{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T13:16:59Z","timestamp":1788009419092,"version":"build-2784847793"},"reference-count":54,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T00:00:00Z","timestamp":1785801600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T00:00:00Z","timestamp":1787961600000},"content-version":"vor","delay-in-days":25,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Freiburg"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Completely edentulous mandibles present a challenge for accurate intraoral scanning, which can compromise the passive fit of implant-supported restorations. Reverse scan bodies may improve the accuracy of implant position transfer and support a fully digital workflow. However, clinical evidence for their use in the edentulous mandible remains limited.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this single-patient prospective clinical evaluation, one fully edentulous mandible restored with two interforaminal implants was scanned ten times using an intraoral scanner (IOS). Based on each scan, titanium verification bars (VBs) were fabricated, and their passive fit was assessed clinically. After sectioning and intraoral re-splinting, splinted verification bars (SVBs) were digitized using reverse scan bodies and a laboratory scanner to fabricate new verification bars (NVBs). Linear and angular deviations between datasets (IOS, VB, SVB, NVB) were analyzed using metrology software and statistically evaluated with Welch\u2019s ANOVA and post hoc tests (\u03b1\u2009=\u20090.05).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      All VBs and NVBs demonstrated passive fit clinically. Mean linear deviations were 12\u00a0\u03bcm between IOS and VB, 50\u00a0\u03bcm between VB and SVB (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.001), and 26\u00a0\u03bcm between SVB and NVB (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.20). Mean angular deviations were 0.18\u00b0 between IOS and VB, with six measurements\u2009&gt;\u20090.4\u00b0; 0.79\u00b0 between VB and SVB (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.01), with seven measurements\u2009&gt;\u20090.4\u00b0; and 0.06\u00b0 between SVB and NVB, with four measurements\u2009&gt;\u20090.4\u00b0.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Within the limitations of this single-patient evaluation and the favorable two-implant mandibular configuration, intraoral scanning provided sufficient accuracy for fabricating passively fitting restorations on two implants in the edentulous mandible. Measurable linear and angular deviations did not compromise clinical fit in this case. The use of reverse scan bodies may be effective in cases of misfit after intraoral re-splinting, especially in more complex full-arch workflows, as only minor linear and angular deviations were observed in the NVBs with integrated abutments.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-026-09507-9","type":"journal-article","created":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T02:55:48Z","timestamp":1785812148000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Digital workflow for implant-supported restorations in the mandible including reverse scan bodies: a feasibility study"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-7814-6265","authenticated-orcid":false,"given":"Aiste","family":"Kernen-Gintaute","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M","family":"Akulauskas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F","family":"Kernen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S","family":"Wenger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"NU","family":"Zitzmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"BC","family":"Spies","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F","family":"Burkhardt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,4]]},"reference":[{"key":"9507_CR1","doi-asserted-by":"publisher","first-page":"e13398","DOI":"10.1111\/cid.13398","volume":"27","author":"T