{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T14:01:34Z","timestamp":1784642494637,"version":"3.55.0"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,25]],"date-time":"2026-05-25T00:00:00Z","timestamp":1779667200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"vor","delay-in-days":57,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002771","name":"Sci-Tech Academy, Zhejiang University","doi-asserted-by":"publisher","award":["24242151-Y"],"award-info":[{"award-number":["24242151-Y"]}],"id":[{"id":"10.13039\/501100002771","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Vet Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Accurate measurement of intraocular pressure in non-human primates is of significant importance in veterinary clinical practice, particularly for the prevention, detection, and management of glaucoma in non-human primates. However, no veterinary tonometer is currently designed specifically for non-human primates.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To investigate the accuracy of the macaque-specific measurement mode of the iFalcon\u2122 V100 rebound tonometer.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>IOP was increased stepwise from 5 mmHg to 90 mmHg in 3\u20135 mmHg increments. At each target pressure, the system was stabilized for 10\u00a0s, then the iFalcon\u2122 V100 recorded six consecutive rebound readings and their average. Each step yielded 2\u20133 such average values. The results were compared with a high-precision invasive pressure sensor. Linear regression and Bland-Altman analyses were performed, and the measurement range was stratified (5\u201330, 30\u201360, 60\u201390 mmHg) for refined assessment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The iFalcon\u2122 V100 showed strong positive correlation with the invasive sensor (y\u2009=\u20090.99x\u2009+\u20090.42, R\u00b2 = 0.99). The mean difference was \u2212\u20090.036 mmHg (95% limits of agreement: -3.747 to 3.675 mmHg). Within the 5\u201330 mmHg range, agreement was excellent (mean difference: -0.063 mmHg). Acceptable agreement was maintained up to 90 mmHg.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This ex vivo study provides an initial assessment of the iFalcon\u2122 V100 rebound tonometer in non-human primate eyes. The device showed good correlation and agreement with an invasive pressure sensor across a wide pressure range. While the sample size was limited, these preliminary findings support the potential of this species-specific measurement mode for IOP assessment in non-human primate research. Further studies with more eyes and in vivo conditions are needed to confirm its reliability and repeatability.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12917-026-05578-6","type":"journal-article","created":{"date-parts":[[2026,5,25]],"date-time":"2026-05-25T10:05:58Z","timestamp":1779703558000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Initial assessment of a species-specific rebound measurement mode for non-human primates"],"prefix":"10.1186","volume":"22","author":[{"given":"Yingbo","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunhao","family":"Su","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaiming","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji","family":"Fu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,25]]},"reference":[{"key":"5578_CR1","doi-asserted-by":"publisher","unstructured":"Harry M, Jane B. Intraocular pressure, continuing education in anaesthesia critical care & pain. 2008;8(3):100\u201303. https:\/\/doi.org\/10.1093\/bjaceaccp\/mkn015.","DOI":"10.1093\/bjaceaccp\/mkn015"},{"key":"5578_CR2","doi-asserted-by":"publisher","unstructured":"Goldberg I. Relationship between intraocular pressure and preservation of visual field in glaucoma. Surv Ophthalmol. 