resin and ceramic posterior occlusal veneers. J Prosthet Dent. 2010;104:149\u201357.","journal-title":"J Prosthet Dent"},{"key":"9356_CR23","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/S0022-3913(11)60035-8","volume":"105","author":"LH Schlichting","year":"2011","unstructured":"Schlichting LH, Maia HP, Baratieri LN, Magne P. Novel-design ultra-thin CAD\/CAM composite resin and ceramic occlusal veneers for the treatment of severe dental erosion. J Prosthet Dent. 2011;105:217\u201326.","journal-title":"J Prosthet Dent"},{"key":"9356_CR24","doi-asserted-by":"publisher","first-page":"417","DOI":"10.17219\/dmp\/157347","volume":"61","author":"KDC Maldonado","year":"2024","unstructured":"Maldonado KDC, Espinoza JA, Astudillo DA, Delgado BA, Bravo WD. Resistance of CAD\/CAM composite resin and ceramic occlusal veneers to fatigue and fracture in worn posterior teeth: A systematic review. Dent Med Probl. 2024;61:417\u201326.","journal-title":"Dent Med Probl"},{"key":"9356_CR25","doi-asserted-by":"publisher","first-page":"742","DOI":"10.1016\/j.dental.2013.04.004","volume":"29","author":"L Ma","year":"2013","unstructured":"Ma L, Guess PC, Zhang Y. Load-bearing properties of minimal-invasive monolithic lithium disilicate and zirconia occlusal onlays: Finite element and theoretical analyses. Dent Mater. 2013;29:742\u201351.","journal-title":"Dent Mater"},{"key":"9356_CR26","unstructured":"Swiss Federal Council. Ordinance on Human Research with the Exception of Clinical Trials (Human Research Ordinance, HRO). SR 810.301. 20 Sep 2013. Updated 1 Sep 2023."},{"key":"9356_CR27","volume-title":"Ratification dated 29 April 2015","author":"Kantonale Ethikkommission Z\u00fcrich","year":"2015","unstructured":"Kantonale Ethikkommission Z\u00fcrich. Ratification dated 29 April 2015. Z\u00fcrich: Kantonale Ethikkommission Z\u00fcrich; 2015."},{"key":"9356_CR28","doi-asserted-by":"publisher","first-page":"2191","DOI":"10.1001\/jama.2013.281053","volume":"310","author":"WM Association","year":"2013","unstructured":"Association WM. World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects. JAMA. 2013;310:2191\u20134.","journal-title":"JAMA"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-09356-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-09356-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-09356-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T23:02:54Z","timestamp":1790377374000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-09356-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,27]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["9356"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-09356-6","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,27]]},"assertion":[{"value":"16 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study did not involve living human participants or any intervention on human subjects. The study used extracted human teeth obtained from the Center for Dental Medicine at the University of Zurich (Zurich, Switzerland). The teeth were extracted for clinical reasons unrelated to this study and were made available for research and other applications only after written informed consent for secondary use had been obtained from the donors, in accordance with the Swiss Federal Ordinance on Human Research [\n                      \n                      ]. All specimens were irreversibly anonymized before use in accordance with Swiss federal and cantonal regulations [\n                      \n                      ,\n                      \n                      ]. Under applicable Swiss Human Research legislation and the guidance of the Kantonale Ethikkommission Z\u00fcrich (Cantonal Ethics Committee Zurich), formal ethics committee approval was not required for this in vitro study using irreversibly anonymized extracted human teeth [\n                      \n                      ]. The study was conducted in accordance with the ethical principles of the Declaration of Helsinki [\n                      \n                      ].","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"1822"}}