{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T21:33:18Z","timestamp":1790112798476,"version":"4.0.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,29]],"date-time":"2026-01-29T00:00:00Z","timestamp":1769644800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T00:00:00Z","timestamp":1771804800000},"content-version":"vor","delay-in-days":25,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"The publication was cofinanced by the Science Development Fund of the Warsaw University of Life Sciences \u2013 SGGW"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Vet Res"],"DOI":"10.1186\/s12917-026-05313-1","type":"journal-article","created":{"date-parts":[[2026,1,29]],"date-time":"2026-01-29T10:47:29Z","timestamp":1769683649000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Does the bone drill bit remain sharp after a collision with the intramedullary pin? a study on isolated canine tibias"],"prefix":"10.1186","volume":"22","author":[{"given":"Piotr","family":"Tr\u0119bacz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Micha\u0142","family":"Czopowicz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Magdalena","family":"Antonowicz-H\u00fcpsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karolina","family":"Wilk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Barteczko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mateusz","family":"Pawlik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Agata","family":"Pi\u0105tek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aleksandra","family":"Kurkowska","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,29]]},"reference":[{"key":"5313_CR1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjoms.2004.11.007","author":"W Allan","year":"2005","unstructured":"Allan W, Williams ED, Kerawala CJ. Effects of repeated drill use on the temperature of bone during Preparation for osteosynthetic self-tapping screws. Br J Oral Maxillofac Surg. 2005. https:\/\/doi.org\/10.1016\/j.bjoms.2004.11.007.","journal-title":"Br J Oral Maxillofac Surg"},{"key":"5313_CR2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-015-2338-z","author":"H Clement","year":"2015","unstructured":"Clement H, Zopf C, Brandner M, Tesh NP, Vallant R, Puchwein P. Performance test of different 3.5\u00a0mm drill Bits and consequences for orthopaedic surgery. Arch Orthop Trauma Surg. 2015. https:\/\/doi.org\/10.1007\/s00402-015-2338-z.","journal-title":"Arch Orthop Trauma Surg"},{"key":"5313_CR3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfoodeng.2016.04.022","author":"S Schuldt","year":"2016","unstructured":"Schuldt S, Arnold G, Kowalewski J, Schneider Y, Rohm H. Analysis of the sharpness of blades for food cutting. J Food Eng. 2016. https:\/\/doi.org\/10.1016\/j.jfoodeng.2016.04.022.","journal-title":"J Food Eng"},{"key":"5313_CR4","doi-asserted-by":"publisher","DOI":"10.3390\/met12111900","author":"MA Islam","year":"2022","unstructured":"Islam MA, Kamarrudin NS, Daud R, Mohd Noor SNF, Azmi AI, Razlan ZMA. Review of surgical bone drilling and drill bit heat generation for implantation. Metals. 2022. https:\/\/doi.org\/10.3390\/met12111900.","journal-title":"Metals"},{"issue":"3","key":"5313_CR5","doi-asserted-by":"publisher","first-page":"330","DOI":"10.2460\/javma.2003.223.330","volume":"223","author":"MR Reems","year":"2003","unstructured":"Reems MR, Beale BS, Hulse DA. Use of a plate-rod construct and principles of biological osteosynthesis for repair of diaphyseal fractures in dogs and cats: 47 cases (1994\u20132001). JAVMA. 