{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T07:50:33Z","timestamp":1787903433688,"version":"build-2784847793"},"reference-count":63,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,10,7]],"date-time":"2020-10-07T00:00:00Z","timestamp":1602028800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,10,7]],"date-time":"2020-10-07T00:00:00Z","timestamp":1602028800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100008414","name":"University of Canterbury","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008414","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Health Serv Res"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Reusable medical devices in healthcare facilities are decontaminated and reprocessed following standard practices before each clinical procedure. Reprocessing of critical medical devices (those used for invasive clinical procedures) comprises several processes including sterilization, which provides the highest level of decontamination. Steam sterilization is the most used sterilization procedure across the globe. Noncompliance with standards addressing reprocessing of medical devices may lead to inadequate sterilization and thus increase the risk of person-to-person or environmental transmission of pathogens in healthcare facilities. We conducted nationwide multicenter clustered audits to understand the compliance of primary- and secondary-care public hospitals in Nepal with the standard practices for medical device reprocessing, including steam sterilization.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>We developed an audit tool to assess compliance of hospitals with the standard practices for medical device reprocessing including steam sterilization. Altogether, 189 medical device reprocessing cycles which included steam sterilization were assessed in 13 primary and secondary care public hospitals in Nepal using the audit tool. Percentage compliance was calculated for each standard practice. Mean percentage compliances were obtained for overall primary and secondary care hospitals and for each hospital type, specific hospital and process involved.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>For all primary and secondary care hospitals in Nepal, the mean percentage compliance with the standard practices for medical device reprocessing including steam sterilization was 25.9% (95% CI 21.0\u201330.8%). The lower the level of care provided by the hospitals, the lower was the mean percentage compliance, and the difference in the means across the hospital types was statistically significant (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.01). The mean percentage compliance of individual hospitals ranged from 14.7 to 46.0%. The hospitals had better compliance with the practices for cleaning of used devices and transport and storage of sterilized devices compared with the practices for other processes of the medical device reprocessing cycle.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The primary and secondary care hospitals in Nepal had poor compliance with the standard practices for steam sterilization and reprocessing of medical devices. Interventions to improve compliance of the hospitals are immediately required to minimize the risks of person-to-person or environmental transmission of pathogens through inadequately reprocessed medical devices.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12913-020-05788-0","type":"journal-article","created":{"date-parts":[[2020,10,7]],"date-time":"2020-10-07T18:03:01Z","timestamp":1602093781000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Compliance of primary and secondary care public hospitals with standard practices for reprocessing and steam sterilization of reusable medical devices in Nepal: findings from nation-wide multicenter clustered audits"],"prefix":"10.1186","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5316-623X","authenticated-orcid":false,"given":"Gopal","family":"Panta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ann K.","family":"Richardson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ian C.","family":"Shaw","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patricia A.","family":"Coope","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,10,7]]},"reference":[{"key":"5788_CR1","first-page":"517","volume-title":"Disinfection, Sterilization and Preservation","author":"EH Spaulding","year":"1968","unstructured":"Spaulding EH. Chemical disinfection of medical and surgical materials. In: Disinfection, Sterilization and Preservation; 1968. p. 517\u201331."