{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T08:42:27Z","timestamp":1786178547946,"version":"build-2736575974"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T00:00:00Z","timestamp":1786147200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T00:00:00Z","timestamp":1786147200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100012320","name":"Otto-von-Guericke-Universit\u00e4t Magdeburg","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100012320","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Health Serv Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Methodological and technical education of nurses is required to address challenges of technology integration in peritoneal dialysis (PD). We analysed the nature of therapy interrupting system errors in automated peritoneal dialysis (APD) cyclers of a German PD reference care centre and provide applicable resolution proposals.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We documented therapy interrupting system errors of HomeChoice Pro and HomeChoice Claria cyclers (Baxter, BX, Unterschlei\u00dfheim, Germany) including the years 2015-2023. We systematically characterise and suggest resolution strategies to these errors based on routinely collected health data and user experience to safely guide nephrology professionals and patients during troubleshooting. The \u2018reporting of studies conducted using observational routinely collected health data\u2019 (RECORD)-statement was considered.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>We identified 49 different therapy interrupting system errors which were assigned to eight major categories: Errors associated to the pressure chamber (N=18), the Digitalboard\/EEPROM (N=18, Electrically Erasable Programmable Read Only Memory), air in set (N=3), opening of the set\u2019s door (N=3), those associated to the energy system (N=3), the heater system (N=3) and a variety of errors resulting in an abrupt termination or non-commencement of the treatment session without clear group assignment (undefined, N=1) or without sufficient documentation. In total, 138 error incidents were documented during the observational timeframe. In frequential order errors were attributed to the pressure chamber (21.74%,), and air in set (19.57%) where specifically error 2240 occurred in 17.39% of total cases, the Digitalboard\/EEPROM (17.39%), the energy or battery (16.67%; No. 1032 in 19\/23 cases), the set\u2019s door (7.25%) and the heater (4.35%). In 17 cases (12.32%) no error number was documented by the patient or staff. One error cause was registered as undefined (0.72%). Overall, errors were rarely occurring in &lt;0.25% of treatment sessions performed in the observational timeframe.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>These findings may be useful to guide training purposes for nephrology personnel and persons doing APD. For the manufacturer, the information provided may be helpful to improve error management and information transmission to the persons doing APD with the HomeChoice devices.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12913-026-15289-1","type":"journal-article","created":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T02:51:39Z","timestamp":1786157499000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Characterisation and management of therapy-interrupting system errors associated with the use of the HomeChoice cycler for automated peritoneal dialysis"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5611-1506","authenticated-orcid":false,"given":"Annemarie","family":"Albert","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Richter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rainer Peter","family":"Woitas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6103-9038","authenticated-orcid":false,"given":"Philipp","family":"Stieger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3888-6532","authenticated-orcid":false,"given":"R\u00fcdiger C.","family":"Braun-Dullaeus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6956-9962","authenticated-orcid":false,"given":"Christian","family":"Albert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,8]]},"reference":[{"key":"15289_CR1","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1093\/ndt\/gfv464","volume":"32","author":"M Robinski","year":"2017","unstructured":"Robinski M, Mau W, Wienke A, Girndt M. The Choice of Renal Replacement Therapy (CORETH) project: dialysis patients\u2019 psychosocial characteristics and treatment satisfaction. Nephrol Dial Transpl. 