{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T01:14:12Z","timestamp":1783300452205,"version":"3.54.6"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T00:00:00Z","timestamp":1778457600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T00:00:00Z","timestamp":1783296000000},"content-version":"vor","delay-in-days":56,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Vet Res"],"DOI":"10.1186\/s12917-026-05553-1","type":"journal-article","created":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T13:55:04Z","timestamp":1778507704000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Ultrasound measurement of the optic nerve and its sheath using the CLOSED protocol: comparison with MRI in a porcine in-vivo model"],"prefix":"10.1186","volume":"22","author":[{"given":"Ludwika","family":"G\u0105sior","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Przemys\u0142aw","family":"Prz\u0105dka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mateusz","family":"Hebel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kamil","family":"Suliga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Agnieszka","family":"Anto\u0144czyk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,11]]},"reference":[{"key":"5553_CR1","unstructured":"Mayer SA, Louis ED,Noble JM, editors. Merritt Neurologia vol. I. 14th ed. Turaj W, editor of Polish edition. Wroc\u0142aw: Edra Urban & Partner; 2023."},{"key":"5553_CR2","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1016\/j.jocn.2021.01.021","volume":"86","author":"BCP Jeng","year":"2021","unstructured":"Jeng BCP, De Andrade AF, Brasil S, Bor-Seng-Shu E, Belon AR, Robertis M, et al. Estimation of intracranial pressure by ultrasound of the optic nerve sheath in an animal model of intracranial hypertension. J Clin Neurosci. 2021;86:174\u20139. https:\/\/doi.org\/10.1016\/j.jocn.2021.01.021.","journal-title":"J Clin Neurosci"},{"issue":"9","key":"5553_CR3","doi-asserted-by":"publisher","first-page":"4029","DOI":"10.1007\/s00464-015-4715-7","volume":"30","author":"TH Kamine","year":"2016","unstructured":"Kamine TH, Elmadhun NY, Kasper EM, Papavassiliou E, Schneider BE. Abdominal insufflation for laparoscopy increases intracranial and intrathoracic pressure in human subjects. Surg Endosc. 2016;30(9):4029\u201332. https:\/\/doi.org\/10.1007\/s00464-015-4715-7.","journal-title":"Surg Endosc"},{"issue":"5","key":"5553_CR4","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1016\/S1091-255X(98)80031-0","volume":"2","author":"RJ Rosenthal","year":"1998","unstructured":"Rosenthal RJ, Friedman RL, Kahn AM, Martz J, Thiagarajah S, Cohen D, et al. Reasons for intracranial hypertension and hemodynamic instability during acute elevations of intra-abdominal pressure: observations in a large animal model. J Gastrointest Surg. 1998;2(5):415\u201325. https:\/\/doi.org\/10.1016\/S1091-255X(98)80031-0.","journal-title":"J Gastrointest Surg"},{"issue":"1","key":"5553_CR5","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1186\/s13054-017-1632-2","volume":"21","author":"FA Rasulo","year":"2017","unstructured":"Rasulo FA, Bertuetti R, Robba C, Lusenti F, Cantoni A, Bernini M, et al. The accuracy of transcranial Doppler in excluding intracranial hypertension following acute brain injury: a multicenter prospective pilot study. Crit Care. 2017;21(1):44. https:\/\/doi.org\/10.1186\/s13054-017-1632-2.","journal-title":"Crit Care"},{"issue":"4","key":"5553_CR6","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1590\/0004-282x-anp-2020-0591","volume":"80","author":"MS Soares","year":"2022","unstructured":"Soares MS, Andrade AFD, Brasil S, De-Lima-Oliveira M, Belon AR, Bor-Seng-Shu E, et al. Evaluation of cerebral hemodynamics by transcranial Doppler ultrasonography and its correlation with intracranial pressure in an animal model of intracranial hypertension. Arq Neuropsiquiatr. 2022;80(4):344\u201352. https:\/\/doi.org\/10.1590\/0004-282x-anp-2020-0591.","journal-title":"Arq Neuropsiquiatr"},{"issue":"5","key":"5553_CR7","doi-asserted-by":"publisher","first-page":"814","DOI":"10.1111\/jon.12906","volume":"31","author":"RRF Stevens","year":"2021","unstructured":"Stevens RRF, Gommer ED, Aries MJH, Ertl M, Mess WH, Huberts W, et al. Optic nerve sheath diameter assessment by neurosonology: A review of methodologic discrepancies. J Neuroimaging. 