{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T19:25:47Z","timestamp":1790623547982,"version":"4.1.0"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,12,14]],"date-time":"2022-12-14T00:00:00Z","timestamp":1670976000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,12,14]],"date-time":"2022-12-14T00:00:00Z","timestamp":1670976000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Inform Decis Mak"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Clinically cardiotocography is a technique which is used to monitor and evaluate the level of fetal distress. Even though, CTG is the most widely used device to monitor determine the fetus health, existence of high false positive result from the visual interpretation has a significant contribution to unnecessary surgical delivery or delayed intervention.<\/jats:p><\/jats:sec><jats:sec><jats:title>Objective<\/jats:title><jats:p>In the current study an innovative computer aided fetal distress diagnosing model is developed by using time frequency representation of FHR signal using generalized Morse wavelet and the concept of transfer learning of pre-trained ResNet 50 deep neural network model.<\/jats:p><\/jats:sec><jats:sec><jats:title>Method<\/jats:title><jats:p>From the CTG data that is obtained from the only open access CTU-UHB data base only FHR signal is extracted and preprocessed to remove noises and spikes. After preprocessing the time frequency information of FHR signal is extracted by using generalized Morse wavelet and fed to a pre-trained ResNet 50 model which is fine tuned and configured according to the dataset.<\/jats:p><\/jats:sec><jats:sec><jats:title>Main outcome measures<\/jats:title><jats:p>Sensitivity (Se), specificity (Sp) and accuracy (Acc) of the model adopted from binary confusion matrix is used as outcome measures.<\/jats:p><\/jats:sec><jats:sec><jats:title>Result<\/jats:title><jats:p>After successfully training the model, a comprehensive experimentation of testing is conducted for FHR data for which a recording is made during early stage of labor and last stage of labor. Thus, a promising classification result which is accuracy of 98.7%, sensitivity of 97.0% and specificity 100% are achieved for FHR signal of 1st stage of labor. For FHR recorded in last stage of labor, accuracy of 96.1%, sensitivity of 94.1% and specificity 97.7% are achieved.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The developed model can be used as a decision-making aid system for obstetrician and gynecologist.<\/jats:p><\/jats:sec>","DOI":"10.1186\/s12911-022-02068-1","type":"journal-article","created":{"date-parts":[[2022,12,14]],"date-time":"2022-12-14T10:03:01Z","timestamp":1671012181000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Deep learning based fetal distress detection from time frequency representation of cardiotocogram signal using Morse wavelet: research study"],"prefix":"10.1186","volume":"22","author":[{"given":"Yared Daniel","family":"Daydulo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bheema Lingaiah","family":"Thamineni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hanumesh Kumar","family":"Dasari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Genet Tadese","family":"Aboye","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,12,14]]},"reference":[{"key":"2068_CR1","unstructured":"Pashte S. Diagnosis and management of fetal distress. Eur J Biomed Pharm Sci. 2017; (December 2016)."},{"issue":"6","key":"2068_CR2","doi-asserted-by":"publisher","first-page":"1421","DOI":"10.1016\/0002-9378(90)90901-I","volume":"162","author":"P Gt","year":"1990","unstructured":"Gt P, Eg L. What is fetal distress? Am J Obstet Gynecol. 