2003;223(3):330\u20135.","journal-title":"JAVMA"},{"key":"5313_CR6","doi-asserted-by":"publisher","DOI":"10.3923\/ajas.2015.361.369","author":"LR Mesquita","year":"2015","unstructured":"Mesquita LR, Muzzi LAL, Lima JT, Muzzi RAL, Lacreta Junior ACC, Silva WG. Biomechanical comparison of Plate-Nail Vs. Plate-Rod for Experimentally-Induced gap fractures in ex vivo canine femora. Asian J Anim Sci. 2015. https:\/\/doi.org\/10.3923\/ajas.2015.361.369.","journal-title":"Asian J Anim Sci"},{"key":"5313_CR7","volume-title":"3:1993 implants for surgery - Skeletal pins and wires. Part 3: Kirschner skeletal wires","author":"ISO 5838","year":"1993","unstructured":"ISO 5838-. 3:1993 implants for surgery - Skeletal pins and wires. Part 3: Kirschner skeletal wires. Geneva: ISO; 1993."},{"key":"5313_CR8","volume-title":"1:2024 implants for surgery - Metallic materials. Part 1: wrought stainless steel","author":"ISO 5832","year":"2024","unstructured":"ISO 5832-. 1:2024 implants for surgery - Metallic materials. Part 1: wrought stainless steel. Geneva: ISO; 2024."},{"key":"5313_CR9","volume-title":"1:2012 orthopedic drilling instruments. Part 1: drill bits, taps and countersink cutters","author":"ISO 9714","year":"2012","unstructured":"ISO 9714-. 1:2012 orthopedic drilling instruments. Part 1: drill bits, taps and countersink cutters. Geneva: ISO; 2012."},{"key":"5313_CR10","volume-title":"1991 implants for surgery - Metal bone screws with hexagonal drive connection, spherical under-surface of head, asymmetrical thread - Dimensions","author":"ISO 5835","year":"1991","unstructured":"ISO 5835. 1991 implants for surgery - Metal bone screws with hexagonal drive connection, spherical under-surface of head, asymmetrical thread - Dimensions. Geneva: ISO; 1991."},{"key":"5313_CR11","volume-title":"2006-11 parallel Shank twist drills, jobber series","author":"DIN 338","year":"2006","unstructured":"DIN 338. 2006-11 parallel Shank twist drills, jobber series. Berlin: DIN; 2006."},{"key":"5313_CR12","doi-asserted-by":"publisher","DOI":"10.12775\/PYEL.2015.004","author":"B Rakoczy","year":"2016","unstructured":"Rakoczy B. Act on the protection of animals used for scientific or educational purposes-legal regulation review. Pol Yearbook Environ Law. 2016. https:\/\/doi.org\/10.12775\/PYEL.2015.004.","journal-title":"Pol Yearbook Environ Law"},{"key":"5313_CR13","first-page":"46","volume-title":"Statistics with confidence: confidence intervals and statistical guidelines","author":"DG Altman","year":"2000","unstructured":"Altman DG, Machin D, Bryant TN, Gardner MJ. Statistics with confidence: confidence intervals and statistical guidelines. 2nd ed. Bristol, UK: BMJ Books; 2000. pp. 46\u20137.","edition":"2"},{"key":"5313_CR14","volume-title":"2018 tool steels","author":"ISO 4957","year":"2018","unstructured":"ISO 4957. 2018 tool steels. Geneva: ISO; 2018."},{"key":"5313_CR15","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/2976795","author":"S Townsend","year":"2018","unstructured":"Townsend S, Lewis DD. Use of the minimally invasive reduction instrumentation system for facilitating alignment and reduction when performing minimally invasive plate osteosynthesis in three dogs. Case Rep Veterinary Med. 2018. https:\/\/doi.org\/10.1155\/2018\/2976795.","journal-title":"Case Rep Veterinary Med"},{"key":"5313_CR16","doi-asserted-by":"crossref","unstructured":"Beale B, McCally R. Minimally invasive fracture repair of the tibia and fibula. Vet Clin Small Anim. 2020. pp. 183\u2013206.","DOI":"10.1016\/j.cvsm.2019.08.008"},{"key":"5313_CR17","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1997.tb00516.x","author":"D Hulse","year":"1997","unstructured":"Hulse D, Hyman W, Nori M, et al. Reduction in plate strain by addition of an intramedullary pin. Vet Surg. 