{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T04:55:51Z","timestamp":1784004951769,"version":"3.55.0"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,8,2]],"date-time":"2023-08-02T00:00:00Z","timestamp":1690934400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,8,2]],"date-time":"2023-08-02T00:00:00Z","timestamp":1690934400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Vet Res"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The objective of this study was to investigate the effects of locking plugs and the biomechanical properties of a 3.5\u00a0mm 8-hole polyaxial locking plate in a fracture gap model. Our hypothesis was that locking plugs would increase the strength and stiffness of the construct. Twelve 3.5\u00a0mm 8-hole plates were used to evaluate two different construct designs (with locking plugs vs. without locking plugs) with validated bone substitutes in a 25\u00a0mm bridging osteosynthesis gap model. Each construct was subjected to a single cycle four-point bending load to failure using a servo-hydraulic testing machine. Bending stiffness, bending strength, and bending structural stiffness were calculated and compared using an unpaired Student\u00b4s t-test.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The plating construct with locking plugs did not show any significant increase in terms of bending stiffness, bending strength, and bending structural stiffness compared to plating construct without locking plugs in a 25\u00a0mm gap fracture model during a single cycle four-point bending.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Under the conditions tested, filling empty plate holes with locking plugs in bridging osteosynthesis does not increase stiffness or strength of the plate-bone construct.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12917-023-03660-x","type":"journal-article","created":{"date-parts":[[2023,8,2]],"date-time":"2023-08-02T02:01:22Z","timestamp":1690941682000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Do locking plugs improve implant strength? Biomechanical comparison of polyaxial locking constructs with and without locking plugs in a fracture gap model"],"prefix":"10.1186","volume":"19","author":[{"given":"Joni","family":"Viitanen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Quinn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"Allen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bart J. G.","family":"Broeckx","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomasz","family":"Bartkowiak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georg","family":"Haimel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,8,2]]},"reference":[{"key":"3660_CR1","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1111\/j.1532-950X.2010.00783.x","volume":"40","author":"LP Guiot","year":"2011","unstructured":"Guiot LP, Dejardin LM. Prospective evaluation of minimally invasive plate osteosynthesis in 36 nonarticular tibial fractures in dogs and cats. Vet Surg. 2011;40:171\u201382.","journal-title":"Vet Surg"},{"key":"3660_CR2","doi-asserted-by":"publisher","first-page":"175","DOI":"10.3415\/VCOT-08-06-0050","volume":"22","author":"CC Hudson","year":"2009","unstructured":"Hudson CC, Pozzi A, Lewis DD. Minimally invasive plate osteosynthesis: applications and techniques in dogs and cats. Vet Comp Orthop Traumatol. 2009;22:175\u201382.","journal-title":"Vet Comp Orthop Traumatol"},{"key":"3660_CR3","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1186\/s12891-016-1224-3","volume":"17","author":"Z Xue","year":"2016","unstructured":"Xue Z, Jiang C, Hu C, et al. Effects of different surgical techniques on mid-distal humeral shaft fracture vascularity: open reduction and internal fixation versus minimally invasive plate osteosynthesis. BMC Musculoskelet Disord. 2016;17:370.","journal-title":"BMC Musculoskelet Disord"},{"issue":"2","key":"3660_CR4","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1302\/0301-620X.94B2.27440","volume":"94","author":"R Firoozabadi","year":"2012","unstructured":"Firoozabadi R, McDonald E, Nguyen T-Q, et al. Does plugging unused combination screw holes improve the fatigue life of fixation with locking plates in comminuted supracondylar fractures of the femur? J Bone Joint Surg Br. 2012;94(2):241\u20138.","journal-title":"J Bone Joint Surg Br"},{"key":"3660_CR5","doi-asserted-by":"publisher","first-page":"19","DOI":"10.3928\/01477447-20101123-13","volume":"34","author":"JK Eichinger","year":"2011","unstructured":"Eichinger JK, Herzog JP, Arrington ED. Analysis of the mechanical properties of locking plates with and without screw hole inserts. Orthopaedics. 