2003;48(2 Suppl):S3\u2013S7. https:\/\/doi.org\/10.1016\/S0039-6257(03)00006-7","DOI":"10.1016\/S0039-6257(03)00006-7"},{"key":"5578_CR3","doi-asserted-by":"publisher","first-page":"e001386","DOI":"10.1136\/bmjophth-2023-001386","volume":"8","author":"M Sharfuddin Ahmed","year":"2023","unstructured":"Sharfuddin Ahmed M, Ullah AY, Barman N, Ratan ZA, Mostafa S, Khaleque A, et al. Risk factors associated with elevated intraocular pressure: a population-based study in a rural community of Bangladesh. BMJ Open Ophthalmol. 2023;8:e001386. https:\/\/doi.org\/10.1136\/bmjophth-2023-001386.","journal-title":"BMJ Open Ophthalmol"},{"key":"5578_CR4","doi-asserted-by":"publisher","unstructured":"Yilmaz I, Altan C, Aygit ED, Alagoz C, Baz O, Ahmet S, Demirok A. Comparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer, and Tono-Pen XL.\u00a0Clin Ophthalmol.\u00a02014;8:1069\u201374. https:\/\/doi.org\/10.2147\/OPTH.S6391.","DOI":"10.2147\/OPTH.S6391"},{"key":"5578_CR5","doi-asserted-by":"publisher","first-page":"3860","DOI":"10.3390\/jcm10173860","volume":"10","author":"P Brusini","year":"2021","unstructured":"Brusini P, Salvetat ML, Zeppieri M. How to Measure Intraocular Pressure: An Updated Review of Various Tonometers. J Clin Med. 2021;10:3860. https:\/\/doi.org\/10.3390\/jcm10173860.","journal-title":"J Clin Med"},{"issue":"1","key":"5578_CR6","doi-asserted-by":"publisher","first-page":"E16","DOI":"10.1097\/OPX.0b013e318205a4e7","volume":"88","author":"RL Stamper","year":"2011","unstructured":"Stamper RL. A history of intraocular pressure and its measurement. Optom Vis Sci. 2011;88(1):E16\u201328.","journal-title":"Optom Vis Sci"},{"key":"5578_CR7","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/bs.pbr.2015.06.003","volume":"221","author":"J Garcia-Feijoo","year":"2015","unstructured":"Garcia-Feijoo J, et al. New technologies for measuring intraocular pressure. Prog Brain Res. 2015;221:67\u201379.","journal-title":"Prog Brain Res"},{"key":"5578_CR8","doi-asserted-by":"publisher","unstructured":"Nakakura, S. (2018). Icare\u00ae rebound tonometers: review of their characteristics and ease of use. Clinical Ophthalmology, 12, 1245\u20131253. https:\/\/doi.org\/10.2147\/OPTH.S16309.","DOI":"10.2147\/OPTH.S16309"},{"issue":"7","key":"5578_CR9","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1111\/j.1755-3768.2009.01774.x","volume":"89","author":"M Martinez-de\u2010la\u2010Casa, Jose","year":"2011","unstructured":"Martinez-de\u2010la\u2010Casa, Jose M, et al. Performance of the rebound, noncontact and Goldmann applanation tonometers in routine clinical practice. Acta Ophthalmol. 2011;89(7):676\u201380.","journal-title":"Acta Ophthalmol"},{"issue":"12","key":"5578_CR10","doi-asserted-by":"publisher","first-page":"4578","DOI":"10.1167\/iovs.05-0586","volume":"46","author":"JM Martinez-de-la-Casa","year":"2005","unstructured":"Martinez-de-la-Casa JM, et al. Reproducibility and clinical evaluation of rebound tonometry. Investig Ophthalmol Vis Sci. 2005;46(12):4578\u201380.","journal-title":"Investig Ophthalmol Vis Sci"},{"issue":"13","key":"5578_CR11","first-page":"568","volume":"51","author":"JA Kiland","year":"2010","unstructured":"Kiland JA, Elsmo EJ, Hennes EA, Kaufman PL. McLellan; Evaluation of Rebound and Applanation Tonometry in Cynomolgus Monkeys. Invest Ophthalmol Vis Sci. 2010;51(13):568.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"8","key":"5578_CR12","first-page":"785","volume":"18","author":"LZ Bito","year":"1979","unstructured":"Bito LZ, Merritt SQ. DeRousseau. Intraocular pressure of rhesus monkey (Macaca mulatta). I. An initial survey of two free-breeding colonies. Investig Ophthalmol Vis Sci. 1979;18(8):785\u201393.","journal-title":"Investig Ophthalmol Vis Sci"},{"issue":"3","key":"5578_CR13","first-page":"190","volume":"10","author":"JAMESL MINIS","year":"1971","unstructured":"MINIS JAMESL. Applanation and Schi\u00f8tz Tonometer Standardizations for the Owl Monkey Eye with a New Technique for Measuring Episcleral Venous Pressure. Invest Ophthalmol Vis Sci. 1971;10(3):190\u20137.