1997. https:\/\/doi.org\/10.1111\/j.1532-950X.1997.tb00516.x.","journal-title":"Vet Surg"},{"key":"5313_CR18","doi-asserted-by":"publisher","DOI":"10.1111\/vsu.14320","author":"KL Perry","year":"2025","unstructured":"Perry KL, Wesslen R. Outcomes of 243 dogs with traumatic fractures treated with the I-Loc interlocking nail. Vet Surg. 2025. https:\/\/doi.org\/10.1111\/vsu.14320.","journal-title":"Vet Surg"},{"key":"5313_CR19","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.78.6.712","author":"G Tremolada","year":"2017","unstructured":"Tremolada G, Lewis DD, Paragnani KL, Conrad BP, Kim SE, Pozzi A. Biomechanical comparison of a 3.5\u00a0mm conical coupling plating system and a 3.5\u00a0mm locking compression plate applied as plate-rod constructs to an experimentally created fracture gap in femurs of canine cadavers. Am J Vet Res. 2017. https:\/\/doi.org\/10.2460\/ajvr.78.6.712.","journal-title":"Am J Vet Res"},{"key":"5313_CR20","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.70.1.23","author":"CS Goh","year":"2009","unstructured":"Goh CS, Santoni BG, Puttlitz CM, Palmer RH. Comparison of the mechanical behaviors of semicontoured, locking plate-rod fixation and anatomically contoured, conventional plate-rod fixation applied to experimentally induced gap fractures in canine femora. Am J Vet Res. 2009. https:\/\/doi.org\/10.2460\/ajvr.70.1.23.","journal-title":"Am J Vet Res"},{"key":"5313_CR21","doi-asserted-by":"publisher","DOI":"10.3415\/VCOT-16-03-0040","author":"EJ Field","year":"2016","unstructured":"Field EJ, Parsons K, Etches JA, Hamilton K, Burton NJ. Effect of monocortical and bicortical screw numbers on the properties of a locking plate intramedullary rod configuration an in vitro study on a canine femoral fracture gap model. Vet Comp Orthop Traumatol. 2016. https:\/\/doi.org\/10.3415\/VCOT-16-03-0040.","journal-title":"Vet Comp Orthop Traumatol"},{"key":"5313_CR22","first-page":"499","volume":"38","author":"C Lavelle","year":"1980","unstructured":"Lavelle C, Wedgwood D. Effect of internal irrigation on frictional heat generation from bone drilling. J Oral Surg. 1980;38:499\u2013502.","journal-title":"J Oral Surg"},{"key":"5313_CR23","doi-asserted-by":"publisher","DOI":"10.1007\/BF02467546","author":"VI Shemegon","year":"1998","unstructured":"Shemegon VI. Surface hardening of twist drills. Met Sci Heat Treat. 1998. https:\/\/doi.org\/10.1007\/BF02467546.","journal-title":"Met Sci Heat Treat"},{"key":"5313_CR24","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2023.122262","author":"L Meng","year":"2023","unstructured":"Meng L, Wu J, Geng W, Yang Y, Li X, Xu K, Li K, Li Y, Duan Q, Gao P, Cai K. Regulation of localized corrosion of 316L stainless steel on osteogenic differentiation of bone marrow derived mesenchymal stem cells. Biomaterials. 2023. https:\/\/doi.org\/10.1016\/j.biomaterials.2023.122262.","journal-title":"Biomaterials"},{"key":"5313_CR25","doi-asserted-by":"publisher","DOI":"10.1016\/s0020-1383(00)80015-7","author":"JA Disegi","year":"2000","unstructured":"Disegi JA, Eschbach L. Stainless steel in bone surgery. Injury. 2000. https:\/\/doi.org\/10.1016\/s0020-1383(00)80015-7.","journal-title":"Injury"},{"key":"5313_CR26","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2022.e08927","author":"JG Tsiagadigui","year":"2022","unstructured":"Tsiagadigui JG, Ndiwe B, Ngo Yamben MA, Fotio N, Belinga FE, Njeugna E. The effects of multiple drilling of a bone with the same drill bit: thermal and force analysis. Heliyon. 