2011;34:19.","journal-title":"Orthopaedics"},{"key":"3660_CR6","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1097\/BOT.0b013e3181dc56b1","volume":"25","author":"J Bellapianta","year":"2011","unstructured":"Bellapianta J, Dow K, Hospodar PP, et al. Threaded screw head inserts improve locking plate biomechanical properties. J Orthop Trauma. 2011;25:65\u201371.","journal-title":"J Orthop Trauma"},{"issue":"12","key":"3660_CR7","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1302\/2046-3758.712.BJR-2018-0083.R1","volume":"7","author":"L-W Hung","year":"2018","unstructured":"Hung L-W, Chao C-K, Huang J-R, et al. Screw head plugs increase the fatigue strength of stainless steel, but not titanium, locking plates. Bone Joint Res. 2018;7(12):629\u201335.","journal-title":"Bone Joint Res"},{"issue":"No2","key":"3660_CR8","first-page":"1","volume":"02","author":"J Cartner","year":"2011","unstructured":"Cartner J, Messina A, Baker C, Russell TA, Tornetta P III, Ricci WM. Does insertion torque affect the mechanics of locking hole inserts and fatigue performance of bridge plate constructs? Bone Joint Sci. 2011;02(No2):1\u20134.","journal-title":"Bone Joint Sci"},{"key":"3660_CR9","doi-asserted-by":"publisher","first-page":"1039","DOI":"10.1007\/s11999-012-2664-1","volume":"471","author":"M Tompkins","year":"2013","unstructured":"Tompkins M, Paller DJ, Moore DC, et al. Locking buttons increase fatigue life of locking plates in a segmental bone defect model. Clin Orthop Relat Res. 2013;471:1039\u201344.","journal-title":"Clin Orthop Relat Res"},{"key":"3660_CR10","unstructured":"Meyers K, et al. The effect of locking inserts and overtorque on the fatigue behavior of locking compression plates. [abstract] 56th Annual Meeting of the Orthopaedic Research Society, 2010."},{"key":"3660_CR11","doi-asserted-by":"publisher","first-page":"88","DOI":"10.3415\/VCOT-14-03-0046","volume":"28","author":"AW Tomlinson","year":"2015","unstructured":"Tomlinson AW, Comerford EJ, Birch RS, et al. Mechanical performance in axial compression of a titanium polyaxial locking plate system in a fracture gap model. Vet Comp Orthop Traumatol. 2015;28:88\u201394.","journal-title":"Vet Comp Orthop Traumatol"},{"key":"3660_CR12","doi-asserted-by":"publisher","first-page":"132","DOI":"10.3415\/VCOT-08-03-0030","volume":"22","author":"MG Ness","year":"2009","unstructured":"Ness MG. The effect of bending and twisting on the stiffness and strength of the 3.5 SOP implant. Vet Comp Orthop Traumatol. 2009;22:132\u20136.","journal-title":"Vet Comp Orthop Traumatol"},{"key":"3660_CR13","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1055\/s-0038-1632446","volume":"8","author":"P Muir","year":"1995","unstructured":"Muir P, Johnsson KA, Markel MD. Area moment of inertia for comparison of implant cross-sectional geometry and bending stiffness. Vet Comp Orthop Traumatol. 1995;8:156\u2013152.","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"1\u20139","key":"3660_CR14","doi-asserted-by":"publisher","first-page":"408","DOI":"10.3415\/VCOT-11-04-0061","volume":"24","author":"CA Blake","year":"2011","unstructured":"Blake CA, Boudrieau RJ, Torrance BS, et al. Single cycle to failure in bending of three standard and five locking plates and plate constructs. Vet Comp Orthop Traumatol. 2011;24(1\u20139):408\u201317.","journal-title":"Vet Comp Orthop Traumatol"},{"key":"3660_CR15","doi-asserted-by":"publisher","first-page":"418","DOI":"10.3415\/VCOT-11-04-0050","volume":"24","author":"JB Cabassu","year":"2011","unstructured":"Cabassu JB, Kowaleski MP, Shorinko JK. Single cycle to failure in torsion of three standard and five locking plate constructs. Vet Comp Orthop Traumatol. 2011;24:418\u201325.","journal-title":"Vet Comp Orthop Traumatol"},{"key":"3660_CR16","volume-title":"Standard Specification and Test Method for Metallic Bone Plates, ASTM F382\u201317 West Conshohocken","author":"American Society for Testing and Materials","year":"2017","unstructured":"American Society for Testing and Materials. Standard Specification and Test Method for Metallic Bone Plates, ASTM F382\u201317 West Conshohocken. PA: ASTM; 2017."