2017;32:315\u201324. https:\/\/doi.org\/10.1093\/ndt\/gfv464.","journal-title":"Nephrol Dial Transpl"},{"key":"15289_CR2","doi-asserted-by":"publisher","first-page":"1542","DOI":"10.1093\/ndt\/gfr452","volume":"27","author":"D Chanouzas","year":"2012","unstructured":"Chanouzas D, Ng KP, Fallouh B, Baharani J. What influences patient choice of treatment modality at the pre-dialysis stage? Nephrol Dial Transpl. 2012;27:1542\u20137. https:\/\/doi.org\/10.1093\/ndt\/gfr452.","journal-title":"Nephrol Dial Transpl"},{"key":"15289_CR3","doi-asserted-by":"publisher","first-page":"e0258440","DOI":"10.1371\/journal.pone.0258440","volume":"16","author":"M Vera","year":"2021","unstructured":"Vera M, Cheak BB, Chmel\u00ed\u010dkov\u00e1 H, Bavanandan S, Goh BL, Halim AGA, et al. Current clinical practice in adapted automated peritoneal dialysis (aAPD)\u2014A prospective, non-interventional study. PLoS ONE. 2021;16:e0258440. https:\/\/doi.org\/10.1371\/journal.pone.0258440.","journal-title":"PLoS ONE"},{"key":"15289_CR4","doi-asserted-by":"publisher","first-page":"1973","DOI":"10.1093\/ndt\/gfp780","volume":"25","author":"DW Johnson","year":"2010","unstructured":"Johnson DW, Hawley CM, McDonald SP, Brown FG, Rosman JB, Wiggins KJ, et al. Superior survival of high transporters treated with automated versus continuous ambulatory peritoneal dialysis. Nephrol Dial Transpl. 2010;25:1973\u20139. https:\/\/doi.org\/10.1093\/ndt\/gfp780.","journal-title":"Nephrol Dial Transpl"},{"key":"15289_CR5","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1159\/000496302","volume":"197","author":"A Giuliani","year":"2019","unstructured":"Giuliani A, Crepaldi C, Manani SM, Samoni S, Cannone M, Cal MD, et al. Evolution of Automated Peritoneal Dialysis Machines. Contrib Nephrol. 2019;197:9\u201316. https:\/\/doi.org\/10.1159\/000496302.","journal-title":"Contrib Nephrol"},{"key":"15289_CR6","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1159\/000496317","volume":"197","author":"C Crepaldi","year":"2019","unstructured":"Crepaldi C, Giuliani A, Manani SM, Marchionna N, Piasentin P, Ronco C. Remote Patient Management in Peritoneal Dialysis: Impact on Clinician\u2019s Practice and Behavior. Contrib Nephrol. 2019;197:44\u201353. https:\/\/doi.org\/10.1159\/000496317.","journal-title":"Contrib Nephrol"},{"key":"15289_CR7","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1186\/s12912-024-01812-4","volume":"23","author":"A Albert","year":"2024","unstructured":"Albert A, Richter S, Kalk P, Stieger P, Woitas RP, Braun-Dullaeus RC, et al. Analysis of a nurse-provided on-call peritoneal dialysis support in an outpatient reference care centre. BMC Nurs. 2024;23:144. https:\/\/doi.org\/10.1186\/s12912-024-01812-4.","journal-title":"BMC Nurs"},{"key":"15289_CR8","doi-asserted-by":"publisher","first-page":"569","DOI":"10.34067\/kid.0000662019","volume":"1","author":"M Ahmad","year":"2020","unstructured":"Ahmad M, Wallace EL, Jain G. Setting Up and Expanding a Home Dialysis Program: Is There a Recipe for Success? Kidney360. 