Van de Winkel","year":"2025","unstructured":"Van de Winkel T, Delfos F, van der Heijden O, Bronkhorst E, Verhamme L, Meijer G. Fully digital versus conventional workflow: Are removable complete overdentures equally good? A randomized crossover trial. Clin Implant Dent Relat Res. 2025;27:e13398.","journal-title":"Clin Implant Dent Relat Res"},{"key":"9507_CR2","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1186\/s12903-017-0415-0","volume":"17","author":"T Joda","year":"2017","unstructured":"Joda T, Zarone F, Ferrari M. The complete digital workflow in fixed prosthodontics: a systematic review. BMC Oral Health. 2017;17:124.","journal-title":"BMC Oral Health"},{"issue":"Suppl 21","key":"9507_CR3","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1111\/clr.13846","volume":"32","author":"S Bishti","year":"2021","unstructured":"Bishti S, Tuna T, Rittich A, Wolfart S. Patient-reported outcome measures (PROMs) of implant-supported reconstructions using digital workflows: a systematic review and meta-analysis. Clin Oral Implants Res. 2021;32(Suppl 21):318\u201335.","journal-title":"Clin Oral Implants Res"},{"key":"9507_CR4","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.1111\/clr.12753","volume":"27","author":"T Joda","year":"2016","unstructured":"Joda T, Br\u00e4gger U. Time-efficiency analysis of the treatment with monolithic implant crowns in a digital workflow: a randomized controlled trial. Clin Oral Implants Res. 2016;27:1401\u20136.","journal-title":"Clin Oral Implants Res"},{"key":"9507_CR5","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.1111\/jerd.13419","volume":"37","author":"M Revilla-Le\u00f3n","year":"2025","unstructured":"Revilla-Le\u00f3n M, Aragoneses R, Arroyo Valverde EM, G\u00f3mez-Polo M, Kois JC. Classification of scanning errors of digital scans recorded by using intraoral scanners. J Esthet Restor Dent. 2025;37:1363\u201371.","journal-title":"J Esthet Restor Dent"},{"key":"9507_CR6","doi-asserted-by":"crossref","unstructured":"Abdelrehim A, Bin Sulaiman E, Sofian H, Salleh NM. Time efficiency and precision of splinted complete arch implant scanning. J Prosthet Dent. 2025;134:223.e1-223.e7.","DOI":"10.1016\/j.prosdent.2025.02.017"},{"issue":"Suppl 1","key":"9507_CR7","first-page":"121","volume":"10","author":"J Katsoulis","year":"2017","unstructured":"Katsoulis J, Takeichi T, Sol Gaviria A, Peter L, Katsoulis K. Misfit of implant prostheses and its impact on clinical outcomes: definition, assessment and a systematic review of the literature. Eur J Oral Implantol. 2017;10(Suppl 1):121\u201338.","journal-title":"Eur J Oral Implantol"},{"key":"9507_CR8","first-page":"620","volume":"11","author":"T Jemt","year":"1996","unstructured":"Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants. 1996;11:620\u20135.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"9507_CR9","doi-asserted-by":"publisher","first-page":"70","DOI":"10.4047\/jap.2025.17.2.70","volume":"17","author":"FD Boz","year":"2025","unstructured":"Boz FD, Akca K. Comparison of fixed dental prostheses digitally fabricated using various scan bodies: a clinical study. J Adv Prosthodont. 2025;17:70.","journal-title":"J Adv Prosthodont"},{"key":"9507_CR10","doi-asserted-by":"publisher","first-page":"1428","DOI":"10.1186\/s12903-024-05199-1","volume":"24","author":"MHA Tawfik","year":"2024","unstructured":"Tawfik MHA, El Torky IR, El Sheikh MM. Effect of saliva on accuracy of digital dental implant transfer using two different materials of intraoral scan bodies with different exposed lengths. BMC Oral Health. 