{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T16:55:02Z","timestamp":1791219302431,"version":"4.1.0"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T00:00:00Z","timestamp":1790899200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T00:00:00Z","timestamp":1791158400000},"content-version":"vor","delay-in-days":3,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Oral Health"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Directly 3D-printed aligner materials have recently emerged as an alternative to established thermoformed clear aligners. The aim of this in vitro study was to investigate the colour stability, water sorption, and water solubility of directly 3D-printed aligner materials in comparison with an established thermoformed reference, as these properties are essential for clinical performance but currently insufficiently investigated for directly 3D-printed aligners.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Tera Harz TC-85DAC, Freeprint Aligner, Freeprint Aligner with digital polishing, Dental LT Clear V2 and one thermoformed polyethylene terephthalate glycol material (Biolon) were examined. Water sorption and solubility were determined after seven days in distilled water at 37\u00a0\u00b0C. Colour stability was assessed after 12\u00a0h of immersion at 37\u00a0\u00b0C in turmeric, coffee, black tea, orange juice and distilled water. Total colour differences (\u0394E*) were calculated spectrophotometrically using the Commission Internationale de l\u2019\u00c9clairage L*a*b* system and converted into National Bureau of Standards units. Data were analysed by one-way ANOVA with Games-Howell post hoc test and by Kruskal-Wallis test with Dunn\u2019s test and Bonferroni correction (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Biolon exhibited the lowest water sorption (mean 10.70\u00a0\u00b5g\/mm\u00b3) and negligible solubility (median 0.00\u00a0\u00b5g\/mm\u00b3). Among the printed resins, Tera Harz TC-85DAC showed the lowest water sorption (mean 17.28\u00a0\u00b5g\/mm\u00b3) and solubility (median 2.50\u00a0\u00b5g\/mm\u00b3), whereas Dental LT Clear V2 displayed the highest sorption (mean 29.53\u00a0\u00b5g\/mm\u00b3) and Freeprint Aligner with digital polishing the highest solubility (median 17.38\u00a0\u00b5g\/mm\u00b3). Turmeric caused the most pronounced discolouration, followed by coffee and black tea, while orange juice and water produced minimal changes. The thermoformed material remained most colour-stable (mean of the median \u0394E* values across all immersion media\u2009=\u20094.21), whereas Dental LT Clear V2 showed the greatest discolouration (mean of the median \u0394E* values\u2009=\u200927.35). Among the printed resins, Tera Harz TC-85DAC displayed the lowest staining susceptibility.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The tested aligner materials differed markedly in water sorption, solubility, and colour stability. The thermoformed polyethylene terephthalate glycol material consistently showed the most favourable profile. Among the printed resins, Tera Harz TC-85DAC exhibited the most favourable combination of the investigated properties, supporting its potential for clinical application.