2020;1:569\u201379. https:\/\/doi.org\/10.34067\/kid.0000662019.","journal-title":"Kidney360"},{"key":"15289_CR9","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1053\/j.ajkd.2013.07.009","volume":"63","author":"B Wong","year":"2014","unstructured":"Wong B, Zimmerman D, Reintjes F, Courtney M, Klarenbach S, Dowling G, et al. Procedure-Related Serious Adverse Events Among Home Hemodialysis Patients: A Quality Assurance Perspective. Am J Kidney Dis. 2014;63:251\u20138. https:\/\/doi.org\/10.1053\/j.ajkd.2013.07.009.","journal-title":"Am J Kidney Dis"},{"key":"15289_CR10","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/s0272-6386(03)00540-7","volume":"42","author":"AP Heidenheim","year":"2003","unstructured":"Heidenheim AP, Leitch R, Kortas C, Lindsay RM, Study LDH. Patient monitoring in the london daily\/nocturnal hemodialysis study. Am J Kidney Dis. 2003;42:61\u20135. https:\/\/doi.org\/10.1016\/s0272-6386(03)00540-7.","journal-title":"Am J Kidney Dis"},{"key":"15289_CR11","doi-asserted-by":"publisher","first-page":"e1001885","DOI":"10.1371\/journal.pmed.1001885","volume":"12","author":"EI Benchimol","year":"2015","unstructured":"Benchimol EI, Smeeth L, Guttmann A, Harron K, Moher D, Petersen I, et al. The REporting of studies Conducted using Observational Routinely-collected health Data (RECORD) Statement. PloS Med. 2015;12:e1001885. https:\/\/doi.org\/10.1371\/journal.pmed.1001885.","journal-title":"PloS Med"},{"key":"15289_CR12","unstructured":"The R Development Core Team. R: a language and environment for statistical computing. Vienna, Austria: R Foundation for Statistical Computing. 2023. Available from: http:\/\/www.R-project.org."},{"key":"15289_CR13","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1111\/hdi.12677","volume":"23","author":"F Reintjes","year":"2019","unstructured":"Reintjes F, Herian N, Shah N, Pauly RP. Prospective monitoring of after-hours nursing and technologist support calls to a regional Canadian home hemodialysis program. Hemodial Int. 2019;23:19\u201325. https:\/\/doi.org\/10.1111\/hdi.12677.","journal-title":"Hemodial Int"},{"key":"15289_CR14","doi-asserted-by":"publisher","first-page":"sfae067","DOI":"10.1093\/ckj\/sfae067","volume":"17","author":"A Albert","year":"2024","unstructured":"Albert A, Richter S, Woitas RP, Hinkel UP, Stieger P, Braun-Dullaeus RC, et al. Baxter Physioneal, Extraneal, Nutrineal (PEN) and Dianeal solution bags can be accidentally connected to Fresenius peritoneal dialysis catheter extensions in a non-sterile manner. Clin Kidney J. 2024;17:sfae067. https:\/\/doi.org\/10.1093\/ckj\/sfae067.","journal-title":"Clin Kidney J"},{"key":"15289_CR15","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1055\/a-2534-0788","volume":"29","author":"A Albert","year":"2025","unstructured":"Albert A, Richter S, Woitas RP, Albert C. Individuelles und zeitliches Nutzungsverhalten, Dringlichkeit und Therapiekonsequenz einer telefonischen Rufbereitschaft f\u00fcr Peritonealdialysepatienten. Nephrol aktuell. 2025;29:212\u20138. https:\/\/doi.org\/10.1055\/a-2534-0788.","journal-title":"Nephrol aktuell"},{"key":"15289_CR16","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1017\/s0266462312000694","volume":"29","author":"ESM Hilbers","year":"2013","unstructured":"Hilbers ESM, de Vries CGJCA, Geertsma RE. Medical technology at home: safety-related items in technical documentation. Int J Technol Assess Health Care. 2013;29:20\u20136. https:\/\/doi.org\/10.1017\/s0266462312000694.","journal-title":"Int J Technol Assess Health Care"},{"key":"15289_CR17","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/s1075-4210(99)90034-2","volume":"5","author":"MH Reid","year":"1999","unstructured":"Reid MH, Sawyer D. The human factors implications of peritoneal dialysis: Cycler overfill incident reports. Int J Trauma Nurs. 1999;5:68\u201371. https:\/\/doi.org\/10.1016\/s1075-4210(99)90034-2.","journal-title":"Int J Trauma Nurs"},{"key":"15289_CR18","doi-asserted-by":"publisher","first-page":"636","DOI":"10.1177\/089686089601600616","volume":"16","author":"LP Ponferrada","year":"1996","unstructured":"Ponferrada LP, Prowant BF, Rackers JA, Pickett B, Satalowich R, Khanna R, et al. A cluster of gram-negative peritonitis episodes associated with reuse of HomeChoice cycler cassettes and drain lines. Perit Dial Int. 1996;16:636\u20138.","journal-title":"Perit Dial