2024;24:1428.","journal-title":"BMC Oral Health"},{"key":"9507_CR11","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/j.prosdent.2017.10.029","volume":"120","author":"RM Mizumoto","year":"2018","unstructured":"Mizumoto RM, Yilmaz B. Intraoral scan bodies in implant dentistry: a systematic review. J Prosthet Dent. 2018;120:343\u201352.","journal-title":"J Prosthet Dent"},{"key":"9507_CR12","doi-asserted-by":"publisher","first-page":"865","DOI":"10.1016\/j.prosdent.2022.02.024","volume":"131","author":"HR Haghi","year":"2024","unstructured":"Haghi HR, Ghanbarzadeh J, Kiamanesh E. A randomized clinical trial comparing the clinical fit and chairside adjustment time for implant-supported crowns fabricated by fully digital and partially digital techniques. J Prosthet Dent. 2024;131:865\u201370.","journal-title":"J Prosthet Dent"},{"key":"9507_CR13","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1111\/clr.13951","volume":"33","author":"A Schmidt","year":"2022","unstructured":"Schmidt A, W\u00f6stmann B, Schlenz MA. Accuracy of digital implant impressions in clinical studies: a systematic review. Clin Oral Implants Res. 2022;33:573\u201385.","journal-title":"Clin Oral Implants Res"},{"key":"9507_CR14","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/j.prosdent.2013.07.010","volume":"111","author":"FS Andriessen","year":"2014","unstructured":"Andriessen FS, Rijkens DR, van der Meer WJ, Wismeijer DW. Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: a pilot study. J Prosthet Dent. 2014;111:186\u201394.","journal-title":"J Prosthet Dent"},{"key":"9507_CR15","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1111\/jopr.13162","volume":"29","author":"K Chochlidakis","year":"2020","unstructured":"Chochlidakis K, Papaspyridakos P, Tsigarida A, Romeo D, Chen Y, Natto Z, et al. Digital versus conventional full-arch implant impressions: a prospective study on 16 edentulous maxillae. J Prosthodont. 2020;29:281\u20136.","journal-title":"J Prosthodont"},{"key":"9507_CR16","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.prosdent.2019.09.022","volume":"124","author":"M G\u00f3mez-Polo","year":"2020","unstructured":"G\u00f3mez-Polo M, Ballesteros J, Perales-Padilla P, Perales-Pulido P, G\u00f3mez-Polo C, Ortega R. Guided implant scanning: a procedure for improving the accuracy of implant-supported complete-arch fixed dental prostheses. J Prosthet Dent. 2020;124:135\u20139.","journal-title":"J Prosthet Dent"},{"key":"9507_CR17","doi-asserted-by":"publisher","first-page":"1010","DOI":"10.1111\/clr.13982","volume":"33","author":"FR Kernen","year":"2022","unstructured":"Kernen FR, Recca M, Vach K, Nahles S, Nelson K, Fl\u00fcgge TV. In vitro scanning accuracy using different aids for multiple implants in the edentulous arch. Clin Oral Implants Res. 2022;33:1010\u201320.","journal-title":"Clin Oral Implants Res"},{"key":"9507_CR18","doi-asserted-by":"publisher","first-page":"844","DOI":"10.1016\/j.prosdent.2021.08.018","volume":"129","author":"A Paratelli","year":"2023","unstructured":"Paratelli A, Vania S, G\u00f3mez-Polo C, Ortega R, Revilla-Le\u00f3n M, G\u00f3mez-Polo M. Techniques to improve the accuracy of complete arch implant intraoral digital scans: a systematic review. J Prosthet Dent. 2023;129:844\u201354.","journal-title":"J Prosthet Dent"},{"key":"9507_CR19","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.prosdent.2023.06.015","volume":"132","author":"L Azevedo","year":"2024","unstructured":"Azevedo L, Marques T, Karasan D, Fehmer V, Sailer I, Correia A, et al. Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners. J Prosthet Dent. 2024;132:204\u201310.","journal-title":"J Prosthet Dent"},{"key":"9507_CR20","doi-asserted-by":"crossref","unstructured":"Ali K, Alzaid AA, Suprono MS, Garbacea A, Savignano R, Kattadiyil MT. Evaluating the effects of splinting implant scan bodies intraorally on the trueness of complete arch digital scans: a clinical study. J Prosthet Dent. 2024;132:781.e1-781.e7.","DOI":"10.1016\/j.prosdent.2024.03.004"},{"key":"9507_CR21","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1186\/s12903-024-04157-1","volume":"24","author":"BSG Eldin","year":"2024","unstructured":"Eldin BSG, Talaat IA, Nawar NHH, Mohamed AMA. Effect of different fabrication workflows on the passive fit of screw-retained bar splinting two interforaminal implants: a parallel blinded randomised clinical trial. BMC Oral Health. 