1990;162(6):1421\u20137. https:\/\/doi.org\/10.1016\/0002-9378(90)90901-I.","journal-title":"Am J Obstet Gynecol"},{"key":"2068_CR3","doi-asserted-by":"publisher","DOI":"10.1016\/j.bpobgyn.2015.03.022","author":"A Pinas","year":"2015","unstructured":"Pinas A, Obstetrician C, Chandraharan E, Obs MS, Consultant L, Ward L. Continuous cardiotocography during labour. Best Pract Res Clin Obstet Gynaecol. 2015. https:\/\/doi.org\/10.1016\/j.bpobgyn.2015.03.022.","journal-title":"Best Pract Res Clin Obstet Gynaecol"},{"key":"2068_CR4","doi-asserted-by":"publisher","DOI":"10.1111\/aogs.13064","author":"R Carvalho","year":"2016","unstructured":"Carvalho R, et al. Agreement and accuracy using the FIGO, ACOG and NICE cardiotocography interpretation guidelines. J Gynecol. 2016. https:\/\/doi.org\/10.1111\/aogs.13064.","journal-title":"J Gynecol"},{"key":"2068_CR5","doi-asserted-by":"publisher","DOI":"10.3109\/01443615.2014.958144","author":"S Uccella","year":"2014","unstructured":"Uccella S, et al. \u201cInterobserver reliability to interpret intrapartum electronic fetal heart rate monitoring: Does a standardized algorithm improve agreement among clinicians? J Obstet Gynaecol. 2014. https:\/\/doi.org\/10.3109\/01443615.2014.958144.","journal-title":"J Obstet Gynaecol"},{"key":"2068_CR6","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.ejogrb.2016.08.017","volume":"205","author":"M Rei","year":"2016","unstructured":"Rei M, Tavares S, Pinto P, Machado AP. Interobserver agreement in CTG interpretation using the 2015 FIGO guidelines for intrapartum fetal monitoring. Eur J Obstet Gynecol Reprod Biol. 2016;205:27\u201331. https:\/\/doi.org\/10.1016\/j.ejogrb.2016.08.017.","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"issue":"2","key":"2068_CR7","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/S0889-8545(05)70073-5","volume":"26","author":"S Penning","year":"1999","unstructured":"Penning S, et al. Management of fetal distress. Obstet Gynecol Clin N Am. 1999;26(2):259\u201374.","journal-title":"Obstet Gynecol Clin N Am"},{"key":"2068_CR8","doi-asserted-by":"publisher","DOI":"10.21767\/1791-809X.1000468","author":"S Alyousif","year":"2016","unstructured":"Alyousif S, Mohd MA, Bilal B, Sheikh M, Algunaidi M. Rule-based algorithm for intrapartum cardiotocograph pattern features extraction and classification CTG data sets description. iMedPub J. 2016. https:\/\/doi.org\/10.21767\/1791-809X.1000468.","journal-title":"iMedPub J"},{"key":"2068_CR9","doi-asserted-by":"crossref","unstructured":"Sbrollini A et al. Automatic identification and classification of fetal heart\u2014rate decelerations from cardiotocographic recordings, pp. 474\u20137; 2018.","DOI":"10.1109\/EMBC.2018.8512432"},{"key":"2068_CR10","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.bspc.2018.10.002","volume":"49","author":"A Houz\u00e9","year":"2019","unstructured":"Houz\u00e9 A, et al. Automated fetal heart rate analysis for baseline determination and acceleration\/deceleration detection. Biomed Signal Process Control. 2019;49:113\u201323. https:\/\/doi.org\/10.1016\/j.bspc.2018.10.002.","journal-title":"Biomed Signal Process Control"},{"key":"2068_CR11","doi-asserted-by":"publisher","first-page":"1205","DOI":"10.1007\/978-3-319-32703-7_234","volume":"57","author":"CD Stylios","year":"2016","unstructured":"Stylios CD, Georgoulas G, Karvelis P, Spilka J, Chud\u00e1\u010dek V, Lhotska L. Least squares support vector machines for FHR classification and assessing the pH based categorization. IFMBE Proc. 2016;57:1205\u20139. https:\/\/doi.org\/10.1007\/978-3-319-32703-7_234.","journal-title":"IFMBE Proc"},{"issue":"2\u20133","key":"2068_CR12","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1007\/s12553-017-0201-7","volume":"7","author":"G Georgoulas","year":"2017","unstructured":"Georgoulas G, Karvelis P, Spilka J, Chud\u00e1\u010dek V, Stylios CD, Lhotsk\u00e1 L. Investigating pH based evaluation of fetal heart rate (FHR) recordings. Health Technol (Berl). 