Int"},{"key":"15289_CR19","doi-asserted-by":"publisher","first-page":"583","DOI":"10.3747\/pdi.2012.00231","volume":"33","author":"G Agarwal","year":"2013","unstructured":"Agarwal G, Foster D, Schlageter K, Jones L, Jorgensen L, Wilkinson S, et al. Increase in Peritonitis Rates with the Reuse of Drain Tubing of the Fresenius Liberty Cycler. Perit Dial Int. 2013;33:583\u20135. https:\/\/doi.org\/10.3747\/pdi.2012.00231.","journal-title":"Perit Dial Int"},{"key":"15289_CR20","unstructured":"Bundesinstitut f\u00fcr Arzneimittel und Medizinprodukte (BfArM); Baxter Healthcare. Product information regarding system error 2240 and 2267 on HomeChoice Cyclers. Reference No. 01814\/07 [Internet]. Germany: BfArM; 2007 [cited 2023 Oct 25]. Available from: https:\/\/www.bfarm.de\/SharedDocs\/Kundeninfos\/DE\/07\/2007\/01814-07_kundeninfo_de.pdf."},{"key":"15289_CR21","doi-asserted-by":"publisher","first-page":"e20230142","DOI":"10.1590\/2175-8239-jbn-2023-0142en","volume":"46","author":"EK Franke","year":"2024","unstructured":"Franke EK, Hinkel UP, Albert C. Flow problems during implantation of a peritoneal dialysis catheter: building a capnoperitoneum using the peritoneal dialysis catheter. Braz J Nephrol. 2024;46:e20230142. https:\/\/doi.org\/10.1590\/2175-8239-jbn-2023-0142en.","journal-title":"Braz J Nephrol"},{"key":"15289_CR22","doi-asserted-by":"publisher","first-page":"95","DOI":"10.2147\/mder.s51189","volume":"8","author":"RI Chaudhry","year":"2015","unstructured":"Chaudhry RI, Golper TA. Automated cyclers used in peritoneal dialysis: technical aspects for the clinician. Med Devices (Auckl). 2015;8:95\u2013102. https:\/\/doi.org\/10.2147\/mder.s51189.","journal-title":"Med Devices (Auckl)"},{"key":"15289_CR23","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1186\/1472-6963-4-28","volume":"4","author":"P Lehoux","year":"2004","unstructured":"Lehoux P. Patients\u2019 perspectives on high-tech home care: a qualitative inquiry into the user-friendliness of four technologies. BMC Health Serv Res. 2004;4:28. https:\/\/doi.org\/10.1186\/1472-6963-4-28.","journal-title":"BMC Health Serv Res"},{"key":"15289_CR24","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1186\/s12882-022-02854-z","volume":"23","author":"O El Shamy","year":"2022","unstructured":"El Shamy O, Atallah S, Sharma S, Uribarri J. Comparing the effect of peritoneal dialysis cycler type on patient-reported satisfaction, support needs and treatments. BMC Nephrol. 2022;23:217. https:\/\/doi.org\/10.1186\/s12882-022-02854-z.","journal-title":"BMC Nephrol"},{"key":"15289_CR25","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1007\/s00467-022-05563-9","volume":"38","author":"BU Kenan","year":"2023","unstructured":"Kenan BU, Kilic BD, Kara MA, Taktak A, Bayazit AK, Yildirim ZNY, et al. Evaluation of the Claria sharesource system from the perspectives of patient\/caregiver, physician, and nurse in children undergoing automated peritoneal dialysis. Pediatr Nephrol. 2023;38:471\u20137. https:\/\/doi.org\/10.1007\/s00467-022-05563-9.","journal-title":"Pediatr Nephrol"},{"key":"15289_CR26","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1111\/sdi.12114","volume":"26","author":"JH Segal","year":"2013","unstructured":"Segal JH, Messana JM. Prevention of Peritonitis in Peritoneal Dialysis. Semin Dialysis. 2013;26:494\u2013502. https:\/\/doi.org\/10.1111\/sdi.12114.","journal-title":"Semin Dialysis"},{"key":"15289_CR27","doi-asserted-by":"publisher","first-page":"205435812211505","DOI":"10.1177\/20543581221150590","volume":"10","author":"S Zheng","year":"2023","unstructured":"Zheng S, Auguste BL. Five Things to Know About Volume Overload in Peritoneal Dialysis. Can J Kidney Heal Dis. 2023;10:20543581221150590. https:\/\/doi.org\/10.1177\/20543581221150590.","journal-title":"Can J Kidney Heal Dis"},{"key":"15289_CR28","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1093\/ckj\/sfz175","volume":"14","author":"F Vrtovsnik","year":"2019","unstructured":"Vrtovsnik F, Verger C, Biesen WV, Fan S, Shin S-K, Rodr\u00edguez C, et al. The impact of volume overload on technique failure in incident peritoneal dialysis patients. Clin Kidney J. 2019;14:570\u20137. https:\/\/doi.org\/10.1093\/ckj\/sfz175.","journal-title":"Clin Kidney J"},{"key":"15289_CR29","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1038\/nrneph.2016.181","volume":"13","author":"PK-T Li","year":"2017","unstructured":"Li PK-T, Chow KM, de Luijtgaarden MWMV, Johnson DW, Jager KJ, Mehrotra R, et al. Changes in the worldwide epidemiology of peritoneal dialysis. Nat Rev Nephrol. 