{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T01:05:03Z","timestamp":1784595903488,"version":"3.55.0"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T00:00:00Z","timestamp":1779753600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"vor","delay-in-days":56,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100005762","name":"National Taiwan University Hospital","doi-asserted-by":"crossref","award":["NTUH.109-S4743"],"award-info":[{"award-number":["NTUH.109-S4743"]}],"id":[{"id":"10.13039\/501100005762","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Educ"],"DOI":"10.1186\/s12909-026-09524-w","type":"journal-article","created":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T01:04:11Z","timestamp":1779757451000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The educational effectiveness in flexible bronchoscopic intubation training using three-dimensional printed difficult airway models for anaesthesia residents: a single centre randomised controlled study"],"prefix":"10.1186","volume":"26","author":[{"given":"Chen-Tse","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuang-Fang","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chia-Wei","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei-Hsuan","family":"Tai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chun-Yu","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yen-Yuan","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei-Zen","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuang-Cheng","family":"Chan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,26]]},"reference":[{"issue":"3","key":"9524_CR1","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1097\/EJA.0b013e32836590a7","volume":"31","author":"CH Jepsen","year":"2014","unstructured":"Jepsen CH, Gatke MR, Thogersen B, Mollerup LT, Ruhnau B, Rewers M, Rosenstock CV. Tracheal intubation with a flexible fibreoptic scope or the McGrath videolaryngoscope in simulated difficult airway scenarios: a randomised controlled manikin study. Eur J Anaesthesiol. 2014;31(3):131\u20136.","journal-title":"Eur J Anaesthesiol"},{"issue":"1","key":"9524_CR2","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1097\/ALN.0000000000004002","volume":"136","author":"JL Apfelbaum","year":"2022","unstructured":"Apfelbaum JL, Hagberg CA, Connis RT, Abdelmalak BB, Agarkar M, Dutton RP, Fiadjoe JE, Greif R, Klock PA, Mercier D, et al. 2022 American Society of Anesthesiologists Practice Guidelines for Management of the Difficult Airway. Anesthesiology. 2022;136(1):31\u201381.","journal-title":"Anesthesiology"},{"issue":"1","key":"9524_CR3","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1007\/s00540-015-2091-z","volume":"30","author":"RKL Bautista","year":"2016","unstructured":"Bautista RKL, Duan A, Neamtu X, Wu A, Wadhwa D, Akca A. Teaching basic fiberoptic intubation skills in a simulator: initial learning and skills decay. J Anesth. 2016;30(1):12\u20139.","journal-title":"J Anesth"},{"issue":"9","key":"9524_CR4","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1097\/EJA.0000000000000092","volume":"32","author":"PM Nilsson","year":"2015","unstructured":"Nilsson PM, Russell L, Ringsted C, Hertz P, Konge L. Simulation-based training in flexible fibreoptic intubation: A randomised study. Eur J Anaesthesiol. 2015;32(9):609\u201314.","journal-title":"Eur J Anaesthesiol"},{"issue":"1","key":"9524_CR5","doi-asserted-by":"publisher","first-page":"10631","DOI":"10.1038\/s41598-020-67575-5","volume":"10","author":"J Ock","year":"2020","unstructured":"Ock J, Gwon E, Kim D-h, Kim S-h, Kim N. Patient-specific and hyper-realistic phantom for an intubation simulator with a replaceable difficult airway of a toddler using 3D printing. Sci Rep. 2020;10(1):10631.","journal-title":"Sci Rep"},{"issue":"3","key":"9524_CR6","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1177\/0310057X20925827","volume":"48","author":"JC Carter","year":"2020","unstructured":"Carter JC, Broadbent J, Murphy EC, Guy B, Baguley KE, Young J. A three-dimensional (3D) printed paediatric trachea for airway management training. Anaesth Intensive Care. 2020;48(3):243\u20135.","journal-title":"Anaesth Intensive Care"},{"key":"9524_CR7","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/s12871-015-0170-1","volume":"16","author":"B Han","year":"2016","unstructured":"Han B, Liu Y, Zhang X, Wang J. Three-dimensional printing as an aid to airway evaluation after tracheotomy in a patient with laryngeal carcinoma. BMC Anesthesiol. 