2017;7(2\u20133):241\u201354. https:\/\/doi.org\/10.1007\/s12553-017-0201-7.","journal-title":"Health Technol (Berl)"},{"key":"2068_CR13","doi-asserted-by":"publisher","DOI":"10.3390\/jcm7080223","author":"Z Zhao","year":"2018","unstructured":"Zhao Z, Zhang Y. A comprehensive feature analysis of the fetal heart rate signal for the intelligent assessment of fetal state. J Clin Med Artic. 2018. https:\/\/doi.org\/10.3390\/jcm7080223.","journal-title":"J Clin Med Artic"},{"key":"2068_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2018.06.003","author":"Z C\u00f6mert","year":"2018","unstructured":"C\u00f6mert Z, Kocamaz AF, Subha V. Prognostic model based on image-based time-frequency features and genetic algorithm for fetal hypoxia assessment. Comput Biol Med. 2018. https:\/\/doi.org\/10.1016\/j.compbiomed.2018.06.003.","journal-title":"Comput Biol Med"},{"issue":"4","key":"2068_CR15","first-page":"26","volume":"156","author":"Z C\u00f6mert","year":"2016","unstructured":"C\u00f6mert Z. Evaluation of Fetal Distress Diagnosis during Delivery Stages based on Linear and Nonlinear Features of Fetal Heart Rate for Neural Network Community. Int J Comput Appl. 2016;156(4):26\u201331.","journal-title":"Int J Comput Appl"},{"key":"2068_CR16","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1007\/978-3-319-64265-9","volume-title":"The use of convolutional neural networks in biomedical data processing","author":"M Bursa","year":"2017","unstructured":"Bursa M, Lhotska L. The use of convolutional neural networks in biomedical data processing. Berlin: Springer; 2017. p. 100\u201319. https:\/\/doi.org\/10.1007\/978-3-319-64265-9."},{"key":"2068_CR17","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1007\/978-3-319-91186-1_25","volume":"763","author":"Z C\u00f6mert","year":"2019","unstructured":"C\u00f6mert Z, Kocamaz AF. Fetal hypoxia detection based on deep convolutional neural network with transfer learning approach. Adv Intell Syst Comput. 2019;763:239\u201348. https:\/\/doi.org\/10.1007\/978-3-319-91186-1_25.","journal-title":"Adv Intell Syst Comput"},{"key":"2068_CR18","first-page":"1","volume":"5","author":"Z Zhao","year":"2019","unstructured":"Zhao Z, Deng Y, Zhang Y, Zhang Y, Zhang X, Shao L. DeepFHR: intelligent prediction of fetal Acidemia using fetal heart rate signals based on convolutional neural network. BMC Med Inform Decis Mak. 2019;5:1\u201315.","journal-title":"BMC Med Inform Decis Mak"},{"issue":"11","key":"2068_CR19","first-page":"2985","volume":"7","author":"K Parvathavarthine","year":"2020","unstructured":"Parvathavarthine K, Balasubramanian R. Optimized residual convolutional learning neural network for intrapartum maternal-embryo risk assessment. Eur J Mol Clin Med. 2020;7(11):2985\u20133006.","journal-title":"Eur J Mol Clin Med"},{"issue":"December","key":"2068_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fped.2021.736834","volume":"9","author":"MG Frasch","year":"2021","unstructured":"Frasch MG, Strong SB, Nilosek D, Leaverton J. Detection of preventable fetal distress during labor from scanned cardiotocogram tracings using deep learning. Front Pediatr. 