2024;24:410.","journal-title":"BMC Oral Health"},{"key":"9507_CR22","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1111\/jopr.13630","volume":"32","author":"P Papaspyridakos","year":"2023","unstructured":"Papaspyridakos P, Vazouras K, Gotsis S, Bokhary A, Sicilia E, Kudara Y, et al. Complete digital workflow for prosthesis prototype fabrication with double digital scanning: a retrospective study with 45 edentulous jaws. J Prosthodont. 2023;32:571\u20138.","journal-title":"J Prosthodont"},{"key":"9507_CR23","doi-asserted-by":"publisher","first-page":"104307","DOI":"10.1016\/j.jdent.2022.104307","volume":"127","author":"M G\u00f3mez-Polo","year":"2022","unstructured":"G\u00f3mez-Polo M, Ortega R, Sallorenzo A, Agust\u00edn-Panadero R, Barmak AB, Kois JC, et al. Influence of the surface humidity, implant angulation, and interimplant distance on the accuracy and scanning time of complete-arch implant scans. J Dent. 2022;127:104307.","journal-title":"J Dent"},{"key":"9507_CR24","doi-asserted-by":"publisher","first-page":"104122","DOI":"10.1016\/j.jdent.2022.104122","volume":"121","author":"M G\u00f3mez-Polo","year":"2022","unstructured":"G\u00f3mez-Polo M, \u00c1lvarez F, Ortega R, G\u00f3mez-Polo C, Barmak AB, Kois JC, et al. Influence of the implant scan body bevel location, implant angulation and position on intraoral scanning accuracy: an in vitro study. J Dent. 2022;121:104122.","journal-title":"J Dent"},{"key":"9507_CR25","first-page":"882","volume":"33","author":"P Papaspyridakos","year":"2024","unstructured":"Papaspyridakos P, Castellanos L, Bedrossian EA, Romeo D, Kudara Y, Chochlidakis K. Reverse scan body: complete digital workflow for double full-arch zirconia prostheses. J Prosthodont. 2024;33:882\u20138.","journal-title":"J Prosthodont"},{"key":"9507_CR26","doi-asserted-by":"publisher","first-page":"104717","DOI":"10.1016\/j.jdent.2023.104717","volume":"138","author":"P Nuytens","year":"2023","unstructured":"Nuytens P, Vandeweghe S, D\u2019haese R. Accuracy of a chairside reverse scanbody workflow for a complete arch implant-supported prosthesis using four intraoral scanners versus a desktop scanner. J Dent. 2023;138:104717.","journal-title":"J Dent"},{"key":"9507_CR27","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1111\/jopr.13664","volume":"32","author":"P Papaspyridakos","year":"2023","unstructured":"Papaspyridakos P, Bedrossian A, Kudara Y, Ntovas P, Bokhary A, Chochlidakis K. Reverse scan body: a complete digital workflow for prosthesis prototype fabrication. J Prosthodont. 2023;32:452\u20137.","journal-title":"J Prosthodont"},{"issue":"Suppl 2","key":"9507_CR28","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1111\/jopr.13772","volume":"32","author":"P Papaspyridakos","year":"2023","unstructured":"Papaspyridakos P, Bedrossian EA, Ntovas P, Kudara Y, Bokhary A, Chochlidakis K. Reverse scan body: the scan pattern affects the fit of complete-arch prototype prostheses. J Prosthodont. 2023;32(Suppl 2):186\u201391.","journal-title":"J Prosthodont"},{"key":"9507_CR29","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1563\/aaid-joi-D-24-00083","volume":"51","author":"PN Nguyen","year":"2025","unstructured":"Nguyen PN, Tran LH, Hoang V. Full-arch implant-supported rehabilitation using reverse scan technique: a case report. J Oral Implantol. 