{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T00:54:07Z","timestamp":1790902447837,"version":"4.1.0"},"reference-count":58,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T00:00:00Z","timestamp":1783555200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T00:00:00Z","timestamp":1790899200000},"content-version":"vor","delay-in-days":85,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Inform Decis Mak"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Implant-supported prostheses are widely used in posterior mandibular restorations, where biomechanical factors play a critical role in long-term performance. Abutment design may influence stress distribution within implant-supported systems, potentially affecting both prosthetic components and surrounding bone. This study aimed to evaluate stress distribution in three-unit implant-supported prostheses with different abutment designs using three-dimensional finite element analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A three-dimensional finite element model of the posterior mandible with two implants (4.1\u00a0mm diameter, 10\u00a0mm length) placed in the first premolar and first molar regions was constructed. Three abutment designs (multi-unit, octa, and variobase) supporting monolithic zirconia restorations were analyzed. Vertical (150\u00a0N) forces were applied perpendicular to the occlusal surfaces, and oblique (200\u00a0N at 45\u00b0) forces were applied in the buccolingual direction. Stress distribution in implants, abutments, screws, restorations, and surrounding bone was evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Stress distribution varied according to abutment design and loading condition. Variobase abutments showed higher stress concentrations in implants under both loading conditions, while octa abutments exhibited higher stress values in screws and restorations. Multi-unit abutments demonstrated relatively lower stress values in screws and restorations compared to other designs. Oblique loading produced higher stress levels than vertical loading across all components. Bone stress values increased under oblique loading conditions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Within the limitations of this finite element analysis, abutment design influenced stress distribution in implant-supported prostheses, and loading direction affected stress magnitude. These findings provide biomechanical insight into the behavior of different abutment designs in posterior implant-supported restorations.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12911-026-03690-z","type":"journal-article","created":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T02:25:05Z","timestamp":1783563905000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Stress distribution in three-unit implant-supported prostheses with different abutment designs: a finite element analysis"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9835-9289","authenticated-orcid":false,"given":"Ismail Furkan","family":"Guney","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3145-4454","authenticated-orcid":false,"given":"Busra","family":"Tosun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,9]]},"reference":[{"issue":"3","key":"3690_CR1","first-page":"164","volume":"6","author":"SA Nazar","year":"2023","unstructured":"Nazar SA, Nair VV, Harshakumar K, Ravichandran R. Full mouth rehabilitation in a worn out dentition with collapsed bite using implants: a clinical report. J Prosthet Implant Dent. 2023;6(3):164\u20137.","journal-title":"J Prosthet Implant Dent"},{"issue":"10","key":"3690_CR2","doi-asserted-by":"publisher","first-page":"346","DOI":"10.5742\/MEWFM.2018.93283","volume":"7","author":"M Frazadmoghadam","year":"2018","unstructured":"Frazadmoghadam M, Mohammadi TM, Mohammadi M, Goudarzi R. Oral health related quality of life in patients undertaking implant treatments: a review of literature. Middle East J Fam Med. 2018;7(10):346.","journal-title":"Middle East J Fam Med"},{"issue":"4","key":"3690_CR3","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1111\/j.1365-2842.2010.02170.x","volume":"38","author":"A Wennerberg","year":"2011","unstructured":"Wennerberg A, Albrektsson T. Current challenges in successful rehabilitation with oral implants. J Oral Rehabil. 