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"5578_CR14","doi-asserted-by":"publisher","first-page":"819715","DOI":"10.3389\/fmed.2022.819715","volume":"9","author":"P Wang","year":"2022","unstructured":"Wang P, Song Y, Lin F, Wang Z, Gao X, Cheng W, Chen M, Peng Y, Liu Y, Zhang X, Chen S. Comparison of Non-contact Tonometry and Goldmann Applanation Tonometry Measurements in Non-pathologic High Myopia. Front Med. 2022;9:819715. https:\/\/doi.org\/10.3389\/fmed.2022.819715.","journal-title":"Front Med"},{"issue":"4","key":"5578_CR15","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1016\/S0014-4835(81)80020-6","volume":"32","author":"CJ De Rousseau","year":"1981","unstructured":"De Rousseau CJ, Bito LZ. Intraocular pressure of rhesus monkeys (Macaca mulatta) II. Juvenile ocular hypertension and its apparent relationship to ocular growth. Exp Eye Res. 1981;32(4):407\u201317. https:\/\/doi.org\/10.1016\/S0014-4835(81)80020-6.","journal-title":"Exp Eye Res"},{"key":"5578_CR16","doi-asserted-by":"publisher","unstructured":"Pease MEMS, Hammond JCAB, Quigley HAMD. Manometric calibration and comparison of TonoLab and TonoPen tonometers in rats with experimental glaucoma and in normal mice. J Glaucoma. 2006;15(6):512\u20139. https:\/\/doi.org\/10.1097\/01.ijg.0000212276.57853.19.","DOI":"10.1097\/01.ijg.0000212276.57853.19"},{"issue":"2","key":"5578_CR17","doi-asserted-by":"publisher","first-page":"858","DOI":"10.1167\/iovs.10-5556","volume":"52","author":"E Mary","year":"2011","unstructured":"Mary E, Pease FE, Cone S, Gelman JL, Son, Harry A. Quigley; Calibration of the TonoLab Tonometer in Mice with Spontaneous or Experimental Glaucoma. Invest Ophthalmol Vis Sci. 2011;52(2):858\u201364. https:\/\/doi.org\/10.1167\/iovs.10-5556.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"5578_CR18","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.exer.2014.02.004","volume":"121","author":"H Zhang","year":"2014","unstructured":"Zhang H, Yang D, Ross CM, Wigg JP, Pandav S, Crowston JG. Validation of rebound tonometry for intraocular pressure measurement in the rabbit. Exp Eye Res. 2014;121:86\u201393. https:\/\/doi.org\/10.1016\/j.exer.2014.02.004.","journal-title":"Exp Eye Res"},{"key":"5578_CR19","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1111\/j.1463-5224.2010.00859.x","volume":"14","author":"Y-W Park","year":"2011","unstructured":"Park Y-W, Jeong M-B, Kim T-H, Ahn J-S, Ahn J-T, Park S-A, Kim S-E, Seo K. Effect of central corneal thickness on intraocular pressure with the rebound tonometer and the applanation tonometer in normal dogs. Vet Ophthalmol. 2011;14:169\u201373. https:\/\/doi.org\/10.1111\/j.1463-5224.2010.00859.x.","journal-title":"Vet Ophthalmol"},{"key":"5578_CR20","unstructured":"iCare TONOVET Plus Tonometer Brochure, iCare\/Tonovet M. 2025. https:\/\/tonovet.com\/wp-content\/uploads\/2025\/05\/190425_Icare-TONOVET_TONOVET_Plus_brochure_Icare-VET-010-EN-1.0_HIGH-2-1.pdf."},{"key":"5578_CR21","doi-asserted-by":"publisher","unstructured":"Pan L, Wang N, Wu J. Non-human primates as preclinical models for optic nerve research: advancing insights into their application and potential. Eye.\u00a02025;39:1254\u201363. https:\/\/doi.org\/10.1038\/s41433-025-03665-w.","DOI":"10.1038\/s41433-025-03665-w"},{"key":"5578_CR22","doi-asserted-by":"publisher","unstructured":"Liu H, Hou S, Zhu S, Liu W, Regmi M, Yang C, Wu J, Wang N.\u00a0Macular thickness and its associated factors in a healthy cynomolgus colony: the non-human primates eye study.\u00a0Ophthalmol Sci. 2026;6(1):100981. https:\/\/doi.org\/10.1016\/j.xops.2025.100981.","DOI":"10.1016\/j.xops.2025.100981"},{"issue":"6","key":"5578_CR23","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1111\/vop.13215","volume":"27","author":"LE Kapeller","year":"2024","unstructured":"Kapeller LE, et al. Validation of the eyeTelemed IOPvet indentation tonometer for use in dogs. Vet Ophthalmol. 