2025;51:74\u20139.","journal-title":"J Oral Implantol"},{"key":"9507_CR30","doi-asserted-by":"publisher","first-page":"1444","DOI":"10.1111\/clr.13844","volume":"32","author":"V Rutkunas","year":"2021","unstructured":"Rutkunas V, Gedrimiene A, Akulauskas M, Fehmer V, Sailer I, Jegelevicius D. In vitro and in vivo accuracy of full-arch digital implant impressions. Clin Oral Implants Res. 2021;32:1444\u201354.","journal-title":"Clin Oral Implants Res"},{"key":"9507_CR31","first-page":"550","volume":"13","author":"A Gintaute","year":"2018","unstructured":"Gintaute A, Papatriantafyllou N, Aljehani M, Att W. Accuracy of computerized and conventional impression-making procedures for multiple straight and tilted dental implants. Int J Esthet Dent. 2018;13:550\u201365.","journal-title":"Int J Esthet Dent"},{"key":"9507_CR32","doi-asserted-by":"publisher","first-page":"105559","DOI":"10.1016\/j.jdent.2025.105559","volume":"153","author":"A Kernen-Gintaute","year":"2025","unstructured":"Kernen-Gintaute A, Akulauskas M, Kernen F, Zitzmann NU, Spies BC, Burkhardt F. Accuracy of digital and conventional implant impressions in edentulous jaws: a clinical comparative study. J Dent. 2025;153:105559.","journal-title":"J Dent"},{"key":"9507_CR33","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1111\/jopr.13536","volume":"32","author":"P Papaspyridakos","year":"2023","unstructured":"Papaspyridakos P, De Souza A, Finkelman M, Sicilia E, Gotsis S, Chen Y, et al. Digital vs conventional full-arch implant impressions: a retrospective analysis of 36 edentulous jaws. J Prosthodont. 2023;32:325\u201330.","journal-title":"J Prosthodont"},{"key":"9507_CR34","doi-asserted-by":"publisher","first-page":"1310","DOI":"10.1016\/j.prosdent.2021.02.039","volume":"128","author":"AL Carneiro Pereira","year":"2022","unstructured":"Carneiro Pereira AL, Carvalho Porto de Freitas RF, de F\u00e1tima Trindade Pinto Campos M, Soares Paiva T\u00f4rres AC. Bezerra de Medeiros AK, da Fonte Porto Carreiro A. Trueness of a device for intraoral scanning to capture the angle and distance between implants in edentulous mandibular arches. J Prosthet Dent. 2022;128:1310\u20137.","journal-title":"J Prosthet Dent"},{"key":"9507_CR35","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1016\/j.prosdent.2021.09.035","volume":"130","author":"YJ Zhang","year":"2023","unstructured":"Zhang YJ, Qian SJ, Lai HC, Shi JY. Accuracy of photogrammetric imaging versus conventional impressions for complete arch implant-supported fixed dental prostheses: a comparative clinical study. J Prosthet Dent. 2023;130:212\u20138.","journal-title":"J Prosthet Dent"},{"key":"9507_CR36","first-page":"1","volume":"31","author":"V Rutk\u016bnas","year":"2023","unstructured":"Rutk\u016bnas V, Gedrimien\u0117 A, Mischitz I, Mijiritsky E, Huber S. EPA Consensus Project Paper: accuracy of photogrammetry devices, intraoral scanners, and conventional techniques for the full-arch implant impressions: a systematic review. Eur J Prosthodont Restor Dent. 2023;31:1\u201310.","journal-title":"Eur J Prosthodont Restor Dent"},{"key":"9507_CR37","doi-asserted-by":"publisher","first-page":"1253","DOI":"10.1007\/s00784-017-2217-9","volume":"22","author":"M Menini","year":"2018","unstructured":"Menini M, Setti P, Pera F, Pera P, Pesce P. Accuracy of multi-unit implant impression: traditional techniques versus a digital procedure. Clin Oral Investig. 2018;22:1253\u201362.","journal-title":"Clin Oral Investig"},{"key":"9507_CR38","doi-asserted-by":"publisher","first-page":"104636","DOI":"10.1016\/j.jdent.2023.104636","volume":"137","author":"V Vitai","year":"2023","unstructured":"Vitai V, N\u00e9meth A, S\u00f3lyom E, Czumbel LM, Szab\u00f3 B, Fazekas R, et al. Evaluation of the accuracy of intraoral scanners for complete-arch scanning: a systematic review and network meta-analysis. J Dent. 2023;137:104636.","journal-title":"J Dent"},{"key":"9507_CR39","doi-asserted-by":"publisher","first-page":"104138","DOI":"10.1016\/j.jdent.2022.104138","volume":"121","author":"G Ochoa-L\u00f3pez","year":"2022","unstructured":"Ochoa-L\u00f3pez G, Cascos R, Antonaya-Mart\u00edn