2011;38(4):286\u201394.","journal-title":"J Oral Rehabil"},{"issue":"3","key":"3690_CR4","doi-asserted-by":"publisher","first-page":"267","DOI":"10.4103\/1305-7456.115407","volume":"7","author":"PCP Feitosa","year":"2013","unstructured":"Feitosa PCP, de Lima APB, Brandt WC, Neves ACC. Stability of external and internal implant connections after a fatigue test. Eur J Dent. 2013;7(3):267\u201371.","journal-title":"Eur J Dent"},{"key":"3690_CR5","first-page":"120","volume":"1","author":"A Paul","year":"2024","unstructured":"Paul A, Bhargava A, Gupta RK, Malhotra P, Singh M, Dua B. Stress transmission on bone and prosthetic screws influenced by implant position: a finite element analysis. Framework. 2024;1:120.","journal-title":"Framework"},{"issue":"3","key":"3690_CR6","doi-asserted-by":"publisher","first-page":"131","DOI":"10.18231\/j.aprd.2021.028","volume":"7","author":"P Prakash","year":"2021","unstructured":"Prakash P, Narayanan A. Biomechanics in dental implants. IP Ann Prosthodont Restor Dent. 2021;7(3):131\u20136.","journal-title":"IP Ann Prosthodont Restor Dent"},{"issue":"5","key":"3690_CR7","doi-asserted-by":"publisher","first-page":"321","DOI":"10.3109\/00016357.2014.961957","volume":"73","author":"E Borie","year":"2015","unstructured":"Borie E, Orsi IA, de Araujo CP. The influence of the connection, length and diameter of an implant on bone biomechanics. Acta Odontol Scand. 2015;73(5):321\u20139.","journal-title":"Acta Odontol Scand"},{"issue":"1","key":"3690_CR8","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1097\/ID.0b013e3181bb9033","volume":"19","author":"A Lee","year":"2010","unstructured":"Lee A, Okayasu K, Wang H-L. Screw-versus cement-retained implant restorations: current concepts. Implant Dent. 2010;19(1):8\u201315.","journal-title":"Implant Dent"},{"issue":"1","key":"3690_CR9","first-page":"13","volume":"3","author":"F Aykent","year":"2017","unstructured":"Aykent F, \u00d6zdo\u011fan MS, So\u011fanci G. \u0130mplant \u00fcst\u00fc protezlerde okl\u00fczyon. Turkiye Klinikleri Prosthodontics-Special Top. 2017;3(1):13\u201321.","journal-title":"Turkiye Klinikleri Prosthodontics-Special Top"},{"issue":"5","key":"3690_CR10","first-page":"1102","volume":"26","author":"J Nissan","year":"2011","unstructured":"Nissan J, Narobai D, Gross O, Ghelfan O, Chaushu G. Long-term outcome of cemented versus screw-retained implant-supported partial restorations. Int J Oral Maxillofac Implants. 2011;26(5):1102\u20138.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"3","key":"3690_CR11","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1111\/jcpe.12041","volume":"40","author":"ML De Brand\u00e3o","year":"2013","unstructured":"De Brand\u00e3o ML, Vettore MV, Vidigal J\u00fanior GM. Peri-implant bone loss in cement- and screw-retained prostheses: systematic review and meta-analysis. J Clin Periodontol. 2013;40(3):287\u201395.","journal-title":"J Clin Periodontol"},{"issue":"4","key":"3690_CR12","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1016\/j.prosdent.2015.08.026","volume":"115","author":"CAA Lemos","year":"2016","unstructured":"Lemos CAA, de Souza Batista VE, de Faria Almeida DA, J\u00fanior JFS, Verri FR, Pellizzer EP. Evaluation of cement-retained versus screw-retained implant-supported restorations for marginal bone loss: a systematic review and meta-analysis. J Prosthet Dent. 2016;115(4):419\u201327.","journal-title":"J Prosthet Dent"},{"key":"3690_CR13","doi-asserted-by":"publisher","first-page":"3087071","DOI":"10.1155\/2021\/3087071","volume":"2021","author":"E P\u00e9rez-Pevida","year":"2021","unstructured":"P\u00e9rez-Pevida E, Ch\u00e1varri-Prado D, Di\u00e9guez-Pereira M, Estrada-Mart\u00ednez A, Montalb\u00e1n-Vadillo O, Jim\u00e9nez-Garrudo A. Consequences of peri-implant bone loss in occlusal load transfer to the supporting bone in terms of magnitude of stress, strain, and stress distribution: a finite element analysis. Biomed Res Int. 2021;2021:3087071.","journal-title":"Biomed Res Int"},{"issue":"1593","key":"3690_CR14","first-page":"1603","volume":"62","author":"EM Agamy","year":"2016","unstructured":"Agamy EM. Stress analysis studies with dental implants in different situations and connections with natural teeth. Dent J. 2016;62(1593):1603.","journal-title":"Dent J"},{"issue":"3","key":"3690_CR15","doi-asserted-by":"publisher","first-page":"425","DOI":"10.4103\/0970-9290.70813","volume":"21","author":"A Srirekha","year":"2010","unstructured":"Srirekha A, Bashetty K. Infinite to finite: an overview of finite element analysis. Indian J Dent Res. 2010;21(3):425\u201332.","journal-title":"Indian J Dent Res"},{"issue":"5","key":"3690_CR16","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1080\/10255842.2020.1836168","volume":"24","author":"P Ausiello","year":"2021","unstructured":"Ausiello P, Ciaramella S, De Benedictis A, Lanzotti A, Tribst J, Watts D. The use of different adhesive filling material and mass combinations to restore class II cavities under loading and shrinkage effects: a 3D finite element analysis. Comput Methods Biomech Biomed Engin. 