2016;16:6.","journal-title":"BMC Anesthesiol"},{"issue":"4","key":"9524_CR8","doi-asserted-by":"publisher","first-page":"e357","DOI":"10.1016\/j.athoracsur.2016.09.082","volume":"103","author":"N Guibert","year":"2017","unstructured":"Guibert N, Moreno B, Plat G, Didier A, Mazieres J, Hermant C. Stenting of Complex Malignant Central-Airway Obstruction Guided by a Three-Dimensional Printed Model Of The Airways. Ann Thorac Surg. 2017;103(4):e357\u20139.","journal-title":"Ann Thorac Surg"},{"issue":"8","key":"9524_CR9","doi-asserted-by":"publisher","first-page":"1474","DOI":"10.1053\/j.jvca.2023.04.009","volume":"37","author":"N Malackany","year":"2023","unstructured":"Malackany N, Londono I, Bustamante S, Dahan YJ, Bribriesco AC, Klatte R, Mehta A. Successful Management of Previously Failed Difficult Airway Using a 3D Printed Airway Model. J Cardiothorac Vasc Anesth. 2023;37(8):1474\u20137.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"2","key":"9524_CR10","doi-asserted-by":"publisher","first-page":"e65","DOI":"10.1016\/j.bjoms.2020.08.045","volume":"59","author":"D Ormandy","year":"2021","unstructured":"Ormandy D, Kolb B, Jayaram S, Burley O, Kyzas P, Vallance H, Vassiliou L. Difficult airways: a 3D printing study with virtual fibreoptic endoscopy. Br J Oral Maxillofac Surg. 2021;59(2):e65\u201371.","journal-title":"Br J Oral Maxillofac Surg"},{"issue":"5","key":"9524_CR11","doi-asserted-by":"publisher","first-page":"e085503","DOI":"10.1136\/bmjopen-2024-085503","volume":"14","author":"L Li","year":"2024","unstructured":"Li L, Zhu Y, Yin F, Yu H, Wang H, Xu Y, Fei F, Liu W, Duan B, Wang F, et al. Effect of a 3D-printed reconstruction automated matching system for selecting the size of a left double-lumen tube: a study protocol for a prospective randomised controlled trial. BMJ Open. 2024;14(5):e085503.","journal-title":"BMJ Open"},{"issue":"11","key":"9524_CR12","doi-asserted-by":"publisher","first-page":"e0207445","DOI":"10.1371\/journal.pone.0207445","volume":"13","author":"SH Kim","year":"2018","unstructured":"Kim SH, Kwon J, Kim YJ, Lee HJ, Seo HC, Lim SB, Joo S, Seo DW, Kim WY, Hong SB. Impact of a custom-made 3D printed ergonomic grip for direct laryngoscopy on novice intubation performance in a simulated easy and difficult airway scenario-A manikin study. PLoS ONE. 2018;13(11):e0207445.","journal-title":"PLoS ONE"},{"issue":"1","key":"9524_CR13","doi-asserted-by":"publisher","first-page":"e12626","DOI":"10.2196\/12626","volume":"5","author":"L Park","year":"2019","unstructured":"Park L, Price-Williams S, Jalali A, Pirzada K. Increasing Access to Medical Training With Three-Dimensional Printing: Creation of an Endotracheal Intubation Model. JMIR Med Educ. 2019;5(1):e12626.","journal-title":"JMIR Med Educ"},{"issue":"5","key":"9524_CR14","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1111\/anae.13812","volume":"72","author":"I Chao","year":"2017","unstructured":"Chao I, Young J, Coles-Black J, Chuen J, Weinberg L, Rachbuch C. The application of three-dimensional printing technology in anaesthesia: a systematic review. Anaesthesia. 2017;72(5):641\u201350.","journal-title":"Anaesthesia"},{"issue":"2","key":"9524_CR15","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1097\/00000542-200108000-00014","volume":"95","author":"VN Naik","year":"2001","unstructured":"Naik VN, Matsumoto ED, Houston PL, Hamstra SJ, Yeung RY, Mallon JS, Martire TM. Fiberoptic orotracheal intubation on anesthetized patients: do manipulation skills learned on a simple model transfer into the operating room? Anesthesiology. 2001;95(2):343\u20138.","journal-title":"Anesthesiology"},{"issue":"3","key":"9524_CR16","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1016\/j.jclinane.2005.08.021","volume":"18","author":"K Goldmann","year":"2006","unstructured":"Goldmann K, Steinfeldt T. Acquisition of basic fiberoptic intubation skills with a virtual reality airway simulator. J Clin Anesth. 2006;18(3):173\u20138.","journal-title":"J Clin Anesth"},{"issue":"6","key":"9524_CR17","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1097\/ALN.0b013e31818d6c3c","volume":"109","author":"DB Chandra","year":"2008","unstructured":"Chandra DB, Savoldelli GL, Joo HS, Weiss ID, Naik VN. Fiberoptic oral intubation: the effect of model fidelity on training for transfer to patient care. Anesthesiology. 2008;109(6):1007\u201313.","journal-title":"Anesthesiology"},{"issue":"Suppl 1","key":"9524_CR18","doi-asserted-by":"publisher","first-page":"i87","DOI":"10.1093\/bja\/aew059","volume":"117","author":"PA Baker","year":"2016","unstructured":"Baker PA, Weller JM, Baker MJ, Hounsell GL, Scott J, Gardiner PJ, Thompson JM. Evaluating the ORSIM\u00ae simulator for assessment of anaesthetists\u2019 skills in flexible bronchoscopy: aspects of validity and reliability. Br J Anaesth. 