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12903-026-09977-x","type":"journal-article","created":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T08:14:37Z","timestamp":1790928877000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Hygroscopic behaviour and colour stability of 3D-printed and thermoformed aligner materials: an in vitro study"],"prefix":"10.1186","volume":"26","author":[{"given":"Jule","family":"Kolb","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Wille","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oral Cenk","family":"Aktas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5907-5398","authenticated-orcid":false,"given":"Sinan","family":"\u015een","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kathrin","family":"Puchert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,2]]},"reference":[{"key":"9977_CR1","doi-asserted-by":"publisher","first-page":"3103","DOI":"10.3390\/jcm10143103","volume":"10","author":"LH Timm","year":"2021","unstructured":"Timm LH, Farrag G, Baxmann M, Schwendicke F. Factors Influencing Patient Compliance during Clear Aligner Therapy: A Retrospective Cohort Study. J Clin Med. 2021;10:3103. https:\/\/doi.org\/10.3390\/jcm10143103.","journal-title":"J Clin Med"},{"key":"9977_CR2","doi-asserted-by":"publisher","first-page":"109372","DOI":"10.1016\/j.identj.2025.109372","volume":"76","author":"J Wu","year":"2026","unstructured":"Wu J, Zhang J, Yu X, Jia Y, Wei X. Evolving Trends and Emerging Frontiers in Clear Aligner Therapy: A Bibliometric and Social Impact Analysis (2015\u20132024). Int Dent J. 2026;76:109372. https:\/\/doi.org\/10.1016\/j.identj.2025.109372.","journal-title":"Int Dent J"},{"key":"9977_CR3","doi-asserted-by":"publisher","first-page":"105616","DOI":"10.1016\/j.jdent.2025.105616","volume":"155","author":"T Torkomian","year":"2025","unstructured":"Torkomian T, de la Iglesia F, Puigdollers A. 3D-printed clear aligners: An emerging alternative to the conventional thermoformed aligners? - A systematic review. J Dent. 2025;155:105616. https:\/\/doi.org\/10.1016\/j.jdent.2025.105616.","journal-title":"J Dent"},{"key":"9977_CR4","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1053\/j.sodo.2024.08.005","volume":"32","author":"X Liao","year":"2026","unstructured":"Liao X, Huang F, Chen W, Cai X, Lu Y, Zhou Z. The thickness and gap width of aligners made of three types of thermoforming materials: An in-vitro study. Semin Orthod. 2026;32:261\u20138. https:\/\/doi.org\/10.1053\/j.sodo.2024.08.005.","journal-title":"Semin Orthod"},{"key":"9977_CR5","doi-asserted-by":"publisher","first-page":"10921","DOI":"10.1038\/s41598-023-36851-5","volume":"13","author":"SY Park","year":"2023","unstructured":"Park SY, Choi S-H, Yu H-S, Kim S-J, Kim H, Kim KB, et al. Comparison of translucency, thickness, and gap width of thermoformed and 3D-printed clear aligners using micro-CT and spectrophotometer. Sci Rep. 2023;13:10921. https:\/\/doi.org\/10.1038\/s41598-023-36851-5.","journal-title":"Sci Rep"},{"key":"9977_CR6","doi-asserted-by":"publisher","first-page":"19022","DOI":"10.1038\/s41598-025-04096-z","volume":"15","author":"L \u0160imunovi\u0107","year":"2025","unstructured":"\u0160imunovi\u0107 L, Pe\u010dani\u0107 P, Mari\u0107 AJ, Haramina T, Raki\u0107 I\u0160, Me\u0161trovi\u0107 S. Impact of various cleaning protocols on the physical and aesthetic properties of 3D-printed orthodontic aligners. Sci Rep. 2025;15:19022. https:\/\/doi.org\/10.1038\/s41598-025-04096-z.","journal-title":"Sci Rep"},{"key":"9977_CR7","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s40510-017-0178-9","volume":"18","author":"L Lombardo","year":"2017","unstructured":"Lombardo L, Martini M, Cervinara F, Spedicato GA, Oliverio T, Siciliani G. Comparative SEM analysis of nine F22 aligner cleaning strategies. Prog Orthod. 2017;18:26. https:\/\/doi.org\/10.1186\/s40510-017-0178-9.","journal-title":"Prog Orthod"},{"key":"9977_CR8","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/j.ajodo.2025.09.027","volume":"169","author":"T Lego","year":"2026","unstructured":"Lego T, Malhotra A, Batra P, Singh AK, Talwar A. Comparison of optical properties and color stability of 3-dimensional (3D) printed shape memory and thermoformed clear aligners: A single-center, prospective clinical trial study. Am J Orthod Dentofac Orthop. 