},{"key":"5788_CR2","volume-title":"Principles and methods of sterilization","author":"JJ Perkins","year":"1956","unstructured":"Perkins JJ. Principles and methods of sterilization. Springfield: Thomas; 1956."},{"key":"5788_CR3","doi-asserted-by":"publisher","first-page":"S43","DOI":"10.1016\/S0195-6701(99)90065-8","volume":"43","author":"WA Rutala","year":"1999","unstructured":"Rutala WA, Weber DJ. Infection control: the role of disinfection and sterilization. J Hosp Infect. 1999;43:S43\u201355.","journal-title":"J Hosp Infect."},{"key":"5788_CR4","unstructured":"World Health Organization (WHO). Decontamination and reprocessing of medical devices for healthcare facilities. 2016. http:\/\/apps.who.int\/iris\/bitstream\/10665\/250232\/1\/9789241549851-eng.pdf. Accessed 17 Dec 2017."},{"key":"5788_CR5","doi-asserted-by":"publisher","first-page":"48","DOI":"10.14219\/jada.archive.1993.0022","volume":"124","author":"CH Miller","year":"1993","unstructured":"Miller CH. Cleaning, sterilization and disinfection: basics of microbial killing for infection control. J Am Dent Assoc. 1993;124:48\u201356.","journal-title":"J Am Dent Assoc"},{"key":"5788_CR6","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1002\/9780470988329.ch20","volume-title":"Hugo and Russell's pharmaceutical microbiology","author":"S Denyer","year":"2004","unstructured":"Denyer S, Hodges N. Sterilization procedures and sterility assurance. In: Denyer SP, Hodges NA, Gorman SP, editors. Hugo and Russell's pharmaceutical microbiology. 7th ed. Malden: Blackwell Science; 2004. p. 346\u201375.","edition":"7"},{"issue":"6","key":"5788_CR7","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1046\/j.1365-2672.1999.00948.x","volume":"87","author":"DG Allison","year":"1999","unstructured":"Allison DG. A review: taking the sterile out of sterility. J Appl Microbiol. 1999;87(6):789\u201393.","journal-title":"J Appl Microbiol"},{"key":"5788_CR8","unstructured":"WHO. Report on the burden of endemic health care-associated infection worldwide. 2011. http:\/\/apps.who.int\/iris\/bitstream\/10665\/80135\/1\/9789241501507_eng.pdf. Accessed 7 Jul 2016."},{"issue":"3","key":"5788_CR9","first-page":"148","volume":"58","author":"BR Giri","year":"2008","unstructured":"Giri BR, Pant HP, Shankar PR, Sreeramareddy CT, Sen PK. Surgical site infection and antibiotics use pattern in a tertiary care hospital in Nepal. J Pak Med Assoc. 2008;58(3):148\u201351.","journal-title":"J Pak Med Assoc"},{"issue":"3","key":"5788_CR10","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1089\/sur.2012.108","volume":"14","author":"S Giri","year":"2013","unstructured":"Giri S, Kandel BP, Pant S, Lakhey PJ, Singh YP, Vaidya P. Risk factors for surgical site infections in abdominal surgery: a study in Nepal. Surg Infect. 2013;14(3):313\u20138.","journal-title":"Surg Infect"},{"issue":"54","key":"5788_CR11","first-page":"107","volume":"14","author":"S Shrestha","year":"2016","unstructured":"Shrestha S, Wenju P, Shrestha R, Karmacharya RM. Incidence and risk factors of surgical site infections in Kathmandu university hospital, Kavre. Nepal Kathmandu University Medical Journal. 2016;14(54):107\u201311.","journal-title":"Nepal Kathmandu University Medical Journal"},{"issue":"3","key":"5788_CR12","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1053\/jhin.2002.1187","volume":"50","author":"D Esel","year":"2002","unstructured":"Esel D, Doganay M, Bozdemir N, Yildiz O, Tezcaner T, Sumerkan B, Aygen B, Selcuklu A. Polymicrobial ventriculitis and evaluation of an outbreak in a surgical intensive care unit due to inadequate sterilization. J Hosp Infect. 