2021;24(5):485\u201395.","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"5","key":"3690_CR17","doi-asserted-by":"publisher","first-page":"e0285421","DOI":"10.1371\/journal.pone.0285421","volume":"18","author":"E Epifania","year":"2023","unstructured":"Epifania E, di Lauro AE, Ausiello P, Mancone A, Garcia-Godoy F, Mendes Tribst JP. Effect of crown stiffness and prosthetic screw absence on stress distribution in implant-supported restorations: a 3D finite element analysis. PLoS ONE. 2023;18(5):e0285421.","journal-title":"PLoS ONE"},{"issue":"14","key":"3690_CR18","doi-asserted-by":"publisher","first-page":"8147","DOI":"10.3390\/app13148147","volume":"13","author":"N Di Pietro","year":"2023","unstructured":"Di Pietro N, Ceddia M, Romasco T, De Bortoli Junior N, Mello BF, Tumedei M, et al. Finite element analysis (FEA) of stress and strain distribution in cone-morse implant\u2013abutment connection implants placed equicrestally and subcrestally. Appl Sci (Basel). 2023;13(14):8147.","journal-title":"Appl Sci (Basel)"},{"issue":"3","key":"3690_CR19","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1016\/j.dental.2007.05.007","volume":"24","author":"I Denry","year":"2008","unstructured":"Denry I, Kelly JR. State of the art of zirconia for dental applications. Dent Mater. 2008;24(3):299\u2013307.","journal-title":"Dent Mater"},{"issue":"1","key":"3690_CR20","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.prosdent.2015.06.021","volume":"115","author":"T-H Lan","year":"2016","unstructured":"Lan T-H, Liu P-H, Chou MM, Lee H-E. Fracture resistance of monolithic zirconia crowns with different occlusal thicknesses in implant prostheses. J Prosthet Dent. 2016;115(1):76\u201383.","journal-title":"J Prosthet Dent"},{"key":"3690_CR21","volume-title":"Dental anatomy, physiology, and occlusion","author":"RC Wheeler","year":"1974","unstructured":"Wheeler RC. Dental anatomy, physiology, and occlusion. Philadelphia: Saunders; 1974."},{"issue":"Suppl 1","key":"3690_CR22","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1111\/j.1834-7819.2010.01299.x","volume":"56","author":"JR Kelly","year":"2011","unstructured":"Kelly JR, Benetti P. Ceramic materials in dentistry: historical evolution and current practice. Aust Dent J. 2011;56(Suppl 1):84\u201396.","journal-title":"Aust Dent J"},{"issue":"1","key":"3690_CR23","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.dental.2018.08.291","volume":"35","author":"Y Zhang","year":"2019","unstructured":"Zhang Y, Lawn BR. Evaluating dental zirconia. Dent Mater. 2019;35(1):15\u201323.","journal-title":"Dent Mater"},{"key":"3690_CR24","doi-asserted-by":"publisher","first-page":"108708","DOI":"10.1016\/j.compbiomed.2024.108708","volume":"178","author":"K Karakaya","year":"2024","unstructured":"Karakaya K, \u00dcnal SM. Evaluation of stress distribution of different marginal designs on PEEK and PEKK substructure materials, cortical and cancellous bone: a finite element analysis. Comput Biol Med. 2024;178:108708.","journal-title":"Comput Biol Med"},{"key":"3690_CR25","volume-title":"Shigley\u2019s mechanical engineering design","author":"RG Budynas","year":"2011","unstructured":"Budynas RG, Nisbett JK. Shigley\u2019s mechanical engineering design. New York: McGraw-Hill; 2011."},{"issue":"1","key":"3690_CR26","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1016\/j.dental.2022.12.001","volume":"39","author":"P Ausiello","year":"2023","unstructured":"Ausiello P, Di Lauro AE, Tribst JPM, Watts DC. Stress distribution in resin-based CAD-CAM implant-supported crowns. Dent Mater. 