{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:41:06Z","timestamp":1792788066883,"version":"4.5.0"},"reference-count":10,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,10,18]],"date-time":"2023-10-18T00:00:00Z","timestamp":1697587200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,10,18]],"date-time":"2023-10-18T00:00:00Z","timestamp":1697587200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4ts-Herzzentrum Freiburg - Bad Krozingen GmbH"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Vet Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Anatomic anomalies in the ascending aorta may impair the implantation and testing of cardiovascular devices in humans and animal models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation<\/jats:title>\n                    <jats:p>We present the rare case of an intra-aortic band in a German Landrace pig. During terminal animal testing, the band hindered the implantation of a left ventricular assist device (LVAD) with transventricular outflow graft across the aortic valve. After lower partial sternotomy, epicardial echocardiography displayed an intraluminal echogenic structure at the sinotubular junction causing unspecific flow turbulences. Under cardiopulmonary bypass, coring of the left ventricular apex was performed. Due to strong resistance in the proximal aorta, accurate positioning of the transventricular LVAD outflow graft was impossible. After euthanasia, necropsy revealed a fibrous band located at the sinotubular junction, dividing the lumen of the ascending aorta.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The occurrence of an intra-aortic band represents an extremely rare case of a most likely congenital anomaly. Awareness of such anomalies is important for planning and performing animal testing. Perioperative echocardiography may help to either remove such anomalies or allow discontinuing the procedure prior to device implantation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12917-023-03781-3","type":"journal-article","created":{"date-parts":[[2023,10,18]],"date-time":"2023-10-18T03:02:45Z","timestamp":1697598165000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Intra-aortic band impairs transapical device implantation in a pig: a case report"],"prefix":"10.1186","volume":"19","author":[{"given":"Florian","family":"Meissner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michelle","family":"Costa Galbas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johannes","family":"Dinkelaker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heidi Cristina","family":"Schmitz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hendrik","family":"Straky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johanna","family":"Reuter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Czerny","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wolfgang","family":"Bothe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,10,18]]},"reference":[{"issue":"7","key":"3781_CR1","doi-asserted-by":"publisher","first-page":"e3000411","DOI":"10.1371\/journal.pbio.3000411","volume":"18","author":"N Percie du Sert","year":"2020","unstructured":"Percie du Sert N, Ahluwalia A, Alam S, Avey MT, Baker M, Browne WJ, et al. Reporting animal research: explanation and elaboration for the ARRIVE guidelines 2.0. Boutron I, editor. PLOS Biol. 2020;18(7):e3000411.","journal-title":"PLOS Biol"},{"issue":"7","key":"3781_CR2","doi-asserted-by":"publisher","first-page":"e3000410","DOI":"10.1371\/journal.pbio.3000410","volume":"18","author":"N Percie du Sert","year":"2020","unstructured":"Percie du Sert N, Hurst V, Ahluwalia A, Alam S, Avey MT, Baker M, et al. The ARRIVE guidelines 2.0: updated guidelines for reporting animal research. Boutron I. Editor PLOS Biol. 2020;18(7):e3000410.","journal-title":"Editor PLOS Biol"},{"issue":"4","key":"3781_CR3","doi-asserted-by":"publisher","first-page":"486","DOI":"10.3390\/bioengineering10040486","volume":"10","author":"F Meissner","year":"2023","unstructured":"Meissner F, Eichelkraut D, Schimmel M, Maier S, Vestner H, Schoen M, et al. Impact of an accessory for Left Ventricular Assist Devices on device Flow and pressure Head in Vitro. Bioengineering. 2023;10(4):486.","journal-title":"Bioengineering"},{"key":"3781_CR4","doi-asserted-by":"crossref","unstructured":"Schibilsky D, Scheumann J, Koester PJ, Demir H, Rausch M, Puiu P et al. Development of a Novel Adapter to Enable Less-Invasive Left Ventricular Assist Device Implantation via the Left Ventricular Apex. ASAIO J Am Soc Artif Intern Organs 1992. 