2002;50(3):170\u20134.","journal-title":"J Hosp Infect"},{"issue":"4","key":"5788_CR13","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/j.jhin.2012.04.023","volume":"81","author":"SJ Dancer","year":"2012","unstructured":"Dancer SJ, Stewart M, Coulombe C, Gregori A, Virdi M. Surgical site infections linked to contaminated surgical instruments. J Hosp Infect. 2012;81(4):231\u20138.","journal-title":"J Hosp Infect."},{"issue":"12","key":"5788_CR14","doi-asserted-by":"publisher","first-page":"1179","DOI":"10.1086\/662712","volume":"32","author":"PK Tosh","year":"2011","unstructured":"Tosh PK, Disbot M, Duffy JM, Boom ML, Heseltine G, Srinivasan A, Gould CV. Berr\u0131\u2019os-Torres SI. Outbreak of Pseudomonas aeruginosa surgical site infections after arthroscopic procedures: Texas, 2009. Infect Control Hosp Epidemiol. 2011;32(12):1179\u201386.","journal-title":"Infect Control Hosp Epidemiol"},{"issue":"11","key":"5788_CR15","doi-asserted-by":"publisher","first-page":"1500","DOI":"10.1086\/340399","volume":"34","author":"M Hildy","year":"2002","unstructured":"Hildy M, Brown-Elliott BA, Douglas M, Curry J, Cecile T, Yansheng Z, Wallace RJ Jr. An outbreak of Mycobacterium chelonae infection following liposuction. Clin Infect Dis. 2002;34(11):1500\u20137.","journal-title":"Clin Infect Dis"},{"issue":"6","key":"5788_CR16","doi-asserted-by":"publisher","first-page":"2142","DOI":"10.1128\/JCM.00273-12","volume":"50","author":"WP Lu","year":"2012","unstructured":"Lu WP, Lin GX, Shi S, Dong JH. Simultaneously high prevalence of hepatitis B and C virus infection in a population in Putian County. China J Clin Microbiol. 2012;50(6):2142\u20134.","journal-title":"China J Clin Microbiol"},{"issue":"10","key":"5788_CR17","doi-asserted-by":"publisher","first-page":"858","DOI":"10.3855\/jidc.11433","volume":"13","author":"G Panta","year":"2019","unstructured":"Panta G, Richardson AK, Shaw IC. Effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities. J Infect Dev Ctries. 2019;13(10):858\u201364.","journal-title":"J Infect Dev Ctries"},{"key":"5788_CR18","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1371\/journal.pone.0225595","volume":"14","author":"G Panta","year":"2019","unstructured":"Panta G, Richardson AK, Shaw IC, Chambers S, Coope PA. Effectiveness of steam sterilization of reusable medical devices in primary and secondary care public hospitals in Nepal and factors associated with ineffective sterilization: A nation-wide cross-sectional study. PloS One. 2019;14:11.","journal-title":"PloS One"},{"issue":"10","key":"5788_CR19","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1017\/ice.2015.160","volume":"36","author":"K Weinshel","year":"2015","unstructured":"Weinshel K, Dramowski A, Hajdu \u00c1, Jacob S, Khanal B, Zolt\u00e1n M, Mougkou K, Phukan C, Staneloni MI, Singh N. Gap analysis of infection control practices in low-and middle-income countries. Infect Control Hosp Epidemiol. 2015;36(10):1208\u201314.","journal-title":"Infect Control Hosp Epidemiol"},{"issue":"7655","key":"5788_CR20","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1136\/bmj.39527.628322.AD","volume":"336","author":"A Benjamin","year":"2008","unstructured":"Benjamin A. Audit: how to do it in practice. BMJ. 2008;336(7655):1241\u20135.","journal-title":"BMJ."},{"issue":"9","key":"5788_CR21","doi-asserted-by":"publisher","first-page":"E22","DOI":"10.1038\/bdj.2007.124","volume":"202","author":"J Bagg","year":"2007","unstructured":"Bagg J, Smith AJ, Hurrell D, McHugh S, Irvine G. Pre-sterilisation cleaning of re-usable instruments in general dental practice. Br Dent J. 2007;202(9):E22.","journal-title":"Br Dent J"},{"key":"5788_CR22","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1186\/1748-5908-4-31","volume":"4","author":"D Bonetti","year":"2009","unstructured":"Bonetti D, Young L, Black I, Cassie H, Ramsay CR, Clarkson J. Can't do it, won't do it! Developing a theoretically framed intervention to encourage better decontamination practice in Scottish dental practices. Implement Sci. 2009;4:31.","journal-title":"Implement Sci"},{"issue":"6","key":"5788_CR23","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1177\/175717740300400605","volume":"4","author":"T Cooper","year":"2003","unstructured":"Cooper T, Tait J, Bingham P. Decontamination in primary care: development and implementation of a quality improvement programme using audit. Br J Infect Contr. 