2017;13:90\u2013103. https:\/\/doi.org\/10.1038\/nrneph.2016.181.","journal-title":"Nat Rev Nephrol"},{"key":"15289_CR30","doi-asserted-by":"publisher","first-page":"1490","DOI":"10.2215\/cjn.0000000000000284","volume":"18","author":"GE Abra","year":"2023","unstructured":"Abra GE, Weinhandl ED, Hussein WF. Setting Up Home Dialysis Programs. Clin J Am Soc Nephrol. 2023;18:1490\u20136. https:\/\/doi.org\/10.2215\/cjn.0000000000000284.","journal-title":"Clin J Am Soc Nephrol"},{"key":"15289_CR31","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1007\/s40620-020-00812-2","volume":"33","author":"SM Manani","year":"2020","unstructured":"Manani SM, Baretta M, Giuliani A, Virz\u00ec GM, Martino F, Crepaldi C, et al. Remote monitoring in peritoneal dialysis: benefits on clinical outcomes and on quality of life. J Nephrol. 2020;33:1301\u20138. https:\/\/doi.org\/10.1007\/s40620-020-00812-2.","journal-title":"J Nephrol"},{"key":"15289_CR32","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1186\/1471-2369-13-13","volume":"13","author":"E Rygh","year":"2012","unstructured":"Rygh E, Arild E, Johnsen E, Rumpsfeld M. Choosing to live with home dialysis-patients\u2019 experiences and potential for telemedicine support: a qualitative study. BMC Nephrol. 2012;13:13\u201313. https:\/\/doi.org\/10.1186\/1471-2369-13-13.","journal-title":"BMC Nephrol"},{"key":"15289_CR33","doi-asserted-by":"publisher","first-page":"2673","DOI":"10.1007\/s11255-022-03178-5","volume":"54","author":"K Uchiyama","year":"2022","unstructured":"Uchiyama K, Morimoto K, Washida N, Kusahana E, Nakayama T, Itoh T, et al. Effects of a remote patient monitoring system for patients on automated peritoneal dialysis: a randomized crossover controlled trial. Int Urol Nephrol. 2022;54:2673\u201381. https:\/\/doi.org\/10.1007\/s11255-022-03178-5.","journal-title":"Int Urol Nephrol"}],"container-title":["BMC Health Services Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12913-026-15289-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12913-026-15289-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12913-026-15289-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T07:54:08Z","timestamp":1786175648000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12913-026-15289-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,8]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["15289"],"URL":"https:\/\/doi.org\/10.1186\/s12913-026-15289-1","relation":{},"ISSN":["1472-6963"],"issn-type":[{"value":"1472-6963","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,8]]},"assertion":[{"value":"18 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This retrospective analysis of routinely collected clinical patient record data was part of an internal quality improvement program. Due to the retrolective nature of this investigation, necessity for patient consent to participate was exempt by the institutional review board of Diaverum Germany in accordance with German legal requirements (\u00a7\u00a027 BDSG, Bundesdatenschutzgesetz) enabling anonymized \u2018data processing for scientific or historical research purposes\u2019. The study protocol was in concordance with the ethical guidelines of the Declaration of Helsinki and was approved by the institutional review board of Diaverum Germany and the Otto-von-Guericke University Medical Faculty Ethics Committee, Magdeburg, Germany, Case No. 142\/22.","order":1,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"1067"}}