2024;27(6):492\u2013500.","journal-title":"Vet Ophthalmol"},{"key":"5578_CR24","unstructured":"KAVITA. Linear regression in machine learning. Analytics Vidhya. 2025. https:\/\/www.analyticsvidhya.com\/blog\/2021\/10\/everything-you-need-to-know-about-linear-regression\/."},{"issue":"3","key":"5578_CR25","first-page":"e71","volume":"92","author":"A Carkeet","year":"2015","unstructured":"Carkeet A. Exact parametric confidence intervals for Bland-Altman Limits of Agreement.Optometry. Vis Sci. 2015;92(3):e71\u201380.","journal-title":"Vis Sci"},{"issue":"8","key":"5578_CR26","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1016\/j.ijnurstu.2009.10.001","volume":"47","author":"J Bland","year":"2010","unstructured":"Bland J, Martin, Douglas G. Altman. Statistical methods for assessing agreement between two methods of clinical measurement. Int J Nurs Stud. 2010;47(8):931\u20136.","journal-title":"Int J Nurs Stud"},{"issue":"3","key":"5578_CR27","doi-asserted-by":"publisher","first-page":"1198","DOI":"10.1167\/iovs.07-1536","volume":"50","author":"H Nakamura","year":"2009","unstructured":"Nakamura H, et al. Femtosecond laser photodisruption of primate trabecular meshwork: an ex vivo study. Investig Ophthalmol Vis Sci. 2009;50(3):1198\u2013204.","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"5578_CR28","doi-asserted-by":"publisher","unstructured":"HE H, JIN Z. \"Recent advances in nonhuman primate models of macular diseases.\"\u00a0Chin J Ocul Fundus Dis. 2023;39(11):953\u201357. https:\/\/doi.org\/10.3760\/cma.j.cn511434-20221207-00647.","DOI":"10.3760\/cma.j.cn511434-20221207-00647"},{"issue":"3","key":"5578_CR29","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1111\/vop.13213","volume":"27","author":"LE Kapeller","year":"2024","unstructured":"Kapeller LE, et al. Validation of the Reichert\u00ae Tono-Vera\u00ae Vet rebound tonometer in normal ex vivo canine eyes. Vet Ophthalmol. 2024;27(3):290\u20133.","journal-title":"Vet Ophthalmol"},{"issue":"6","key":"5578_CR30","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1111\/vop.13142","volume":"26","author":"EP Mills","year":"2023","unstructured":"Mills EP, et al. Validation of a novel rebound tonometer (Tono-Vera\u00ae Vet) in normal ex vivo rabbit eyes. Vet Ophthalmol. 2023;26(6):555\u20139.","journal-title":"Vet Ophthalmol"},{"key":"5578_CR31","unstructured":"Reichert Technologies. Reichert\u00ae Tono-Vera\u00ae Vet Tonometer - Rechargeable Model. Reichert Technologies, n.d. https:\/\/www.reichert.com\/en\/products\/tono-vera-vet. Accessed 16 Dec 2025."},{"key":"5578_CR32","unstructured":"Icare Finland Oy. iCare TONOVET Pro Instruction Manual, TV031-009-EN-1.0. Tonovet. 2024. https:\/\/tonovet.com\/wp-content\/uploads\/2024\/07\/iCare_TONOVET_PRO_Instruction_manual_TV031-009-EN-1.0.pdf."},{"key":"5578_CR33","unstructured":"Icare Finland Oy. iCare TONOVET Plus Instruction Manual, TV011-002-EN-1.3. Tonovet. 2025. https:\/\/tonovet.com\/wp-content\/uploads\/2025\/08\/iCare-TONOVET-Plus-TV011-002-EN-1-3.pdf."},{"issue":"3","key":"5578_CR34","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1111\/vop.13067","volume":"26","author":"EP Mills","year":"2023","unstructured":"Mills EP, et al. Calibration of a novel rebound tonometer (Tono-Vera\u00ae vet) in the Porcine eye. Vet Ophthalmol. 2023;26(3):268\u201372.","journal-title":"Vet Ophthalmol"},{"issue":"3","key":"5578_CR35","first-page":"277","volume":"5","author":"Y Yi","year":"2012","unstructured":"Yi Y, et al. Experimental Tibetan monkey domestication and its application for intraocular pressure measurement. Int J Ophthalmol. 