2021;9(December):1\u20138. https:\/\/doi.org\/10.3389\/fped.2021.736834.","journal-title":"Front Pediatr"},{"key":"2068_CR21","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-92805-9","author":"J Ogasawara","year":"2021","unstructured":"Ogasawara J, Ikenoue S, Yamamoto H, Sato M, Kasuga Y. Deep neural network-based classification of cardiotocograms outperformed conventional algorithms. Sci Rep. 2021. https:\/\/doi.org\/10.1038\/s41598-021-92805-9.","journal-title":"Sci Rep"},{"key":"2068_CR22","first-page":"1","volume":"1573404816","author":"M Saini","year":"2021","unstructured":"Saini M, Kaur J. Fetal distress classification with deep convolutional neural network. Curr Women\u2019s Health Rev. 2021;1573404816:1\u20134.","journal-title":"Curr Women\u2019s Health Rev"},{"key":"2068_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijgo.2015.06.020","author":"SD Debrah Lewis","year":"2015","unstructured":"Debrah Lewis SD. FIGO consensus guidelines on intrapartum fetal monitoring: intermittent auscultation. CLoK Cent Lancash. 2015. https:\/\/doi.org\/10.1016\/j.ijgo.2015.06.020.","journal-title":"CLoK Cent Lancash"},{"key":"2068_CR24","doi-asserted-by":"crossref","unstructured":"Chud\u00e1\u010dek V, Bur\u0161a M, Jank P, Hruban L, Huptych M, Lhotsk\u00e1 L. Open access intrapartum CTG database. BMC Pregnancy Childbirth 2014: 1\u201312. http:\/\/www.biomedcentral.com\/1471-2393\/14\/16.","DOI":"10.1186\/1471-2393-14-16"},{"issue":"October","key":"2068_CR25","first-page":"943","volume":"287","author":"GS Sykes","year":"1983","unstructured":"Sykes GS, Molloy PM, Johnson P, Stirrat GM, Turnbull AC. Fetal distress and the condition of newborn infants. Nuff Dep Obstet Gynaecol John Radcliffe Hosp Oxford. 1983;287(October):943\u20135.","journal-title":"Nuff Dep Obstet Gynaecol John Radcliffe Hosp Oxford"},{"key":"2068_CR26","doi-asserted-by":"crossref","unstructured":"Chud\u00e1\u010dek L, Huptych V, Kouck\u00fd M, Spilka M, Bauer J, Lhotsk\u00e1 L. Fetal heart rate data pre-processing and annotation. In: International conference on information technology and biomedical engineering, pp. 1\u20134.","DOI":"10.1109\/ITAB.2009.5394441"},{"issue":"March","key":"2068_CR27","doi-asserted-by":"publisher","first-page":"103468","DOI":"10.1016\/j.compbiomed.2019.103468","volume":"114","author":"S Boudet","year":"2019","unstructured":"Boudet S, et al. Fetal heart rate baseline computation with a weighted median filter. Comput Biol Med. 2019;114(March):103468. https:\/\/doi.org\/10.1016\/j.compbiomed.2019.103468.","journal-title":"Comput Biol Med"},{"key":"2068_CR28","unstructured":"Walberg G. Cubic spline interpolation: a review; 1988."},{"key":"2068_CR29","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.bspc.2018.05.016","volume":"45","author":"Z C\u00f6mert","year":"2018","unstructured":"C\u00f6mert Z, Fatih A. Open-access software for analysis of fetal heart rate signals. Biomed Signal Process Control. 2018;45:98\u2013108. https:\/\/doi.org\/10.1016\/j.bspc.2018.05.016.","journal-title":"Biomed Signal Process Control"},{"key":"2068_CR30","unstructured":"Iwana BK, Uchida S. An empirical survey of data augmentation for time series classification with neural networks. IEEE, pp. 1\u201317."},{"key":"2068_CR31","doi-asserted-by":"publisher","DOI":"10.1101\/397182","author":"MX Cohen","year":"2018","unstructured":"Cohen MX. A better way to define and describe Morlet wavelets for time-frequency analysis. Radboud Univ Med Cent. 2018. https:\/\/doi.org\/10.1101\/397182.","journal-title":"Radboud Univ Med Cent"},{"key":"2068_CR32","doi-asserted-by":"publisher","DOI":"10.3390\/s19040935","author":"Y Byeon","year":"2019","unstructured":"Byeon Y, Pan S. Intelligent deep models based on scalograms of electrocardiogram signals for biometrics. Sensors (Switzerland). 