2022.","DOI":"10.1097\/MAT.0000000000001719"},{"issue":"16","key":"3781_CR5","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1016\/j.jaccas.2022.06.011","volume":"4","author":"A Shah","year":"2022","unstructured":"Shah A, Goerlich CE, Pasrija C, Hirsch J, Fisher S, Odonkor P, et al. Anatomical differences between Human and Pig Hearts and their relevance for Cardiac Xenotransplantation Surgical technique. JACC Case Rep. 2022;4(16):1049\u201352.","journal-title":"JACC Case Rep"},{"issue":"2","key":"3781_CR6","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.jvc.2011.01.004","volume":"13","author":"DK Ajithdoss","year":"2011","unstructured":"Ajithdoss DK, Arenas-Gamboa AM, Edwards JF. A fibrous band associated with the non-coronary aortic valve cusp in a dog. J Vet Cardiol. 2011;13(2):127\u20139.","journal-title":"J Vet Cardiol"},{"issue":"4","key":"3781_CR7","doi-asserted-by":"publisher","first-page":"e64","DOI":"10.1016\/j.jtcvs.2008.11.036","volume":"139","author":"P Bonde","year":"2010","unstructured":"Bonde P, Yuh DD. Intra-aortic intimal band presenting as an aortic pseudodissection. J Thorac Cardiovasc Surg. 2010;139(4):e64\u20135.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"4","key":"3781_CR8","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1016\/0002-8703(53)90173-2","volume":"45","author":"ET Torres","year":"1953","unstructured":"Torres ET, Cavalcanti AR. Congenital elastic band of aortic valve. Am Heart J. 1953;45(4):630\u20133.","journal-title":"Am Heart J"},{"issue":"5","key":"3781_CR9","first-page":"343","volume":"5","author":"K Nakamura","year":"1999","unstructured":"Nakamura K, Onitsuka T, Nakamura E, Yano M, Matsuzaki Y, Nabeshima K. Rare cases of congenital bicuspid aortic valve with an abnormal fibrous band. Ann Thorac Cardiovasc Surg off J Assoc Thorac Cardiovasc Surg Asia. 1999;5(5):343\u20136.","journal-title":"Ann Thorac Cardiovasc Surg off J Assoc Thorac Cardiovasc Surg Asia"},{"issue":"9","key":"3781_CR10","doi-asserted-by":"publisher","first-page":"1127","DOI":"10.1016\/j.radcr.2019.06.031","volume":"14","author":"CC Shelton","year":"2019","unstructured":"Shelton CC, Tyagi SC, Sanampudi S, Issa MM, Raissi D, Lowry CM, et al. Congenital intravascular abdominal aortic band initially thought to be a metallic foreign body: characterization using microanatomical CT reconstruction technique. Radiol Case Rep. 2019;14(9):1127\u201331.","journal-title":"Radiol Case Rep"}],"container-title":["BMC Veterinary Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12917-023-03781-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12917-023-03781-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12917-023-03781-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,18]],"date-time":"2023-11-18T09:21:08Z","timestamp":1700299268000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcvetres.biomedcentral.com\/articles\/10.1186\/s12917-023-03781-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,18]]},"references-count":10,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["3781"],"URL":"https:\/\/doi.org\/10.1186\/s12917-023-03781-3","relation":{},"ISSN":["1746-6148"],"issn-type":[{"value":"1746-6148","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,18]]},"assertion":[{"value":"20 June 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 October 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 October 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Animal testing was approved by the local ethics committee (Regierungspr\u00e4sidium Freiburg, Germany, approval number 35-9185.81\/G-22\/006). The research was conducted in accordance with the German animal protection law (TierSchG), the European Convention for the Protection of Vertebrate Animals used for Experimental and other Scientific Purposes, and the ARRIVE guidelines 2.0 [\n                      \n                      ,\n                      \n                      ].","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"M.C. is a consultant to Terumo Aortic, Medtronic, Endospan, and NEOS, received speaking honoraria from Cryolife-Jotec, and is a shareholder of TEVAR Ltd. and Ascense Medical. The other authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"212"}}