2023;39(1):114\u201322.","journal-title":"Dent Mater"},{"issue":"3","key":"3690_CR27","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1016\/j.prosdent.2015.03.003","volume":"114","author":"B Yilmaz","year":"2015","unstructured":"Yilmaz B, L\u2019Homme-Langlois E, Beck FM, McGlumphy E. Accuracy of mechanical torque-limiting devices for dental implants after clinical service. J Prosthet Dent. 2015;114(3):378\u201382.","journal-title":"J Prosthet Dent"},{"issue":"4","key":"3690_CR28","doi-asserted-by":"publisher","first-page":"590","DOI":"10.4103\/ccd.ccd_739_18","volume":"10","author":"V Kharsan","year":"2019","unstructured":"Kharsan V, Bandgar V, Mirza A, Jagtiani K, Dhariwal N, Kore R. Comparative evaluation of three abutment\u2013implant interfaces on stress distribution in and around different implant systems: a finite element analysis. Contemp Clin Dent. 2019;10(4):590\u20134.","journal-title":"Contemp Clin Dent"},{"issue":"4","key":"3690_CR29","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1016\/j.prosdent.2020.08.042","volume":"128","author":"H Lee","year":"2022","unstructured":"Lee H, Jo M, Sailer I, Noh G. Effects of implant diameter, implant\u2013abutment connection type, and bone density on the biomechanical stability of implant components and bone: a finite element analysis study. J Prosthet Dent. 2022;128(4):716\u201328.","journal-title":"J Prosthet Dent"},{"issue":"6","key":"3690_CR30","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1067\/mpr.2001.115251","volume":"85","author":"J-P Geng","year":"2001","unstructured":"Geng J-P, Tan KB, Liu G-R. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent. 2001;85(6):585\u201398.","journal-title":"J Prosthet Dent"},{"issue":"7","key":"3690_CR31","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1111\/jopr.13282","volume":"30","author":"R Savignano","year":"2021","unstructured":"Savignano R, Soltanzadeh P, Suprono MS. Computational biomechanical analysis of engaging and nonengaging abutments for implant screw-retained fixed dental prostheses. J Prosthodont. 2021;30(7):604\u20139.","journal-title":"J Prosthodont"},{"issue":"6","key":"3690_CR32","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1111\/j.1600-0501.2006.01307.x","volume":"18","author":"RJ Blanes","year":"2007","unstructured":"Blanes RJ, Bernard JP, Blanes ZM, Belser UC. A 10-year prospective study of ITI dental implants placed in the posterior region. II: influence of the crown-to-implant ratio and different prosthetic treatment modalities on crestal bone loss. Clin Oral Implants Res. 2007;18(6):707\u201314.","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"3690_CR33","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1111\/j.1600-0501.2009.01867.x","volume":"21","author":"L Canullo","year":"2010","unstructured":"Canullo L, Fedele GR, Iannello G, Jepsen S. Platform switching and marginal bone-level alterations: the results of a randomized controlled trial. Clin Oral Implants Res. 2010;21(1):115\u201321.","journal-title":"Clin Oral Implants Res"},{"issue":"5","key":"3690_CR34","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1111\/jopr.13065","volume":"28","author":"T Tang","year":"2019","unstructured":"Tang T, Huang Z, Liao L, Gu X, Zhang J, Zhang X. Factors that influence direction deviation in freehand implant placement. J Prosthodont. 2019;28(5):511\u20138.","journal-title":"J Prosthodont"},{"issue":"2","key":"3690_CR35","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/S0022-3913(03)00212-9","volume":"90","author":"CJ Goodacre","year":"2003","unstructured":"Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications with implants and implant prostheses. J Prosthet Dent. 2003;90(2):121\u201332.","journal-title":"J Prosthet Dent"},{"issue":"1","key":"3690_CR36","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1002\/cre2.97","volume":"4","author":"A Epprecht","year":"2018","unstructured":"Epprecht A, Zeltner M, Benic G, \u00d6zcan M. A strain gauge analysis comparing 4-unit veneered zirconium dioxide implant-borne fixed dental prostheses on engaging and non-engaging abutments before and after torque application. Clin Exp Dent Res. 2018;4(1):13\u20138.","journal-title":"Clin Exp Dent Res"},{"issue":"1","key":"3690_CR37","first-page":"11","volume":"5","author":"G Sannino","year":"2012","unstructured":"Sannino G, Pozzi A, Schiavetti R, Barlattani A. Stress distribution on a three-unit implant-supported zirconia framework: a 3D finite element analysis and fatigue test. Oral Implantol (Rome). 