2021;31(5):814\u201325. https:\/\/doi.org\/10.1111\/jon.12906.","journal-title":"J Neuroimaging"},{"issue":"1","key":"5553_CR8","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1007\/s00464-015-4159-0","volume":"30","author":"F Dip","year":"2016","unstructured":"Dip F, Nguyen D, Rosales A, Sasson M, Menzo EL, Szomstein S, et al. Impact of controlled intraabdominal pressure on the optic nerve sheath diameter during laparoscopic procedures. Surg Endosc. 2016;30(1):44\u20139. https:\/\/doi.org\/10.1007\/s00464-015-4159-0.","journal-title":"Surg Endosc"},{"issue":"1","key":"5553_CR9","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1007\/s12028-019-00853-x","volume":"32","author":"R Aspide","year":"2020","unstructured":"Aspide R, Bertolini G, Albini Riccioli L, Mazzatenta D, Palandri G, Biasucci DG. A Proposal for a New Protocol for Sonographic Assessment of the Optic Nerve Sheath Diameter: The CLOSED Protocol. Neurocrit Care. 2020;32(1):327\u201332. https:\/\/doi.org\/10.1007\/s12028-019-00853-x.","journal-title":"Neurocrit Care"},{"issue":"1","key":"5553_CR10","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1186\/s13089-022-00291-5","volume":"14","author":"R Aspide","year":"2022","unstructured":"Aspide R, Bertolini G, Belotti LMB, Albini Riccioli L, Toni F, Mazzatenta D, et al. The CLOSED protocol to assess optic nerve sheath diameter using color-Doppler: a comparison study in a cohort of idiopathic normal pressure hydrocephalus patients. Ultrasound J. 2022;14(1):43. https:\/\/doi.org\/10.1186\/s13089-022-00291-5.","journal-title":"Ultrasound J"},{"issue":"1","key":"5553_CR11","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1111\/jon.12936","volume":"32","author":"J Pansell","year":"2022","unstructured":"Pansell J, Bell M, Rudberg P, Friman O, Cooray C. Optic nerve sheath diameter measurement by ultrasound: Evaluation of a standardized protocol. J Neuroimaging. 2022;32(1):104\u201310. https:\/\/doi.org\/10.1111\/jon.12936.","journal-title":"J Neuroimaging"},{"issue":"5","key":"5553_CR12","doi-asserted-by":"publisher","first-page":"651","DOI":"10.7863\/jum.2011.30.5.651","volume":"30","author":"DR Hamilton","year":"2011","unstructured":"Hamilton DR, Sargsyan AE, Melton SL, Garcia KM, Oddo B, Kwon DS, et al. Sonography for Determining the Optic Nerve Sheath Diameter With Increasing Intracranial Pressure in a Porcine Model. J Ultrasound Med. 2011;30(5):651\u20139. https:\/\/doi.org\/10.7863\/jum.2011.30.5.651.","journal-title":"J Ultrasound Med"},{"key":"5553_CR13","doi-asserted-by":"publisher","unstructured":"Mija R, Zubak I, Schuetz A, Glas M, Fung C, Jakob SM et al. Correlation of optic nerve and optic nerve sheath diameter with intracranial pressure in pigs. Patel N, editor. PLOS ONE. 2020;15(2):e0228242. https:\/\/doi.org\/10.1371\/journal.pone.0228242.","DOI":"10.1371\/journal.pone.0228242"},{"issue":"1","key":"5553_CR14","doi-asserted-by":"publisher","first-page":"50","DOI":"10.3357\/ASEM.3664.2014","volume":"85","author":"DM Nusbaum","year":"2014","unstructured":"Nusbaum DM, Antonsen E, Bockhorst KH, Easley RB, Clark JB, Brady KM, et al. Optic Nerve Sheath Diameter Measurement Techniques: Examination Using a Novel Ex-Vivo Porcine Model. Aviat Space Environ Med. 2014;85(1):50\u20134. https:\/\/doi.org\/10.3357\/ASEM.3664.2014.","journal-title":"Aviat Space Environ Med"},{"issue":"3","key":"5553_CR15","doi-asserted-by":"publisher","first-page":"e370308","DOI":"10.1590\/acb370308","volume":"37","author":"MDR Azevedo","year":"2022","unstructured":"Azevedo MDR, de-Lima-Oliveira M, Belon AR, Brasil S, Teixeira MJ, Paiva WS, et al. Assessing ultrasonographic optic nerve sheath diameter in animal model with anesthesia regimens. Acta Cir\u00fargica Bras. 2022;37(3):e370308. https:\/\/doi.org\/10.1590\/acb370308.","journal-title":"Acta Cir\u00fargica Bras"},{"key":"5553_CR16","unstructured":"Heichel J, Wilhelm F, Kunert KS, Hammer T. Topographic findings of the porcine cornea. Med Hypothesis Discov Innov Ophthalmol. 2016;5(4):125\u201331. PMID: 28293660; PMCID: PMC5346302."},{"key":"5553_CR17","unstructured":"Pennick D, D\u2019Anjou MA. Atlas of small animal ultrasonography. 2nd ed. Ames: Wiley Blackwell; 2015."