2016;117(Suppl 1):i87\u201391.","journal-title":"Br J Anaesth"},{"issue":"1","key":"9524_CR19","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1186\/s12871-020-01121-8","volume":"20","author":"MW van Emden","year":"2020","unstructured":"van Emden MW, Geurts JJG, Schober P, Schwarte LA. Suitability and realism of the novel Fix for Life cadaver model for videolaryngoscopy and fibreoptic tracheoscopy in airway management training. BMC Anesthesiol. 2020;20(1):203.","journal-title":"BMC Anesthesiol"},{"issue":"1","key":"9524_CR20","doi-asserted-by":"publisher","first-page":"104","DOI":"10.5811\/westjem.2022.11.58053","volume":"24","author":"AD Bloom","year":"2022","unstructured":"Bloom AD, Aliotta RE, Mihas A, Peterson DT, Robinett DA, White ML. Tele-Simulated Instruction and Learner Perceptions of Fiberoptic Intubation and Nasopharyngoscopy: A Pilot Study. West J Emerg Med. 2022;24(1):104\u20139.","journal-title":"West J Emerg Med"},{"issue":"8","key":"9524_CR21","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1111\/anae.13951","volume":"72","author":"TH Pedersen","year":"2017","unstructured":"Pedersen TH, Gysin J, Wegmann A, Osswald M, Ott SR, Theiler L, Greif R. A randomised, controlled trial evaluating a low cost, 3D-printed bronchoscopy simulator. Anaesthesia. 2017;72(8):1005\u20139.","journal-title":"Anaesthesia"},{"issue":"4","key":"9524_CR22","doi-asserted-by":"publisher","first-page":"714","DOI":"10.1177\/01945998221117507","volume":"168","author":"R Sethia","year":"2023","unstructured":"Sethia R, Alfayez Y, VanKoevering KK, Seim NB. Altered Airway Anatomy Course Using 3D-Printed Models for Medical Students. Otolaryngol Head Neck Surg. 2023;168(4):714\u20139.","journal-title":"Otolaryngol Head Neck Surg"},{"issue":"1","key":"9524_CR23","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1186\/s12909-023-05013-6","volume":"24","author":"MV Epperson","year":"2024","unstructured":"Epperson MV, Mahajan A, Sethia R, Seim N, VanKoevering K, Morrison RJ. A deployable curriculum with 3D printed skills trainers for altered airway management. BMC Med Educ. 2024;24(1):39.","journal-title":"BMC Med Educ"},{"issue":"10","key":"9524_CR24","doi-asserted-by":"publisher","first-page":"1283","DOI":"10.1111\/anae.14053","volume":"72","author":"A Hartopp","year":"2017","unstructured":"Hartopp A, Ahmed I, Miller G. 3-D printing in anaesthesia: challenges and controversies. Anaesthesia. 2017;72(10):1283\u20134.","journal-title":"Anaesthesia"}],"container-title":["BMC Medical Education"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12909-026-09524-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12909-026-09524-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12909-026-09524-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:53:00Z","timestamp":1784595180000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12909-026-09524-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,26]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["9524"],"URL":"https:\/\/doi.org\/10.1186\/s12909-026-09524-w","relation":{},"ISSN":["1472-6920"],"issn-type":[{"value":"1472-6920","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,26]]},"assertion":[{"value":"6 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study protocol (201908009RIN) was approved by the National Taiwan University Hospital Research Ethic Committee (Chairperson Prof. Fu-Chang Tsai) on 30 August, 2019. This study aims to evaluate the effectiveness of using 3D-printed difficult airway models as an adjunct in teaching FBI for anaesthesia residents in our department. Participants are required to complete pre-course and post-course questionnaires, with an estimated completion time of approximately 10 to 15\u00a0min. To mitigate potential conflicts of interest and ensure the objectivity of the research, this study is conducted on an anonymous and strictly voluntary basis. Participants reserve the right to decline or withdraw from the study at any time simply by not filling out or not returning the questionnaires. In accordance with the recommendations of the Institutional Review Board (IRB) and to maintain participant anonymity, this study has been approved by the National Taiwan University Hospital (NTUH) Research Ethics Committee, and the requirement for signed informed consent has been waived.We conducted the study in accordance with the Declaration of Helsinki.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"1179"}}