2022. https:\/\/doi.org\/10.1016\/j.heliyon.2022.e08927.","journal-title":"Heliyon"},{"key":"5313_CR27","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-020-02600-2","author":"MFA Akhbar","year":"2020","unstructured":"Akhbar MFA, Sulong AW. Surgical drill bit design and thermomechanical damage in bone drilling: a review. Ann Biomed Eng. 2020. https:\/\/doi.org\/10.1007\/s10439-020-02600-2.","journal-title":"Ann Biomed Eng"},{"key":"5313_CR28","doi-asserted-by":"publisher","DOI":"10.3390\/ma17235729","author":"M Sydor","year":"2024","unstructured":"Sydor M, Waszkiewicz K, Potok Z. Impact of drill bit wear on screw withdrawal resistance in Pinewood. Materials. 2024. https:\/\/doi.org\/10.3390\/ma17235729.","journal-title":"Materials"},{"key":"5313_CR29","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0319492","author":"M Sorgato","year":"2025","unstructured":"Sorgato M, Bottin A, Stocchero M, Toia M, Savio E. Impact of drill bit wear on temperature increase in dental implant osteotomy: an in vitro study. PLoS ONE. 202510.1371\/journal. pone.0319492.","journal-title":"PLoS ONE"},{"issue":"2","key":"5313_CR30","first-page":"22","volume":"42","author":"JC Woods","year":"2022","unstructured":"Woods JC, Cook JL, Bozynski CC, Tegethoff JD, Kuroki K, Crist BD. Does irrigating while drilling decrease bone damage? Iowa Orthop J. 2022;42(2):22\u20139.","journal-title":"Iowa Orthop J"},{"key":"5313_CR31","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-33381-y","author":"K Alam","year":"2023","unstructured":"Alam K, Qamar SZ, Iqbal M, Piya S, Al.-Kindi M, Qureshi A, Al-Ghaithi A, Al-Sumri B, Silberschmidt VV. Effect of drill quality on biological damage in bone drilling. Sci Rep. 2023. https:\/\/doi.org\/10.1038\/s41598-023-33381-y.","journal-title":"Sci Rep"},{"key":"5313_CR32","doi-asserted-by":"publisher","DOI":"10.1016\/s0300-9785(82)80020-3","author":"A Eriksson","year":"1982","unstructured":"Eriksson A, Albrektsson T, Grane B, McQueen D. Thermal injury to bone. A vital-microscopic description of heat effects. Int J Oral Surg. 1982. https:\/\/doi.org\/10.1016\/s0300-9785(82)80020-3.","journal-title":"Int J Oral Surg"},{"key":"5313_CR33","doi-asserted-by":"publisher","DOI":"10.1016\/00223913(83)90174-9","author":"AR Eriksson","year":"1983","unstructured":"Eriksson AR, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent. 1983. https:\/\/doi.org\/10.1016\/00223913(83)90174-9.","journal-title":"J Prosthet Dent"},{"key":"5313_CR34","unstructured":"Thankur AJ. The elements of fracture fixation. 4 ed. Elsevier, Relx India Pvt. Ltd.; 2020. p. 98."},{"key":"5313_CR35","doi-asserted-by":"publisher","first-page":"154","DOI":"10.22382\/wfs-2018-017","volume":"50","author":"E Sharapov","year":"2018","unstructured":"Sharapov E, Wang X, Smirnova E, Wacker E. Wear behavior of drill Bits in wood drilling resistance measurements. Wood Fiber Sci. 2018;50:154\u201366. https:\/\/doi.org\/10.22382\/wfs-2018-017.","journal-title":"Wood Fiber Sci"}],"container-title":["BMC Veterinary Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12917-026-05313-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12917-026-05313-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12917-026-05313-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T12:21:42Z","timestamp":1771849302000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12917-026-05313-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,29]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["5313"],"URL":"https:\/\/doi.org\/10.1186\/s12917-026-05313-1","relation":{},"ISSN":["1746-6148"],"issn-type":[{"value":"1746-6148","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,29]]},"assertion":[{"value":"9 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval and other permissions were unnecessary to collect the specimens in this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"121"}}