2012;5(1):11\u20138.","journal-title":"Oral Implantol (Rome)"},{"issue":"2","key":"3690_CR38","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1038\/ijos.2012.35","volume":"4","author":"C-B Tang","year":"2012","unstructured":"Tang C-B, Liu S-Y, Zhou G-X, Yu J-H, Zhang G-D, Bao Y-D, Wang Q-J. Nonlinear finite element analysis of three implant\u2013abutment interface designs. Int J Oral Sci. 2012;4(2):101\u201308.","journal-title":"Int J Oral Sci"},{"key":"3690_CR39","volume-title":"Management of temporomandibular disorders and occlusion","author":"JP Okeson","year":"2003","unstructured":"Okeson JP. Management of temporomandibular disorders and occlusion. 5th ed. St. Louis: Mosby; 2003.","edition":"5"},{"key":"3690_CR40","first-page":"141","volume":"10","author":"D Flanagan","year":"2017","unstructured":"Flanagan D. Bite force and dental implant treatment: a short review. Med Devices (Auckl). 2017;10:141\u20138.","journal-title":"Med Devices (Auckl)"},{"issue":"2","key":"3690_CR41","doi-asserted-by":"publisher","first-page":"90","DOI":"10.15171\/joddd.2019.014","volume":"13","author":"MR Anaraki","year":"2019","unstructured":"Anaraki MR, Torab A, Mounesi Rad T. Comparison of stress in implant-supported monolithic zirconia fixed partial dentures between canine guidance and group function occlusal patterns: a finite element analysis. J Dent Res Dent Clin Dent Prospects. 2019;13(2):90\u20137.","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"issue":"19","key":"3690_CR42","doi-asserted-by":"publisher","first-page":"3056","DOI":"10.3390\/ma12193056","volume":"12","author":"H Heller","year":"2019","unstructured":"Heller H, Arieli A, Beitlitum I, Pilo R, Levartovsky S. Load-bearing capacity of zirconia crowns screwed to multi-unit abutments with and without a titanium base: an in vitro pilot study. Mater (Basel). 2019;12(19):3056.","journal-title":"Mater (Basel)"},{"issue":"2","key":"3690_CR43","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1097\/01.id.0000165030.59555.2c","volume":"14","author":"G Juodzbalys","year":"2005","unstructured":"Juodzbalys G, Kubilius R, Eidukynas V, Raustia AM. Stress distribution in bone: single-unit implant prostheses veneered with porcelain or a new composite material. Implant Dent. 2005;14(2):166\u201375.","journal-title":"Implant Dent"},{"issue":"6","key":"3690_CR44","doi-asserted-by":"publisher","first-page":"329","DOI":"10.4047\/jap.2020.12.6.329","volume":"12","author":"T Barbin","year":"2020","unstructured":"Barbin T, Silva LDR, Vel\u00f4so DV, Borges GA, Presotto AGC, Bar\u00e3o VAR, et al. Biomechanical behavior of CAD\/CAM cobalt-chromium and zirconia full-arch fixed prostheses. J Adv Prosthodont. 2020;12(6):329\u201337.","journal-title":"J Adv Prosthodont"},{"key":"3690_CR45","doi-asserted-by":"publisher","first-page":"105736","DOI":"10.1016\/j.jmbbm.2023.105736","volume":"140","author":"G Marini","year":"2023","unstructured":"Marini G, da Rosa LS, Machado PS, Silvestre FA, Valandro LF, Feitosa VP, et al. Fatigue performance analysis of strength-graded zirconia polycrystals for monolithic three-unit implant-supported prostheses. J Mech Behav Biomed Mater. 2023;140:105736.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"1","key":"3690_CR46","first-page":"43","volume":"26","author":"N Kaleli","year":"2020","unstructured":"Kaleli N, Ural \u00c7. Hibrid abutment kron restorasyonlarda implant-abutment ba\u011flant\u0131s\u0131n\u0131n implant, abutment ve bazal vidadaki stres da\u011f\u0131l\u0131m\u0131 \u00fczerindeki etkisinin incelenmesi. Turkiye Klinikleri Dishekimligi Bilimleri Dergisi. 2020;26(1):43\u201350.","journal-title":"Turkiye Klinikleri Dishekimligi Bilimleri Dergisi"},{"key":"3690_CR47","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1590\/0103-6440201300321","volume":"26","author":"RS Nishioka","year":"2015","unstructured":"Nishioka RS, Vasconcellos LGOd, J\u00f3ias RP, Rode SM. Load-application devices: a comparative strain gauge analysis. Braz Dent J. 2015;26:258\u201362.","journal-title":"Braz Dent J"},{"issue":"7","key":"3690_CR48","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1080\/10255842.2019.1588254","volume":"22","author":"MB Toniollo","year":"2019","unstructured":"Toniollo MB, Vieira LJP, dos Santos S\u00e1 M, Macedo AP, Melo ASSD Jr. Stress distribution of three-unit fixed partial prostheses (conventional and pontic) supported by three or two implants: 3D finite element analysis of ductile materials. Comput Methods Biomech Biomed Engin. 