2012;5(3):277.","journal-title":"Int J Ophthalmol"},{"issue":"9","key":"5578_CR36","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1167\/tvst.10.9.20","volume":"10","author":"LR Pasquale","year":"2021","unstructured":"Pasquale LR, et al. Development of primary open angle glaucoma-like features in a rhesus macaque colony from southern China. Translational Vis Sci Technol. 2021;10(9):20\u201320.","journal-title":"Translational Vis Sci Technol"},{"issue":"1","key":"5578_CR37","doi-asserted-by":"publisher","first-page":"1406","DOI":"10.1159\/000533865","volume":"66","author":"X Jia","year":"2023","unstructured":"Jia X, et al. Discovery of clinical manifestations in spontaneous glaucoma suspect nonhuman primates. Ophthalmic Res. 2023;66(1):1406\u201316.","journal-title":"Ophthalmic Res"},{"key":"5578_CR38","doi-asserted-by":"publisher","first-page":"107698","DOI":"10.1016\/j.exer.2019.107698","volume":"185","author":"S Gloe","year":"2019","unstructured":"Gloe S, Rothering A, Kiland JA, McLellan GJ. Validation of the Icare\u00ae TONOVET plus rebound tonometer in normal rabbit eyes. Exp Eye Res. 2019;185:107698. https:\/\/doi.org\/10.1016\/j.exer.2019.107698.","journal-title":"Exp Eye Res"},{"issue":"Suppl 1","key":"5578_CR39","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1111\/vop.12771","volume":"24","author":"J Shim","year":"2021","unstructured":"Shim J, Kang S, Park Y, et al. Comparative intraocular pressure measurements using three different rebound tonometers through in an ex vivo analysis and clinical trials in canine eyes. Vet Ophthalmol. 2021;24(Suppl 1):186\u201393. https:\/\/doi.org\/10.1111\/vop.12771.","journal-title":"Vet Ophthalmol"},{"key":"5578_CR40","first-page":"2196","volume":"15","author":"W Yu","year":"2009","unstructured":"Yu W, et al. Evaluation of monkey intraocular pressure by rebound tonometer. Mol Vis. 2009;15:2196.","journal-title":"Mol Vis"},{"issue":"1","key":"5578_CR41","doi-asserted-by":"publisher","first-page":"57","DOI":"10.4103\/ijnmr.IJNMR_187_16","volume":"23","author":"Z Davoodabady","year":"2018","unstructured":"Davoodabady Z, Rezaei K, Reza Rezaei. The impact of normal saline on the incidence of exposure keratopathy in patients hospitalized in intensive care units. Iran J Nurs midwifery Res. 2018;23(1):57\u201360.","journal-title":"Iran J Nurs midwifery Res"}],"container-title":["BMC Veterinary Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12917-026-05578-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12917-026-05578-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12917-026-05578-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T13:05:56Z","timestamp":1784639156000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12917-026-05578-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,25]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["5578"],"URL":"https:\/\/doi.org\/10.1186\/s12917-026-05578-6","relation":{},"ISSN":["1746-6148"],"issn-type":[{"value":"1746-6148","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,25]]},"assertion":[{"value":"13 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study used two fresh eyes from the same experimental rhesus macaque (Macaca mulatta): a 12\u2011year\u2011old male with no documented ocular abnormalities. It should be noted that these eyes were obtained from an experimental macaque that was euthanized for reasons unrelated to this study; no live animals were used, nor was any direct euthanasia performed for the purposes of this research. After the death of the experimental macaque, the eyes were cleaned with sterile saline and placed in sterile saline\u2011filled reagent bottles for transport on ice. Experiments were completed within 8 hours of enucleation to preserve the viability of the ocular tissues as much as possible, prevent tissue degradation, and minimize potential effects on the experimental results.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"432"}}