2026;169:247\u201356. https:\/\/doi.org\/10.1016\/j.ajodo.2025.09.027.","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"9977_CR9","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.ajodo.2024.06.010","volume":"167","author":"SP Neoh","year":"2025","unstructured":"Neoh SP, Khantachawana A, Chintavalakorn R, Santiwong P, Srikhirin T. Comparison of physical, mechanical, and optical properties between thermoplastic materials and 3-dimensional printing resins for orthodontic clear retainers. Am J Orthod Dentofac Orthop. 2025;167:95\u2013e1091. https:\/\/doi.org\/10.1016\/j.ajodo.2024.06.010.","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"9977_CR10","doi-asserted-by":"publisher","first-page":"42","DOI":"10.3390\/dj10030042","volume":"10","author":"MM Gad","year":"2022","unstructured":"Gad MM, Alshehri SZ, Alhamid SA, Albarrak A, Khan SQ, Alshahrani FA, et al. Water Sorption, Solubility, and Translucency of 3D-Printed Denture Base Resins. Dent J (Basel). 2022;10:42. https:\/\/doi.org\/10.3390\/dj10030042.","journal-title":"Dent J (Basel)"},{"key":"9977_CR11","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1038\/ijos.2016.25","volume":"8","author":"C-L Liu","year":"2016","unstructured":"Liu C-L, Sun W-T, Liao W, Lu W-X, Li Q-W, Jeong Y, et al. Colour stabilities of three types of orthodontic clear aligners exposed to staining agents. Int J Oral Sci. 2016;8:246\u201353. https:\/\/doi.org\/10.1038\/ijos.2016.25.","journal-title":"Int J Oral Sci"},{"key":"9977_CR12","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1186\/s12903-025-06343-1","volume":"25","author":"C Kobkiatkawin","year":"2025","unstructured":"Kobkiatkawin C, Panyayong W, Suphangul S, Thiradilok S. Color stability of clear aligners exposed to various beverages: an in vitro study. BMC Oral Health. 2025;25:971. https:\/\/doi.org\/10.1186\/s12903-025-06343-1.","journal-title":"BMC Oral Health"},{"key":"9977_CR13","doi-asserted-by":"publisher","first-page":"316","DOI":"10.4041\/kjod.2018.48.5.316","volume":"48","author":"J-H Ryu","year":"2018","unstructured":"Ryu J-H, Kwon J-S, Jiang HB, Cha J-Y, Kim K-M. Effects of thermoforming on the physical and mechanical properties of thermoplastic materials for transparent orthodontic aligners. Korean J Orthod. 2018;48:316\u201325. https:\/\/doi.org\/10.4041\/kjod.2018.48.5.316.","journal-title":"Korean J Orthod"},{"key":"9977_CR14","doi-asserted-by":"publisher","first-page":"415","DOI":"10.4012\/dmj.2019-104","volume":"39","author":"S Inoue","year":"2020","unstructured":"Inoue S, Yamaguchi S, Uyama H, Yamashiro T, Imazato S. Influence of constant strain on the elasticity of thermoplastic orthodontic materials. Dent Mater J. 2020;39:415\u201321. https:\/\/doi.org\/10.4012\/dmj.2019-104.","journal-title":"Dent Mater J"},{"key":"9977_CR15","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.3390\/polym16081067","volume":"16","author":"L \u0160imunovi\u0107","year":"2024","unstructured":"\u0160imunovi\u0107 L, \u010cekalovi\u0107 Agovi\u0107 S, Mari\u0107 AJ, Ba\u010di\u0107 I, Klari\u0107 E, Uribe F, et al. Color and Chemical Stability of 3D-Printed and Thermoformed Polyurethane-Based Aligners. Polym (Basel). 2024;16:1067. https:\/\/doi.org\/10.3390\/polym16081067.","journal-title":"Polym (Basel)"},{"key":"9977_CR16","doi-asserted-by":"publisher","first-page":"101105","DOI":"10.1016\/j.ortho.2025.101105","volume":"24","author":"BP Perumalla","year":"2025","unstructured":"Perumalla BP, Kandikatla P, Bhupathi A, Manda A, Varma PK, Babu H. Assessing colour stability of direct printed and thermoformed aligners: An in vitro study on aesthetics longevity. Int Orthod. 