2003;4(6):15\u201320.","journal-title":"Br J Infect Contr"},{"issue":"10","key":"5788_CR24","first-page":"S128","volume":"88","author":"S Danchaivijitr","year":"2005","unstructured":"Danchaivijitr S. Development of quality indicators for sterilization practices of the central sterile supply department. J Med Assoc Thail. 2005;88(10):S128\u201332.","journal-title":"J Med Assoc Thail"},{"issue":"2","key":"5788_CR25","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1093\/oxfordjournals.pubmed.a024738","volume":"20","author":"L Finn","year":"1998","unstructured":"Finn L, Crook S. Minor surgery in general practice-setting the standards. J Public Health. 1998;20(2):169\u201374.","journal-title":"J Public Health"},{"issue":"1","key":"5788_CR26","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/S1413-8670(11)70139-8","volume":"15","author":"JK Matsuda","year":"2011","unstructured":"Matsuda JK, Grinbaum RS, Davidowicz H. The assessment of infection control in dental practices in the municipality of S\u00e3o Paulo. Braz J Infect Dis. 2011;15(1):45\u201351.","journal-title":"Braz J Infect Dis"},{"issue":"3","key":"5788_CR27","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1053\/jhin.2001.1074","volume":"49","author":"O McNally","year":"2001","unstructured":"McNally O, Thompson IM, McIlvenny G, Smyth ETM, McBride N, MacAuley D. Sterilization and disinfection in general practice within university health services. J Hosp Infect. 2001;49(3):210\u20134 https:\/\/doi.org\/10.1053\/jhin.2001.1074.","journal-title":"J Hosp Infect."},{"issue":"8","key":"5788_CR28","doi-asserted-by":"publisher","first-page":"E16","DOI":"10.1038\/bdj.2007.912","volume":"203","author":"AJ Smith","year":"2007","unstructured":"Smith AJ, Bagg J, Hurrell D, McHugh S. Sterilisation of re-usable instruments in general dental practice. Br Dent J. 2007;203(8):E16.","journal-title":"Br Dent J"},{"issue":"8","key":"5788_CR29","doi-asserted-by":"publisher","first-page":"E20","DOI":"10.1038\/bdj.2007.125","volume":"202","author":"AJ Smith","year":"2007","unstructured":"Smith AJ, Hurrell D, Bagg J, McHugh S, Mathewson H, Henry M. (b). A method for surveying instrument decontamination procedures in general dental practice. Br Dent J. 2007;202(8):E20.","journal-title":"Br Dent J"},{"key":"5788_CR30","unstructured":"Acosta-Gnass SI, Stempliuk VDA. Sterilization manual for health centers. 2009. https:\/\/www.medbox.org\/preview\/5255d6fb-b598-4b60-b19a-02b60e695ecc\/doc.pdf. Accessed 4 Feb 2015."},{"key":"5788_CR31","unstructured":"Centers for Disease Control and Prevention. Infection prevention checklist for outpatient settings: Minimum expectations for safe care. 2014. https:\/\/www.cdc.gov\/hai\/settings\/outpatient\/outpatient-care-guidelines.html. Accessed 2 Feb 2015."},{"key":"5788_CR32","unstructured":"Centers for Medicare and Medicaid Services. Exhibit 351: Ambulatory Surgical Center (ASC) infection control surveyor worksheet. 2013. https:\/\/www.cms.gov\/Regulations-and-Guidance\/Guidance\/Manuals\/downloads\/som107_exhibit_351.pdf. Accessed 12 Mar 2015."},{"key":"5788_CR33","unstructured":"Centers for Medicare and Medicaid Services. Hospital infection control worksheet. 2015. https:\/\/www.cms.gov\/medicare\/provider-enrollment-and-certification\/surveycertificationgeninfo\/downloads\/survey-and-cert-letter-15-12-attachment-1.pdf. Accessed 25 Jun 2015."},{"key":"5788_CR34","volume-title":"Sterilization of health care products - moist heat - part 1: requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 17665-1:2006 E)","author":"International Organization for Standardization","year":"2006","unstructured":"International Organization for Standardization. Sterilization of health care products - moist heat - part 1: requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 17665-1:2006 E). Geneva: ISO; 2006."