2019. https:\/\/doi.org\/10.3390\/s19040935.","journal-title":"Sensors (Switzerland)"},{"key":"2068_CR33","doi-asserted-by":"crossref","unstructured":"Wachowiak MP et al. Quantitative feature analysis of continuous analytic wavelet transforms of electrocardiography and electromyography. R Soc. 2018; (ii).","DOI":"10.1098\/rsta.2017.0250"},{"key":"2068_CR34","unstructured":"Gannaz I et al. Analytic wavelets for multivariate time series analysis. HAL, pp. 1\u20138; 2019."},{"issue":"February 2008","key":"2068_CR35","first-page":"1","volume":"57","author":"JM Lilly","year":"2009","unstructured":"Lilly JM, Olhede SC. Higher-order properties of analytic wavelets. IEEE Trans Signal Process. 2009;57(February 2008):1\u201316.","journal-title":"IEEE Trans Signal Process"},{"key":"2068_CR36","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIT.2010.2050935","volume":"56","author":"JM Lilly","year":"2010","unstructured":"Lilly JM, Olhede SC. On the analytic wavelet transform. IEEE Trans Inf Theory. 2010;56:1\u201322.","journal-title":"IEEE Trans Inf Theory"},{"key":"2068_CR37","unstructured":"Lilly JM, Olhede SC. Generalized Morse wavelets as a superfamily of analytic wavelets. IEEE Trans Signal Process. 2012: 1\u20137. http:\/\/www.ieee.org\/publications_standards%0A\/publications\/rights\/rights_policies.html. Accessed 03 Mar 2021."},{"key":"2068_CR38","doi-asserted-by":"publisher","DOI":"10.1098\/rspa.2016.0776","author":"JM Lilly","year":"2017","unstructured":"Lilly JM. A wavelet-based method for analysing time-localized events in noisy time series. R Soc. 2017. https:\/\/doi.org\/10.1098\/rspa.2016.0776.","journal-title":"R Soc"},{"key":"2068_CR39","unstructured":"Transfer learning from pre-trained models|by Pedro Marcelino|towards data science. https:\/\/towardsdatascience.com\/transfer-learning-from-pre-trained-models-f2393f124751. Accessed 07 Dec 2021."},{"key":"2068_CR40","doi-asserted-by":"publisher","unstructured":"Alippi C, Milano P, Disabato S, Milano P, Roveri M, Milano P. Moving convolutional neural networks to embedded systems: the AlexNet and VGG-16 case, pp. 212\u201323; 2018. https:\/\/doi.org\/10.1109\/IPSN.2018.00049.","DOI":"10.1109\/IPSN.2018.00049"},{"key":"2068_CR41","doi-asserted-by":"crossref","unstructured":"He K, Sun J. Deep residual learning for image recognition. In: 2016 IEEE conference on computer vision and pattern recognition, pp. 1\u20139.","DOI":"10.1109\/CVPR.2016.90"},{"key":"2068_CR42","unstructured":"Sachan A. Detailed guide to understand and implement ResNets. https:\/\/cv-tricks.com\/keras\/understand-implement-resnets\/. Accessed 20 Dec 2021."}],"container-title":["BMC Medical Informatics and Decision Making"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12911-022-02068-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12911-022-02068-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12911-022-02068-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,10]],"date-time":"2024-10-10T10:05:44Z","timestamp":1728554744000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedinformdecismak.biomedcentral.com\/articles\/10.1186\/s12911-022-02068-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,14]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["2068"],"URL":"https:\/\/doi.org\/10.1186\/s12911-022-02068-1","relation":{},"ISSN":["1472-6947"],"issn-type":[{"value":"1472-6947","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,14]]},"assertion":[{"value":"24 May 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 November 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 December 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The corresponding author declares that there is no conflict of interest on the part of any of the other authors, including themselves.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"329"}}