2025;24:101105. https:\/\/doi.org\/10.1016\/j.ortho.2025.101105.","journal-title":"Int Orthod"},{"key":"9977_CR17","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1016\/j.ajodo.2025.04.022","volume":"168","author":"L \u0160imunovi\u0107","year":"2025","unstructured":"\u0160imunovi\u0107 L, Mili\u010devi\u0107 AM, Brenko L, Haramina T, Me\u0161trovi\u0107 S. Absorption and desorption dynamics of thermoformed and 3-dimensional-printed orthodontic aligners. Am J Orthod Dentofac Orthop. 2025;168:466\u201376. https:\/\/doi.org\/10.1016\/j.ajodo.2025.04.022.","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"9977_CR18","doi-asserted-by":"publisher","first-page":"694","DOI":"10.1016\/j.ajodo.2019.05.012","volume":"156","author":"P Jindal","year":"2019","unstructured":"Jindal P, Juneja M, Siena FL, Bajaj D, Breedon P. Mechanical and geometric properties of thermoformed and 3D printed clear dental aligners. Am J Orthod Dentofac Orthop. 2019;156:694\u2013701. https:\/\/doi.org\/10.1016\/j.ajodo.2019.05.012.","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"9977_CR19","doi-asserted-by":"publisher","first-page":"e91","DOI":"10.1016\/j.ajodo.2020.07.029","volume":"158","author":"A Edelmann","year":"2020","unstructured":"Edelmann A, English JD, Chen SJ, Kasper FK. Analysis of the thickness of 3-dimensional-printed orthodontic aligners. Am J Orthod Dentofac Orthop. 2020;158:e91\u20138. https:\/\/doi.org\/10.1016\/j.ajodo.2020.07.029.","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"9977_CR20","doi-asserted-by":"publisher","first-page":"21","DOI":"10.3390\/bioengineering13010021","volume":"13","author":"K Puchert","year":"2025","unstructured":"Puchert K, Ritzert P, Wille S, Naim J, \u015een S. Influence of Water Storage on the Mechanical Properties of 3D-Printed Aligners: An In Vitro Study. Bioeng (Basel). 2025;13:21. https:\/\/doi.org\/10.3390\/bioengineering13010021.","journal-title":"Bioeng (Basel)"},{"key":"9977_CR21","unstructured":"Dentistry. - Base polymers - Part 2: Orthodontic base polymers (ISO 20795-2:2013). dinmedia. https:\/\/www.dinmedia.de\/de\/norm\/din-en-iso-20795-2\/181046932. Accessed 26 Apr 2026."},{"key":"9977_CR22","doi-asserted-by":"publisher","first-page":"5165","DOI":"10.3390\/app13085165","volume":"13","author":"AT Albilali","year":"2023","unstructured":"Albilali AT, Baras BH, Aldosari MA. Evaluation of Water Sorption and Solubility and FTIR Spectroscopy of Thermoplastic Orthodontic Retainer Materials Subjected to Thermoforming and Thermocycling. Appl Sci (Basel). 2023;13:5165. https:\/\/doi.org\/10.3390\/app13085165.","journal-title":"Appl Sci (Basel)"},{"key":"9977_CR23","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1590\/2176-9451.19.4.114-121.oar","volume":"19","author":"CB de Oliveira","year":"2014","unstructured":"de Oliveira CB, Maia LGM, Santos-Pinto A, Gandini Junior LG. vitro study of color stability of polycrystalline and monocrystalline ceramic brackets. Dent Press J Orthod. 2014;19:114\u201321. https:\/\/doi.org\/10.1590\/2176-9451.19.4.114-121.oar.","journal-title":"Dent Press J Orthod"},{"key":"9977_CR24","doi-asserted-by":"publisher","first-page":"cjae047","DOI":"10.1093\/ejo\/cjae047","volume":"46","author":"T Domingo-Jim\u00e9nez","year":"2024","unstructured":"Domingo-Jim\u00e9nez T, Gonz\u00e1lez-Olmo MJ, Nieto-Moraleda C, P\u00e9rez-Chicharro M, Romero-Maroto M. Colourimetric changes experienced in three types of aligners according to the L\u2019Eclairage Commission. Eur J Orthod. 