},{"key":"5788_CR35","volume-title":"Sterilization of health care products - moist heat - part 2: guidance on the application of ISO 17665-1 (ISO\/TS 17665\u20132:2009 E)","author":"International Organization for Standardization","year":"2009","unstructured":"International Organization for Standardization. Sterilization of health care products - moist heat - part 2: guidance on the application of ISO 17665-1 (ISO\/TS 17665\u20132:2009 E). Geneva: ISO; 2009."},{"key":"5788_CR36","volume-title":"Sterilization of health care products - moist heat - part 3: guidance on the designation of a medical device to a product family and processing category for steam sterilization ( ISO\/TS 17665\u20133:2013 E)","author":"International Organization for Standardization","year":"2013","unstructured":"International Organization for Standardization. Sterilization of health care products - moist heat - part 3: guidance on the designation of a medical device to a product family and processing category for steam sterilization ( ISO\/TS 17665\u20133:2013 E). Geneva: ISO; 2013."},{"key":"5788_CR37","volume-title":"Infection prevention and healthcare waste management training - handbook for participants","author":"National Health Training Center - Ministry of Health and Population - Government of Nepal","year":"2015","unstructured":"National Health Training Center - Ministry of Health and Population - Government of Nepal. Infection prevention and healthcare waste management training - handbook for participants. Kathmandu: National Health Training Center; 2015."},{"key":"5788_CR38","volume-title":"Reference manual for infection prevention and healthcare waste management","author":"National Health Training Center - Ministry of Health and Population - Government of Nepal","year":"2015","unstructured":"National Health Training Center - Ministry of Health and Population - Government of Nepal. Reference manual for infection prevention and healthcare waste management. Kathmandu: National Health Training Center; 2015."},{"key":"5788_CR39","unstructured":"Provincial Infectious Diseases Advisory Committee - Public Health Ontario. Best practices in cleaning, disinfection and sterilization of medical equipment\/devices in all health care settings. 2013. http:\/\/www.publichealthontario.ca\/en\/eRepository\/PIDAC_Cleaning_Disinfection_and_Sterilization_2013.pdf. Accessed 25 Jun 2015."},{"key":"5788_CR40","unstructured":"Rutala WA, Weber DJ, Healthcare Infection Control Practices Advisory Committee. Guideline for disinfection and sterilization in healthcare facilities. 2008. https:\/\/www.cdc.gov\/hicpac\/pdf\/guidelines\/Disinfection_Nov_2008.pdf. Accessed 9 Feb 2015."},{"key":"5788_CR41","unstructured":"Scottish Dental Clinical Effectiveness Programme. Cleaning of dental instruments - dental clinical guidance. 2014. http:\/\/www.sdcep.org.uk\/wp-content\/uploads\/2016\/03\/SDCEP_Cleaning_of_Dental_Instruments_2nd_Edition_Jan2016.pdf. Accessed 5 Sep 2015."},{"key":"5788_CR42","unstructured":"Standards Australia, & Standards New Zealand. Office-based health care facilities - reprocessing of reusable medical and surgical instruments and equipment, and maintenance of the associated environment (AS\/NZS 4815:2006). 2006. https:\/\/shop.standards.govt.nz\/catalog\/4815%3A2006%28AS%7CNZS%29\/view?client=html5. Accessed 3 Mar 2015."},{"key":"5788_CR43","unstructured":"International Organization for Standardization. Consumers and standards: Partnership for a better world. 2020. https:\/\/www.iso.org\/sites\/ConsumersStandards\/1_standards.html. Accessed 29 Aug 2020."},{"key":"5788_CR44","unstructured":"International Organization for Standardization. Standardization and related activities - General vocabulary. 2004. https:\/\/isotc.iso.org\/livelink\/livelink\/fetch\/2000\/2122\/4230450\/8389141\/ISO_IEC_Guide_2_2004_%28Multilingual%29_-_Standardization_and_related_activities_%2D%2D_General_vocabulary.pdf?nodeid=8387841&vernum=-2. Accessed 2 Sep 2020."},{"key":"5788_CR45","unstructured":"Department of Health Services\u2014Ministry of Health and Population\u2014Government of Nepal. Annual report 2013\/2014. http:\/\/dohs.gov.np\/wp-content\/uploads\/2014\/04\/Annual_Report_2070_71.pdf. Accessed 17 Aug 2015."