},{"key":"3660_CR17","doi-asserted-by":"publisher","first-page":"172","DOI":"10.3415\/VCOT-16-07-0111","volume":"30","author":"C Eid","year":"2017","unstructured":"Eid C, Martini FM, Bonardi A, et al. Single cycle to failure in bending of three titanium polyaxial locking plates. Vet Comp Orthop Traumatol. 2017;30:172\u20137.","journal-title":"Vet Comp Orthop Traumatol"},{"key":"3660_CR18","unstructured":"Standard Operating Procedures for Evolox\u00ae Osteosynthesis Fixation of Fractures. N2 (UK) Ltd, Portsmouth, UK. www.n2-uk.com. Last accessed 29 Apr 2021."},{"key":"3660_CR19","doi-asserted-by":"publisher","first-page":"186","DOI":"10.3415\/VCOT-12-03-0043","volume":"26","author":"BW Bufkin","year":"2013","unstructured":"Bufkin BW, Barnhart MD, Kazanovicz AJ, et al. The effect of screw angulation and insertion torque on the push-out strength of polyaxial locking screws and the single cycle to failure in ben- ding of polyaxial locking plates. Vet Comp Orthop Traumatol. 2013;26:186\u201391.","journal-title":"Vet Comp Orthop Traumatol"},{"key":"3660_CR20","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1186\/1746-6148-9-125","volume":"91","author":"P Chao","year":"2013","unstructured":"Chao P, Conrad BP, Lewis DD, et al. Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4 mm locking compression plate. BMC Vet Res. 2013;91:125.","journal-title":"BMC Vet Res"},{"issue":"04","key":"3660_CR21","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1111\/j.1532-950X.2014.12095.x","volume":"43","author":"RC Malenfant","year":"2014","unstructured":"Malenfant RC, Sod GA. In vitro biomechanical comparison of 3.5 string of pearl plate fixation to 3.5 locking compression plate fixation in a canine fracture gap model. Vet Surg. 2014;43(04):465\u201370.","journal-title":"Vet Surg"},{"key":"3660_CR22","doi-asserted-by":"publisher","first-page":"451","DOI":"10.3415\/VCOT-16-01-0008","volume":"29","author":"T Pearson","year":"2016","unstructured":"Pearson T, Glyde MR, Day RE, et al. The effect of intramedullary pin size and plate working length on plate strain in locking compression plate- rod constructs under axial load. Vet Comp Orthop Traumatol. 2016;29:451\u20138.","journal-title":"Vet Comp Orthop Traumatol"},{"key":"3660_CR23","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1055\/s-0039-1698415","volume":"33","author":"J Kaczmarek","year":"2020","unstructured":"Kaczmarek J, Bartkowiak T, Schuenemann R, et al. Mechanical Performance of a Polyaxial Locking Plate and the Influence of Screw Angulation in a Fracture Gap Model. Vet Comp Orthop Traumatol. 2020;33:36\u201344.","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"07","key":"3660_CR24","doi-asserted-by":"publisher","first-page":"832","DOI":"10.2460\/ajvr.2000.61.832","volume":"61","author":"JE Bertram","year":"2000","unstructured":"Bertram JE, Lee DV, Case HN, Todhunter RJ. Comparison of the trotting gaits of Labrador Retrievers and Greyhounds. Am J Vet Res. 2000;61(07):832\u20138.","journal-title":"Am J Vet Res"}],"container-title":["BMC Veterinary Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12917-023-03660-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12917-023-03660-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12917-023-03660-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,2]],"date-time":"2023-08-02T02:03:46Z","timestamp":1690941826000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcvetres.biomedcentral.com\/articles\/10.1186\/s12917-023-03660-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,2]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["3660"],"URL":"https:\/\/doi.org\/10.1186\/s12917-023-03660-x","relation":{},"ISSN":["1746-6148"],"issn-type":[{"value":"1746-6148","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,2]]},"assertion":[{"value":"8 June 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 July 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 August 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable \u2013biomechanical study with no animals involved.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"104"}}