2024;46:cjae047. https:\/\/doi.org\/10.1093\/ejo\/cjae047.","journal-title":"Eur J Orthod"},{"key":"9977_CR25","doi-asserted-by":"publisher","first-page":"2041","DOI":"10.1038\/s41598-025-85293-8","volume":"15","author":"N Ajwa","year":"2025","unstructured":"Ajwa N, Radhi F, Aloraini R, AlSaydalani G. Comparative color stability assessment of orthodontic clear aligners: an in vitro study. Sci Rep. 2025;15:2041. https:\/\/doi.org\/10.1038\/s41598-025-85293-8.","journal-title":"Sci Rep"},{"key":"9977_CR26","doi-asserted-by":"publisher","first-page":"cjad074","DOI":"10.1093\/ejo\/cjad074","volume":"46","author":"M Mattle","year":"2024","unstructured":"Mattle M, Zinelis S, Polychronis G, Makou O, Panayi N, Papageorgiou SN, et al. Effect of heat treatment and nitrogen atmosphere during post-curing on mechanical properties of 3D-printed orthodontic aligners. Eur J Orthod. 2024;46:cjad074. https:\/\/doi.org\/10.1093\/ejo\/cjad074.","journal-title":"Eur J Orthod"},{"key":"9977_CR27","doi-asserted-by":"publisher","first-page":"1776","DOI":"10.3390\/polym17131776","volume":"17","author":"S Bor","year":"2025","unstructured":"Bor S, Kaya Y, Demiral A, G\u00fcng\u00f6rm\u00fc\u015f M. Post-Process Cytotoxicity of Resins in Clear Aligner Fabrication. Polym (Basel). 2025;17:1776. https:\/\/doi.org\/10.3390\/polym17131776.","journal-title":"Polym (Basel)"},{"key":"9977_CR28","doi-asserted-by":"publisher","first-page":"477","DOI":"10.4041\/kjod25.132","volume":"55","author":"R Bandi\u0107","year":"2025","unstructured":"Bandi\u0107 R, Kekez IV, Stranput KV, Brali\u0107 N, \u010culi\u0107 V\u010c, Miki\u0107 IM, et al. Cytotoxic effect of 3D-printed and thermoformed clear aligner materials on human oral fibroblasts: An in vitro study. Korean J Orthod. 2025;55:477\u201386. https:\/\/doi.org\/10.4041\/kjod25.132.","journal-title":"Korean J Orthod"},{"key":"9977_CR29","unstructured":"dx 3D Guide. https:\/\/www.detax.com\/fileadmin\/Content\/Dental\/Documents\/Other\/3D_Guides_Dental\/dx_3D-Guide_GB.pdf. Accessed 26 Apr 2026."},{"key":"9977_CR30","unstructured":"Safety data sheet in accordance with regulation (EC) No 1907\/2006. 2024. https:\/\/dentamid.dreve.de\/fileadmin\/medienablage\/Dentamid\/Downloads\/daten\/enu_dentamid_sds_biolon_2231_gb.pdf?expired=1777190891. Accessed 26 Apr 2026."},{"key":"9977_CR31","unstructured":"Graphy Inc. 3D Printable Shape Memory Aligners & Dental Solutions. https:\/\/itgraphy.com. Accessed 25 Apr 2026."},{"key":"9977_CR32","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1186\/s40510-025-00600-3","volume":"26","author":"DD-S Chen","year":"2025","unstructured":"Chen DD-S, Peng T-Y, Huang P-Y, Kaku M, Cheng JH-C. Advances in clear aligner therapy: comparative evaluation of the optical properties and bacterial adhesion of 3D direct-printed and thermoformed aligners. Prog Orthod. 2025;26:53. https:\/\/doi.org\/10.1186\/s40510-025-00600-3.","journal-title":"Prog Orthod"},{"key":"9977_CR33","doi-asserted-by":"publisher","first-page":"221","DOI":"10.34172\/joddd.2022.035","volume":"16","author":"P Venkatasubramanian","year":"2022","unstructured":"Venkatasubramanian P, Jerome MS, Ragunanthanan L, Maheshwari U, Vijayalakshmi D. Color stability of aligner materials on exposure to indigenous food products: An in-vitro study. J Dent Res Dent Clin Dent Prospects. 2022;16:221\u20138. https:\/\/doi.org\/10.34172\/joddd.2022.035.","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"key":"9977_CR34","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/S0109-5641(87)80081-7","volume":"3","author":"IE Ruyter","year":"1987","unstructured":"Ruyter IE, Nilner K, M\u00f6ller B. Color stability of dental composite resin materials for crown and bridge veneers. Dent Mater. 