},{"key":"5788_CR46","unstructured":"IBM Knowledge Center. One-way ANOVA post hoc tests. 2017. https:\/\/www.ibm.com\/support\/knowledgecenter\/en\/SSLVMB_23.0.0\/spss\/base\/idh_onew_post.html. Accessed 13 Dec, 2017."},{"key":"5788_CR47","first-page":"1049","volume-title":"Disinfection, sterilization, and preservation","author":"CH Miller","year":"2001","unstructured":"Miller CH, Palenik CJ. Sterilization, disinfection, and asepsis in dentistry. In: Block SS, editor. Disinfection, sterilization, and preservation. 5th ed. Philadelphia: Lippincott Williams & Wilkins; 2001. p. 1049\u201368.","edition":"5"},{"key":"5788_CR48","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1533\/9780857096692.1.42","volume-title":"Decontamination in hospitals and healthcare","author":"R Bancroft","year":"2014","unstructured":"Bancroft R. The role of standards in decontamination. In: Walker JT, editor. Decontamination in hospitals and healthcare. 1st ed. Cambridge: Woodhead Publishing; 2014. p. 42\u20139.","edition":"1"},{"issue":"2","key":"5788_CR49","first-page":"108","volume":"16","author":"SK Shrestha","year":"2006","unstructured":"Shrestha SK, Bhattarai MD. Study of hepatitis B among different categories of health care workers. J Coll Physicians Surg Pak. 2006;16(2):108\u201311.","journal-title":"J Coll Physicians Surg Pak"},{"issue":"9","key":"5788_CR50","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1016\/j.ajic.2006.01.010","volume":"34","author":"MJ Alfa","year":"2006","unstructured":"Alfa MJ, Olson N, DeGagne P. Automated washing with the reliance endoscope processing system and its equivalence to optimal manual cleaning. Am J Infect Control. 2006;34(9):561\u201370.","journal-title":"Am J Infect Control"},{"issue":"5","key":"5788_CR51","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1016\/j.ajic.2014.12.018","volume":"43","author":"ES de Souza","year":"2015","unstructured":"de Souza ES, dos Santos SG, de Resende Stoianoff MA, de Oliveira AC. Analysis of microbial load on surgical instruments after clinical use and following manual and automated cleaning. Am J Infect Control. 2015;43(5):522\u20137.","journal-title":"Am J Infect Control"},{"issue":"4","key":"5788_CR52","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1097\/SGA.0b013e3181e9431a","volume":"33","author":"CL Ofstead","year":"2010","unstructured":"Ofstead CL, Wetzler HP, Snyder AK, Horton RA. Endoscope reprocessing methods: a prospective study on the impact of human factors and automation. Gastroenterol Nurs. 2010;33(4):304\u201311.","journal-title":"Gastroenterol Nurs"},{"issue":"5","key":"5788_CR53","doi-asserted-by":"publisher","first-page":"S77","DOI":"10.1016\/j.ajic.2012.12.008","volume":"41","author":"CG Roberts","year":"2013","unstructured":"Roberts CG. The role of biofilms in reprocessing medical devices. Am J Infect Control. 2013;41(5):S77\u201380.","journal-title":"Am J Infect Control"},{"issue":"2","key":"5788_CR54","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.cpen.2009.01.002","volume":"4","author":"R Seavey","year":"2009","unstructured":"Seavey R. The need for educated staff in sterile processing - patient safety depends on it. Perioperative Nursing Clinics. 2009;4(2):181\u201392.","journal-title":"Perioperative Nursing Clinics"},{"issue":"5","key":"5788_CR55","doi-asserted-by":"publisher","first-page":"S56","DOI":"10.1016\/j.ajic.2012.12.006","volume":"41","author":"MJ Alfa","year":"2013","unstructured":"Alfa MJ. Monitoring and improving the effectiveness of cleaning medical and surgical devices. Am J Infect Control. 