},{"key":"5553_CR18","doi-asserted-by":"publisher","first-page":"797018","DOI":"10.3389\/fmed.2021.797018","volume":"8","author":"L Vitiello","year":"2022","unstructured":"Vitiello L, De Bernardo M, Capasso L, Cornetta P, Rosa N. Optic Nerve Ultrasound Evaluation in Animals and Normal Subjects. Front Med. 2022;8:797018. https:\/\/doi.org\/10.3389\/fmed.2021.797018.","journal-title":"Front Med"},{"issue":"1","key":"5553_CR19","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1111\/vec.12677","volume":"28","author":"JJ Smith","year":"2018","unstructured":"Smith JJ, Fletcher DJ, Cooley SD, Thompson MS. Transpalpebral ultrasonographic measurement of the optic nerve sheath diameter in healthy dogs. J Vet Emerg Crit Care. 2018;28(1):31\u20138. https:\/\/doi.org\/10.1111\/vec.12677.","journal-title":"J Vet Emerg Crit Care"},{"issue":"10","key":"5553_CR20","doi-asserted-by":"publisher","first-page":"959","DOI":"10.1177\/1098612X19898006","volume":"22","author":"MA Evangelisti","year":"2020","unstructured":"Evangelisti MA, Carta G, Burrai GP, Pinna Parpaglia ML, Cubeddu F, Ballocco I, et al. Repeatability of ultrasound examination of the optic nerve sheath diameter in the adult cat: comparison between healthy cats and cats suffering from presumed intracranial hypertension. J Feline Med Surg. 2020;22(10):959\u201365. https:\/\/doi.org\/10.1177\/1098612X19898006.","journal-title":"J Feline Med Surg"},{"issue":"6","key":"5553_CR21","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1111\/vec.70069","volume":"35","author":"CM Valerio-L\u00f3pez","year":"2025","unstructured":"Valerio-L\u00f3pez CM, Murthy VD, Hoehne SN, Mattoon J, Chen AV. Comparison of Ultrasonographic Optic Nerve Sheath Diameter Before and After Mannitol Administration in Dogs With Presumed Intracranial Hypertension. J Vet Emerg Crit Care. 2025;35(6):672\u201380. https:\/\/doi.org\/10.1111\/vec.70069.","journal-title":"J Vet Emerg Crit Care"},{"issue":"2","key":"5553_CR22","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1111\/jon.12691","volume":"30","author":"C Schroeder","year":"2020","unstructured":"Schroeder C, Katsanos AH, Richter D, Tsivgoulis G, Gold R, Krogias C. Quantification of Optic Nerve and Sheath Diameter by Transorbital Sonography: A Systematic Review and Metanalysis. J Neuroimaging. 2020;30(2):165\u201374. https:\/\/doi.org\/10.1111\/jon.12691.","journal-title":"J Neuroimaging"},{"issue":"1","key":"5553_CR23","doi-asserted-by":"publisher","first-page":"130","DOI":"10.7863\/jum.2012.31.1.130","volume":"31","author":"NA Teismann","year":"2012","unstructured":"Teismann NA, Lenaghan P, Stein J, Green A. Will the Real Optic Nerve Sheath Please Stand Up? J Ultrasound Med. 2012;31(1):130\u20131. https:\/\/doi.org\/10.7863\/jum.2012.31.1.130.","journal-title":"J Ultrasound Med"},{"issue":"1","key":"5553_CR24","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1186\/1471-2377-13-187","volume":"13","author":"J B\u00e4uerle","year":"2013","unstructured":"B\u00e4uerle J, Schuchardt F, Schroeder L, Egger K, Weigel M, Harloff A. Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging. BMC Neurol. 2013;13(1):187. https:\/\/doi.org\/10.1186\/1471-2377-13-187.","journal-title":"BMC Neurol"},{"key":"5553_CR25","doi-asserted-by":"crossref","unstructured":"Zimny A, S\u0105siadek MJ. Imaging of Idiopathic Intracranial Hypertension. In: Barkhof F, J\u00e4ger HR, Thurnher MM, Rovira \u00c0, editors. Clinical Neuroradiology. Cham: Springer International Publishing. 2019:545\u201356. Available from: http:\/\/link.springer.com\/10.1007\/978-3-319-68536-6_13. Cited 3 Jun 2025.","DOI":"10.1007\/978-3-319-68536-6_13"}],"container-title":["BMC Veterinary Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12917-026-05553-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12917-026-05553-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12917-026-05553-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T00:14:43Z","timestamp":1783296883000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12917-026-05553-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,11]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["5553"],"URL":"https:\/\/doi.org\/10.1186\/s12917-026-05553-1","relation":{},"ISSN":["1746-6148"],"issn-type":[{"value":"1746-6148","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,11]]},"assertion":[{"value":"23 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was designed and conducted in accordance with the ARRIVE guidelines and approved by the Local Ethics Committee for Animal Experiments at the Hirszfeld Institute of Immunology and Experimental Therapy, Polish Academy of Sciences, Wroc\u0142aw (approval number: 033\/2023\/P1).Consent to participate does not apply.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"395"}}