JL, Revilla-Le\u00f3n M, G\u00f3mez-Polo M. Influence of ambient light conditions on the accuracy and scanning time of seven intraoral scanners in complete-arch implant scans. J Dent. 2022;121:104138.","journal-title":"J Dent"},{"key":"9507_CR40","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1111\/jerd.12985","volume":"35","author":"M Revilla-Le\u00f3n","year":"2023","unstructured":"Revilla-Le\u00f3n M, Kois DE, Kois JC. A guide for maximizing the accuracy of intraoral digital scans. Part 1: operator factors. J Esthet Restor Dent. 2023;35:230\u201340.","journal-title":"J Esthet Restor Dent"},{"issue":"Suppl 2","key":"9507_CR41","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1111\/jopr.13749","volume":"32","author":"M Revilla-Le\u00f3n","year":"2023","unstructured":"Revilla-Le\u00f3n M, Lanis A, Yilmaz B, Kois JC, Gallucci GO. Intraoral digital implant scans: parameters to improve accuracy. J Prosthodont. 2023;32(Suppl 2):150\u201364.","journal-title":"J Prosthodont"},{"key":"9507_CR42","doi-asserted-by":"publisher","first-page":"102","DOI":"10.11607\/jomi.3592","volume":"30","author":"WS Lin","year":"2015","unstructured":"Lin WS, Harris B, Elathamna E, Abdel-Azim T, Morton D. Effect of implant divergence on the accuracy of definitive casts created from traditional and digital implant-level impressions: an in vitro comparative study. Int J Oral Maxillofac Implants. 2015;30:102\u20139.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"9507_CR43","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1016\/j.jpor.2019.06.001","volume":"64","author":"L Arcuri","year":"2020","unstructured":"Arcuri L, Pozzi A, Lio F, Rompen E, Zechner W, Nardi A. Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: a randomized in vitro trial. J Prosthodont Res. 2020;64:128\u201336.","journal-title":"J Prosthodont Res"},{"key":"9507_CR44","first-page":"1","volume":"37","author":"LS Prott","year":"2024","unstructured":"Prott LS, Graham L, Gierthmuehlen PC, Blatz MB. In-vitro accuracy of digital versus conventional workflows for complete arch implant supported frameworks: a scoping review. Int J Prosthodont. 2024;37:1\u201324.","journal-title":"Int J Prosthodont"},{"key":"9507_CR45","doi-asserted-by":"publisher","first-page":"633","DOI":"10.2186\/jpr.JPR_D_22_00242","volume":"67","author":"Y Ma","year":"2023","unstructured":"Ma Y, Guo YQ, Jiang L, Yu H. Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses. J Prosthodont Res. 2023;67:633\u201340.","journal-title":"J Prosthodont Res"},{"key":"9507_CR46","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1111\/clr.14069","volume":"34","author":"M G\u00f3mez-Polo","year":"2023","unstructured":"G\u00f3mez-Polo M, Cascos R, Ortega R, Barmak AB, Kois JC, Revilla-Le\u00f3n M. Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete-arch intraoral digital implant scans. Clin Oral Implants Res. 2023;34:591\u2013601.","journal-title":"Clin Oral Implants Res"},{"key":"9507_CR47","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1111\/jerd.12993","volume":"35","author":"M Revilla-Le\u00f3n","year":"2023","unstructured":"Revilla-Le\u00f3n M, Kois DE, Kois JC. A guide for maximizing the accuracy of intraoral digital scans: Part 2\u2014patient factors. J Esthet Restor Dent. 2023;35:241\u20139.","journal-title":"J Esthet Restor Dent"},{"key":"9507_CR48","doi-asserted-by":"publisher","first-page":"105970","DOI":"10.1016\/j.jdent.2025.105970","volume":"161","author":"P Ntovas","year":"2025","unstructured":"Ntovas P, Ladia O, Barmak AB, Kois JC, Revilla-Le\u00f3n M. Influence of extraoral scan body design on accuracy of scans recorded using four intraoral and one desktop scanner, with and without AI features: an in vitro study. J Dent. 2025;161:105970.","journal-title":"J Dent"},{"key":"9507_CR49","doi-asserted-by":"publisher","first-page":"104741","DOI":"10.1016\/j.jdent.2023.104741","volume":"139","author":"M