2013;41(5):S56\u20139.","journal-title":"Am J Infect Control"},{"issue":"2","key":"5788_CR56","first-page":"8","volume":"21","author":"R Barrett","year":"2003","unstructured":"Barrett R, Stevens J, Taranter J. A shelf-life trial: examining the efficacy of event related sterility principles and its implications for nursing practice. Aust J Adv Nurs. 2003;21(2):8\u201312.","journal-title":"Aust J Adv Nurs"},{"issue":"4","key":"5788_CR57","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1016\/S1015-9584(09)60303-1","volume":"26","author":"W Bhumisirikul","year":"2003","unstructured":"Bhumisirikul W, Bhumisirikul P, Pongchairerks P. Long-term storage of small surgical instruments in autoclaved packages. Asian J Surg. 2003;26(4):202\u20134.","journal-title":"Asian J Surg"},{"issue":"1","key":"5788_CR58","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.jhin.2015.01.013","volume":"90","author":"JVDG Hoyos","year":"2015","unstructured":"Hoyos JVDG, van Wezel RAC, van Doornmalen HWJM. Case study on the orientation of phaco hand pieces during steam sterilization processes. J Hos Infect. 2015;90(1):52\u20138.","journal-title":"J Hos Infect"},{"key":"5788_CR59","first-page":"104","volume-title":"Sterilization technology for the healthcare facility","author":"RM Proietti","year":"1997","unstructured":"Proietti RM. Sterilization process monitoring: chemical indicators. In: Reichert M, Young JH, editors. Sterilization technology for the healthcare facility. 2nd ed. Gaithersburg: Aspen Publishers; 1997. p. 104\u20139.","edition":"2"},{"issue":"2","key":"5788_CR60","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.jiph.2016.06.009","volume":"10","author":"D Basu","year":"2017","unstructured":"Basu D. Reason behind wet pack after steam sterilization and its consequences: an overview from central sterile supply department of a cancer center in eastern India. J Infect Public Heal. 2017;10(2):235\u20139.","journal-title":"J Infect Public Heal"},{"key":"5788_CR61","volume-title":"Sterilization of medical supplies by steam: general theory","author":"J Huys","year":"2010","unstructured":"Huys J. Sterilization of medical supplies by steam: general theory. 3rd ed. MHP Verlag GmbH and Heart Consultancy: Wageningen; 2010.","edition":"3"},{"issue":"2","key":"5788_CR62","doi-asserted-by":"publisher","first-page":"76","DOI":"10.3126\/ijim.v1i2.7410","volume":"1","author":"S Pradhan","year":"2013","unstructured":"Pradhan S, Shrestha C. Microbiological surveillance of hospital environment in a medical College Hospital in Kathmandu, Nepal. Int J Infect Microbiol. 2013;1(2):76\u20139.","journal-title":"Int J Infect Microbiol"},{"issue":"1","key":"5788_CR63","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4066\/AMJ.2015.2558","volume":"9","author":"B Sapkota","year":"2016","unstructured":"Sapkota B, Gupta GK, Shrestha SK, Pradhan A, Karki P, Thapa A. Microbiological burden in air culture at various units of a tertiary care government hospital in Nepal. Australas Med J. 2016;9(1):1.","journal-title":"Australas Med J"}],"container-title":["BMC Health Services Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12913-020-05788-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12913-020-05788-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12913-020-05788-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,7]],"date-time":"2021-10-07T03:07:38Z","timestamp":1633576058000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmchealthservres.biomedcentral.com\/articles\/10.1186\/s12913-020-05788-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,7]]},"references-count":63,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["5788"],"URL":"https:\/\/doi.org\/10.1186\/s12913-020-05788-0","relation":{},"ISSN":["1472-6963"],"issn-type":[{"value":"1472-6963","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,7]]},"assertion":[{"value":"7 June 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 September 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 October 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"An ethical clearance was obtained from the Human Ethics Committee of the University of Canterbury (HEC 2015\/139). In addition, an approval was also obtained from the Nepal Health Research Council (NHRC). Written consent was obtained from the medical superintendent or official in charge of each of the thirteen selected hospitals before initiating study activities in the hospitals.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors have declared that no competing interests exist.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"923"}}