1987;3:246\u201351. https:\/\/doi.org\/10.1016\/S0109-5641(87)80081-7.","journal-title":"Dent Mater"},{"key":"9977_CR35","doi-asserted-by":"publisher","first-page":"77","DOI":"10.3390\/jcs9020077","volume":"9","author":"M Patel","year":"2025","unstructured":"Patel M, Lee J, Hayashi M, Kim RH, Kim M. Effect of Turmeric Staining and Bleaching Treatment on Color Stability and Surface Hardness of Different Dental Composite Resins. J Compos Sci. 2025;9:77. https:\/\/doi.org\/10.3390\/jcs9020077.","journal-title":"J Compos Sci"},{"key":"9977_CR36","doi-asserted-by":"publisher","first-page":"14","DOI":"10.3390\/polym14010014","volume":"14","author":"V Daniele","year":"2022","unstructured":"Daniele V, Macera L, Taglieri G, Spera L, Marzo G, Quinzi V. Color Stability, Chemico-Physical and Optical Features of the Most Common PETG and PU Based Orthodontic Aligners for Clear Aligner Therapy. Polymers. 2022;14:14. https:\/\/doi.org\/10.3390\/polym14010014.","journal-title":"Polymers"},{"key":"9977_CR37","doi-asserted-by":"publisher","first-page":"355","DOI":"10.2319\/081624-672.1","volume":"95","author":"C Wu","year":"2025","unstructured":"Wu C, Mangal U, Bai N, Kim H, Hwang G, Cha J-Y, et al. Effects of printing layer thickness and build orientation on the mechanical properties and color stability of 3D-printed clear aligners. Angle Orthod. 2025;95:355\u201361. https:\/\/doi.org\/10.2319\/081624-672.1.","journal-title":"Angle Orthod"},{"key":"9977_CR38","doi-asserted-by":"publisher","first-page":"1940","DOI":"10.1111\/jerd.13476","volume":"37","author":"SR Rueda","year":"2025","unstructured":"Rueda SR, Sepsick H, Hammamy M, Nejat AH, Kee E, Lawson NC. The Effect of Different Surface Treatments on the Roughness, Translucency, and Staining of 3D-Printed Occlusal Device Materials. J Esthet Restor Dent. 2025;37:1940\u20138. https:\/\/doi.org\/10.1111\/jerd.13476.","journal-title":"J Esthet Restor Dent"},{"key":"9977_CR39","doi-asserted-by":"publisher","first-page":"340","DOI":"10.3390\/healthcare10020340","volume":"10","author":"C Charavet","year":"2022","unstructured":"Charavet C, Gourdain Z, Graveline L, Lupi L. Cleaning and Disinfection Protocols for Clear Orthodontic Aligners: A Systematic Review. Healthc (Basel). 2022;10:340. https:\/\/doi.org\/10.3390\/healthcare10020340.","journal-title":"Healthc (Basel)"},{"key":"9977_CR40","unstructured":"ISO\/TR 28642. 2016, Dentistry - Guidance on colour measurement. ISO. https:\/\/www.iso.org\/standard\/69046.html. Accessed 1 Sept 2026."},{"key":"9977_CR41","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.prosdent.2015.07.001","volume":"115","author":"C G\u00f3mez-Polo","year":"2016","unstructured":"G\u00f3mez-Polo C, Portillo Mu\u00f1oz M, Lorenzo Luengo MC, Vicente P, Galindo P, Mart\u00edn Casado AM. Comparison of the CIELab and CIEDE2000 color difference formulas. J Prosthet Dent. 2016;115:65\u201370. https:\/\/doi.org\/10.1016\/j.prosdent.2015.07.001.","journal-title":"J Prosthet Dent"}],"container-title":["BMC Oral Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12903-026-09977-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-09977-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12903-026-09977-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T16:03:46Z","timestamp":1791216226000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12903-026-09977-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,2]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["9977"],"URL":"https:\/\/doi.org\/10.1186\/s12903-026-09977-x","relation":{},"ISSN":["1472-6831"],"issn-type":[{"value":"1472-6831","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,2]]},"assertion":[{"value":"15 July 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 October 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"1922"}}