2019;22(7):706\u201312.","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"3690_CR49","unstructured":"Chun HJ, Shin HS, Han CH, Lee SH. Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis. Int J Oral Maxillofac Implants. 2006;21(2)."},{"issue":"6","key":"3690_CR50","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1111\/j.1600-0501.2004.01117.x","volume":"15","author":"BE Pjetursson","year":"2004","unstructured":"Pjetursson BE, Tan K, Lang NP, Br\u00e4gger U, Egger M, Zwahlen M. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years: I. Implant-supported FPDs. Clin Oral Implants Res. 2004;15(6):625\u201342.","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"3690_CR51","first-page":"15","volume":"15","author":"JB Brunski","year":"2000","unstructured":"Brunski JB, Puleo DA, Nanci A. Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments. Int J Oral Maxillofac Implants. 2000;15(1):15\u201346.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"5","key":"3690_CR52","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1111\/j.1532-849X.2011.00714.x","volume":"20","author":"SM Dogus","year":"2011","unstructured":"Dogus SM, Kurtz KS, Watanabe I, Griggs JA. Effect of engaging abutment position in implant-borne, screw\u2010retained three\u2010unit fixed cantilevered prostheses. J Prosthodont. 2011;20(5):348\u201354.","journal-title":"J Prosthodont"},{"issue":"6","key":"3690_CR53","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1016\/S0022-3913(08)60259-0","volume":"100","author":"L Baggi","year":"2008","unstructured":"Baggi L, Cappelloni I, Di Girolamo M, Maceri F, Vairo G. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis. J Prosthet Dent. 2008;100(6):422\u201331.","journal-title":"J Prosthet Dent"},{"issue":"7\u20138","key":"3690_CR54","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1016\/S0300-5712(02)00065-9","volume":"30","author":"S \u015eahin","year":"2002","unstructured":"\u015eahin S, Cehreli MC, Yal\u00e7\u0131n E. The influence of functional forces on the biomechanics of implant-supported prostheses: a review. J Dent. 2002;30(7\u20138):271\u201382.","journal-title":"J Dent"},{"issue":"5","key":"3690_CR55","first-page":"722","volume":"16","author":"K Ak\u00e7a","year":"2001","unstructured":"Ak\u00e7a K, \u0130plik\u00e7io\u011flu H. Finite element stress analysis of the influence of staggered versus straight placement of dental implants. Int J Oral Maxillofac Implants. 2001;16(5):722\u201330.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"3","key":"3690_CR56","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1016\/j.pmatsci.2008.06.004","volume":"54","author":"M Geetha","year":"2009","unstructured":"Geetha M, Singh AK, Asokamani R, Gogia AK. Ti-based biomaterials, the ultimate choice for orthopaedic implants: a review. Prog Mater Sci. 2009;54(3):397\u2013425.","journal-title":"Prog Mater Sci"},{"issue":"2","key":"3690_CR57","first-page":"93","volume":"15","author":"\u00d6 \u0130nan","year":"2009","unstructured":"\u0130nan \u00d6, Sevimay M, Eraslan O, Eskita\u015fcio\u011flu G. Comparison of finite element and photoelastic stress analysis methods. Turkiye Klinikleri J Dent Sci. 2009;15(2):93\u2013101.","journal-title":"Turkiye Klinikleri J Dent Sci"},{"issue":"1","key":"3690_CR58","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/S0300-5712(01)00057-4","volume":"30","author":"H \u0130plik\u00e7io\u011flu","year":"2002","unstructured":"\u0130plik\u00e7io\u011flu H, Ak\u00e7a K. Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone. J Dent. 2002;30(1):41\u20136.","journal-title":"J Dent"}],"container-title":["BMC Medical Informatics and Decision Making"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12911-026-03690-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12911-026-03690-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12911-026-03690-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T00:04:21Z","timestamp":1790899461000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12911-026-03690-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,9]]},"references-count":58,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3690"],"URL":"https:\/\/doi.org\/10.1186\/s12911-026-03690-z","relation":{},"ISSN":["1472-6947"],"issn-type":[{"value":"1472-6947","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,9]]},"assertion":[{"value":"8 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"382"}}