Klein","year":"2023","unstructured":"Klein M, Tuminelli FJ, Sallustio A, Giglio GD, Lerner H, Berg RW, et al. Full-arch restoration with the NEXUS IOS\u00ae system: a retrospective clinical evaluation of 37 restorations after a one year of follow-up. J Dent. 2023;139:104741.","journal-title":"J Dent"},{"key":"9507_CR50","doi-asserted-by":"publisher","first-page":"1136","DOI":"10.1111\/clr.14463","volume":"36","author":"L Azevedo","year":"2025","unstructured":"Azevedo L, Laureti A, Marques T, Pitta J, Fehmer V, Pozzi A, et al. Effect of horizontal and vertical intraoral scan bodies on the trueness of complete-arch digital implant impressions: a comparative in vitro study with six implants. Clin Oral Implants Res. 2025;36:1136\u201345.","journal-title":"Clin Oral Implants Res"},{"key":"9507_CR51","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.prosdent.2021.09.032","volume":"130","author":"V Rutk\u016bnas","year":"2023","unstructured":"Rutk\u016bnas V, Gedrimien\u0117 A, Al-Haj Husain N, Pletkus J, Barauskis D, Jegelevi\u010dius D, et al. Effect of additional reference objects on accuracy of five intraoral scanners in partially and completely edentulous jaws: an in vitro study. J Prosthet Dent. 2023;130:111\u20138.","journal-title":"J Prosthet Dent"},{"key":"9507_CR52","doi-asserted-by":"publisher","first-page":"636","DOI":"10.1186\/s12903-021-02005-0","volume":"21","author":"B Ma","year":"2021","unstructured":"Ma B, Yue X, Sun Y, Peng L, Geng W. Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study. BMC Oral Health. 2021;21:636.","journal-title":"BMC Oral Health"},{"key":"9507_CR53","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1111\/clr.14252","volume":"35","author":"J Cheng","year":"2024","unstructured":"Cheng J, Zhang H, Liu H, Li J, Wang HL, Tao X. Accuracy of edentulous full-arch implant impression: an in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry. Clin Oral Implants Res. 2024;35:560\u201372.","journal-title":"Clin Oral Implants Res"},{"key":"9507_CR54","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1016\/j.prosdent.2024.01.008","volume":"133","author":"M Revilla-Le\u00f3n","year":"2025","unstructured":"Revilla-Le\u00f3n M, G\u00f3mez-Polo M, Drone M, Barmak AB, Att W, Kois JC, et al. Influence of implant reference on the scanning accuracy of complete arch implant scans captured by using a photogrammetry system. J Prosthet Dent. 2025;133:252\u20137.","journal-title":"J Prosthet Dent"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-09507-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-09507-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-09507-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T13:03:11Z","timestamp":1788008591000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-09507-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,4]]},"references-count":54,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["9507"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-09507-9","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,4]]},"assertion":[{"value":"26 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Ethical responsibility for the study protocol at the Department of Reconstructive Dentistry, University Center for Dental Medicine, Basel, Switzerland was clarified by the Ethics Committee Northwest and Central Switzerland (EKNZ-ID 2021\u2009\u2212\u200900249). The participant provided written informed consent prior to being enrolled in the study and all procedures were conducted in accordance with the Declaration of Helsinki and applicable national regulations.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Written informed consent was obtained from the participant prior the inclusion in the study. The participant was informed about the study procedures and agreed to participate voluntarily.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"1628"}}